ICE Components, Inc.
Voice: 800.729.2099 Fax: 678.560.9304
cust.serv@icecomp.com www.icecomponents.com
Gate Drive Transformer
Features
• Meets medical safety isolation requirements • Designed for frequencies from 20 kHz to 300 kHz • Available in UL Class F (155˚C) or Economical Class B (130˚C) Versions
GT04 Series
Applications
• Gate Drive Transformer • Signal Transformer Across Isolation Barriers • Off-Line AC/DC Converters • High-Powered DC/DC Converters
Packaging: Tray=45 pieces, Box=12 trays, Box=540 pieces
Mechanical
20.57 max 12.19 max
Recommended PCB Layout
17.8 ref 6 19.05 max 8.9 ref 1 2 5.0 3 5 4
GT04-XXX-XXX-X ICA YYWW-X
3.5+/-0.3 0.64 sq
1.2 dia
Unit: mm
Schematic
2 2
A
1 Drive 6
Gate 5 3 Gate 4
B
1 Drive 6
Gate 3 5 Gate 4
Specifications subject to change without notice.
(12/06) GT04-1
ICE Components, Inc.
Voice: 800.729.2099 Fax: 678.560.9304
cust.serv@icecomp.com www.icecomponents.com
Gate Drive Transformer
ELECTRICAL Part Number5 SPECIFICATIONS—STANDARD Primary1 Inductance (mH min.) 0.247 0.990 2.220 3.960 6.180 8.910 0.039 0.158 0.356 0.634 0.990 1.420 DCR (Ω max.) N1:N2:N3 0.04:0.04:0.04 0.07:0.07:0.07 0.2:0.2:0.2 0.5:0.5:0.5 1:1:1 2.7:2.7:2.7 0.02:0.04:0.04 0.04:0.07:0.07 0.1:0.2:0.2 0.2:0.45:0.45 0.4:0.9:0.9 1.1:2.5:2.5 Leakage Inductance (µH,max.) 0.2 0.4 0.5 .7 .8 1.2 0.15 0.2 0.25 0.3 0.4 0.5 E-T Product6 (V-µs) 63 126 189 252 315 378 63 126 189 315 315 378 Turns Ratio (Drive : Gate) 1:1 : 1 1:1 : 1 1:1 : 1 1:1 : 1 1:1 : 1 1:1 : 1 Hi-Pot (Vdc) 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500
GT04 Series
VERSION
GT04-111-063-_ GT04-111-126-_ GT04-111-189-_ GT04-111-252-_ GT04-111-315-_ GT04-111-378-_
GT04-122-063-_ 1 : 2.5 : 2.5 GT04-122-126-_ 1 : 2.5 : 2.5 GT04-122-189-_ 1 : 2.5 : 2.5 GT04-122-252-_ 1 : 2.5 : 2.5 GT04-122-315-_ 1 : 2.5 : 2.5 GT04-122-378-_ 1 : 2.5 : 2.5 ELECTRICAL Part Number5 GT04-111-063-_E GT04-111-126-_E GT04-111-189-_E GT04-111-252-_E GT04-111-315-_E GT04-111-378-_E GT04-122-063-_E GT04-122-126-_E GT04-122-189-_E GT04-122-252-_E GT04-122-315-_E GT04-122-378-_E
SPECIFICATIONS—ECONOMY DCR (Ω max.) N1:N2:N3 0.07:0.04:0.04 0.16:0.07:0.07 0.2:0.2:0.2 0.8:0.5:0.5 1:1:1 1.2:2.7:2.7 0.04:0.04:0.04 0.06:0.07:0.07 0.1:0.2:0.2 0.34:0.45:0.45 0.4:0.9:0.9 0.5:2.5:2.5 Leakage Inductance (µH, max) 0.4 0.6 0.5 0.9 0.8 1.5 0.4 0.4 0.25 0.6 0.4 0.9
VERSION Hi-Pot (Vdc) 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500
Turns Ratio Primary1 (Drive:Gate) Inductance (mH min.) 1:1:1 1:1:1 1:1:1 1:1:1 1:1:1 1:1:1 1 : 2.5 : 2.5 1 : 2.5 : 2.5 1 : 2.5 : 2.5 1 : 2.5 : 2.5 1 : 2.5 : 2.5 1 : 2.5 : 2.5 0.247 0.990 2.220 3.960 6.180 8.910 0.039 0.158 0.356 0.634 0.990 1.420
E-T Product6 (V-µs) 63 126 189 252 315 378 63 126 189 252 315 378
1. 2. 3. 4. 5. 6.
Tested at 10 kHz, 0.1Vrms. Electrical specifications at 25˚C. Operating range: -40˚C to +130˚C. Meets UL94V-0. Select pin assignment option based on schematics above. For other options please contact ICE Components, Inc. E-T product rating is for the secondary (gate) windings and is based upon a peak flux denisty of 2200 Gauss at 25°C when used in a bipolar-driven application.
Specifications subject to change without notice.
(12/06) GT04-2
很抱歉,暂时无法提供与“GT04-122-315-_E”相匹配的价格&库存,您可以联系我们找货