0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
IDT709089

IDT709089

  • 厂商:

    IDT

  • 封装:

  • 描述:

    IDT709089 - HIGH-SPEED 64K x 8 SYNCHRONOUS DUAL-PORT STATIC RAM - Integrated Device Technology

  • 数据手册
  • 价格&库存
IDT709089 数据手册
HIGH-SPEED 64K x 8 SYNCHRONOUS DUAL-PORT STATIC RAM Features: x x PRELIMINARY IDT709089S/L x x x x True Dual-Ported memory cells which allow simultaneous access of the same memory location High-speed clock to data access – Commercial: 9/12/15ns (max.) Low-power operation – IDT709089S Active: 950mW (typ.) Standby: 5mW (typ.) – IDT709089L Active: 950mW (typ.) Standby: 1mW (typ.) Flow-Through or Pipelined output mode on either port via the FT/PIPE pin Counter enable and reset features Dual chip enables allow for depth expansion without additional logic x x x x Full synchronous operation on both ports – 4ns setup to clock and 1ns hold on all control, data, and address inputs – Data input, address, and control registers – Fast 9ns clock to data out in the Pipelined output mode – Self-timed write allows fast cycle time – 15ns cycle time, 66MHz operation in the Pipelined output mode TTL- compatible, single 5V (±10%) power supply Industrial temperature range (–40°C to +85°C) is available for selected speeds Available in 100-pin Thin Quad Flatpack (TQFP) package Functional Block Diagram R/WL OEL R/WR OER 1 0 0/1 1 0 0/1 CE0L CE1L CE0R CE1R FT/PIPEL 0/1 1 0 0 1 0/1 FT/PIPER I/O0L - I/O7L I/O Control I/O Control I/O0R - I/O7R A15L A0L CLKL Counter/ Address Reg. MEMORY ARRAY Counter/ Address Reg. A15R A0R CLKR ADSL CNTENL CNTRSTL ADSR CNTENR CNTRSTR 3242 drw 01 FEBRUARY 2000 1 ©2000 Integrated Device Technology, Inc. DSC-3242/10 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Description: The IDT709089 is a high-speed 64K x 8 bit synchronous Dual-Port RAM. The memory array utilizes Dual-Port memory cells to allow simultaneous access of any address from both ports. Registers on control, data, and address inputs provide minimal setup and hold times. The timing latitude provided by this approach allows systems to be designed with very short cycle times. With an input data register, the IDT709089 has been optimized for applications having unidirectional or bidirectional data flow in bursts. An automatic power down feature, controlled by CE0 and CE1, permits the on-chip circuitry of each port to enter a very low standby power mode. Fabricated using IDT’s CMOS high-performance technology, these devices typically operate on only 950mW of power. Pin Configuration(1,2,3) CLKR CLKL GND A0R A1R A2R A3R A4R A5R A6R NC NC Index NC NC A7L A8L A9L A10L A11L A12L A13L A14L A15L NC VCC NC NC NC NC 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 3 73 4 72 1 2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 NC NC A6L A5L A4L A3L A2L A1L A0L CNTENR CNTENL ADSR ADSL IDT709089PF PN100-1(4) 100-PIN TQFP TOP VIEW(5) NC NC A7R A8R A9R A10R A11R A12R A13R A14R A15R NC GND NC NC NC NC CE0L CE1L CE0R CE1R CNTRSTL R/WL OEL FT/PIPEL NC NC CNTRSTR R/WR OER FT/PIPER GND NC 3242 drw 02 51 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 NOTES: 1. All VCC pins must be connected to power supply. 2. All GND pins must be connected to ground supply. 3. Package body is approximately 14mm x 14mm x 1.4mm. 4. This package code is used to reference the package diagram. 5. This text does not indicate orientation of the actual part-marking. GND NC I/O7L I/O6L I/O5L I/O4L I/O3L I/O2L GND I/O1L I/O0L VCC GND I/O0R I/O1R I/O2R VCC I/O3R I/O4R I/O5R I/O6R I/O7R NC NC NC 6.42 2 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Pin Names Left Port Right Port Names Chip Enables Read/Write Enable Output Enable Address Data Input/Output Clock Address Strobe Counter Enable Counter Reset Flow-Through/Pipeline Power Ground 3242 tbl 01 CE0L, CE1L R/WL CE0R, CE1R R/WR OEL A0L - A15L I/O0L - I/O7L CLKL OER A0R - A15R I/O0R - I/O7R CLKR ADSL CNTENL CNTRSTL FT/PIPE L ADSR CNTENR CNTRSTR FT/PIPE R VCC GND Truth Table I— Read/Write and Enable Control(1,2,3) OE X X X L H CLK ↑ ↑ ↑ ↑ X CE0 H X L L L CE1 X L H H H R/W X X L H X I/O0-7 High-Z High-Z DIN DOUT High-Z Mode Deselected Deselected Write Read Outputs Disabled 3242 tbl 02 NOTES: 1. "H" = VIH, "L" = VIL, "X" = Don't Care. 2. ADS, CNTEN, CNTRST = X. 3. OE is an asynchronous input signal. Truth Table II—Address Counter Control(1,2) Address X An X X Previous Address X X An An CLK ↑ ↑ ↑ ↑ ADS H L(4) H H CNTEN H H H L (5) CNTRST L H H H I/O(3) DI/O(0) DI/O(n) DI/O(n) DI/O(n+1) Mode Counter Reset to Address 0 External Address Utilized External Address Blocked —Counter Disabled Counter Enable —Internal Address Generation 3242 tbl 03 NOTES: 1. "H" = VIH, "L" = VIL, "X" = Don't Care. 2. CE0 and OE = VIL; CE1 and R/W = VIH. 3. Outputs configured in Flow-Through Output mode; if outputs are in Pipelined mode the data out will be delayed by one cycle. 4. ADS is independent of all other signals including CE0 and CE1. 5. The address counter advances if CNTEN = VIL on the rising edge of CLK, regardless of all other signals including CE0 and CE1. 3 6.42 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Recommended Operating Recommended DC Operating (1,2) Temperature and Supply Voltage Conditions Grade Commercial Industrial Ambient Temperature 0OC to +70OC -40OC to +85OC GND 0V 0V Vcc 5.0V + 10% 5.0V + 10% 3242 tbl 04 Symbol VCC GND VIH Parameter Supply Voltage Ground Input High Voltage Input Low Voltage Min. 4.5 0 2.2 -0.5 (2) Typ. 5.0 0 ____ Max. 5.5 0 6.0 (1) Unit V V V V 3242 tbl 05 NOTES: 1. This is the parameter TA. 2. Industrial temperature: for specific speeds, packages and powers contact your sales office. VIL ____ 0.8 NOTES: 1. VTERM must not exceed VCC + 10%. 2. VIL > -1.5V for pulse width less than 10ns. Absolute Maximum Ratings(1) Symbol VTERM (2) Capacitance(1) Unit V Symbol CIN COUT (3) Rating Terminal Voltage with Respect to GND Temperature Under Bias Storage Temperature DC Output Current Commercial & Industrial -0.5 to +7.0 (TA = +25°C, f = 1.0MHz) Parameter Input Capacitance Output Capacitance Conditions(2) VIN = 3dV VOUT = 3dV Max. 9 10 Unit pF pF 3242 tbl 07 TBIAS TSTG IOUT -55 to +125 -55 to +125 50 o C C o mA 3242 tbl 06 NOTES: 1. These parameters are determined by device characterization, but are not production tested. 2. 3dV references the interpolated capacitance when the input and output switch from 0V to 3V or from 3V to 0V. 3. COUT also references CI/O. NOTES: 1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. 2. VTERM must not exceed Vcc + 10% for more than 25% of the cycle time or 10ns maximum, and is limited to < 20mA for the period of VTERM > Vcc + 10%. 6.42 4 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges DC Electrical Characteristics Over the Operating Temperature and Supply Voltage Range (VCC = 5.0V ± 10%) 709089S/L Symbol |ILI| |ILO| VOL VOH Parameter Input Leakage Current (1) Test Conditions VCC = 5.5V, VIN = 0V to V CC Min. ___ Max. 10 10 0.4 ___ Unit µA µA V V 3242 tbl 08 Output Leakage Current Output Low Voltage Output High Voltage CE0 = VIH o r CE1 = VIL, VOUT = 0V to V CC IOL = +4mA IOH = -4mA ___ ___ 2.4 NOTE: 1. At Vcc < 2.0V input leakages are undefined. DC Electrical Characteristics Over the Operating Temperature and Supply Voltage Range(6,7) (VCC = 5V ± 10%) 709089X9 Com'l Only Symbol ICC Parameter Dynamic Operating Current (Both Ports Active) Test Condition Version COM'L IND COM'L IND ISB2 Standby Current (One Port - TTL Level Inputs) S L S L S L S L S L S L S L S L S L S L Typ.(4) 210 210 ____ ____ 709089X12 Com'l Only Typ.(4) 200 200 ____ ____ 709089X15 Com'l Only Typ.(4) 190 190 ____ ____ Max. 390 350 ____ ____ Max. 345 305 ____ ____ Max. 325 285 ____ ____ Unit mA CEL and C ER= VIL Outputs Open f = fMAX(1) ISB1 Standby Current (Both Ports - TTL Level Inputs) CEL = C ER = VIH f = fMAX(1) 50 50 ____ ____ 135 115 ____ ____ 50 50 ____ ____ 100 90 ____ ____ 50 50 ____ ____ 110 90 ____ ____ mA Active Port Outputs Open, f=fMAX(1) Both Ports C ER and CEL > VCC - 0.2V VIN > VCC - 0.2V or VIN < 0.2V, f = 0(2) CE"A" = VIL and CE"B" = VIH(3) COM'L IND COM'L IND COM'L IND 140 140 ____ ____ 270 240 ____ ____ 130 130 ____ ____ 230 200 ____ ____ 120 120 ____ ____ 220 190 ____ ____ mA ISB3 Full Standby Current (Both Ports CMOS Level Inputs) 1.0 0.2 ____ ____ 15 5 ____ ____ 1.0 0.2 ____ ____ 15 5 ____ ____ 1.0 0.2 ____ ____ 15 5 ____ ____ mA ISB4 Full Standby Current (One Port CMOS Level Inputs) VIN > VCC - 0.2V or VIN < 0.2V, Active Port Outputs Open, f = fMAX(1) CE"A" < 0.2V and CE"B" > VCC - 0.2V(5) 130 130 ____ ____ 245 225 ____ ____ 120 120 ____ ____ 205 185 ____ ____ 110 110 ____ ____ 195 175 ____ ____ mA 3242 tbl 09 NOTES: 1. At f = fMAX, address and control lines (except Output Enable) are cycling at the maximum frequency clock cycle of 1/tCYC, using "AC TEST CONDITIONS" at input levels of GND to 3V. 2. f = 0 means no address, clock, or control lines change. Applies only to input at CMOS level standby. 3. Port "A" may be either left or right port. Port "B" is the opposite from port "A". 4. Vcc = 5V, TA = 25°C for Typ, and are not production tested. ICC DC(f=0) = 150mA (Typ). 5. CEX = VIL means CE0X = VIL and CE1X = VIH CEX = VIH means CE0X = VIH or CE1X = VIL CEX < 0.2V means CE0X < 0.2V and CE1X > VCC - 0.2V CEX > VCC - 0.2V means CE0X > VCC - 0.2V or CE1X < 0.2V "X" represents "L" for left port or "R" for right port. 6. 'X' in part numbers indicate power (S or L). 7. Industrial temperature: for specific speeds, packages and powers contact your sales office. 5 6.42 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges AC Test Conditions Input Pulse Levels Input Rise/Fall Times Input Timing Reference Levels Output Reference Levels Output Load GND to 3.0V 3ns Max. 1.5V 1.5V Figures 1,2 and 3 3242 tbl 10 5V 893Ω DATAOUT 347Ω 30pF DATAOUT 347Ω 5V 893Ω 5pF* 3242 drw 04 3242 drw 05 Figure 1. AC Output Test load. Figure 2. Output Test Load (For tCKLZ, tCKHZ, tOLZ, and tOHZ). *Including scope and jig. 8 7 6 tCD1, tCD2 (Typical, ns) 5 4 3 2 1 0 -1 -10 pF is the I/O capacitance of this device, and 30pF is the AC Test Load Capacitance 20 40 60 80 100 120 140 160 180 200 Capacitance (pF) 3242 drw 06 , Figure 3. Typical Output Derating (Lumped Capacitive Load). 6.42 6 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges AC Electrical Characteristics Over the Operating Temperature Range (Read and Write Cycle Timing)(3,4,5) (VCC = 5V ± 10%, TA = 0°C to +70°C) 709089X9 Com'l Only Symbol tCYC1 tCYC2 tCH1 tCL1 tCH2 tCL2 tR tF tSA tHA tSC tHC tSW tHW tSD tHD tSAD tHAD tSCN tHCN tSRST tHRST tOE tOLZ tOHZ tCD1 tCD2 tDC tCKHZ tCKLZ Clock Cycle Time (Flow-Through) Clock Cycle Time (Pipelined) (2) (2) 709089X12 Com'l Only Min. 30 20 12 12 8 8 ____ 709089X15 Com'l Only Min. 35 25 12 12 10 10 ____ Parameter Min. 25 15 12 12 6 6 ____ Max. ____ Max. ____ Max. ____ Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ____ ____ ____ Clock High Time (Flow-Through)(2) Clock Low Time (Flow-Through) Clock High Time (Pipelined) Clock Low Time (Pipelined) Clock Rise Time Clock Fall Time Address Setup Time Address Hold Time Chip Enable Setup Time Chip Enable Hold Time R/W Setup Time R/W Hold Time Input Data Setup Time Input Data Hold Time (2) (2) ____ ____ ____ ____ ____ ____ ____ ____ ____ (2) ____ ____ ____ 3 3 ____ 3 3 ____ 3 3 ____ ____ ____ ____ 4 1 4 1 4 1 4 1 4 1 4 1 4 1 ____ 4 1 4 1 4 1 4 1 4 1 4 1 4 1 ____ 4 1 4 1 4 1 4 1 4 1 4 1 4 1 ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ADS Setup Time ADS Hold Time CNTEN Setup Time CNTEN Hold Time CNTRST Setup Time CNTRST Hold Time Output Enable to Data Valid Output Enable to Output Low-Z(1) Output Enable to Output High-Z(1) Clock to Data Valid (Flow-Through) Clock to Data Valid (Pipelined) (2) (2) ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ 12 ____ 12 ____ 15 ____ 2 1 ____ 2 1 ____ 2 1 ____ 7 20 9 ____ 7 25 12 ____ 7 30 15 ____ ____ ____ ____ Data Output Hold After Clock High Clock High to Output High-Z (1) 2 2 2 2 2 2 2 2 2 9 ____ 9 ____ 9 ____ Clock High to Output Low-Z(1) Port-to-Port Delay tCWDD tCCS Write Port Clock High to Read Data Delay Clock-to-Clock Setup Time ____ 40 15 ____ 40 15 ____ 50 20 ns ns 3242 tbl 11 ____ ____ ____ NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). This parameter is guaranteed by device characterization, but is not production tested. 2. The Pipelined output parameters (tCYC2, tCD2) apply to either or both left and right ports when FT/PIPE = VIH. Flow-through parameters (tCYC1, tCD1) apply when FT/PIPE = VIL for that port. 3. All input signals are synchronous with respect to the clock except for the asynchronous Output Enable (OE) and FT/PIPE. FT/PIPE should be treated as a DC signal, i.e. steady state during operation. 4. 'X' in part number indicates power rating (S or L). 5. Industrial temperature: for specific speeds, packages and powers contact your sales office. 7 6.42 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Timing Waveform of Read Cycle for Flow-Through Output (FT/PIPE"X" = VIL)(3,6) tCYC1 tCH1 CLK tCL1 CE0 tSC CE1 tHC tSC (4) tHC R/W tSW tSA tHW tHA An + 1 tCD1 tDC Qn tCKLZ (1) ADDRESS (5) An An + 2 An + 3 tCKHZ (1) DATAOUT Qn + 1 tOHZ (1) Qn + 2 tOLZ (1) tDC OE (2) tOE 3242 drw 07 Timing Waveform of Read Cycle for Pipelined Output (FT/PIPE"X" = VIH)(3,6) tCYC2 tCH2 CLK tCL2 CE0 tSC CE1 tHC tSC (4) tHC R/W tSW tSA tHW tHA An + 1 (1 Latency) tCD2 Qn tCKLZ (1) ADDRESS(5) An An + 2 tDC Qn + 1 An + 3 DATAOUT Qn + 2 (1) tOHZ tOLZ (1) OE (2) tOE NOTES: 3242 drw 08 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. OE is asynchronously controlled; all other inputs are synchronous to the rising clock edge. 3. ADS = VIL, CNTEN and CNTRST = VIH. 4. The output is disabled (High-Impedance state) by CE0 = VIH or CE1 = VIL following the next rising edge of clock. Refer to Truth Table 1. 5. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 6. "X" denotes Left or Right port. The diagram is with respect to that port. 6.42 8 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Timing Waveform of a Bank Select Pipelined Read(1,2) tCH2 CLK tSA ADDRESS(B1) tSC tHA A0 tHC tSC tCD2 DATAOUT(B1) tSA ADDRESS(B2) tHA A0 A1 A2 A3 A4 A5 A6 Q0 tDC tHC tCD2 tCKHZ Q1 tDC (3) tCYC2 tCL2 A1 A2 A3 A4 A5 A6 +-0(B1) tCD2 Q3 tCKLZ (3) tCKHZ (3) tSC tHC +-0(B2) tSC tHC tCD2 tCKHZ Q2 (3) tCD2 tCKLZ (3) 3242 drw 09 DATAOUT(B2) tCKLZ (3) Q4 Timing Waveform of a Bank Select Flow-Through Read(6,7) tCH1 CLK tSA ADDRESS(B1) tSC tHA A0 tHC tSC tHC tCD1 DATAOUT(B1) tSA ADDRESS(B2) tHA A0 A1 A2 A3 A4 A5 A6 D0 tDC tCD1 D1 tDC tCKLZ (1) tCYC1 tCL1 A1 A2 A3 A4 A5 A6 CE0(B1) tCKHZ (1) tCD1 D3 tCKHZ (1) tCD1 D5 tCKLZ (1) tSC tHC CE0(B2) tSC tHC tCD1 tCKHZ D2 tCKLZ (1) tCD1 (1) tCKHZ D4 (1) DATAOUT(B2) tCKLZ (1) 3242 drw 09a NOTES: 1. B1 Represents Bank #1; B2 Represents Bank #2. Each Bank consists of one 709089 for this waveform, and are setup for depth expansion in this example. ADDRESS(B1) = ADDRESS(B2) in this situation. 2. OE and ADS = VIL; CE1(B1), CE1(B2), R/W, CNTEN, and CNTRST = VIH. 3. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 4. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 5. OE = VIL for the Right Port, which is being read from. OE = VIH for the Left Port, which is being written to. 6. If tCCS < maximum specified, then data from right port READ is not valid until the maximum specified for tCWDD. If tCCS > maximum specified, then data from right port READ is not valid until tCCS + tCD1. tCWDD does not apply in this case. 7. All timing is the same for both Left and Right ports. Port "A" may be either Left or Right port. Port "B" is the opposite of Port "A". 9 6.42 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Timing Waveform with Port-to-Port Flow-Through Read(1,2,3,5) CLK "A" tSW R/W"A" tSA ADDRESS"A" tHA NO MATCH tHW MATCH tSD DATAIN"A" tHD VALID tCCS CLK"B" (4) tCD1 R/W"B" tSW tHW tSA ADDRESS"B" tHA NO MATCH MATCH tCWDD DATAOUT"B" tDC (4) tCD1 VALID VALID tDC 3242 drw 10 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 3. OE = VIL for the Right Port, which is being read from. OE = VIH for the Left Port, which is being written to. 4. If tCCS < maximum specified, then data from right port READ is not valid until the maximum specified for tCWDD. If tCCS > maximum specified, then data from right port READ is not valid until tCCS + tCD1. tCWDD does not apply in this case. 5. All timing is the same for both Left and Right ports. Port "A" may be either Left or Right port. Port "B" is the opposite of Port "A". 6.42 10 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Timing Waveform of Pipelined Read-to-Write-to-Read (OE = VIL)(3) tCYC2 tCH2 tCL2 CLK CE0 tSC tHC CE1 tSW tHW R/W tSW tHW ADDRESS (4) An tSA tHA An +1 An + 2 An + 2 tSD tHD Dn + 2 An + 3 An + 4 DATAIN (2) tCD2 Qn READ tCKHZ (1) tCKLZ (1) tCD2 Qn + 3 DATAOUT NOP (5) WRITE READ 3242 drw 11 Timing Waveform of Pipelined Read-to-Write-to-Read (OE Controlled)(3) tCH2 CLK tCYC2 tCL2 CE0 tSC CE1 tSW tHW R/W tSW tHW tHC ADDRESS (4) An tSA tHA An +1 An + 2 tSD tHD An + 3 An + 4 An + 5 DATAIN (2) tCD2 Qn tOHZ(1) Dn + 2 Dn + 3 tCKLZ(1) tCD2 Qn + 4 DATAOUT OE READ WRITE READ 3242 drw 12 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. Output state (High, Low, or High-impedance) is determined by the previous cycle control signals. 3. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. "NOP" is "No Operation." Data in memory at the selected address may be corrupted and should be re-written to guarantee data integrity. 11 6.42 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Timing Waveform Flow-Through Read-to-Write-to-Read (OE = VIL)(3) tCH1 CLK tCYC1 tCL1 CE0 tSC CE1 tSW tHW R/W tSW tHW tHC ADDRESS (4) tSA DATAIN (2) An tHA An +1 An + 2 An + 2 tSD tHD Dn + 2 An + 3 An + 4 tCD1 Qn tDC READ tCD1 Qn + 1 tCKHZ (5) NOP (1) tCD1 Qn + 3 tCKLZ WRITE (1) tCD1 DATAOUT tDC READ 3242 drw 13 Timing Waveform of Flow-Through Read-to-Write-to-Read (OE Controlled)(3) tCYC1 tCH1 CLK tCL1 CE0 tSC CE1 tSW tHW R/W tSW tHW tHC ADDRESS (4) tSA DATAIN (2) An tHA An +1 An + 2 tSD tHD Dn + 2 An + 3 An + 4 An + 5 Dn + 3 tCD1 Qn tDC tOE tCD1 (1) tCD1 Qn + 4 tDC DATAOUT tOHZ OE READ (1) tCKLZ WRITE READ 3242 drw 14 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. Output state (High, Low, or High-impedance is determined by the previous cycle control signals. 3. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. "NOP" is "No Operation." Data in memory at the selected address may be corrupted and should be re-written to guarantee data integrity. 6.42 12 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Timing Waveform of Pipelined Read with Address Counter Advance(1) tCH2 CLK tSA ADDRESS tHA tCYC2 tCL2 An tSAD tHAD ADS tSAD tHAD CNTEN tCD2 DATAOUT Qx - 1(2) Qx tDC READ EXTERNAL ADDRESS READ WITH COUNTER Qn tSCN tHCN Qn + 1 Qn + 2(2) Qn + 3 COUNTER HOLD READ WITH COUNTER 3242 drw 15 Timing Waveform of Flow-Through Read with Address Counter Advance(1) tCYC1 tCH1 CLK tSA ADDRESS An tSAD tHAD tHA tCL1 ADS tSAD tHAD tSCN tHCN CNTEN tCD1 DATAOUT Qx(2) tDC READ EXTERNAL ADDRESS READ WITH COUNTER COUNTER HOLD READ WITH COUNTER 3242 drw 16 Qn Qn + 1 Qn + 2 Qn + 3(2) Qn + 4 NOTES: 1. CE0 and OE = VIL; CE1, R/W, and CNTRST = VIH. 2. If there is no address change via ADS = VIL (loading a new address) or CNTEN = VIL (advancing the address), i.e. ADS = VIH and CNTEN = VIH, then the data output remains constant for subsequent clocks. 13 6.42 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Timing Waveform of Write with Address Counter Advance (Flow-Through or Pipelined Outputs)(1) tCH2 CLK tSA ADDRESS tHA tCYC2 tCL2 An INTERNAL(3) ADDRESS tSAD tHAD An(7) An + 1 An + 2 An + 3 An + 4 ADS CNTEN tSD tHD DATAIN Dn WRITE EXTERNAL ADDRESS Dn + 1 Dn + 1 Dn + 2 Dn + 3 Dn + 4 WRITE WRITE WITH COUNTER COUNTER HOLD WRITE WITH COUNTER 3242 drw 17 Timing Waveform of Counter Reset (Pipelined Outputs)(2) tCH2 CLK tSA tHA (4) tCYC2 tCL2 ADDRESS INTERNAL(3) ADDRESS R/W Ax (6) An An + 1 An + 2 0 tSW tHW 1 An An + 1 ADS tSAD tHAD CNTEN tSCN tHCN tSRST tHRST CNTRST DATAIN (5) tSD tHD D0 Q0 Q1 READ ADDRESS n READ ADDRESS n+1 Qn DATAOUT COUNTER RESET (6) WRITE ADDRESS 0 READ ADDRESS 0 READ ADDRESS 1 3242 drw 18 NOTES: 1. CE0 and R/W = VIL; CE1 and CNTRST = VIH. 2. CE0 = VIL; CE1 = VIH. 3. The "Internal Address" is equal to the "External Address" when ADS = VIL and equals the counter output when ADS = VIH. 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. Output state (High, Low, or High-impedance) is determined by the previous cycle control signals. 6. No dead cycle exists during counter reset. A READ or WRITE cycle may be coincidental with the counter reset. ADDR0 will be accessed. Extra cycles are shown here simply for clarification. 7. CNTEN = VIL advances Internal Address from ‘An’ to ‘An +1’. The transition shown indicates the time required for the counter to advance. The ‘An +1’Address is written to during this cycle. 6.42 14 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Functional Description The IDT709089 provides a true synchronous Dual-Port Static RAM interface. Registered inputs provide minimal set-up and hold times on address, data, and all critical control inputs. All internal registers are clocked on the rising edge of the clock signal, however, the self-timed internal write pulse is independent of the LOW to HIGH transition of the clock signal. An asynchronous output enable is provided to ease asynchronous bus interfacing. Counter enable inputs are also provided to stall the operation of the address counters for fast interleaved memory applications. A HIGH on CE0 or a LOW on CE1 for one clock cycle will power down the internal circuitry to reduce static power consumption. Multiple chip enables allow easier banking of multiple IDT709089's for depth expansion configurations. When the Pipelined output mode is enabled, two cycles are required with CE0 LOW and CE1 HIGH to reactivate the outputs. Depth and Width Expansion The IDT709089 features dual chip enables (refer to Truth Table I) in order to facilitate rapid and simple depth expansion with no requirements for external logic. Figure 4 illustrates how to control the various chip enables in order to expand two devices in depth. The 709089 can also be used in applications requiring expanded width, as indicated in Figure 4. Since the banks are allocated at the discretion of the user, the external controller can be set up to drive the input signals for the various devices as required to allow for 16-bit or wider applications. A15 IDT709089 CE0 CE1 VCC IDT709089 CE0 CE1 VCC Control Inputs Control Inputs IDT709089 CE1 IDT709089 CE1 CE0 Control Inputs Control Inputs CE0 3242 drw 19 Figure 4. Depth and Width Expansion with IDT709089 CNTRST CLK ADS CNTEN R/W OE 15 6.42 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Ordering Information IDT XXXXX Device Type A Power 99 Speed A Package A Process/ Temperature Range Blank I(1) Commercial (0°C to +70°C) Industrial (-40°C to +85°C) PF 100-pin TQFP (PN100-1) 9 12 15 S L Commercial Only Commercial Only Commercial Only Standard Power Low Power Speed in nanoseconds 709089 512K (64K x 8-Bit) Synchronous Dual-Port RAM 3242 drw 20A NOTE: 1. Industrial temperature range is available. For specific speeds, packages and powers contact your sales office. Ordering Information for Flow-through Devices Old Flow-through Part 70908S/L20 70908S/L25 70908S/L30 New Combined Part 709089S/L9 709089S/L12 709089S/L15 3242 tbl 12 Preliminary Datasheet: "PRELIMINARY' datasheets contain descriptions for products that are in early release. 6.42 16 IDT709089S/L High-Speed 64K x 8 Synchronous Dual-Port Static RAM Preliminary Industrial and Commercial Temperature Ranges Datasheet Document History 1/12/99: Initiated datasheet document history Converted to new format Cosmetic and typographical corrections Added additional notes to pin configurations Page 15 Added Depth and Width Expansion note Changed drawing format Page 4 Deleted note 6 for Table II Replaced IDT logo Page 1 Removed "Separate upper-byte..." line Combined Pipelined 709089 family and Flow-through 70908 family offerings into one data sheet Changed ±200mV in waveform notes to 0mV Added corrresponding part chart with ordering information Pages 8 and 9 Changed ±220mV waveform notes to 0mV Page 9 Changed "Operation" in heading to "Pipelined Output", fixed drawing 08 Removed PGA pin 6/7/99: 11/10/99: 12/22/99: 1/12/00: 2/18/00: CORPORATE HEADQUARTERS 2975 Stender Way Santa Clara, CA 95054 for SALES: 800-345-7015 or 408-727-6116 fax: 408-492-8674 www.idt.com for Tech Support: 831-754-4613 DualPortHelp@idt.com The IDT logo is a registered trademark of Integrated Device Technology, Inc. 17 6.42
IDT709089 价格&库存

很抱歉,暂时无法提供与“IDT709089”相匹配的价格&库存,您可以联系我们找货

免费人工找货