FEATURES
Multiple Case Sizes - High Voltage – High Current
APPLICATIONS
Filtering – Switching Power Supplies
Operating Temperature
Range
-40°C to +85°C (10VDC to 250VDC)
-25°C to +85°C (350VDC to 500VDC)
+20% at 120 Hz, 20°C
Capacitance Tolerance
Surge Voltage
Dissipation
Factor
(120 Hz)
WVDC
SVDC
WVDC
10
16
25
35
50
63
80
100
160
200
250
350
400
450
500
13
10
20
16
32
25
44
35
63
50
79
63
100
80
120
100
200
160
250
200
300
250
400
350
450
400
500
450
550
500
tan δ
.55
.5
.45
.4
.35
.3
.25
.2
.15
.15
.15
.15
.15
.2
.2
For capacitance values above 33000μF
the following to the Dissipation factors values above
Leakage Current
@20°C, Rated WVDC
applied
Impedance
Ratio
(120 Hz)
(capacitance-33000 μF)*0.1 add
10000 μF
5 Minutes
3√CV
Time
WVDC
10
16
25
35
50
63
80
100
160
200
250
350
400
450
500
-25°C/+20°C
4
4
4
4
4
4
4
4
3
3
3
3
8
8
8
-40°C/+20°C
15
15
15
15
15
15
15
15
15
15
15
-
-
-
-
2000 hours with rated voltage applied at 85°C with full rated ripple current applied