BAS21...
Silicon Switching Diode • For high-speed switching applications • High breakdown voltage • Pb-free (RoHS compliant) package 1) • Qualified according AEC Q101
BAS21
!
BAS21-03W
BAS21U
$ # "
, , ,!
!
Type BAS21 BAS21-03W BAS21U
Parameter Diode reverse voltage Peak reverse voltage Forward current Peak forward current Peak forward current
Package SOT23 SOD323 SC74
Configuration single single parallel triple
Symbol VR VRM IF IFM IFM IFS IFSM Ptot 350 250 250 Tj Tstg 150 -65 ... 150 Value 200 250 250 625 625 4 -
Marking JSs D JSs
Unit V mA mA A mW
Maximum Ratings at TA = 25°C, unless otherwise specified
Surge forward current, t = 10 µs Non-repetitive peak surge forward current Total power dissipation BAS21, T S ≤ 70°C BAS21-03W, TS ≤ 124°C BAS21U, TS ≤ 122°C Junction temperature Storage temperature
1Pb-containing
°C
package may be available upon special request
1
2007-04-19
BAS21...
Thermal Resistance Parameter Junction - soldering point 1) BAS21 BAS21-03W BAS21U
Symbol
RthJS
Value ≤ 230 ≤ 105 ≤ 110
Unit K/W
Electrical Characteristics at TA = 25°C, unless otherwise specified Parameter Symbol Values Unit min. typ. max. DC Characteristics 250 V Breakdown voltage V(BR) I(BR) = 100 µA Reverse current VR = 200 V VR = 200 V, TA = 150 °C Forward voltage IF = 100 mA IF = 200 mA
AC Characteristics Diode capacitance VR = 0 V, f = 1 MHz Reverse recovery time IF = 30 mA, IR = 30 mA, measured at IR = 3mA, RL = 100 Ω Test circuit for reverse recovery time
D.U.T.
IR VF CT trr -
µA -
0.1 100 V 1 1.25
5 50 pF ns
Puls generator: tp = 1µs, D = 0.05 tr = 0.6ns, Ri = 50Ω
Oscillograph
ΙF
Oscillograph: R = 50Ω , tr = 0.35ns, C ≤ 1pF
EHN00018
1For
calculation of RthJA please refer to Application Note Thermal Resistance
2
2007-04-19
BAS21...
Reverse current IR = ƒ (TA) VR = 200V
10 2 µA
BAS 19...21 EHB00027
Forward Voltage VF = ƒ (TA) IF = Parameter
1.5 V
BAS 19...21 EHB00029
ΙR
10 1 5 max
VF
Ι F = 625 mA
1.0
typ.
250 mA 100 mA 10 mA
10 0 5
0.5
10 -1 5
10 -2
0
50
100 TA
˚C
150
0.0
0
50
100 TA
˚C
150
Forward current IF = ƒ (VF)
Forward current IF = ƒ (T S) BAS21-03W
ΙF
800 mA 700 600
BAS 19...21
EHB00028
300
mA
200
400 300
IF
150 100 50 0 0
500
200 100 0
0.0
0.5
1.0
V VF
1.5
15
30
45
60
75
90 105 120 °C
150
TS
3
2007-04-19
BAS21...
Forward current IF = ƒ (T S) BAS21U Permissible Puls Load R thJS = ƒ (tp) BAS21
10 3
250
mA
10 2
150
RthJS
10 1
IF
100
10 0 50
D = 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0
0 0
15
30
45
60
75
90 105 120 °C
150
10 -1 -6 10
10
-5
10
-4
10
-3
10
-2
s
10
0
TS
tP
Permissible Pulse Load IFmax / I FDC = ƒ (tp ) BAS21
10 2
Permissible Puls Load R thJS = ƒ (tp) BAS21-03W
10 3
K/W
IFmax/IFDC
10 1
D=0 0.005 0.01 0.02 0.05 0.1 0.2 0.5
10 2
RthJS
10 1
10 0
D=0.5 0.2 0.1 0.05 0.02 0.01 0.005 0
10 0 -6 10
10
-5
10
-4
10
-3
10
-2
s
10
0
10 -1 -6 10
10
-5
10
-4
10
-3
10
-2
s
10
0
tP
tP
4
2007-04-19
BAS21...
Permissible Pulse Load IFmax / I FDC = ƒ (tp ) BAS21-03W
10 2 10 3
K/W
Permissible Puls Load R thJS = ƒ (tp) BAS21U
10 1
D=0 0.005 0.01 0.02 0.05 0.1 0.2 0.5
I Fmax/IFDC
10 2
RthJS
10 1
10 0
D=0.5 0.2 0.1 0.05 0.02 0.01 0.005 0
10 0 -6 10
10
-5
10
-4
10
-3
10
-2
s
10
0
10 -1 -6 10
10
-5
10
-4
10
-3
10
-2
s
10
0
tP
tP
Permissible Pulse Load IFmax / I FDC = ƒ (tp ) BAS21U
10 2
IFmax/IFDC
10 1
D=0 0.005 0.01 0.02 0.05 0.1 0.2 0.5
10 0 -6 10
10
-5
10
-4
10
-3
10
-2
s
10
0
tP
5
2007-04-19
Package SC74
BAS21...
Package Outline
2.9 ±0.2 (2.25) B (0.35)
2.5 ±0.1
6 5 4
1.1 MAX. 0.15 +0.1 -0.06
0.25 ±0.1 1.6 ±0.1
10˚ MAX.
1
2
3
Pin 1 marking 1.9
0.35 +0.1 -0.05 0.95
10˚ MAX.
0.2
M
B 6x 0.2
M
A
0.1 MAX. A
Foot Print
0.5
0.95
Marking Layout (Example)
Small variations in positioning of Date code, Type code and Manufacture are possible.
1.9
2.9
Manufacturer
2005, June Date code (Year/Month)
Pin 1 marking Laser marking
BCW66H Type code
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel For symmetric types no defined Pin 1 orientation in reel.
4
0.2
Pin 1 marking
3.15
2.7 8
1.15
6
2007-04-19
Package SOD323
BAS21...
Package Outline
0.9 +0.2 -0.1
+0.2 1.25 -0.1
0 ±0.05 A
1.7 +0.2 -0.1
+0.05 0.3 -0.2
2 Cathode marking 1 0.3 +0.1 -0.05 0.25 M A
0.45 ±0.15 2.5 ±0.2
0.15 +0.1 -0.06
Foot Print
0.6
Marking Layout (Example)
0.8
1.7
0.8
BAR63-03W Type code Cathode marking Laser marking
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel
4
0.2
2 2.9 8
Cathode marking
0.65 1.35
1
7
2007-04-19
Package SOT23
BAS21...
Package Outline
0.15 MIN.
1 ±0.1 0.1 MAX.
1.3 ±0.1
2.9 ±0.1
3
B
2.4 ±0.15
10˚ MAX.
0.4 +0.1 -0.05
1)
1
2
10˚ MAX.
C 0.95 1.9
0.08...0.1
A
5
0...8˚
0.25 M B C
0.2
M
A
1) Lead width can be 0.6 max. in dambar area
Foot Print
0.8
0.9
0.8
1.2
Marking Layout (Example)
Manufacturer
EH s
Pin 1
0.9
1.3
2005, June Date code (YM)
BCW66 Type code
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel
4 0.9
2.13 2.65
0.2
8
Pin 1
3.15
1.15
8
2007-04-19
BAS21...
Edition 2006-02-01 Published by Infineon Technologies AG 81726 München, Germany © Infineon Technologies AG 2007. All Rights Reserved.
Attention please! The information given in this dokument shall in no event be regarded as a guarantee of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office ( www.infineon.com ). Warnings Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.
9
2007-04-19
很抱歉,暂时无法提供与“BAS21U”相匹配的价格&库存,您可以联系我们找货