BAW156...
Silicon Low Leakage Diode • Low-leakage applications • Medium speed switching times • Common anode configuration • Pb-free (RoHS compliant) package 1) • Qualified according AEC Q101
BAW156
!
,
,
Type BAW156
Parameter Diode reverse voltage Peak reverse voltage Forward current
Package SOT23
Configuration common anode
Symbol VR VRM IF IFSM 4.5 0.5 Ptot Tj Tstg 250 150 -65 ... 150 Value 80 85 200
Marking JZs
Unit V mA A
Maximum Ratings at TA = 25°C, unless otherwise specified
Non-repetitive peak surge forward current t = 1 µs t=1s Total power dissipation Ts ≤ 31°C Junction temperature Storage temperature
mW °C
Thermal Resistance Parameter Junction - soldering point 2) BAW156
1Pb-containing 2For
Symbol RthJS
Value ≤ 360
Unit K/W
package may be available upon special request calculation of RthJA please refer to Application Note Thermal Resistance
1
2007-04-20
BAW156...
Electrical Characteristics at TA = 25°C, unless otherwise specified Symbol Values Unit Parameter min. typ. max. DC Characteristics 85 V Breakdown voltage V(BR) I(BR) = 100 µA Reverse current VR = 75 V VR = 75 V, TA = 150 °C Forward voltage IF = 1 mA IF = 10 mA IF = 50 mA IF = 150 mA
AC Characteristics Diode capacitance VR = 0 V, f = 1 MHz Reverse recovery time IF = 10 mA, IR = 10 mA, measured at IR = 1mA, RL = 100 Ω Test circuit for reverse recovery time
D.U.T.
IR VF 900 1000 1100 1250 5 80
nA
mV
CT trr
-
2 0.6
1.5
pF µs
Pulse generator: tp = 10µs, D = 0.05, tr = 0.6ns, Ri = 50Ω
Oscillograph
ΙF
Oscillograph: R = 50Ω, tr = 0.35ns, C ≤ 1pF
EHN00019
2
2007-04-20
BAW156...
Reverse current IR = ƒ (TA) VR = 70V
10 2
BAW 156 EHB00106
Forward Voltage VF = ƒ (TA) IF = Parameter
1.5 V
BAW 156 EHB00109
ΙR
nA 10 1 max
VF
1.0
Ι F = 150 mA
50 mA 10 mA 1 mA
10 0
10 -1
typ
0.5
0.1 mA
10 -2
10 -3
0
0
50
100
˚C TA
150
0
50
100 TA
˚C
150
Forward current IF = ƒ (VF) TA = 25°C
150
BAW 156 EHB00107
Forward current IF = ƒ (T S) BAW156
250
mA
ΙF
mA
200 175
IF
100
150 125 100
typ
max
50
75 50 25
0
0
0.5
1.0
V VF
1.5
0 0
15
30
45
60
75
90 105 120 °C
TS
150
3
2007-04-20
BAW156...
Permissible Puls Load RthJS = ƒ (tp) Permissible Pulse Load IFmax / I FDC = ƒ (t p)
10 3 10 2
10 2
I Fmax/IFDC
-
10 1
10 0
D = 0,5 0,2 0,1 0,05 0,02 0,01 0,005 0
10 1
D=0 0.005 0.01 0.02 0.05 0.1 0.2 0.5
RthJS
10 -1 -7 10
10
-6
10
-5
10
-4
10
-3
10
-2
s
10
0
10 0 -6 10
10
-5
10
-4
10
-3
10
-2
s
10
0
TP
TP
4
2007-04-20
Package SOT23
BAW156...
Package Outline
0.15 MIN.
1 ±0.1 0.1 MAX.
1.3 ±0.1
2.9 ±0.1
3
B
2.4 ±0.15
10˚ MAX.
0.4 +0.1 -0.05
1)
1
2
10˚ MAX.
C 0.95 1.9
0.08...0.1
A
5
0...8˚
0.25 M B C
0.2
M
A
1) Lead width can be 0.6 max. in dambar area
Foot Print
0.8
0.9
0.8
1.2
Marking Layout (Example)
Manufacturer
EH s
Pin 1
0.9
1.3
2005, June Date code (YM)
BCW66 Type code
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel
4 0.9
2.13 2.65
0.2
8
Pin 1
3.15
1.15
5
2007-04-20
BAW156...
Edition 2006-02-01 Published by Infineon Technologies AG 81726 München, Germany © Infineon Technologies AG 2007. All Rights Reserved.
Attention please! The information given in this dokument shall in no event be regarded as a guarantee of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office ( www.infineon.com ). Warnings Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.