0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BCR400W_07

BCR400W_07

  • 厂商:

    INFINEON

  • 封装:

  • 描述:

    BCR400W_07 - Active Bias Controller - Infineon Technologies AG

  • 数据手册
  • 价格&库存
BCR400W_07 数据手册
BCR400W Active Bias Controller Characteristics • Supplies stable bias current even at low battery voltage and extreme ambient temperature variation • Low voltage drop of 0.7V Application notes • Stabilizing bias current of NPN transistors and FET's from less than 0.2mA up to more than 200mA • Ideal supplement for Sieget and other transistors • also usable as current source up to 5mA • Pb-free (RoHS compliant) package1) • Qualified according AEC Q101 1 2 EHA07188 3 4 1 2 4 3 Type BCR400W Marking Pin Configuration W4s 1=GND/ENPN 2=Contr/BNPN 3VS Package 4=Rext/CNPN SOT343 (ENPN, BNPN, CNPN are electrodes of a stabilized NPN transistor) Maximum Ratings Parameter Source voltage Control current Control voltage Reverse voltage between all terminals Total power dissipation, TS = 117 °C Junction temperature Storage temperature Thermal Resistance Junction - soldering point2) RthJS ≤ 100 Symbol VS IContr. VContr. VR Ptot Tj Tstg Value 18 10 16 0.5 330 150 -65 ... 150 Unit V mA V mW °C K/W 1Pb-containing package may be available upon special request 2For calculation of R please refer to Application Note Thermal Resistance thJA 1 2007-05-29 BCR400W Electrical Characteristics at TA=25°C, unless otherwise specified Parameter DC Characteristics Additional current consumption VS = 3 V Lowest stabilizing current VS = 3 V DC Characteristics with stabilized NPN-Transistors Lowest sufficient battery voltage IB (NPN) < 0.5mA Voltage drop (VS - VCE) IC = 25 mA Change of IC versus hFE hFE = 50 Change of IC versus V S VS = 3 V Change of IC versus TA ∆IC/I C 0.2 %/K ∆IC/I C 0.15 ∆IC/I C 0.08 ∆h FE / hFE ∆VS/VS Symbol min. I0 Imin - Values typ. 20 0.1 max. 40 - Unit µA mA VSmin Vdrop - 1.6 0.65 - V 2 2007-05-29 BCR400W Collector current I C = f (hFE) IC and h FE refer to stabilized NPN Transistor Parameter Rext. (Ω) 10 3 mA Collector Current I C = f (VS) of stabilized NPN Transistor Parameter Rext. (Ω) 10 3 mA 2.1 5.9 10 2 5.9 10 2 12.4 IC IC 67 10 1 67 10 1 760 10 0 760 10 0 4.3k 10 -1 0 50 100 150 200 250 - 350 10 -1 0 2 4 6 8 V 11 hFE VS Voltage drop Vdrop = f (IC ) Collector current I C = f (Rext.) of stabilized NPN Transistor 10 3 mA V 2 1.7 1.6 10 2 Vdrop 1.5 1.4 1.3 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 -2 10 10 -1 IC 10 1 10 0 0 1 2 10 10 10 mA10 3 10 -1 0 10 10 1 10 2 10 3 Ohm10 4 IC Rext. 3 2007-05-29 BCR400W Collector current TA = f (IC) of stabilized NPN Transistor Parameter: Rext. (Ω) 10 3 mA 2.2 Control current I = f (Rext.) in current source application 10 1 10 2 6 mA IC 26 10 1 65 IContr. 10 0 10 -1 -1 10 290 10 0 760 4.3k 10 -1 -40 -20 0 20 40 60 80 100 120 °C 160 10 0 10 1 10 2 KOhm 3 10 TA Rext. Control current I = f (TA) in current source application Control current I = f (V S) in current source application 1.5 mA 2.2 mA 1.2 1.8 IContr. 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 -20 0 20 40 60 80 °C IContr. 1.1 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 110 0 0 2 4 6 8 V 11 TA VS 4 2007-05-29 BCR400W Total power dissipation Ptot = f (TS ) 400 mW 300 Note that up to TS=115°C it is not possible to exceed Ptot respecting the maximum ratings of VS and IContr. The collector or drain current (respectively) of the stabilized RF transistor does not affect BCR 400 directly, as it provides just the base current. P tot 250 200 150 100 50 0 0 20 40 60 80 100 120 °C 150 TS Typical application for GaAs FET with active bias controller RF IN RF OUT 100 pF 100 k Ω BCR 400 1 4 R ext 3 2 100 k Ω - VG 1 nF +VS EHA07190 5 2007-05-29 BCR400W RF transistor controlled by BCR400 BCR 400 +V S 3 R ext. 4 Vdrop ΙC 1 2 C1 C2 Be aware that BCR400 stabilized bias current of transistors in an active control loop In order to avoid loop ascillation (hunting), time constants must be chosen adequately, i.e. C1 >= 10 x C2 RF OUT Ι contr. RF IN RF-Transistor EHA07217 RX/TX antenna switch, compatible to control logic and working at wide battery voltage range Antenna TX λ/ 4 RX BCR 400 RX TX 1 4 R ext = 100 Ω - 220 Ω 2 3 + VS > 2.7 V EHA07218 6 2007-05-29 BCR400W Low voltage reference BCR 400 1 4 2 Red LED V REF 3 +VS EHA07219 Precision timer with BCR400 providing constant charge current +VS BCR 400 3 R ext 4 1 6 2 2 78 4 3 1 5 EHA07191 Timer IC (555) 7 2007-05-29 Package SOT343 BCR400W Package Outline 2 ±0.2 1.3 4 3 0.15 1 0.3 +0.1 -0.05 4x 0.1 M +0.1 0.6 -0.05 0.9 ±0.1 0.1 MAX. 0.1 A 1.25 ±0.1 2.1 ±0.1 2 0.1 MIN. 0.15 -0.05 0.2 M +0.1 A Foot Print 0.6 0.8 1.15 0.9 Marking Layout (Example) Manufacturer 1.6 2005, June Date code (YM) Pin 1 BGA420 Type code Standard Packing Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel 4 0.2 Pin 1 2.15 2.3 8 1.1 8 2007-05-29 BCR400W Published by Infineon Technologies AG 81726 München, Germany © Infineon Technologies AG 2007. All Rights Reserved. Attention please! The information given in this data sheet shall in no event be regarded as a guarantee of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office ( www.infineon.com ). Warnings Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered. 9 2007-05-29
BCR400W_07 价格&库存

很抱歉,暂时无法提供与“BCR400W_07”相匹配的价格&库存,您可以联系我们找货

免费人工找货