BF770A
NPN Silicon RF Transistor • For IF amplifiers in TV-sat tuners and for VCR modulators • Pb-free (RoHS compliant) package 1) • Qualified according AEC Q101
3 1
2
ESD (Electrostatic discharge) sensitive device, observe handling precaution!
Type BF770A
Maximum Ratings Parameter Collector-emitter voltage Collector-emitter voltage Collector-base voltage Emitter-base voltage Collector current Base current Total power dissipation2) TS ≤ 63°C Junction temperature Ambient temperature Storage temperature Thermal Resistance Parameter Junction - soldering point 3)
1Pb-containing 2T 3For
Marking LSs
Pin Configuration 1=B 2=E 3=C
Package SOT23
Symbol VCEO VCES VCBO VEBO IC IB Ptot Tj TA T stg Symbol RthJS
Value 12 20 20 2 90 9 300 150 -65 ... 150 -65 ... 150 Value ≤ 290
Unit V
mA mW °C
Unit K/W
package may be available upon special request S is measured on the collector lead at the soldering point to the pcb calculation of RthJA please refer to Application Note Thermal Resistance
1
2007-04-20
BF770A
Electrical Characteristics at TA = 25°C, unless otherwise specified Parameter DC Characteristics Collector-emitter breakdown voltage IC = 1 mA, I B = 0 Collector-emitter cutoff current VCE = 20 V, VBE = 0 Collector-base cutoff current VCB = 10 V, I E = 0 Emitter-base cutoff current VEB = 2 V, IC = 0 DC current gainIC = 30 mA, VCE = 8 V, pulse measured hFE 70 100 140 IEBO 10 µA ICBO 100 nA ICES 100 µA V(BR)CEO 12 V Symbol min. Values typ. max. Unit
2
2007-04-20
BF770A
Electrical Characteristics at TA = 25°C, unless otherwise specified Symbol Values Unit Parameter min. typ. max. AC Characteristics (verified by random sampling) Transition frequency fT IC = 30 mA, VCE = 8 V, f = 500 MHz Collector-base capacitance VCB = 10 V, f = 1 MHz, VBE = 0 , emitter grounded Collector emitter capacitance VCE = 10 V, f = 1 MHz, VBE = 0 , base grounded Emitter-base capacitance VEB = 0.5 V, f = 1 MHz, VCB = 0 , collector grounded Noise figure IC = 5 mA, VCE = 8 V, ZS = ZSopt, f = 900 MHz f = 1.8 GHz Power gain, maximum available1) IC = 30 mA, VCE = 8 V, Z S = ZSopt, ZL = ZLopt, f = 900 MHz f = 1.8 GHz Transducer gain IC = 30 mA, VCE = 8 V, Z S = Z L = 50Ω, f = 900 MHz f = 1.8 GHz
1G
4.5 -
6 0.54
0.75
GHz pF
Ccb
Cce
-
0.25
-
Ceb
-
1.9
-
F G ma |S 21e|2 12.5 7 14.5 9.5 1.5 2.6 -
dB
dB
2 1/2 ma = |S21/S 12| (k-(k -1) )
3
2007-04-20
Package SOT23
BF770A
Package Outline
0.15 MIN.
1 ±0.1 0.1 MAX.
1.3 ±0.1
2.9 ±0.1
3
B
2.4 ±0.15
10˚ MAX.
0.4 +0.1 -0.05
1)
1
2
10˚ MAX.
C 0.95 1.9
0.08...0.1
A
5
0...8˚
0.25 M B C
0.2
M
A
1) Lead width can be 0.6 max. in dambar area
Foot Print
0.8
0.9
0.8
1.2
Marking Layout (Example)
Manufacturer
EH s
Pin 1
0.9
1.3
2005, June Date code (YM)
BCW66 Type code
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel Reel ø330 mm = 10.000 Pieces/Reel
4 0.9
2.13 2.65
0.2
8
Pin 1
3.15
1.15
4
2007-04-20
BF770A
Edition 2006-02-01 Published by Infineon Technologies AG 81726 München, Germany © Infineon Technologies AG 2007. All Rights Reserved.
Attention please! The information given in this dokument shall in no event be regarded as a guarantee of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office ( www.infineon.com ). Warnings Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.