P roduct Brief KP21x/MAP
Integrated Pressure Sensor IC f or Manifold Air Pressure Measurement A pplications
Application The manifold air pressure (MAP) is an important parameter to compute the airfuel ratio provided to the engine for lower emission due to better combustion and increased efficiency. For cost sensitive engine systems a MAP sensor show the potential to complement or even substitute mass air flow (MAF) sensors. In addition manifold pressure data can be used to compute diagnostics of leakages and malfunctions of the exhaust gas recirculation valve. In automotive applications where high production volumes are common there is substantial interest in precision, low-cost and fully integrated sensors. In this context products of the developed MAP sensor family KP21x are the optimum solution for aspirated or turbo diesel and gasoline engines management systems. Features Absolute air pressure measurement Excellent accuracy of up to 1.0 kPa over a large temperature range Ratiometric analog output Output signal fully compensated Pressure range from 15 to 150 kPa Temperature range (ambient) from -40 to +140°C SMD package (PG-DSOF-8-16) Output clamping (optional for KP216) Complete Product Family (KP214, KP215, KP216) Application Circuit for the Pressure Sensor System
5V 1 Test KP21x VDD GND VOUT GND 5 6 7 8 C1 C2 R1*) R3
Typical Application Engine control/MAP applications Industrial controls
Ref A/D IN C3
2 CLOCK/ VPROG 3 DATA IN 4 DATA OUT
ADC
R2*)
*) R1 and R2 only alternatively
Microcontroller A/D IN GND
T-Sensor MAP module
Electronic control unit (ECU)
www.infineon.com/sensors
Sensors
P roduct Brief
Highly Integrated Sensors - Single Chip
VDD
CLOCK/VPROG
DATA IN
DATA OUT
Internal Reference Voltage Temperature Compensation 1 kHz 12 bit
EEPROM (90 + 22 bits)
Test and Programming Interface
Digital Control 30 kHz VOUT
A
D
1 bit
10 bit Optional 10 bit D Linearization A Clamping
VDD Clock Generator GND
Infineon offers an extensive broad product portfolio for diesel engine management systems from micro-machined sensors to smart power ICs and microcontrollers. The KP21x pressure sensor as an integrated pressure sensor for manifold pressure measurement, is a benchmark in terms of reliability, performance and integration level. Product Summary Parameter Accuracy Pressure Range Sensitivity Supply Voltage Output Current Output Voltage Operating Temperature Programmable Transfer Functions Transfer Function Pressure Min Transfer Function Pressure Max Transfer Function Voltage Min Transfer Function Voltage Max Lower Programmable Clamping Level (KP226) Upper Programmable Clamping Level (KP226) 15 100 0.1 4.5 0.0 4.37 60 150 0.5 4.85 0.63 5.0 kPa kPa V V V V 0.1 -40 10 40 4.5 5.0 Range Min. Typ. Max. 1.0 150 88 5.5 1.0 4.85 +140 % F.S. kPa mV/kPa V mA V °C Unit
OBD
How to reach us: http://www.infineon.com Published by Infineon Technologies AG 81726 Munich, Germany © 2008 Infineon Technologies AG All Rights Reserved.
Legal Disclaimer The information given in this Product Brief shall in no event be regarded as a guarantee of conditions or characteristics. With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices, please contact the nearest Infineon Technologies Office (www.infineon.com).
Warnings Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.