User’s Manual
ISL94203EVKIT1Z
Evaluation Kit
1.
Overview
The ISL94203EVKIT1Z evaluation kit facilitates testing of the ISL94203 Li-ion battery pack monitor and control
ICs. The ISL94203 monitors cell voltage, current, and temperature. It converts the cell voltages, pack current, and
temperatures to 12-bit digital values, provides cell balance control, and provides complete stand-alone battery
pack operation.
The ISL94203 default stand-alone operation can be overridden by an external microcontroller. The PC graphical
user interface (GUI) supports the hooks needed to monitor stand-alone operation and to demonstrate operation
with an external microcontroller.
1.1
Key Features
• Status LEDs monitor RGO, EOC, SD, and PSD conditions
• Jumper configuration single or split path applications
• Wakeup push button for Exit Sleep control
• FETs off push button for quick all FETs off condition
• Cell balance LEDs for MCB process observation
• PCB layout accommodates solder braid addition for high current evaluation
• Software enables real-time observation and data collection of 14 analog measurements and 27 digital status
indicators
1.2
Specifications
• This board has been configured and optimized for the following operating conditions:
• Configurable to 3 to 8 cells, default 3 cells
• Standard cell voltage range 2.699V to 4.250V
• OV delay time of 1 second
• UV delay time of 4 seconds
• CB max delta voltage 0.501
• CB max/min voltage 4.032V and 3.100V
Note: Consult programming options for full listing of programmable parameters and ranges.
1.3
Ordering Information
Part Number
ISL94203EVKIT1Z
1.4
Description
Evaluation kit for the ISL94203
Related Literature
For a full list of related documents, visit our website:
• ISL94203 device page
1.5
What is Inside the Evaluation Kit
• ISL94203 evaluation board
• MCB_PS_Z multicell power supply test board
• ISL94203INTFACEKIT1Z USB to I2C interface kit, includes a PCB and I2C cable
• USB cable, connects PC to USB-I2C interface board
AN1952 Rev.3.00
May.9.19
Page 2 of 43
ISL94203EVKIT1Z
1.6
1. Overview
What is Needed
The following instruments are required to perform testing:
• 30V/1A adjustable power supply
• Wires to connect power supply to MCB_PS_Z board
• Precision multimeter (optional)
• Oscilloscope (optional)
• Cables and wires (optional)
1.7
Software Installation
1. Connect the ISL94203INTFACEKIT1Z to the PC through the USB port. The board should automatically
enumerate in the device control panel under Human Interface Devices. The vendor ID is 0x09AA and the
product ID is 0x2036. Because it is a HID device, no special driver is needed.
2. Copy the isl94203evkit1z-software.exe program to the PC (any desired location). Double-click to run the
installation file. Note: you might need to have “Run as Administrator” open when performing the installation.file.
1.8
Quick Hardware Setup Guide
1. Check the jumpers and switches on the board. The board should be configured as follows:
a. ADDR jumper set to 0”
b. xT2 Select jumper on either CELL or FET.
c. FET jumpers set for either one path or two path. Start with one path.
d. J4 jumper is set to 1 Path.
J9 jumper is set to 1 Path.
2. Connect the power supply to the MCB_PS_Z board. The positive terminal is J5/J11 and the negative terminal
is J8/J12. There should be a jumper on J13 as shown in Figure 2 on page 5.
3. Set the power supply voltage to 28V (3.5V per cell). (Optional: check that the voltages at terminal J1 or J3 are
3.5V per cell).
4. Turn off the power to the power supply.
5. Connect the ISL94203 board directly to the MCB_PS_Z board at connector J1. Make sure the board is
connected on the ground side of J1 (see Figure 2).
6. Turn on the power to the supply. If no LEDs light, press the WakeUp button. Notice that there is one green LED
(RGO) indicating that the LDO regulator on the ISL94203 is operating.
The voltages at various points should be:
RGO = 2.5V ±3%
VREF = 1.80V ±0.5%
7. Connect the USB port of the PC to the USB port of the ISL94203INTFACEKIT1Z interface board.
8. Connect the I2C cable from the ISL94203INTFACEKIT1Z board to the ISL94203EVKIT1Z board (J13).
9. Open the ISL94203 GUI software1.7. Use the software to read the cell voltages.
10. Compare the voltages at the board input (use a meter to measure each input voltage, because the MCB_PS_Z
board might not accurately divide the voltages into equal 3.5V steps) with the readings provided by the GUI.
These voltages should closely match.
11. See other operations described later in this document.
AN1952 Rev.3.00
May.9.19
Page 3 of 43
ISL94203EVKIT1Z
2.
2. PCB Layout Guidelines
PCB Layout Guidelines
The AC performance of this circuit depends greatly on the care taken in designing the PC board. The following
are recommendations to achieve optimum high performance from your PC board:
• The use of low inductance components, such as chip resistors and chip capacitors, is strongly recommended.
• Minimize signal trace lengths. This is especially true for the VDD, charge pump decoupling, CS1, CS2, and
VC0-VC8 inputs. Trace inductance and capacitance can easily affect circuit performance. Vias in the signal
lines add inductance at high frequency and should be avoided.
• Match channel-to-channel analog I/O trace lengths and layout symmetry. This is especially true for the CS1 and
CS2 lines, because their inputs are normally very low voltage.
• Maximize use of AC decoupled PCB layers. All signal I/O lines should be routed over continuous ground planes
(that is, no split planes or PCB gaps under these lines). Avoid vias in the signal I/O lines.
• When testing, use good quality connectors and cables, matching cable types and keep cable lengths to a
minimum.
Figure 1. ISL94203EVKIT1Z Evaluation Board
AN1952 Rev.3.00
May.9.19
Page 4 of 43
ISL94203EVKIT1Z
2. PCB Layout Guidelines
ISL94203INTFACEKIT1Z
I2C Port to
ISL94203EVKIT1Z Board
To PC USB Port
Sets Power Path (Charge/Discharge)
(1 Path or 2 Path)
Wake Up
Control
Sets CHMON
to 1 Path or 2 Path
MCB_PS_Z Board
FETSOFF
Manual Control
ISL94203EVKIT1Z
6V to 38V
I2C Port to
USB-I2C Board
Cell Balance
LEDs
Set I2C ADDR
Set xT2 Thermistor
To FET or to Cell
Figure 2. ISL94203EVKIT1Z Board Setup
AN1952 Rev.3.00
May.9.19
Page 5 of 43
ISL94203EVKIT1Z
3.
3. Quick GUI Setup Guide
Quick GUI Setup Guide
1. When the board is powered up and connected to the PC through the USB cable, start the GUI program and
click on the dropdown box.
I2C Port
to Eval Board
To PC USB Port
ISL94203INTFACEKIT1Z
MC3_PS_Z Board
Sets 1
Discharge Path
Wake Up
Control
Sets CHMON
to 1 Path
FETSOFF
Manual Control
I2C Port
to Use
USB-I2C Board
6V to 38V
ISL94203EVKIT1Z
Cell Balance LEDs
Set XT2 Thermistor
to FET or to Cell
Set I2C ADDR
Figure 3. Main GUI Start-Up Window
2. Click on Read Voltages (Single). This updates all the cell voltages, temperature and current readings, and
updates the status indicators.
3. Click on Read Pack Settings. This returns the configuration parameters set in the device.
4. Review the operation of the GUI features in the following sections.
AN1952 Rev.3.00
May.9.19
Page 6 of 43
ISL94203EVKIT1Z
3. Quick GUI Setup Guide
ISL94203EVKIT1Z
Figure 4. Main GUI Window Showing Pack Settings
AN1952 Rev.3.00
May.9.19
Page 7 of 43
ISL94203EVKIT1Z
4.
4.1
4. Using the GUI
Using the GUI
Common Screen
The right side of the GUI shows the status of the ISL94203. At the top are voltage, current, and temperature
readings. The bottom shows the status bits.
At the bottom of the screen are several controls for temperature settings and memory access.
4.1.1 CELL Voltage Scans
The voltage readouts (Figure 5) show the values for each cell, plus CELLMAX and CELLMIN values. The
CELLMAX and CELLMIN values are returned from the ISL94203 registers. To properly implement this operation,
the GUI stops the internal voltage scan of the ISL94203 (using the µCSCAN bit). It reads the cell voltages and
CELLMAX and CELLMIN values and restarts the automatic scan of the device. The values are read
asynchronously, so without stopping the scan there is not sufficient time to read all the values prior to the next
internal scan. For this reason, the CELLMIN and CELLMAX values are often reported from a different scan than
the rest of the cell voltages. Also, during the scan, the cell balance operation is stopped. The operation stops so
that the cell balance currents do not cause false readings of the cell voltages, due to external voltage drops.
Figure 5. Voltage Readouts
To the right of the cell voltages, there is a graphic indication of the capacity of the cell. This is based on the voltage
of the cell. In this graphic depiction, the scale shows no bar when the voltage is less than or equal to the
undervoltage threshold. It shows 100%, or maximum, when the cell voltage is equal to or greater than the
overvoltage threshold. See the overvoltage and undervoltage thresholds in the Pack settings tab on the left of the
screen.
The GUI highlights the specific cells that equal the CELLMAX and CELLMIN voltages. This helps to identify which
cells are high or low on quick inspection.
When any cell voltage is lower than the undervoltage level, or higher than the overvoltage level, the background
color of that voltage readout changes to red. When the voltage rises above the UV recovery voltage or drops
below the OV recovery voltage the background color returns to white. These color changes are GUI
representations of the cell voltage conditions, the actual indication from the device is shown by the UV and OV
status indicators (bottom right of the screen). These indicators come directly from the device status bits.
Below the CellMIN and CellMAX readings are three boxes that show additional voltage values. The top box
contains the sum of the individual cell readings. The middle box shows the voltage reading of the total battery
pack as derived from an internal divide by 16 voltage divider and converted by the ADC. Comparing these two
values allows a gross determination if there is a cell voltage failure.
The bottom box shows the voltage of the 2.5V regulator. The regulator voltage is internally divided by 2, converted
by the ADC, and multiplied by 2 prior to display.
AN1952 Rev.3.00
May.9.19
Page 8 of 43
ISL94203EVKIT1Z
4. Using the GUI
Pressing the Read Voltages (Single) button completes one read of the values in the device, (see Figure 6). This
includes all of the voltages and the status bits. Between presses of this button, the device continues to scan the
voltage, current and temperature values at the rate of 32ms (or 256ms if in IDLE mode, or 512ms if in DOZE
mode).
Figure 6.
Pressing the Auto Scan START button starts a repetitive update of the values. The rate of update is set by the
Rate (sec) dropdown box. As shown, the GUI updates the voltages and status every 1 second. Autoscan is
stopped by pressing the autoscan STOP button. While the autoscan is operating, all other memory accesses are
prohibited. To read the pack settings or change a register value, first stop the automatic scan.
To log the data, press Logging START prior to clicking on the Auto Scan START button. The data is stored as a
text document in a file location specified by the user. When all data has been captured, stop the auto scan and
stop logging.
4.1.2 Temperature Readings
To the right of the pack voltage values are the temperature readings, (see Figure 7). In the default state, these
boxes report the voltage on the temperature inputs. There are two boxes for each temperature.
Figure 7. Temperature Readings
The internal temperature reading (at the top) has two boxes. The left box shows the voltage reading from the
internal temperature sensor. This voltage is dependent on the setting of the temperature gain bit (TGAIN). The
temperature gain can be changed using the GUI by clicking the TGAIN button in the temperature box in the
bottom left of the screen (below the tabs). The box on the right shows the conversion of the internal temperature
to °C. This conversion uses Equations 1 and 2:
(EQ. 1)
TGAIN = 0
intTemp mV -
------------------------------------– 273.15 = ICTemp C
1.8527
(EQ. 2)
TGAIN = 1
intTemp mV -
------------------------------------– 273.15 = ICTemp C
0.92635
For the external temperatures, the left box shows the digital reading from the ADC. The right box shows the
applied input voltage. The value on the left is dependent on the setting of the TGAIN bit. If TGAIN = 0, then the
temperature input voltage is multiplied by 2 prior to being read by the ADC. If TGAIN = 1, the temperature input
voltage is multiplied by 1. The left box of the external temperature readings simply translates the voltage readout
by the ADC. The right box calculates the input voltage, based on the setting of the TGAIN bit.
The temperature readings can also be displayed in °C, (see Figure 8). The conversion to °C depends on several
items. First is the gain setting, so the actual input voltage is known. Second is the external resistor divider
components. Third is the conversion of the thermistor value to °C.
AN1952 Rev.3.00
May.9.19
Page 9 of 43
ISL94203EVKIT1Z
4. Using the GUI
Figure 8. Temperature Readings Displayed in °C
The gain setting is important only for determining the voltage applied at the input xTn pin.
Next, the conversion depends on the external resistor divider, and assumes that the external circuit is
implemented as shown in the Thermistor tab drawing, Figure 9 on page 10.
There is a 10k resistor parallel to the thermistor. There are two reasons for this. First, it makes the conversion
curve more linear. Second, the thermistor voltage range better matches the default 2x gain on the temperature
input amplifier. The thermistors are from Murata (XH103F). If an external thermistor replaces the thermistors on
the board, the conversion can be changed by changing the values in the Thermistor tab of the GUI. The values in
the table are the voltages applied to the xTn input pins. The voltage depends on the resistance of the Thermistor
at each temperature and the voltage on the TEMPCO pin. The TEMPCO voltage is 2.5V.
Based on calculations, the voltage/temperature curve for this circuit is shown in Figure 10 on page 11. The GUI
uses the Thermistor table for this conversion and performs a linear interpolation between points.
For calculations of the external temperature, the Thermistor tab contains a value for the external divider resistor.
This can be changed by the user, but not saved.
Figure 9. ISL94203 GUI Thermistor Tab
AN1952 Rev.3.00
May.9.19
Page 10 of 43
ISL94203EVKIT1Z
4. Using the GUI
0.800
0.700
Input Voltage (V)
0.600
0.500
0.400
0.300
0.200
0.100
0.000
-50
0
50
Temperature (°C)
100
150
Figure 10. Voltage to Temperature Conversion
4.1.3 Current Readings
The current readout consists of four boxes, (see Figure 11). The top box shows the voltage across the sense
resistor, as reported by the device and converted to volts. The next box shows the current reading in milliamps.
This value depends on the value of the current resistor. This can be entered into the third current box. The default
value is 1Ω, because that is the value on the ISL94203EVKIT1Z board. If the resistor value changes, this value
can be changed in the GUI (but the default cannot be changed in this revision of the GUI). The bottom box simply
relates the current amplifier gain setting in the device. In automatic scans, there is an automatic gain control. The
gain setting is most useful when forcing a current read by the GUI.
Figure 11. Current Readout
4.1.4 Status Bits
The status indicators on the lower right of the GUI screen (see Figure 12), reflect the status of the bits in the
device. If an indicator is red, it shows a fault or out-of-bounds condition. If an indicator is green, it is showing an
operating condition, such as current direction or power mode.
The status indicators are automatically updated when doing a voltage read operation. However, refreshing only
the status bits is much quicker. So, clicking the Read Status bits updates only the status.
Figure 12. Status Indicators
AN1952 Rev.3.00
May.9.19
Page 11 of 43
ISL94203EVKIT1Z
4. Using the GUI
4.1.5 FET Indicators
Above the voltage readings are the FET indicators, (see Figure 13). These show the status of the PCFET, CFET
and DFET control bits. If the bit is 1 indicating that the FET should be on, the indicator is green. If the bit is 0
indicating that the FET should be off, the indicator is red.
Figure 13. FET Indicators
The FET indicators are more than just readouts. Clicking on the indicators can also set or clear the bits to turn on
or turn off the FETs. However, the GUI does not have control over the FETs when the device is operating in standalone mode. To control the FETs through the GUI requires that the µCFET bit is set first. This bit is set or reset
using the µC Controls FET button in the µC Control Tab.
Above the FET control bits are some controls to change the operation of the device. These controls are PCFET
enable, CFET on during OV, and DFET on during UV.
Setting the PCFET enable to active causes the PCFET to turn on, instead of the CFET, when the voltage is below
the Low V Charge threshold voltage (see the Pack settings).
Setting the CFET on during OV to active means that the charge FET turns on when there is an overvoltage
condition, if the device detects a discharge current. This reduces heat generated in the CFET during discharge.
This is more important when there is a single charge/discharge path configuration.
Similarly, setting the DFET on during UV to active means that the discharge FET turns on when there is an
undervoltage condition, if the device detects a charge current. This reduces heat generated in the DFET during
charge. This is more important when there is a single charge/discharge path configuration.
4.1.6 Other Main Screen Controls
Communication to the device requires an I2C bus. The I2C bus uses a Slave byte to determine the specific device
on the bus that is being addressed. In the GUI this is set by the I2C Addr box (see Figure 14). This is located in
the lower left of the screen. By default, the Slave Byte is 50H (0101 000x). This addresses the device having the
ADDR pin pulled low. Applications where the ADDR pin is tied high are not supported.
Figure 14. I2C Address Box
Temperature measurement options are selected in this box (Figure 15) below the tabs. The pack settings and
temperature outputs can be shown as either volts or °C. Changing the setting initiates a voltage scan and an
update of the Pack Settings. The calculations are made in the GUI as described previously. The device simply
maintains the voltage value associated with the temperature.
Figure 15. Temperature Measurement Options
This box also has the selection for the TGAIN bit. Clicking on the TGAIN box changes the TGAIN bit in the device,
updates all of the RAM settings for temperature limits and initiates an update of the Pack Settings tab. It does not
do a voltage scan. The caption shows the current status of the temperature gain. Figure 15 indicates that the
temperature gain is set to 2x.
AN1952 Rev.3.00
May.9.19
Page 12 of 43
ISL94203EVKIT1Z
4. Using the GUI
Access to the EEPROM requires an access control bit to be set prior to a read or write operation. In all of the
screens where a button initiates multiple read or write operations, the memory access is automatically set to the
correct access code and automatically reverts to RAM access. However, for individual memory read or write, it
may be necessary to change the access code. These buttons allow this access code change. Simply click on the
desired memory area button, prior to the actual read or write operation.
Figure 16. Memory Access
The ISL94203 Internal AD Utility screen enables you to view and record AD readings in real time. By using the I2C
interface, the GUI enables you to select any of the internal Mux channels and view/capture the results in real time.
To bring up the AD form, click on the Internal AD Utility selection on the menu bar of the main form.
ISL94203EVKIT1Z
Figure 17. Menu Bar
When first loaded, the new form appears as shown in Figure 18.
Figure 18.
An important first step is to select an internal Mux Channel that is going to be measured. By making a selection
(clicking on a Mux selection button, see Figure 19), data collection/graphing automatically starts and after a few
seconds Auto Range takes place.
AN1952 Rev.3.00
May.9.19
Page 13 of 43
ISL94203EVKIT1Z
4. Using the GUI
Figure 19.
Essentially, clicking in the frame selection selects the value written to register 0x85. You can consult the ISL94203
datasheet for specifics related to each Mux Input connection. A real-time display of the register contents is
displayed in Figure 21.
Figure 20.
Figure 21.
Therefore, this selection programs the MUX blocks connected to the input of the internal AD.
Figure 22.
AN1952 Rev.3.00
May.9.19
Page 14 of 43
ISL94203EVKIT1Z
4. Using the GUI
4.1.7 Main AD Form Tools
Figure 23.
1. Actual Dual Byte Hex value of AD reading
2. Calculated value based on channel selected
3. Active channel being measured
4. GO Starts and STOP ends data collection. Click Stop to save collected readings to file.
5. Enable Plot, speeds up data collection by disabling real-time graphing
6. Highest reading – lowest reading
7. Display of most recent reading
8. Peak/Maximum value recorded
9. Minimum value recorded
10. Clears items 6, 8, 9
11. Resets graphing scale to max default
12. Recalculate Maximum and Minimum values of graphing area
13. Decreases volts per division (visual only does not affect collected readings)
14. Increase voltages per division (visual only does not affect collected readings)
15. Recenters midrange scale and moves graphing range
16. Actual time in milliseconds to capture and graph a measurement
17. Hex value of Mux control register
18. Internal Mux selection
19. PGA gain selected when making a current measurement
20. Checking appends the latest collection of readings to a file
21. Browse to directory location where captured readings are saved
22. Perform actual write operation
AN1952 Rev.3.00
May.9.19
Page 15 of 43
Page 16 of 43
Figure 24.
4. Using the GUI
To quit the program, click on Quit.
ISL94203EVKIT1Z
AN1952 Rev.3.00
May.9.19
The Internal AD Utility form is a separated form that can be closed or minimized independent of the main screen (see Figure 24).
ISL94203EVKIT1Z
5.
5.1
5. Tab Controls
Tab Controls
ISL94203 Memory Access
5.1.1 RAM
The ISL94203 has two main memory areas, RAM and Configuration Memory. The RAM area contains the
transient values, such as cell voltages, status bits, and microcontroller override conditions. The RAM registers
relate to the part of the GUI already described and the GUI reads and writes these registers as needed. You also
have direct access to the RAM memory through the RAM tab, see Figure 25.
To update the values in the GUI with the values in the ISL94203, press the Read All RAM button. The display
now shows the hex values of the RAM registers. Alternatively, each individual location can be updated by clicking
on the R to the right of the register location.
There are only six registers that can be changed by the user. These are addresses 84H to 89H. These locations
have a W next to the register. To change the register contents, write a new hex value in the desired location and
press the W button (or the Write All RAM button). Until a write occurs, the contents of the ISL94203 RAM is not
changed.
As shown in Figure 25, hovering the mouse pointer over the address of a register returns a description of the
register. Also, the registers are color coded to match the datasheet and to group like registers. For example, in
Figure 25, registers 80H to 84H are cyan color. These are the status registers. Also, registers 8EH through ABH
are blue. These registers hold the voltage readings for the cells, current and temperature.
When pressing the Read All RAM or Write All RAM buttons, the color of the button changes and the caption
changes to Busy. During this time the GUI is performing the specified operation and other operations are
prohibited until the read or write completes and the color and caption return to normal. This sequence occurs on
all controls described in the following.
The main screen shows the real world contents of the ISL94203 registers, converting hex values to volts, current,
or temperature and indicating individual status bits. The GUI performs this update when the Read Voltages
(Single) or automatic scan executes. The update operation begins with a Read All RAM operation. This brings in
values from the ISL94203 (see Figure 26 on page 18). The GUI converts the hex values in RAM to the proper
voltage, current, or temperature value.
The GUI controls for the writable RAM registers are located in the µC Control tab. These tab operations are
discussed in more detail in the following.
AN1952 Rev.3.00
May.9.19
Page 17 of 43
ISL94203EVKIT1Z
5. Tab Controls
Figure 25. ISL94203 GUI RAM Access Tab
ISL94203
Main Screen
ISL94203
GUI RAM Tab
ISL94203
RAM Memory
3
2
1
Note: Read Voltages (Single) or Read Status Bits Operation execution steps are numbered. Write All RAM writes to the ISL94203 RAM
memory, and updates the Main Screen.
Figure 26. ISL94203 GUI RAM Update Operation (Read Operation Numbered)
AN1952 Rev.3.00
May.9.19
Page 18 of 43
ISL94203EVKIT1Z
5. Tab Controls
5.1.2 Configuration Memory
The Configuration Memory consists of two parts, the EEPROM cells and Configuration RAM. On power-up, the
contents of the EEPROM is copied to the Configuration RAM. The device operates out of Configuration RAM.
Reading and writing the EEPROM does not automatically go through the Configuration RAM. Writes made to the
EEPROM locations go into effect when the device power cycles or when the EEPROM contents are read from the
EEPROM and rewritten to the Configuration RAM.
In the normal course of developing an application, a change is made to the Configuration RAM. This changes the
operation of the device. For example, changing the overvoltage setting in the Configuration RAM changes the
voltage at which the device detects a fault condition. However, the value has not yet changed in the EEPROM, so
a power cycle returns the old OV threshold. To make the value permanent requires that the value also be written
to the EEPROM.
The EEPROM tab (see Figure 27) of the GUI shows only one set of registers. This could be the values read from
the Configuration RAM or from the EEPROM. Which values it displays is dependent on the access code. The
access code is set in Register 89H, but the GUI automatically sets this bit when the Read EEPROM or Write
EEPROM buttons are pressed. The Access code is also settable by clicking the Memory Access button as
described previously.
To write to individual bytes of the RAM part of the Configuration Memory, set the RAM Access in the Memory
access box. Each byte in RAM can be written separately.
Writing to individual bytes to the EEPROM part of the Configuration Memory is limited. Each EEPROM write
needs to write all four bytes on a page. For this reason, the GUI has a different (larger) button for writing to
EEPROM. As previously mentioned, to write to a page of EEPROM, it is necessary to set the EEPROM Access
in the Memory access box prior to the write.
As with the RAM tab, hovering over an address box brings up a dialog showing a simple description of the register
contents. Also, the various registers are color coded as shown in the datasheet and are grouped by function.
The EEPROM tab has three other buttons. The first is a Load Factory Default button. This fills the GUI EEPROM
locations with the factory default values (as defined at the time of the GUI release). This lets you recover to a
known good operating point. Again, use of this button fills the GUI registers. To change the operation of the device
or the contents of the EEPROM requires a separate write for each memory location.
The other two buttons are Save User Default to File and Load User Default from File. These commands allow
the user Configuration Memory to be saved and recalled. The values saved are locations 0H through 4BH.
AN1952 Rev.3.00
May.9.19
Page 19 of 43
ISL94203EVKIT1Z
5. Tab Controls
Figure 27. ISL94203 GUI - EEPROM Access Tab
5.1.3 User Memory
The user memory area is different from the Configuration memory. The User memory does not have a RAM
component, so all reads and writes are to the EEPROM only. Also, the device ships with the user memory
cleared. So, an initial read from user memory reads 0.
Using the Load User Factory Default tells the GUI to put the software revision number in the GUI locations for
the user memory. You can keep these values or load other data in the GUI boxes. To write the data to the
ISL94203 User EEPROM requires individual writes (click the EEPROM Memory Access first) or a write all, using
the Write User EE button (this automatically sets the EEPROM Access bit).
The User EE tab also includes a Load Default from File and a Save User Default to File. These buttons load
and save User EE data at addresses 50H to 57H only.
AN1952 Rev.3.00
May.9.19
Page 20 of 43
ISL94203EVKIT1Z
5. Tab Controls
Figure 28. ISL94203 GUI - USER EEPROM TAB
5.1.4 Pack Settings Tab
The Pack Settings tab (see Figure 29) provides access to the contents of the Configuration RAM, but with
real-world values. This provides an easier way to program the operation of the pack and to monitor the present
settings. Values in the Pack Settings tab are saved in the GUI. When a Read Pack Settings button is pressed,
the value is read from the device and loaded into the Configuration RAM tab of the GUI. The GUI then takes the
contents of the Configuration RAM, calculates the real world value and writes it to the pack settings tab.
When a value is changed in the Pack Settings tab, nothing happens until a Write Pack Settings button is
pressed. The GUI takes the value in the Pack Settings tab, converts the value to hex and writes the new value to
the Configuration RAM tab in the GUI. These values are written from the GUI to the RAM part of the device
Configuration memory. If a value is changed in the GUI, but no write button is pressed, the device is not updated
with the new value.
As soon as the Write Pack operation completes, the ISL94203 begins operating with the new parameters.
The Pack Settings tab also includes a Write EEPROM button. This is a convenience, because it does the same
function as the button in the EEPROM Tab. However, in the Pack Settings tab, it is necessary to do a Write Pack
Settings operation prior to doing the Write EEPROM. Otherwise, the EEPROM would not get the latest values
from the Configuration Memory RAM to write to EEPROM. This is because the Write EEPROM writes values from
the GUI Config Mem tab to the device and the values in the GUI Config Mem tab are not updated until execution
of the Write Pack Settings operation.
Figure 30 on page 22 shows a graphical representation of the operation of the Pack Settings tab operation, the
GUI EEPROM tab and the ISL94203 internal registers.
The memory operations of the Pack Settings tab was described above. The next section covers some additional
details about the calculations and use of the values shown in the Pack Settings tab.
AN1952 Rev.3.00
May.9.19
Page 21 of 43
ISL94203EVKIT1Z
5. Tab Controls
Figure 29. ISL94203 GUI - Pack Settings Tab
ISL94203 GUI
ISL94203 GUI
ISL94203 Device
ISL94203 Device
Pack Settings Tab
EEPROM Tab
Configuration RAM
EEPROM Memory
(EEPROM Shadow Memory)
(No User
Shadow
RAM)
Copy
Translate
Copy
Copy
1
2
2
1
Figure 30. ISL94203 GUI Pack Settings Tab Memory Operations
AN1952 Rev.3.00
May.9.19
Page 22 of 43
ISL94203EVKIT1Z
5. Tab Controls
5.1.5 Voltage Limits
The upper left section of the Pack Settings tab contains the voltage thresholds and delay times, (see Figure 31).
The voltages can be set from 0V to 4.8V. A negative number loads 0 and a value greater than 4.8V loads 4.8V.
The timer values for OV Delay, UV Delay, and Open Wire Sample Time can be between 0 and 1023. The timer
value for Sleep Voltage Delay time can be between 0 and 512.
Figure 31. Voltage Thresholds and Delay Times
Normally, the OV Lockout threshold is greater than the Overvoltage threshold and the UV Lockout threshold is lower
than the Undervoltage threshold. The reason for this is based on the definition of the values. Reaching the
overvoltage and undervoltage thresholds causes the respective power FETs to turn off, but the pack continues to
operate normally. However, if the voltage of any cell reaches the UVLO or OVLO thresholds, something is very
wrong with the pack or the charger. Reaching the OVLO threshold causes the device to set a pack shutdown (PSD)
bit. This can be used to blow a fuse to disable the pack. Reaching the UVLO threshold indicates that one or more
cells are much below their lower limit, so the device powers down to remove as much load as possible from the cells.
The End of Charge threshold is usually lower than the overvoltage threshold. When a cell reaches the overvoltage
threshold, the end of charge output (EOC pin) can turn off the charger. If the voltage continues to rise, there is
something wrong with the charger, so the overvoltage indication turns off the charger current from within the pack.
Alternatively, the EOC limit can be used for cell balancing to specify a level where balancing is to begin. In this
case, when any cell reaches the End of Charge threshold, all cells that are higher than CELLMIN + CB MIN Delta
start to balance. Balancing continues until all cells are below the EOC Threshold -117mV.
The Sleep voltage, along with the sleep voltage timer determine if the cells drop below a sleep threshold. If so, the
power FETs turn off and the device enters a sleep mode. The device wakes from a sleep mode by the connection
of a load or a charger to the pack.
The Low V Charge threshold is used when the precharge FET is enabled. The low voltage charge threshold is
the level where the charge FET turns on instead of the precharge FET. When the cell voltages are below the Low
V charge level, the precharge FET is on. When the cell voltages are greater than the Low V charge level, the
charge FET is on.
5.1.6 Current Limits
To the right of the voltage settings are the current limits for discharge overcurrent, charge overcurrent, and
discharge short-circuit events, (see Figure 32 on page 24). The delay time values can be 0 to 1023 microseconds,
milliseconds, seconds or minutes. Care should be taken when setting the range of these timers. The threshold
levels are set by drop down boxes and set the overcurrent level by setting the voltage expected across the sense
resistor.
AN1952 Rev.3.00
May.9.19
Page 23 of 43
ISL94203EVKIT1Z
5. Tab Controls
Figure 32. Current Limits
Also in this selection is the setting for the duration of the charge and load pulse widths. When the power FETs turn
off in response to an overcurrent event, the ISL94203 starts looking for the release of the load or charger. It does
this by periodically sourcing or sinking a current to the load or from the charger. The duration of the pulse width
might need to be changed, depending on the load or charger capacitance, because the detection circuit is
attempting to pull the voltage at the terminals to some intermediate state. If the load or charger is off, but there is
a large capacitance still connected to the terminals, a short pulse width takes longer to detect the removal. The
ISL94203 allows detection pulse widths from 1ms to 16ms.
5.1.7 Timers
Below the voltage settings are some timer controls. The upper box specifies the amount of time the device spends
in normal mode (with no measured current) before entering into IDLE and the time the device spends in IDLE
before entering the DOZE mode. The Sleep Mode Timer specifies how long the device remains in DOZE mode
(with no measured current) before going to sleep. Detection of any current returns the part to the normal operating
mode.
Figure 33. Timer Controls
The WD Timer setting is used with µC override operations. When the µC sets any condition that overrides internal
operation, the WD timer starts. The WDT is reset by any valid reception of an I2C slave byte. If there are no valid
communications before the WDT times out, the ISL94203 turns off all FETs and waits for a valid command.
5.1.8 Number of Cells
The # of Cells box specifies the number of cells connected to the pack. The number in the
box can be lower than the number of cells connected to the pack. This value is a direct
representation of the number of cells, it is not the value stored in memory. The GUI translates the number of cells
value to the proper code for the device, as specified in Table 1.
When the board first powers up, the # of Cells is set to 3. This causes some of the cells to show 0V in a Voltage
Scan. This is because the cells are skipped in the scan. If there are more cells connected, change the setting,
write the values to the pack, and write the values to EEPROM.
The reason for the default value of 3 in the # of Cells box is that if the number in the box is greater than the
number of cells connected to the pack, when the ISL94203 first powers up it reads a cell input as 0V. The
ISL94203 thinks that this is a cell failure, so does not complete its power up sequence. This is part of the
protection mechanisms of the part. If the value written to the EEPROM is higher than the number of cells
connected and the device powers down, it does not power up properly. It is necessary to connect the programmed
number of cells (or more) so the device powers up. Then the EEPROM value can be reset.
AN1952 Rev.3.00
May.9.19
Page 24 of 43
ISL94203EVKIT1Z
5. Tab Controls
For the proper connections of fewer than 8 cells, see Table 1. When using the evaluation board with fewer than 8
cells, connect the unused cell inputs at the board connection. It is not necessary to remove any components on
the board (see Figure 52 on page 38).
Table 1.
ISL94203 Cell Configuration
Cells Value
Number of Cells
10000011
3 Cells connected, C1, C2, C8
11000011
4 Cells connected, C1, C2, C7, C8
11000111
5 Cells connected,
C1, C2, C3, C7, C8
11100111
6 Cells connected, C1, C2, C3, C6, C7, C8
11101111
7 Cells connected, C1, C2, C3, C4, C6, C7, C8
11111111
8 Cells connected, All cells connected
Note: Only these combinations are acceptable. Any other combination prevents any FET from turning on.
5.1.9 Cell Balance Limits
The next box to the right (Figure 34) contains the settings for cell balancing. The voltage limits that can be set in
the GUI are fixed at 0 and 4.8V. There are no limits to the temperature settings. The temperature values are
limited by the GUI from 0 to 1.8V (voltage setting) or -40°C to +125°C (temperature setting).
Figure 34. Number of Cells Box
The CB lower limit and CB upper limit define the boundaries of the cell voltage operation (except in EOC
balancing). If ALL cell voltages exceed the limits, then balancing stops. Balancing starts again when ALL cell
voltages drop back within the specified limits plus a hysteresis. For example, if the CB upper limit is set to 4.0V,
balancing stops when all cell voltages exceed 4.0V. Balancing resumes when all cell voltages drop below 3.883V.
CB Max Delta specifies the maximum difference between the CELLMAX and CELLMIN values. When this
happens, it implies that there is something wrong with the cells or connections. When cell voltages exceed the CB
Max Delta limits, the CELLF flag is set. This can cause the PSD pin to active (optional) which can shut down the
pack. The CELLF indication also starts the open wire detection operation.
The CB over- and under-temperature settings specify the temperature range over which the cell balance
operates. If the external temperature sensors show that the temperature is out of bounds, cell balance stops.
The CBON and CBOFF times specify how long the cell balance is on and off. These timers are mainly used for
thermal control to manage the heat dissipated by the cell balance resistors.
5.1.10 Temperature Limits
On the lower right of the Pack Settings tab are the pack temperature limit settings. There are temperature limits
for charge and discharge as well as temperature recovery levels for each. These limits refer to the ADC converted
value of the temperature sensor inputs, so they are affected by the TGAIN bit. The GUI limits values in these
locations from 0 to 1.8V (voltage setting) or -40°C to +125°C (temperature setting).
AN1952 Rev.3.00
May.9.19
Page 25 of 43
ISL94203EVKIT1Z
5. Tab Controls
Figure 35. Pack Temperature Limit Settings
When the TGAIN bit changes from 0 to 1 or 1 to 0, the GUI rewrites the values of the temperature limits in the
EEPROM tab (based on the temperature input amplifier gain) and sends these new values to the ISL94203. The
GUI also updates the Pack Settings Information. The Pack Settings tab temperature limits do not change if they
are shown in °C, but the value in the device does change. This is because the calculations for the temperature
settings in °C includes the setting of the TGAIN bit.
5.1.11 Pack Options
In the lower left of the Pack Setting tab are various option controls (see Figure 36).
Figure 36. Option Controls
Setting the xT2 Monitors FET Temp to 1 tells the device to treat the xT2 input as a FET temperature, not a cell
temperature. With this bit set, an over-temperature on the xT2 input does not stop cell balancing, it only turns off
the power FET.
The Enable CELLF PSD action, when set to 1, causes the PSD bit to be set when the device detects a condition
that sets the CELLF bit.
The Enable Open Wire PSD bit, when set to 1, causes the PSD bit to be set when the device detects an open
wire condition.
The Enable UVLO Power Down, when set to 1, causes the device to power down when it detects an
undervoltage lockout condition.
The Disable Open Wire Scan bit, when set to 1, turns off the open wire scan operation.
5.1.12 Cell Balance Enable
As part of the Cell balance settings are the Cell Balance controls for charge, discharge or
end-of-charge balancing.
If CB during charge is checked, the device activates cell balancing if charge current is detected and all other
conditions are within limits. If there is no current or there is discharge current, the device does not balance.
If CB during discharge is checked, then the device activates cell balancing if discharge current is detected and
all other conditions are within limits. If there is no current or there is a charge current, the device does not balance.
If the CB during EOC is checked, the device ignores the current detection and balances only based on the endof-charge condition (as long as all other conditions are with limits). With this option selected, cell balancing is
enabled when any cell reaches the end-of-charge threshold. Balancing continues as long as any cell is greater
than the EOC threshold minus 117mV.
AN1952 Rev.3.00
May.9.19
Page 26 of 43
ISL94203EVKIT1Z
5. Tab Controls
While cell balancing is enabled, in any mode, balancing is turned on for any cell whose voltage is more than
CELLMIN + CB Min Delta volts.
5.2
µC Control Tab
The µC Control tab provides a mechanism for the GUI to override the internal operation of the device. An external
microcontroller would use similar techniques to provide different functionality to the pack than is offered by the
built-in automatic operations. The options available on the µC Control tab are shown in Figure 37 on page 28.
5.2.1 Power Control
The mode of operation of the device is controlled by these check boxes (see Figure 38 on page 28). Clicking any
box puts the device into that mode of operation. Clicking on None removes any forcing condition. The µC Control
features does not allow the device to be placed back into normal operation. For example, when the device enters
IDLE mode, it can be placed in DOZE mode, returned to IDLE mode, put to sleep, or set to power down, but it can
only return to a normal scan operation if it detects current flow in the pack. The GUI also offers a demo mode that
forces a current indication, which can be used to return to normal mode.
It is not necessary to override any internal operation to change the operating mode.
5.2.2 Individual Voltage Monitoring
The GUI or an external µC can force a read of any voltage available from the internal MUX. This includes cell
voltages, pack current and voltage, and temperatures. It is not necessary to override any internal function to use
this measurement.
To use this feature, select the voltage to be measured and click the W button. The R button reads the status of the
AO3:AO0 bits, but a write operation sets the bits for the desired voltage and sets the ADCSTRT bit, which is
needed to start the internal conversion operation. The resulting voltage shows in the box at the right, (see
Figure 39 on page 28). This is a 14-bit hex value. This value needs to be converted to voltage, current, or
temperature.
When measuring the current, the gain of the amplifier can be manually set prior to the ADC read by using the drop
down box and W button on the top line.
The GUI allows the repetitive capture of any single voltage or all voltages. For a single voltage capture, the
desired voltage is selected by the Monitor Voltage box (see Figure 40 on page 28). The number of samples is
specified and the Sample Voltages button is pressed. This brings up a dialog box asking for the file name for the
data to be stored. The GUI captures the specified number of samples and stores the data to the file. This is a tab
delimited file that can be imported into Excel.
Between the Sample All Voltages and Sample Single Voltage buttons is a progress indicator showing the
ongoing data capture.
AN1952 Rev.3.00
May.9.19
Page 27 of 43
ISL94203EVKIT1Z
5. Tab Controls
Figure 37. ISL94203 GUI - µC Control Tab
Figure 38.
Figure 39.
Figure 40.
5.2.3 Microcontroller Does...
The next set of controls (Figure 41) allows the GUI (or microcontroller) to take over several functions of the
device. The most general is the µC Does Scan box. When checked, the device stops scanning the cells, which
effectively stops automatic operation. When this box is checked, cell voltages are scanned by the external µC, OV
and UV voltages must be manually compared with limits and cell balance must be controlled externally. The only
function maintained internally during a µCSCAN operation is the overcurrent/short circuit monitoring. These
continue to be automatically monitored.
Figure 41.
AN1952 Rev.3.00
May.9.19
Page 28 of 43
ISL94203EVKIT1Z
5. Tab Controls
The µC Controls FETs operation gives the GUI or external µC control over the FETs. With this box unchecked,
the ISL94203 has exclusive control over the FETs. It is not possible to change the FETs from the outside. When
the box is checked, the FETs are only controlled by the GUI or an external µC.
The µC Does Charge Mon bit overrides the internal charger monitor function. When overridden, the GUI or an
external µC can turn on the charger monitor current and detection hardware by setting the Charge Mon Enable.
The GUI or external µC needs to monitor the CH_PRSNT bit to detect if there is a charger present. If the charger
is removed following an overcurrent condition, the GUI/µC needs to reset the charge error bit by clicking on CLR
Charge Error.
The µC Does Load Mon bit overrides the internal load monitor function. When overridden, the GUI or an external
µC can turn on the load monitor current and detection hardware by setting the Load Mon Enable. The GUI or
external µC needs to monitor the LD_PRSNT bit to detect if there is a load present. If the load is removed
following an overcurrent condition, the GUI/µC needs to reset the load error bit by clicking on CLR Load Error.
All of these operations start the Watchdog timer. If communications with the device stop for more than the
Watchdog time-out period, the device resets the override bits and waits for a valid communication. When a valid
communication is received, the device resumes normal, default operation.
The Pack Shut Down control is a direct control of the PSD pin. The Open Wire Start is a manual open wire start
operation. This open wire scan does not need to first wait for a CELLF condition.
5.2.4 µC Cell Balance
The GUI/µC can manually control the cell balance operation, overriding the internal automatic balancing. Set the
µC Does Cell Bal bit and the Cell Balance On bit. Check any, or all, of the individual cell balance bits to activate
the cell balance outputs (see Figure 42)
.
Figure 42. Cell Balance
However, before the balancing outputs turn on, all other conditions for balancing must be met. There can be no
error conditions and if balancing is selected during charge, there must be a charge current before the cell balance
outputs turn on. During a µC controlled cell balance operation the CBON and CBOFF timers are not used.
When the µC Does Cell Bal is set, the Watchdog timer starts and communications must happen within the
watchdog time out period. If there is an interruption in the communications, the µCCBAL bit is reset and the
device waits for a valid communication. When a valid communication is received, the device resumes normal,
default operation.
The indicators to the left of the control boxes indicates which cells are to be balanced. If proper balancing
conditions are not met, the indicators are off. If the cells should be balancing, the indicators are on. If the LEDs on
the board are not on at the same time as the indicators in the GUI, there could be a hardware problem.
When clicking the Read Control Registers button, the status of all of the override bits are
updated.
AN1952 Rev.3.00
May.9.19
Page 29 of 43
ISL94203EVKIT1Z
5.3
5. Tab Controls
DEMO Tab
The last tab in the GUI offers some demonstration controls, see Figure 43. This allows you to test some items
without connecting a real charger or load to the system. This is useful in simulating current flow and overcurrent
errors.
The controls available in this tab are test modes only. They set the various bits in the device, but do not actually
create the condition. However, by setting the bits in the device, the device responds as if the condition occurred.
For example, forcing the charge current direction bit forces the device back into normal operating mode and
enables balancing (if balancing is enabled during charge).
Figure 43. ISL94203 GUI - DEMO Tab
5.3.1 Current Direction Demo
The Force Charge Indicator or Force Discharge Indicator controls force the device to indicate a charge or
discharge condition (see Figure 44). This is not a real condition, for example, the current readout shows no
current flow. However, the device responds as if there is a current.
Figure 44.
While in either of these demo modes, the device does not respond to real overcurrent or short circuit conditions.
To clear the conditions, click on the Un-force Current Direction Indicator button.
AN1952 Rev.3.00
May.9.19
Page 30 of 43
ISL94203EVKIT1Z
5. Tab Controls
5.3.2 Overcurrent Demo
To simulate any of the overcurrent or short circuit conditions, use the Over Current Fault demo options (see
Figure 45). The Force Charge Over Current Condition sets the COC bit and the device responds as if that
condition exists. To better view the operation, the GUI sets the µCLMON and µCCMON bits so the recovery
conditions are controlled manually. Without the µCCMON and µCLMON bits set, the device does the following:
• The test bit indicates to the device that there is an overcurrent condition.
• The device sees that there is no current, so starts the LDMON or CHMON operation.
• The device sees that there is no load and no charger, so it clears the fault condition.
• The device immediately sees the test mode fault condition, so it again responds as if there is fault.
• The device continues to oscillate between these modes, because the demo condition is not real.
Figure 45. Overcurrent Fault Demo Options
To get a better understanding of the operation, connect a potentiometer to the load output. Make sure that the
minimum resistance on the potentiometer is about 1kΩ. This is not so low that it is damaged when the FETs are
on, but is low enough to detect a load. Now, force a discharge overcurrent condition. (Look at the SD LED on the
PCB, it should be on continuously). Use the µC Control tab to clear the µC Load Monitor bit. Now, the device
detects the overcurrent (from the test bit). It sees that there is no current, so it starts the load monitor. Because of
the potentiometer, it sees that there is a load, so the fault condition remains in effect and the SD LED remains on.
By gradually increasing the resistance on the potentiometer, the device reaches the point where the device
detects that the load is removed. At this point, the SD LED resumes the oscillations as it detects the load clearing
and sees the demo fault.
AN1952 Rev.3.00
May.9.19
Page 31 of 43
ISL94203EVKIT1Z Hardware Design
1RWH
0D[LPXPFRQWLQXRXVFKDUJHFXUUHQW $
0D[LPXPFRQWLQXRXVGLVFKDUJHFXUUHQW $
2YHUFKDUJHFXUUHQW $V
2YHUGLVFKDUJHFXUUHQW $PV
6KRUWFLUFXLWFXUUHQW $XV
3
200/1W
J10
1
DFET
C22
C23
4.7nF
4.7nF
1nF
YLOW
R25
R33
1
LED
1k
R16
Q5
Page 32 of 43
NDS7002A
R8
CB1
&%
TP10 TP11 TP1
GND
GND GND GND
Note:
Th2b is physically
located under
the Discharge
FET.
xTH2a
Th2b
Therm2a
XH103F
2
4
R61
22k
6
6
IO1
5
SI1970
1
TVS BIDIR
D28
2.2uF
D26
RED
RED
GRN
Q13
Q15
Q16
R79
2.49k
C31
C32
2.2nF
2.2nF
R81
2.49k
MBT3904DW1
2.49k
MBT3904DW1
R78
R82
2.49k
MBT3904DW1
RED
MBT3904DW1
10k
1k
Q12
R17
Logo
,QWHUVLO
INTERSIL LOGO
ADD to reduce switching spikes
Title
10k
ISL94203EVAL1Z
330k
xTH1
Therm1
R62
22k
ROHS
3E
Size
B
Number
Revsion
ISL94203EVAL1Z
D
Th1
XH103F
52+6
Date:
Nov 12, 2013
Sheet
R86
10k
ROHS
File:
ISL94203EVAL1Z
Drawn by: CEM
Figure 46. ISL94203EVKIT1Z Hardware Design
STAT/CNTRL
J13
RGO
R53
49.9k
R74
1k
PSD
49.9k
R52
R73
D25
1k
SD
49.9k
R50
R71
D23
R49
D22
1k
EOC
49.9k
R70
ADD to prevent
FETSOFF
TMPO
TMPO
120k
xT2
xT2
1
R75
1
1
R39 100
VBATT
powering IC from I2C
1
SCL
SCL
xT1
xT1
2
3
RGO
FETSOFF
1
3
2
GND
IO2
IO2
U2
USBLC6-2SC6
5
FETSOFF
4
1
IO1
VBUS
4
3
100
I2C
26
25
1uF
J7
C28
D30
1
XH103F
10k
R85
3.3V
27
*1'
TP9
1M
1
R38
U3
1uF
CB1
R65
2
28
C3
Th2a
1M
3
29
1
*1'
4.7k
4
30
C4
VREF
VREF
R64
5
31
J6
47nF
47nF
47nF
&%
&%
C21
CB2
VC0
R69
6
VC1
VC0
7
32
0
24
23
22
21
20
19
18
VC1
8
33
PAD
ADDR
NC
TEMPO
xT2
SCL
xT1
SDAI
CB3
VREF
SDAO
VC3
R68
CHMON
C3
C2
LDMON
C1
DFET
VDD
CB4
1
39
40
38
37
42
41
45
43
46
47
48
44
PCFET
CFET
CS2
CS1
GND
&%
10k
R7
330k
100/1W
VC4
xT2 select
D8
CB2
47nF
1k
47nF
CB3
C20
1
R15
Q4
GND
VC2
1
47nF
R48
47nF
CB3
C19
R32
NDS7002A
CB5
J5
34
ISL94203
10k
100/1W
NC
VC2
1
R47
&%
LED
1k
VC5
1k
C18
R24
12
INT
VSS
1
C17
YLOW
11
&%
VC3
PSD
CB6
1k
330k
Battery Connect
VC3
10
VC6
VC0
&%
47nF
R14
R6
9
VC4
1
8
FETSOFF
CB1
1
&%
VC4
CB7
VC1
7
1k
SD
35
1k
1
100/1W
6
VC7
17
&%
330k
NDS7002A
&%
VC5
CB4
10k
R31
1k
5
EOC
VC2
CB4
4
3.3M
36
RGO
CB8
16
R13
Q3
D7
VC5
R46
R5
4
LED
1
C15
1k
R23
&%
R43
2
3
1k
1
100/1W
Q2
YLOW
VC6
R45
R30
LED
&%
VC6
VC8
CB2
1
R44
R4
330k
VBATT
1
15
&%
YLOW
R22
VC7
14
R12
CB5
SDA
SDA
R51
U1
VC7
CB5
1
100/1W
C26
1uF
1uF
1k
CB6
10k
7
1
1
R41
C14
R21
C25
VC8
1k
R29
8
D6
VC8
R42
Q1
5
1
1k
1
9
CB6
1
100/1W
YLOW
D4
R28
D32
1
C27
R34
C16
1k
D33
RGO
1uF
1
C2
SMAJ40CA
PCFET
CHMON
CHMON
1
1
LDMON
43V
499
R76
1
R67
LDMON
1
0
R66
R37
100 DFET
D34
18V
43V
1M
DSCG+
TVS BIDIR
D20
SMAJ40CA
1
CFET
GND
47nF
D3
LED
Notes:
- Add a 3.3M resistor (or higher) from
LDMON to GND and CHG+ to DSCG+
to allow sleep mode in 2Path
configuration.
- Add a 2.2nF cap from SD, EOC to GND.
(Prevent spike when the pin goes high.)
- Add 1 schottky diode to VDD to get better
accuracy in single power path conection.
- Zener diodes on cell balance circuits
removed. (They were not needed.)
- Add FETs to I2C inputs to prevent
powering ISL94203 through the uC.
- Remove cell to cell caps and increase cell
to gnd caps.
- Replace power FETs to increase max
voltage.
- Added resistors in current sense circuit for
test purposes.
- Change resistor values for R83, R84 to
reduce current.
100
C13
C0
R77
100
R36
100
PCFET
1
R72
1
1
2
CFET
J11
1 of
1
6. ISL94203EVKIT1Z Hardware Design
C1
R35
100
3
MMBD7000
4700pF/50V
YLOW
10k
R11
R20
2
3
2
13
&%
NDS7002A
C2
1
R40
330k
3
6
PMEG6002
Path2
ADD for better sleep in 2 path connection
R57
100
Q8
NDS0605
D5
C3
CB7
R3
4
NDS7002A
C4
Path1
CB7
1
100/1W
J3
C5
Split Path
3.3M
3
4.7k
R27
1k
C6
when Q9 is off
Improves accuracy
R87
Q10
IRF1010 60V/75A
2
S2
1k
LED
C7
J4
ADD for lower drop in VDD
499
R56
1M
ADDR
D2
LED
Test points
C8
1
Single Path
D19
18V
VB
10k
R10
R19
YLOW
VB
&%
7
CHRG+
Split Path
RGO
R2
330k
NDS0605
5
CB8
Added
resistors to
test effect
on current
sense
C1
C0
1
100/1W
6
CB8
1
C1
10k
R26
Q7
8
J9
D37
1
C2
1k
D1
LED
V10P10
2
D29
&%
R9
R18
C3
1
D21
R59
R1
330k
NDS0605
C4
1M
.002/1W
YLOW
549k
Single Path
SMAJ40CA
Q6
C5
WakeUp
R84
1
1
1
CS2
CON1
C6
S1
3.3M
R83
D36
CS1
D27
3
R58
9%$77
9
VBATT
1k
IRF1010 60V/75A
.002/1W
J2
R63
PMEG6002
43V
*1'
J1
2
Q9
CS2
CS1
TVS BIDIR
C7
4.7uF/50V
D18 R55
18V
C8
C24
68m
BSS170 60V/500mA
R54
D31
1
R60
Q11
ISL94203EVKIT1Z
AN1952 Rev.3.00
May.9.19
6.
ISL94203EVKIT1Z
6.1
6. ISL94203EVKIT1Z Hardware Design
Bill of Materials
Qty
Reference
Designator
9
C13-C21
3
Description
Manufacturer
Manufacturer Part
CAP, SMD, 0603, 47nF, 100V, 10%, X7R, ROHS
Venkel
C0603X7R101-473KNE
C2, C25, C26
CAP, SMD, 0603, 1µF, 50V, 10%, X5R, ROHS
TDK
C1608X5R1H105K
3
C1, C22, C23
CAP, SMD, 0603, 4700pF, 100V, 10%, X7R, ROHS
Venkel
C0603X7R101-472KNE
1
C27
CAP, SMD, 0603, 1000pF, 16V, 10%, X7R, ROHS
Venkel
C0603X7R160102KNE
1
C28
CAP, SMD, 0603, 2.2µF, 10V, 10%, X7R, ROHS
Murata
GRM188R71A225KE15D
2
C3, C4
CAP, SMD, 0603, 1.0µF, 10V, 10%, X7R, ROHS
AVX
0603ZC105KAT2A
2
C31, C32
CAP, SMD, 0603, 2.2nF, 100V, 10%, X7R, ROHS
Venkel
C0603X7R101-222KNE
3
D18-D20
DIODE-ZENER, SMD, 2P, SOD-123, 18V, 500mW, ROHS
Diodes Inc.
MMSZ5248B-7-F-T
8
D1-D8
LED-SMART, SMD, 0603, YELLOW, 1.8V, 2mA, 587nm, 7.9mcd,
ROHS
Osram
LY L29K-J1K2-26-Z
1
D21
DIODE-RECTIFIER, SMD, SMPC, 100V, 10A, ROHS
Vishay
V10P10-M3/86A
3
1
3
D22-D23, D25 LED-SMART, SMD, 0603, 2P, RED, 1.8V, 2mA, 630nm, 4.5mcd, ROHS Osram
D26
LED-SMART, SMD, 0603, GREEN, 1.7V, 2mA, 570nm, 3.9mcd, ROHS Osram
D27, D28, D34 DIODE-TVS, BIDIRECTIONAL, SMD, 2P, SMA, 40V, 400W, ROHS
LSL29K-G1J2-1-0-2-R18-Z
LGL29K-G2J1-24-Z
Diodes, Inc.
SMAJ40CA-13-F
1
D29
DIODE-DUAL, SWT, SMD, SOT23, 100V, 2A, 350mW, ROHS
Diodes Inc.
MMBD7000HS-7-F
1
D30
DIODE-ZENER, SMD, 2P, SOD-123, 3.3V, 500mW, ROHS
Diodes, Inc.
BZT52C3V3-7-F
Diodes, Inc.
BZT52C43-7-F
TRANSIST-MOS, N-CHANNEL, SMD, DPAK, 40V, 9A, ROHS
Fairchild
FDD8451
TRANSISTOR-DUAL NPN, SMD, 6P, SOT363, 40V, 200mA, ROHS
Diodes, Inc.
MMDT3904-7-F
3
D31, D33, D32 DIODE-ZENER, SMD, SOD-123, 43V, 410mW, ROHS
1
D35
DIODE SCHOTTKY, SOD323
2
D36, D37
DIODE, SCHOTTKY, SOD523
1
Q11
4
Q12, Q13,
Q15, Q16
5
Q1-Q5
TRANSISTOR-MOS, N-CHANNEL, SMD, SOT23, 60V, 280mA,
ROHS
Fairchild
NDS7002A
3
Q6-Q8
TRANSISTOR, P-CHANNEL, SMD, SOT23, -60V, -180mA, ROHS
Fairchild
NDS0605
2
Q9, Q10
TRANSISTOR-MOS, N-CHANNEL, SMD, D2PAK, 40V, 75A, ROHS
NXP
Semiconductor
PHB101NQ04T
Venkel
CR0402-16W-102JT
RES, SMD, 0603, 330k, 1/10W, 1%, TF, ROHS
Yageo
RC0603FR-07330KL
RES, SMD, 2512, 100Ω, 1W, 1%, TF, ROHS
Vishay/dale
CRCW2512100RFKEG
Panasonic
ERJ-3EKF1001V
RES, SMD, 0603, 100Ω, 1/10W, 1%, TF, ROHS
Venkel
CR0603-10W-1000FT
RES, SMD, 2512, 200, 1W, 5%, TF, ROHS
Venkel
CR2512-1W-201JT
Panasonic
ERJ-3EKF1004V
12
R18-R25, R49, RES, SMD, 0402, 1k, 1/16W, 1%, TF, ROHS
R50, R52, R53
8
R1-R8
8
R26 - R33
10
R40-R48, R63 RES, SMD, 0603, 1k, 1/10W, 1%, TF, ROHS
7
R34-R39
1
R54
5
R55-R57, R64, RES, SMD, 0603, 1M, 1/10W, 1%, TF, ROHS
R65
2
R58, R59
RES, SMD, 2512, 002Ω, 1W, 1%, TF, ROHS
Panasonic
ERJ-M1WTF2M0U
2
R61, R62
RES, SMD, 0402, 22k, 1/16W, 1%, TF, ROHS
Venkel
CR0402-16W-223JT
2
R66, R67
RES, SMD, 0603, 499Ω, 1/10W, 1%, TF, ROHS
Venkel
CR0603-10W-4990FT
2
R68, R69
RES, SMD, 0402, 4.7k, 1/16W,1%,TF,ROHS
Venkel
CR0402-16W-4701FT
5
R70-R74
RES, SMD, 0402, 49.9k, 1/16W, 1%, TF, ROHS
Panasonic
ERJ-2RKF4992
1
R75
RES, SMD, 0603, 120k, 1/10W, 1%, TF, ROHS
Vishay/dale
CRCW0603120KFKEA
AN1952 Rev.3.00
May.9.19
Page 33 of 43
ISL94203EVKIT1Z
6. ISL94203EVKIT1Z Hardware Design
Qty
Reference
Designator
1
R76
RES, SMD, 0603, 0Ω, 1/10W, TF, ROHS
Venkel
CR0603-10W-000T
1
R77
RES, SMD, 0402, 0Ω, 1/16W, 5%, TF, ROHS
Venkel
CR0402-16W-00T
4
R78, R79,
R81, R82
RES, SMD, 0402, 2.49k, 1/16W, 1%, TF, ROHS
Panasonic
ERJ-2RKF2491V
2
R83, R87
RES, SMD, 0603, 3.3M, 1/10W, 1%, TF, ROHS
Panasonic
ERJ-3EKF3304V
1
R84
RES, SMD, 0603, 550k, 1/10W, 1%, TF, ROHS
Venkel
CR0603-10W-5503FT
11
R9-R17, R85,
R86
RES, SMD, 0402, 10k, 1/16W, 1%, TF, ROHS
Panasonic
ERJ-2RKF1002X
2
S1, S2
SWITCH-TACTILE, PUSH, TH, 8X8mm, SPST, 12V, 50mA, ROHS
Omron
B3WN-6002
3
Th1, TH2a,
TH2b
THERMISTOR, SMD, 0603, 10k, 1/10W, 5%,
B VALUE = 3375-3345K, ROHS
Panasonic
ERT-J1VG103JA
1
U1
IC-MULTI-CELL, LI-ION MONITOR, 48P, QFN, 6X6, ROHS
Renesas
ISL94203IRTZ
1
U2
IC-TVS, ESD PROTECTOR, SMD, 6P, SOT-23-6L, 3pF, 6V, ROHS
ST
USBLC6-2SC6
Microelectronics
1
Description
Manufacturer
Manufacturer Part
PWB-PCB, ISL94203EVKIT1Z, REVD, ROHS
Connectors/Headers
1
J13
CONN-HEADER, 4PIN, 2.54mm, RIGHT-ANGLE, ROHS
Molex
22-05-2041
1
J3
CONN-HEADER, 1X9, FLAT BRK-AWAY, 2.54mm, R/A, ROHS
Molex
22-28-8091
1
TP11
CONN-HEADER, 1x1, BREAKAWAY 1X36, 2.54mm, ROHS
Berg/FCI
68000-236HLF
4
1Path, 2Path,
xTH1, xTH2a
CONN-HEADER, 1x2, BRKAWY 1X36, 2.54mm, ROHS
Berg/FCI
68000-236HLF
3
ADDR, J7, J9
CONN-HEADER, 1x3, BREAKAWY 1X36, 2.54mm, ROHS
Berg/FCI
68000-236HLF
1
J5
CONN-HEADER, 1X8, BRKAWY 1X36, 2.54mm, ROHS
Berg/FCI
68000-236HLF
1
J2
CONN-HDR, 1x9, BRKAWY 1X36, 2.54mm, ST, ROHS
Berg/FCI
68000-236
1
CS1, CS2
CONN-HEADER, 1X2, BRKAWY 1X64, 2.54mm, 0.195x0.118, ROHS Mill-max
800-10-064-10-001000
1
CONN-HEADER, 1X5, BRKAWY 1X64, 2.54mm, 0.195x0.118, ROHS Mill-max
CHMON,
LDMON,
PCFET, CFET,
DFET
800-10-064-10-001000
1
VB, VC0-VC8
Mill-max
800-10-064-10-001000
Mill-max
800-10-064-10-001000
0
CONN-HEADER, 1X3, BRKAWY 1X64, 2.54mm, 0.195x0.118, ROHS Mill-max
SCL, SDA,
TMPO, VREF,
xT1, xT2
800-10-064-10-001000
0
FETSOFF,
PSD, INT, SD,
EOC, RGO
CONN-HEADER, 1X6, BRKAWY 1X64, 2.54mm, 0.195x0.118, ROHS Mill-Max
800-10-064-10-001000
CONN-HDR, 1X10, BRKAWY 1X64, 2.54mm, 0.195x0.118. ROHS
Do Not Populate
0
C24
CAP, SMD, 1206, ROHS
0
R60
RES, SMD, 0805, 68mΩ, ROHS
0
J1, J10, J11
DO NOT POPULATE
0
TP1, TP9,
TP10
DO NOT POPULATE
0
CB1-CB8
CONN-HEADER, 1X1, BRKAWY 1X64,2.54mm, 0.195x0.118, ROHS
AN1952 Rev.3.00
May.9.19
Page 34 of 43
ISL94203EVKIT1Z
6.2
6. ISL94203EVKIT1Z Hardware Design
Layout
Figure 47. Top Layer
Figure 48. Middle Layer 1
Figure 49. Middle Layer 2
Figure 50. Bottom Layer
AN1952 Rev.3.00
May.9.19
Page 35 of 43
ISL94203EVKIT1Z
7.
7. Hardware Overview
Hardware Overview
The hardware design follows recommendations in the datasheet. However, this section provides some additional
guidelines and explanations.
7.1
Jumpers
There are three user selectable options on the ISL94203EVKIT1Z board.
7.1.1 ADDR
This jumper selects the I2C address. Normally this jumper connects to the 0 position. With the jumper set to the 1
position, the GUI I2C address value must be changed to 52.
7.1.2 xT2 Select
There are three external thermistors on the board. There are two near the battery connectors. These can be used
to monitor the battery cells (connect external thermistors to connectors xTh1 or xTH2a and remove the on-board
thermistors Th1 and Th2a). There is a third resistor located under the discharge power FET.
The xT2Select jumper allows the ISL94203 to monitor either the Th2a thermistor near the battery terminals (CELL
position) or the Th2b thermistor under the power FET (FET position). When monitoring the FET thermistor, you
might want to check the xT2 Monitors FET box in the GUI (see “Pack Options” on page 26).
7.1.3 Power FET Configuration
The board allows for both a single charge/discharge path and a separate charge/discharge path. Configuring the
options requires two jumpers. For a single path, connect a shunt on the 1Path side of J4. Also connect a shunt on
the 1Path side of jumper J9. In this configuration both charge and discharge connections of the pack connect to
the DSCG+ pin.
For the separate charge and discharge path, connect a shunt on J4 and J9 on the 2Path side of each. In this
configuration, discharge is on the DSCG+ pin and charge is on the CHRG+ pin.
If the plan is to test the board with significant amounts of current, replace the shunt with some soldered braided
wire to complete the circuit. In this way the board should be able to handle a discharge current of 20A and charge
current of 2.5A.
1 Path
2 Path
Figure 51. Solder Jumpers for Higher Current
7.2
AFE
The Analog Front End (AFE) of the ISL94203 adds external cell balancing components. The cell balance output
from each cell balance pin is a constant current of about 25µA. This generates about 8.25V across the 330k
resistor between the gate and source of the balancing transistor. If a balance FET with lower gate voltage
requirements is desired, reduce the value of the gate resistor.
The evaluation board uses 100Ω cell balance resistors, so it balances about 40mA of current. The board also
includes LEDs on each cell balance circuit to indicate when the cell balance is active.
The cell input filters consist of a 1k resistor, a 4.7nF capacitor to ground, and a 10nF capacitor cell-to-cell. These
can be changed to suit the application, but the following guidelines should be considered.
AN1952 Rev.3.00
May.9.19
Page 36 of 43
ISL94203EVKIT1Z
7. Hardware Overview
• The 1k resistor can be reduced, but this makes the part more susceptible to input currents during hot plug of the
battery cells. A smaller input resistor would also require higher value capacitors to ground to maintain the same
filter. Higher value resistors on the upper cells would be higher cost.
• The 1k resistor can be increased. The limit relates to the accuracy of measurement. In the worst case
conditions, there is a difference of about 2µA of bias current on the inputs. The ISL94203 is factory calibrated
assuming an input 1k resistor. An extra 1k input resistor can generate up to 2mV of error. Larger input resistors
increase this error.
• The capacitors from each input to ground provide a better filter than the capacitors across each input. However,
differences in capacitors on adjacent inputs could result in some voltage errors on the input. Both capacitors to
ground and capacitors across inputs are provided on the board, but the application may not need both.
• Larger input capacitors can affect the open wire detection circuit. If larger capacitors are used and the open wire
circuit does not seem to detect the open condition, increase the Open Wire Sample Time timer value in the
GUI.
7.3
Protection Circuits
The board contains several protection components that should be on any application.
• There should be diodes on VBATT, DSCG+ and CHRG+ to GND to prevent negative voltages on the pins of the
ISL94203. The schematics show the use of 43V zener diodes, so the inputs are also protected against high
voltage transients.
• The board provides transient voltage suppressors on the pack pins to help minimize problems with ESD on the
board.
• There is a protection device (USBLC6) on the I2C inputs to minimize damage due to ESD on the I2C connector.
While this component helps protect against ESD, it is also a problem for the board. Because this component
has internal diodes between the I2C pins and the RGO power pin, connecting the I2C interface to an externally
powered µC before the ISL94203 powers up prevents proper power-up of the ISL94203. If there is a hardwired
connection between the µC and the evaluation board, U2 can be removed from the board and replaced with
jumpers across pins 1 to 6 and 3 to 4. This allows the µC to power up before the ISL94203 powers up.
• Back to back diodes are connected across the current sense inputs to prevent excessive differential voltage
across these pins.
7.4
Push Buttons
The board provides two push buttons for ease of use and evaluation purposes. These are not required in an
application.
• The wake up push button simulates the connection of a pack to a charger. It does this by connecting the
CHRG+ pin to VDD using a 1k series resistor. The device sees this as a charger connection. The ISL94203 can
also be wakened by momentarily connecting a resistor from the DSCG+ pin to GND. Use a 2k resistor to
minimize current when the power FETs turn on. During manufacture of the battery pack, the finished pack can
be connected to a charger, or this wake up switch can be included on an external jig to power up the board prior
to final programming.
• The FETSOFF pin connects directly to the FETSOFF input of the ISL94203. When pressed, the power FETs
and cell balance FETs turn off. Normally in a system, this input would connect to a µC or an external control
source. If FETSOFF connects off board, add a 3V zener diode to GND to prevent glitches on this input from
going too high or negative.
7.5
LED Indicators
There are 4 LED indicators on the board. The LEDs are not required in a real application, they are used here to
provide quick monitoring of the system. The LEDs are RGO (Green), EOC (Red), SD (Red), and PSD (Red).
The LED indicator circuits use current mirrors to drive the LEDs. There are several reasons for this.
AN1952 Rev.3.00
May.9.19
Page 37 of 43
ISL94203EVKIT1Z
7. Hardware Overview
• The ISL94203 RGO regulator output voltage is 2.5V (2.25V to 2.75V). Because of this voltage and range, it is
difficult to directly drive LEDs that have a forward voltage drop of 1.8V to 2.3V while controlling current to
acceptable levels.
• When directly driving the LEDs from the RGO output using a current limiting resistor, small variations in the
supply voltage result in large changes in LED brightness.
• If the LEDs connect direct to the RGO output, the 4 LEDs would pull at least 5mA from the RGO output. While
this is within the capability of the RGO, it could lead to some internal heating of the die. Because this board is for
evaluation, and an actual application would not normally have the LEDs, an indirect approach to powering the
LEDs was adopted.
The current mirrors use a resistor on one side to provide a current gain. The LEDs are each driven with ~1mA of
current from VBATT, but the drain from the RGO output is only ~40µA.
8 Cells
7 Cells
6 Cells
VCELL8
VCELL8
VCELL8
CB8
CB8
CB8
VCELL7
VCELL7
VCELL7
CB7
CB7
CB7
VCELL6
VCELL6
VCELL6
CB6
CB6
CB6
VCELL5
VCELL5
VCELL5
CB5
CB5
CB5
VCELL4
VCELL4
VCELL4
CB4
CB4
CB4
VCELL3
VCELL3
VCELL3
CB3
CB3
CB3
VCELL2
VCELL2
VCELL2
CB2
CB2
CB2
VCELL1
VCELL1
VCELL1
CB1
CB1
CB1
VCELL0
VSS
VCELL0
VSS
VCELL0
VSS
4 Cells
5 Cells
3 Cells
VCELL8
VCELL8
VCELL8
CB8
CB8
CB8
VCELL7
VCELL7
VCELL7
CB7
VCELL6
CB7
VCELL6
CB7
VCELL6
CB6
CB6
CB6
VCELL5
VCELL5
VCELL5
CB5
CB5
CB5
VCELL4
VCELL4
VCELL4
CB4
CB4
CB4
VCELL3
VCELL3
VCELL3
CB3
CB3
CB3
VCELL2
VCELL2
VCELL2
CB2
CB2
CB2
VCELL1
VCELL1
VCELL1
CB1
CB1
CB1
VCELL0
VSS
VCELL0
VSS
VCELL0
VSS
Figure 52. Battery Connection Options Using the ISL94203EVKIT1Z Board
AN1952 Rev.3.00
May.9.19
Page 38 of 43
ISL94203EVKIT1Z
8.
8. Errata/Q&A
Errata/Q&A
Q: When I power the board, the device does not power up correctly. It looks like it is in sleep mode.
A: Before applying power to the evaluation board, disconnect the I2C cable. When the board is powered, connect
the I2C interface. The reason for this is that U2 on the board has internal protection diodes from the I2C traces to
RGO. When SCL and SDA pull up externally to 3.3V the ISL94203 is partially powered, so it does not complete its
power-up cycle.
Q: Cell measurement accuracy does not match the specifications in the datasheet.
A: There are some other potential reasons for inaccurate readings:
○ The source of measurement should have a low output impedance. A string of resistors that sets the input
voltages, like the MCB_PS_Z board can have small changes in the input voltage as the ISL94203 samples
each cell. Later models of the MCB_PS_Z board have 10µF capacitors across each input. These capacitors
should minimize sampling errors.
○ The ADC reading should be compared with the voltage on the PCB before the input resistors (at J2). If the
voltages are compared with DVM readings at the battery pack where there is a long cable, there should be
separate wires for GND and VC0; and for VC8 and VBAT. The reason for this is that the VBAT and GND leads
might carry a lot of current, so there can be voltage drops across the wires. The VC0 and VC8 terminals are
Kelvin connections that do not carry much current. Cell voltage measurements are based on VC0 and VC8,
not GND and VBAT.
○ Soldering the board to the PCB can change the stresses on the package from what they were during device
calibration. This can change the value of the voltage reference, which changes the ADC converted value.
This does not affect the relative voltage readings. If there is an external µC, an offset can be added to the µC
to correct for solder induced stresses.
Q: I changed the Pack Settings tab such that the CB during EOC button is checked. But after power cycling the
part, the CB during EOC is no longer checked and the part is not balancing during End of Charge.
A: After clicking on any of the option bits in the Pack Settings tab or on the main screen (above the FET control
indicators) it is necessary to do a Write EEPROM either on the Pack Settings tab or the Config Mem tab.
Without this write operation the change only resides in the ISL94203 Configuration RAM space.
Q: When I repeatedly read the EEPROM memory in the configuration tab, the communications lock up.
A: There was a problem with the old GUI code. The best solution is to get the new Win7/8 code. This new code
does not have this problem. Until you have the new code, the best way to clear this, without removing the battery
from the board, is to remove the I2C cable and use a jumper to momentarily connect and release the SCL line to
VSS (it is pulled up by a resistor). This creates a clock whine. Do this up to 9 times to clear the ISL94203 port.
Then reconnect the I2C cable.
AN1952 Rev.3.00
May.9.19
Page 39 of 43
ISL94203EVKIT1Z
9.
9. FET Gate Drive Rise/Fall Characteristics
FET Gate Drive Rise/Fall Characteristics
45
45
40
40
35
35
30
30
Amplitude (V)
Amplitude (V)
Verify basic digital logic, analog interface, level shifters, and charge pump operation.
25
20
15
25
20
15
10
10
5
5
0
0
Time (1ms/Div)
Time (100µs/Div)
Figure 54. DFET Fall
45
45
40
40
35
35
30
30
Amplitude (V)
Amplitude (V)
Figure 53. DFET Rise
25
20
15
25
20
15
10
10
5
5
0
0
Time (100µs/Div)
Figure 55. CFET Rise
AN1952 Rev.3.00
May.9.19
Time (100µs/Div)
Figure 56. CFET Fall
Page 40 of 43
ISL94203EVKIT1Z
10. Revision History
10. Revision History
Rev.
Date
Description
3.00
May.9.19
Updated to new template
Software Installation on page 3, step 1changed from: “Connect the ISLUSBI2C USB to the PC.” to: “Connect
the ISL94202INTFACEKIT1Z to the PC through the USB port.
Quick Hardware Setup on page 3: step 2 changed from: JP2/8Cell to: J13.
Updated Figure 2.
Removed mention of the Cascade feature.
- Pack Options section page 26, last paragraph deleted and Figure 36 replaced.
Added Revision History
Stamped Not Recommended for New Designs
Updated disclaimer