Bulletin PD-20745 rev. D 07/01
60EPU04 60APU04
Ultrafast Soft Recovery Diode
Features • Ultrafast Recovery • 175°C Operating Junction Temperature Benefits • Reduced RFI and EMI • Higher Frequency Operation • Reduced Snubbing • Reduced Parts Count Description/ Applications These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for HF welding, power converters and other applications where switching losses are not significant portion of the total losses.
trr = 50ns (typ) IF(AV) = 60Amp VR = 400V
Absolute Maximum Ratings Parameters
VR IF(AV) IFSM IFRM ! TJ, TSTG Cathode to Anode Voltage Continuous Forward Current, TC = 127°C Single Pulse Forward Current, TC = 25°C Maximum Repetitive Forward Current Operating Junction and Storage Temperatures
Max
400 60 600 120 - 55 to 175
Units
V A
°C
!" Square Wave, 20kHz
Case Styles
60EPU04
60APU04
CATHODE TO BASE 2
CATHODE TO BASE 2
1
3
1 ANODE
3 ANODE
CATHODE
ANODE
TO-247AC (Modified) www.irf.com
TO-247AC 1
60EPU04/ 60APU04
Bulletin PD-20745 rev. D 07/01
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
VBR, Vr VF Breakdown Voltage, Blocking Voltage Forward Voltage
Min Typ Max Units Test Conditions
400 V V V V µA mA pF nH IR = 100µA IF = 60A IF = 60A, TJ = 175°C IF = 60A, TJ = 125°C VR = VR Rated TJ = 150°C, VR = VR Rated VR = 400V Measured lead to lead 5mm from package body
1.05 1.25 0.87 1.03 0.93 1.10 50 3.5 50 2 -
IR
Reverse Leakage Current
-
CT LS
Junction Capacitance Series Inductance
-
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
trr Reverse Recovery Time
Min Typ Max Units Test Conditions
50 85 145 8.8 15.4 375 1120 60 nC A ns IF = 1A, diF/dt = 200A/µs, VR = 30V TJ = 25°C TJ = 125°C TJ = 25°C TJ = 125°C TJ = 25°C TJ = 125°C IF = 60A VR = 200V diF /dt = 200A/µs
IRRM
Peak Recovery Current
-
Qrr
Reverse Recovery Charge
-
Thermal - Mechanical Characteristics
Parameters
RthJC RthCS # Wt Thermal Resistance, Junction to Case Thermal Resistance, Case to Heatsink Weight 0.2 5.5 0.2 T Mounting Torque 1.2 10
#" Mounting Surface, Flat, Smooth and Greased
Min
Typ
Max
0.70
Units
K/W
g (oz) 2.4 20 N*m lbf.in
2
www.irf.com
60EPU04/ 60APU04
Bulletin PD-20745 rev. D 07/01
1000
Reverse Current - I R (µA)
1000
T J = 175˚C
100
125˚C
10 1 0.1 0.01 0.001
25˚C
Instantaneous Forward Current - I F (A)
100
T = 175˚C J T = 125˚C J T = 25˚C J
0
100
200
300
400
Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage
1000
Junction Capacitance - C T (pF)
10
T J = 25˚C
100
1 0 0.5
Forward Voltage Drop - VFM (V)
10
1
1.5
2
2.5
1
10
100
1000
Fig. 1 - Typical Forward Voltage Drop Characteristics
Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage
1
Thermal Impedance Z thJC (°C/W)
D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 Single Pulse (Thermal Resistance)
PDM
0.1
t1 t2 Notes: 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc
0.01 0.00001
0.0001
0.001 0.01 0.1 t1, Rectangular Pulse Duration (Seconds)
1
10
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
www.irf.com
3
60EPU04/ 60APU04
Bulletin PD-20745 rev. D 07/01
180
Allowable Case Temperature (°C) Average Power Loss ( Watts )
100 80
RMS Limit
160 140 120 Square wave (D = 0.50) 80% Rated Vr applied 100
see note (3)
DC
60 40 20 0
D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50 DC
80 0 20 40 60 80 100
Average Forward Current - IF(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current
0
20
40
60
80
100
Average Forward Current - IF(AV) (A) Fig. 6 - Forward Power Loss Characteristics
200 180 160 140 120 100 80 60 100
Vr = 400V Tj = 125˚C Tj = 25˚C
3500 3000
IF = 120A IF = 60A IF = 40A
Qrr ( nC )
Vr = 400V Tj = 125˚C Tj = 25˚C
2500 2000 1500 1000 500 0 100
di F /dt (A/µs ) Fig. 8 - Typical Stored Charge vs. di F /dt
trr ( ns )
IF = 120A IF = 60A IF = 40A
di F /dt (A/µs )
1000
1000
Fig. 7 - Typical Reverse Recovery time vs. di F /dt
(3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = 80% rated VR
4
www.irf.com
60EPU04/ 60APU04
Bulletin PD-20745 rev. D 07/01
Reverse Recovery Circuit
VR = 200V
0.01 Ω L = 70µH D.U.T.
di F /dt dif/dt ADJUST
D G IRFP250 S
Fig. 9- Reverse Recovery Parameter Test Circuit
3
IF 0
trr ta tb
4
2
Q rr I RRM
0.5 I RRM di(rec)M/dt 0.75 I RRM
5
1
di fF/dt /dt
1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current
4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr
Fig. 10 - Reverse Recovery Waveform and Definitions
www.irf.com
5
60EPU04/ 60APU04
Bulletin PD-20745 rev. D 07/01
Outline Table
15.90 (0.626) 15.30 (0.602) 5.70 (0.225) 5.30 (0.208) 20.30 (0.800) 19.70 (0.775) 5.50 (0.217) 4.50 (0.177) (2 PLCS.)
1 3
3.65 (0.144) 3.55 (0.139) DIA.
5.30 (0.209) 4.70 (0.185) 2.5 (0.098) 1.5 (0.059)
60EPU04 2 pins
CATHODE TO BASE
2
1 14.80 (0.583) 14.20 (0.559)
3
4.30 (0.170) 3.70 (0.145)
CATHODE
ANODE
1.40 (0.056) 1.00 (0.039) 10.94 (0.430) 10.86 (0.427)
2.20 (0.087) MAX. 0.80 (0.032) 0.40 (0.213)
2.40 (0.095) MAX.
Conforms to JEDEC Outline TO-247AC (Modified) Dimensions in millimeters and (inches)
15.90 (0.626) 15.30 (0.602)
3.65 (0.144) 3.55 (0.139) DIA.
5.30 (0.209) 4.70 (0.185) 2.5 (0.098) 1.5 (0.059)
60APU04 3 pins
5.70 (0.225) 5.30 (0.208) 20.30 (0.800) 19.70 (0.775) 5.50 (0.217) 4.50 (0.177) (2 PLCS.)
CATHODE TO BASE
2
1 14.80 (0.583) 14.20 (0.559)
2
3
1 ANODE
3 ANODE
4.30 (0.170) 3.70 (0.145) 2.20 (0.087) MAX. 3.20 (0.126) MAX. 0.80 (0.032) 0.40 (0.213) 2.40 (0.095) MAX.
1.40 (0.056) 1.00 (0.039) 5.47 (0.216) 5.43 (0.213)
Conforms to JEDEC Outline TO-247AC Dimensions in millimeters and (inches)
6
www.irf.com
60EPU04/ 60APU04
Bulletin PD-20745 rev. D 07/01
Ordering Information Table
Device Code
60
1
E
2
P
3
U
4
04
5
1 2 3 4 5
-
Current Rating Single Diode TO-247AC (Modified) Ultrafast Recovery Voltage Rating
(60 = 60A)
E = 2 pins A = 3 pins
(04 = 400V)
Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 2 33 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 07/01
www.irf.com
7
很抱歉,暂时无法提供与“60APU04”相匹配的价格&库存,您可以联系我们找货