0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
60APU04

60APU04

  • 厂商:

    IRF

  • 封装:

  • 描述:

    60APU04 - Ultrafast Soft Recovery Diode - International Rectifier

  • 数据手册
  • 价格&库存
60APU04 数据手册
Bulletin PD-20745 rev. D 07/01 60EPU04 60APU04 Ultrafast Soft Recovery Diode Features • Ultrafast Recovery • 175°C Operating Junction Temperature Benefits • Reduced RFI and EMI • Higher Frequency Operation • Reduced Snubbing • Reduced Parts Count Description/ Applications These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for HF welding, power converters and other applications where switching losses are not significant portion of the total losses. trr = 50ns (typ) IF(AV) = 60Amp VR = 400V Absolute Maximum Ratings Parameters VR IF(AV) IFSM IFRM ! TJ, TSTG Cathode to Anode Voltage Continuous Forward Current, TC = 127°C Single Pulse Forward Current, TC = 25°C Maximum Repetitive Forward Current Operating Junction and Storage Temperatures Max 400 60 600 120 - 55 to 175 Units V A °C !" Square Wave, 20kHz Case Styles 60EPU04 60APU04 CATHODE TO BASE 2 CATHODE TO BASE 2 1 3 1 ANODE 3 ANODE CATHODE ANODE TO-247AC (Modified) www.irf.com TO-247AC 1 60EPU04/ 60APU04 Bulletin PD-20745 rev. D 07/01 Electrical Characteristics @ TJ = 25°C (unless otherwise specified) Parameters VBR, Vr VF Breakdown Voltage, Blocking Voltage Forward Voltage Min Typ Max Units Test Conditions 400 V V V V µA mA pF nH IR = 100µA IF = 60A IF = 60A, TJ = 175°C IF = 60A, TJ = 125°C VR = VR Rated TJ = 150°C, VR = VR Rated VR = 400V Measured lead to lead 5mm from package body 1.05 1.25 0.87 1.03 0.93 1.10 50 3.5 50 2 - IR Reverse Leakage Current - CT LS Junction Capacitance Series Inductance - Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified) Parameters trr Reverse Recovery Time Min Typ Max Units Test Conditions 50 85 145 8.8 15.4 375 1120 60 nC A ns IF = 1A, diF/dt = 200A/µs, VR = 30V TJ = 25°C TJ = 125°C TJ = 25°C TJ = 125°C TJ = 25°C TJ = 125°C IF = 60A VR = 200V diF /dt = 200A/µs IRRM Peak Recovery Current - Qrr Reverse Recovery Charge - Thermal - Mechanical Characteristics Parameters RthJC RthCS # Wt Thermal Resistance, Junction to Case Thermal Resistance, Case to Heatsink Weight 0.2 5.5 0.2 T Mounting Torque 1.2 10 #" Mounting Surface, Flat, Smooth and Greased Min Typ Max 0.70 Units K/W g (oz) 2.4 20 N*m lbf.in 2 www.irf.com 60EPU04/ 60APU04 Bulletin PD-20745 rev. D 07/01 1000 Reverse Current - I R (µA) 1000 T J = 175˚C 100 125˚C 10 1 0.1 0.01 0.001 25˚C Instantaneous Forward Current - I F (A) 100 T = 175˚C J T = 125˚C J T = 25˚C J 0 100 200 300 400 Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage 1000 Junction Capacitance - C T (pF) 10 T J = 25˚C 100 1 0 0.5 Forward Voltage Drop - VFM (V) 10 1 1.5 2 2.5 1 10 100 1000 Fig. 1 - Typical Forward Voltage Drop Characteristics Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage 1 Thermal Impedance Z thJC (°C/W) D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 Single Pulse (Thermal Resistance) PDM 0.1 t1 t2 Notes: 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc 0.01 0.00001 0.0001 0.001 0.01 0.1 t1, Rectangular Pulse Duration (Seconds) 1 10 Fig. 4 - Max. Thermal Impedance Z thJC Characteristics www.irf.com 3 60EPU04/ 60APU04 Bulletin PD-20745 rev. D 07/01 180 Allowable Case Temperature (°C) Average Power Loss ( Watts ) 100 80 RMS Limit 160 140 120 Square wave (D = 0.50) 80% Rated Vr applied 100 see note (3) DC 60 40 20 0 D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50 DC 80 0 20 40 60 80 100 Average Forward Current - IF(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current 0 20 40 60 80 100 Average Forward Current - IF(AV) (A) Fig. 6 - Forward Power Loss Characteristics 200 180 160 140 120 100 80 60 100 Vr = 400V Tj = 125˚C Tj = 25˚C 3500 3000 IF = 120A IF = 60A IF = 40A Qrr ( nC ) Vr = 400V Tj = 125˚C Tj = 25˚C 2500 2000 1500 1000 500 0 100 di F /dt (A/µs ) Fig. 8 - Typical Stored Charge vs. di F /dt trr ( ns ) IF = 120A IF = 60A IF = 40A di F /dt (A/µs ) 1000 1000 Fig. 7 - Typical Reverse Recovery time vs. di F /dt (3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = 80% rated VR 4 www.irf.com 60EPU04/ 60APU04 Bulletin PD-20745 rev. D 07/01 Reverse Recovery Circuit VR = 200V 0.01 Ω L = 70µH D.U.T. di F /dt dif/dt ADJUST D G IRFP250 S Fig. 9- Reverse Recovery Parameter Test Circuit 3 IF 0 trr ta tb 4 2 Q rr I RRM 0.5 I RRM di(rec)M/dt 0.75 I RRM 5 1 di fF/dt /dt 1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current 4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr Fig. 10 - Reverse Recovery Waveform and Definitions www.irf.com 5 60EPU04/ 60APU04 Bulletin PD-20745 rev. D 07/01 Outline Table 15.90 (0.626) 15.30 (0.602) 5.70 (0.225) 5.30 (0.208) 20.30 (0.800) 19.70 (0.775) 5.50 (0.217) 4.50 (0.177) (2 PLCS.) 1 3 3.65 (0.144) 3.55 (0.139) DIA. 5.30 (0.209) 4.70 (0.185) 2.5 (0.098) 1.5 (0.059) 60EPU04 2 pins CATHODE TO BASE 2 1 14.80 (0.583) 14.20 (0.559) 3 4.30 (0.170) 3.70 (0.145) CATHODE ANODE 1.40 (0.056) 1.00 (0.039) 10.94 (0.430) 10.86 (0.427) 2.20 (0.087) MAX. 0.80 (0.032) 0.40 (0.213) 2.40 (0.095) MAX. Conforms to JEDEC Outline TO-247AC (Modified) Dimensions in millimeters and (inches) 15.90 (0.626) 15.30 (0.602) 3.65 (0.144) 3.55 (0.139) DIA. 5.30 (0.209) 4.70 (0.185) 2.5 (0.098) 1.5 (0.059) 60APU04 3 pins 5.70 (0.225) 5.30 (0.208) 20.30 (0.800) 19.70 (0.775) 5.50 (0.217) 4.50 (0.177) (2 PLCS.) CATHODE TO BASE 2 1 14.80 (0.583) 14.20 (0.559) 2 3 1 ANODE 3 ANODE 4.30 (0.170) 3.70 (0.145) 2.20 (0.087) MAX. 3.20 (0.126) MAX. 0.80 (0.032) 0.40 (0.213) 2.40 (0.095) MAX. 1.40 (0.056) 1.00 (0.039) 5.47 (0.216) 5.43 (0.213) Conforms to JEDEC Outline TO-247AC Dimensions in millimeters and (inches) 6 www.irf.com 60EPU04/ 60APU04 Bulletin PD-20745 rev. D 07/01 Ordering Information Table Device Code 60 1 E 2 P 3 U 4 04 5 1 2 3 4 5 - Current Rating Single Diode TO-247AC (Modified) Ultrafast Recovery Voltage Rating (60 = 60A) E = 2 pins A = 3 pins (04 = 400V) Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 2 33 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 07/01 www.irf.com 7
60APU04 价格&库存

很抱歉,暂时无法提供与“60APU04”相匹配的价格&库存,您可以联系我们找货

免费人工找货