    IRKD600 - STANDARD DIODES SUPER MAGM-A-part™ Power Modules - International Rectifier

  • 数据手册
  • 价格&库存
IRKD600 数据手册
Bulletin I27402 rev. B 09/06 IRKD600.. SERIES STANDARD DIODES Features High current capability 3000 VRMS isolating voltage with non-toxic substrate High surge capability High voltage ratings up to 2000V Industrial standard package UL E78996 approved RoHS Compliant SUPER MAGN-A-pakTM Power Modules 600 A Typical Applications Rectifying bridge for large motor drives Rectifying bridge for large UPS Major Ratings and Characteristics Parameters IF(AV) @ TC IF(RMS) @ TC IFSM I2t @ 50Hz @ 60Hz @ 50Hz @ 60Hz I2√t VRRM TSTG TJ range range range IRKD600.. 600 100 942 100 19.0 20.1 1805 1683 18050 800 to 2000 - 40 to 150 - 40 to 150 Units A °C A °C KA KA KA2s KA2s KA2√s V °C °C www.irf.com 1 IRKD600.. Series Bulletin I27402 rev. B 09/06 ELECTRICAL SPECIFICATIONS Voltage Ratings Type number Voltage Code 08 IRKD600.. 12 16 20 VRRM , maximum repetitive peak reverse voltage V 800 1200 1600 2000 VRSM , maximum nonrepetitive peak rev. voltage V 900 1300 1700 2100 IRRM max. @ TJ max. mA 50 Forward Conduction Parameter I F(AV) Maximum average forward current @ Case temperature I F(RMS) Maximum RMS forward current I FSM Maximum peak, one-cycle forward, non-repetitive surge current IRKD600.. 600 100 942 19.0 20.1 16.2 17.2 Units Conditions A °C A KA 180° conduction, half sine wave @ TC = 100°C t = 10ms t = 8.3ms t = 10ms t = 8.3ms KA2s t = 10ms t = 8.3ms t = 10ms t = 8.3ms 2 180° conduction, half sine wave No voltage reapplied 100% VRRM reapplied No voltage reapplied 100% VRRM reapplied Sinusoidal half wave, Initial TJ = TJ max. I2t Maximum I2t for fusing 1805 1683 1319 1230 I √t 2 Maximum I √t for fusing 2 18050 0.70 0.77 0.28 0.25 1.24 KA √s t = 0.1 to 10ms, no voltage reapplied V (16.7% x π x IF(AV) < I < π x IF(AV)), TJ = TJ max. (I > π x IF(AV)), TJ = TJ max. mΩ (16.7% x π x IF(AV) < I < π x IF(AV)), TJ = TJ max. (I > π x IF(AV)), TJ = TJ max. V Ipk = 1800A, TJ = 25°C, tp = 10ms sine pulse VF(TO)1 Low level value of threshold voltage VF(TO)2 High level value of threshold voltage r f1 r f2 VFM Low level value of forward slope resistance High level value of forward slope resistance Maximum forward voltage drop Blocking Parameter V INS I RRM RMS isolation voltage Maximum peak reverse and off-state leakage current IRKD600.. 3000 50 Units Conditions V mA t=1s TJ = TJ max., rated VRRM applied 2 www.irf.com IRKD600.. Series Bulletin I27402 rev. B 09/06 Thermal and Mechanical Specifications Parameter TJ Tstg R thJC Max. junction operating temperature range Max. storage temperature range Max. thermal resistance, junction to case R thC-hs Max. thermal resistance, case to heatsink T Mounting torque ± 10%SMAP to heatsink busbar to SMAP wt Approximate weight Case style 6-8 12 - 15 1500 g Nm A mounting compound is recommended and the torque should be rechecked after a period of 3 hours to allow for the spread of the compound IRKD600.. - 40 to 150 - 40 to 150 0.065 Units Conditions °C K/W Per junction, DC operation 0.02 K/W SUPER MAGN-A-pak See outline table ΔRthJC Conduction (The following table shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC) Conduction angle 180° 120° Sinusoidal conduction 0.009 0.011 90° 60° Rectangular conduction 0.006 0.011 0.014 0.021 30° Units Conditions 0.015 0.022 0.037 K/W TJ = TJ max. 0.038 Ordering Information Table 1 Device Code ~ IRK 1 1 2 3 4 Module type D 2 600 3 - 20 4 + 2 Circuit configuration D = 2 diodes in series Current rating Voltage code: Code x 100 = VRRM (See Voltage Ratings Table) 3 www.irf.com 3 IRKD600.. Series Bulletin I27402 rev. B 09/06 Outline Table All dimensions in millimeters (inches) Ma ximum Allowable Cas T e emperature (°C) 140 130 120 110 100 IRKD600.. S eries R thJC (DC) = 0.065 K/ W Maximum Allowab le Ca s T e emperature (°C) 150 150 140 130 120 110 100 30° 90 80 0 200 400 600 800 1000 Average Forward Current (A) 60° 90° 120° 180° DC Conduction Period IRKD600.. S eries R thJC (DC) = 0.065 K/ W Conduction Angle 30° 90 80 0 100 200 300 60° 90° 120° 180° 400 500 600 700 Average Forward Current (A) Fig. 1 - Current Ratings Characteristics Fig. 2 - Current Ratings Characteristics 4 www.irf.com IRKD600.. Series Bulletin I27402 rev. B 09/06 700 600 500 400 300 200 100 0 0 100 200 300 400 500 600 Average Forward Current (A) Conduction Angle Maximum Average Forward Power Loss (W) Maximum Average Forward Power Loss (W) 1000 900 800 700 600 500 400 300 200 100 0 0 200 400 600 800 1000 Average Forward Current (A) IRKD600.. S eries Per Junction TJ= 150°C R MS Limit Conduction Period 180° 120° 90° 60° 30° RMS Limit DC 180° 120° 90° 60° 30° IRKD600.. S eries Per Junction T = 150°C J Fig. 3 - Forward Power Loss Characteristics Peak Half S Wave Forward Current (A) ine 18000 Fig. 4 - Forward Power Loss Characteristics 20000 18000 16000 14000 12000 10000 8000 6000 4000 0.01 IR KD600.. S eries Per Junction 0.1 Pulse Train Duration (s) 1 Peak Half S Wave Forward Current (A) ine At Any R ated Load Condition And With R ated VRRM Applied Following S urge. 16000 Initial T = 150°C J @60 Hz 0.0083 s 14000 @50 Hz 0.0100 s 12000 10000 8000 6000 4000 1 10 100 Numb er Of Equa l Amplitude Half Cyc le Current Pulses (N) Maximum Non Repetitive S urge Current Versus Pulse T rain Dura tion. Initial T = 150°C J No Voltage Reapplied Rated VRRM Rea pplied IRKD600.. S eries Per Junc tion Fig. 5 - Maximum Non-Repetitive Surge Current 1000 Fig. 6 - Maximum Non-Repetitive Surge Current Maximum T otal F orward Power Loss (W) R th 04 0. DC 800 600 180° (S ine) K/ W 0. 12 K/ W 0.1 6K /W 0. 08 400 IR KD600.. S eries Per Junc tion T = 150°C J 0 200 400 600 800 200 0.2 5K /W 0.3 5K /W 0.5 K /W 06 0. A S W K/ W K/ = 2 0.0 W K/ ta el -D R 0 1000 0 25 50 75 100 125 150 T otal R MSOutput Current (A) Maximum Allowable Ambient T emperature (°C) Fig. 7 - Forward Power Loss Characteristics www.irf.com 5 IRKD600.. Series Bulletin I27402 rev. B 09/06 3000 R th 02 0. Maximum T otal Power Loss (W) 2500 2000 1500 1000 500 0 0 200 400 180° (S ine) 180° (R t) ec K/ W 0. 04 K/ W 0.0 5K /W 0. 03 A S W K/ = /W 1K 0.0 ta el -D 0.0 8K /W 0.12 K/ W R 2 x IR KD600.. S eries S ingle Phase Bridge Connected TJ = 150°C 600 800 1000 0.2 K / W 1200 0 25 50 75 100 125 150 T otal Output Current (A) Maximum Allowable Ambient T emperature (°C) Fig. 8 - Forward Power Loss Characteristics 4500 R th Maximum T otal Power Loss (W) 4000 3500 3000 2500 2000 1500 1000 500 0 0 300 600 900 1200 1500 0 1800 3 x IRKD600.. S eries T hree Phase Bridge Connected T J = 150°C 120° (Rec t) 0. 02 K/ W 0.0 3K /W 0.0 5K /W A S = 01 0. W K/ ta el -D R W 0.12 K /W 0.2 K/ W 0.08 K/ 25 50 75 100 125 150 T otal Output Current (A) Maximum Allowable Ambient T emperature (°C) Fig. 9 - Forward Power Loss Characteristics 10000 Ins tantaneous Forward Current (A) 0.1 IRKD600.. S eries Per Junc tion 1000 TJ= 25°C TJ= 150°C T ransient T hermal Impedance ZthJC (K/ W) 0.01 S teady S tate Value: RthJC = 0.065 K/ W (DC Operation) 0.001 0.001 0.01 0.1 1 10 100 IRKD600.. S eries Per Junction 100 0.5 1 1.5 2 2.5 3 3.5 Instantaneous Forward Voltage (V) S quare Wave Puls Duration (s) e Fig. 10 - Forward Voltage Drop Characteristics Fig. 11 - Thermal Impedance ZthJC Characteristic 6 www.irf.com IRKD600.. Series Bulletin I27402 rev. B 09/06 Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 2 33 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 09/06 www.irf.com 7
IRKD600 价格&库存

很抱歉,暂时无法提供与“IRKD600”相匹配的价格&库存,您可以联系我们找货

免费人工找货