Bulletin PD-21047 05/05
IRUD400CW60
FRED TM
Features • Ultrafast Recovery • Lead-Free Benefits • • • • Reduced RFI and EMI Higher Frequency Operation Reduced Snubbing Reduced Parts Count
LUG TERMINAL ANODE 1 LUG TERMINAL ANODE 2
Ultrafast, Soft Recovery Diode
VR = 600V IF(AV) = 400A
BASE COMMON CATHODE
Description/ Applications These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for HF welding, power converters and other applications where switching losses are significant portion of the total losses.
Absolute Maximum Ratings Parameters (*)
VR IF(AV) Cathode-to-Anode Voltage Continuous Forward Current @ TC = 25°C @ TC = 85°C @ TC = 97°C IFSM PD Single Pulse Forward Current Maximum Power Dissipation @ TC = 25°C @ TC = 97°C
Max
600 330 230 200 1200 660 280
Units
V A
W
Case Styles
IRUD400CW60
TO-244
(*) Per Leg unless otherwise specified
1
IRUD400CW60
Bulletin PD-21047 05/05
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameters
VBR VFM Breakdown Voltage, Forward Voltage
Min Typ Max Units Test Conditions
600 1.45 1.67 1.13 1.39 0.3 5 2.0 2.3 1.4 1.8 1.38 mA nH V IR = 100µA IF = 200A IF = 400A IF = 200A @ TJ = 150°C IF = 400A @ TJ = 150°C TJ = 150°C, VR = VR Rated from top of terminal hole to mounting plane
IRM LS
Reverse Leakage Current Series Inductance
-
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
trr Reverse Recovery Time
Min Typ Max Units Test Conditions
90 240 8.3 24 830 4730 nC A ns If = 200A, dif/dt = 200A/µs, Vr = 200V If = 200A, dif/dt =200A/µs, Vr =200V @ TJ = 150°C If = 200A, dif/dt = 200A/µs, Vr = 200V If = 200A, dif/dt =200A/µs, Vr =200V @ TJ = 150°C If = 200A, dif/dt = 200A/µs, Vr = 200V If = 200A, dif/dt =200A/µs, Vr =200V @ TJ = 150°C
IRRM
Peak Recovery Current
-
Qrr
Reverse Recovery Charge
-
Thermal - Mechanical Characteristics
Parameters
TJ TStg RthJC RthCS Wt T Max. Junction Temperature Range Max. Storage Temperature Range Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Thermal Resistance, Case to Heatsink Weight Mounting Torque Mounting Torque Center Hole Terminal Torque Vertical Pull 2 inch. Lever Pull Per Leg Per Module
Min
- 40 - 40 30 (3.4) 12 (1.4) 30 (3.4) -
Typ
0.10 68 (2.4) -
Max
150 150 0.19 0.095 40 (4.6) 18 (2.1) 40 (4.6) 80 35
Units
°C °C/W
g (oz) lbf.in (N.m) lbf.in
2
IRUD400CW60
Bulletin PD-21047 05/05
1000
Reverse Current - IR (µA)
1000
100 10 1 0.1 0.01 0
TJ = 150˚C
25˚C
Instantaneous Forward Current - IF (A)
100
100 200 300 400 500 Reverse Voltage - VR (V)
600
Fig. 2 - Typical Reverse Current vs. Reverse Voltage (per Leg)
Allowable Case Temperature (°C)
10
Tj = 150˚C Tj = 25˚C
160
IRUD400CW60 RthJC = 0.19 K/W
140 120
(D = 0.50)
DC
100 80 60 0 50 100 150 200 Current Rating - IDC (A) 250
1 0 0.5 1 1.5 Forward Voltage Drop - VFM (V)
Fig. 1 - Typical Forward Voltage Drop vs. Instantaneous Forward Current (per Leg)
2
Fig. 3 - Max. Current Rating Capability (per Leg)
3
IRUD400CW60
Bulletin PD-21047 05/05
200
Forward Power Loss (W)
300
RMS Limit
If = 200A Vrr = 200V
150
DC
200
Tj = 150˚C
100
50
D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50
t rr (ns)
100
0 0 50 100 150 200
Forward Current (A) Fig. 4 - Typical Recovery Current vs. dif /dt (per Leg)
Tj = 25˚C
0 100
200
300
400
500
dif/ dt - (A/µs) Fig. 5 - Typical Reverse Recovery Time vs. dif /dt (per Leg)
8000
If = 200A Vrr = 200V
40
If = 200A Vrr = 200V
6000
Tj = 150˚C
Q RR (nC)
30
Tj = 150˚C
4000
I RR (A)
20
2000
Tj = 25˚C
10
Tj = 25˚C
0 100
200
300
dif/ dt - (A/µs)
400
500
0 100
200
300
dif/ dt - (A/µs)
400
500
Fig. 6 - Typical Reverse Recovery Charge vs. dif /dt (per Leg)
Fig. 7 - Typical Reverse Recovery Current vs. dif /dt (per Leg)
4
IRUD400CW60
Bulletin PD-21047 05/05
Reverse Recovery Circuit
VR = 200V
0.01 Ω L = 70µH D.U.T. dif/dt ADJUST
di F /dt
D G IRFP250 S
Fig. 8 - Reverse Recovery Parameter Test Circuit
Outline Table
Conforms to JEDEC Outline TO-244 Dimensions in millimeters and (inches)
5
IRUD400CW60
Bulletin PD-21047 05/05
Ordering Information Table
Device Code
IR
1 1 2 3 4 5 6 -
UD
2
400
3
C
4
W
5
60
6
International Rectifier UD = Fred Current Rating (400 = 400A) Circuit Configuration (C = Common Cathode) W = TO-244 Wire Bondable not Isolated Voltage Rating (60 = 600V)
Data and specifications subject to change without notice. This product has been designed for Industrial Level. Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 2 33 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 05/05
6
很抱歉,暂时无法提供与“IRUD400CW60”相匹配的价格&库存,您可以联系我们找货
免费人工找货