Bulletin PD-21081 08/05
MURB1020CTPbF MURB1020CT-1PbF
Ultrafast Rectifier
Features
• • • • • Ultrafast Recovery Time Low Forward Voltage Drop Low Leakage Current 175°C Operating Junction Temperature Lead-Free ("PbF" suffix)
trr = 25ns IF(AV) = 10Amp VR = 200V
Description/ Applications International Rectifier's MUR.. series are the state of the art Ultra fast recovery rectifiers specifically designed with optimized performance of forward voltage drop and ultra fast recovery time. The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as free-wheeling diode in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers.
Absolute Maximum Ratings Parameters
VRRM IF(AV) IFSM IFM TJ, TSTG Peak Repetitive Peak Reverse Voltage Average Rectified Forward Current Total Device, (Rated VR ), TC = 149°C Non Repetitive Peak Surge Current Peak Repetitive Forward Current (Rated VR , Square wave, 20 KHz), TC = 149°C Operating Junction and Storage Temperatures - 65 to 175 °C Per Leg Total Device Per Leg Per Leg
Max
200 5 10 50 10
Units
V A
Case Styles
MURB1020CTPbF
MURB1020CT-1PbF
BASE COMMON CATHODE 2
BASE COMMON CATHODE 2
1
2
3
1
2
3
A NODE COMMON ANODE CATHODE 1 2
A NODE COMMON ANODE CATHODE 1 2
D2PAK www.irf.com
TO-262 1
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
VBR, Vr VF Breakdown Voltage, Blocking Voltage Forward Voltage
Min Typ Max Units Test Conditions
200 V V V V µA µA pF nH IR = 100µA IF = 5A, TJ = 125°C IF = 10A, TJ = 125°C IF = 10A, TJ = 25°C VR = V R Rated TJ = 150°C, VR = V R Rated VR = 200V Measured lead to lead 5mm from package body .
0.87 0.99 1.02 1.20 1.12 1.25 8 8.0 10 250 -
IR
Reverse Leakage Current
-
CT LS
Junction Capacitance Series Inductance
-
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
trr Reverse Recovery Time
Min Typ Max Units Test Conditions
24 35 35 25 ns IF = 1.0A, diF/dt = 50A/µs, VR = 30V IF = 0.5A, IR = 1.0A, IREC = 0.25A TJ = 25°C TJ = 125°C nC A TJ = 25°C TJ = 125°C TJ = 25°C TJ = 125°C IF = 5A VR = 160V diF /dt = 200A/µs
IRRM
Peak Recovery Current
-
3.3 5.0 33 76
Qrr
Reverse Recovery Charge
-
Thermal - Mechanical Characteristics
Parameters
TJ TStg RthJC RthJA RthCS Wt Max. Junction Temperature Range Max. Storage Temperature Range Thermal Resistance, Junction to Case Per Leg
Min
- 65 - 65 -
Typ
0.5 2.0 0.07 -
Max
175 175 5 50 12 10
Units
°C
°C/W
Thermal Resistance, Junction to Ambient Per Leg Thermal Resistance, Case to Heatsink Weight
g (oz) Kg-cm lbf.in
2
Mounting Torque
6.0 5.0
Marking Device
MURB1020CT MURB1020CT-1
Case style D Pak Case style TO-262
Mounting Surface, Flat, Smooth and Greased
2
www.irf.com
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
100
100 10 1 0.1 0.01
25˚C TJ = 175˚C 150˚C 125˚C 100˚C
Instantaneous Forward Current - I F (A)
10
Reverse Current - I R (µA)
0.001
0.0001
T = 175˚C J T = 125˚C J T = 25˚C J
0
40
80
120
160
200
Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage
100
Junction Capacitance - C T (pF)
T = 25˚C
J
1
10
0.1 0.2
1
0.4 0.6 0.8 1 1.2 1.4 1.6
1
10
100
1000
Forward Voltage Drop - VFM (V) Fig. 1 - Typical Forward Voltage Drop Characteristics
Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage
10
(°C/W)
thJC
Thermal Impedance Z
1
D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01
Notes:
PDM
t1 t2
0.1
Single Pulse (Thermal Resistance)
1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc
0.01 0.00001
0.0001
0.001
0.01
0.1
1
t1, Rectangular Pulse Duration (Seconds) Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
www.irf.com
3
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
180
Allowable Case Temperature (°C) Average Power Loss ( Watts )
7
RMS Limit
6 5 4 3 2 1 0
D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5 DC
170 160 150 Square wave (D = 0.50)
Rated Vr applied
DC
140
see note (2)
130 0 2 4 6 8
Average Forward Current - IF(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current
0
1
2
3
4
5
6
7
8
Average Forward Current - IF(AV) (A) Fig. 6 - Forward Power Loss Characteristics
50
I F = 10 A IF = 5 A
160 140 120 100
Qrr ( nC )
I F = 10 A IF = 5 A
VR = 160V TJ = 125˚C TJ = 25˚C
40
trr ( ns )
30
80 60
20
VR = 160V TJ = 125˚C TJ = 25˚C
40 20 0 100
di F /dt (A/µs ) Fig. 8 - Typical Stored Charge vs. di F /dt
10 100
di F /dt (A/µs )
1000
1000
Fig. 7 - Typical Reverse Recovery vs. di F /dt
(2) Formula used: TC = T J - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = V R1 x IR (1 - D); IR @ V R1 = rated VR
4
www.irf.com
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Reverse Recovery Circuit
VR = 200V
0.01 Ω L = 70µH D.U.T.
di F /dt dif/dt ADJUST
D G IRFP250 S
Fig. 9- Reverse Recovery Parameter Test Circuit
3
IF 0
t rr ta tb
4
2
Q rr I RRM
0.5 I RRM di(rec)M/dt 0.75 I RRM
5
1
/dt di fF/dt
4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr
1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 I RRM extrapolated to zero current
Fig. 10 - Reverse Recovery Waveform and Definitions
www.irf.com
5
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Outlines Table
BASE COMMON CATHODE 2
1
2
3
A NODE COMMON ANODE CATHODE 1 2
Conform to JEDEC outline D2Pak (SMD-220) Dimensions in millimeters and (inches)
Modified JEDEC outline TO-262 Dimensions in millimeters and (inches)
BASE COMMON CATHODE 2
1
2
3
A NODE COMMON ANODE CATHODE 1 2
NC
6
www.irf.com
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Part Marking Information
D2PAK
PART NUMBER
MURB1020CT
THIS IS A MURB1020CT LOT CODE 8024 ASSEMBLED ON WW 02, 2000
INTERNATIONAL RECTIFIER LOGO ASSEMBLY LOT CODE
DATE CODE YEAR 0 = 2000 WEEK 02 P = LEAD-FREE
TO-262
THIS IS A MURB1020CT-1 LOT CODE 8024 ASSEMBLED ON WW 02, 2000
INTERNATIONAL RECTIFIER LOGO ASSEMBLY LOT CODE
PART NUMBER
MURB1020CT-1
DATE CODE YEAR 0 = 2000 WEEK 02 P = LEAD-FREE
www.irf.com
7
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Tape & Reel Information
TRR
1.60 (0.063) 1.50 (0.059)
4.10 (0.161) 3.90 (0.153) FEED DIRECTION
1.60 (0.063) 1.50 (0.059)
DIA. 0.368 (0.0145) 0.342 (0.0135)
1.85 (0.073) 1.65 (0.065)
11.60 (0.457) 11.40 (0.449)
15.42 (0.609) 15.22 (0.601) 1.75 (0.069) 24.30 (0.957) 23.90 (0.941)
TRL
10.90 (0.429) 10.70 (0.421)
1.25 (0.049) 16.10 (0.634) 15.90 (0.626)
DIA.
4.72 (0.186) 4.52 (0.178)
FEED DIRECTION
13.50 (0.532) 12.80 (0.504)
DIA.
26.40 (1.039) 24.40 (0.961)
SMD-220 Tape & Reel When ordering, indicate the part number, part orientation, and the quantity. Quantities are in multiples
60 (2.362) D IA . MIN.
360 (14.173) DIA. MAX.
of 800 pieces per reel for both TRL and T RR.
Dimensions in millimeters and (inches)
8
www.irf.com
MURB1020CTPbF, MURB1020CT-1PbF
Bulletin PD-21081 08/05
Ordering Information Table
Device Code
MUR
1
B
2
10
3
20
4
CT
5
-1
6
TRL PbF
7 8
1 2 3 4 5 6 7 6 8
-
Ultrafast MUR Series B = D2Pak/ TO-262 Current Rating (10 = 10A) Voltage Rating (20 = 200V) CT -1 = Center Tap (Dual) TO-220 /D2PAK/ TO-262 = TO-262
none = Tube (50 pieces) TRL = Tape & Reel (Left Oriented, for D2PAk package) TRR = Tape & Reel (Right Oriented, for D 2PAk package)
-
none = Standard Production PbF = Lead-Free
Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level and Lead-Free. Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 2 33 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 08/05
www.irf.com
9