0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
OM1915N2M

OM1915N2M

  • 厂商:

    IRF

  • 封装:

  • 描述:

    OM1915N2M - HERMETIC SURFACE MOUNT FIXED VOLTAGE NEGATIVE REGULATORS APPROVED TO DESC DRAWING - Inte...

  • 数据手册
  • 价格&库存
OM1915N2M 数据手册
OM1905N2M OM1912N2M OM1915N2M HERMETIC SURFACE MOUNT FIXED VOLTAGE NEGATIVE REGULATORS APPROVED TO DESC DRAWING LCC 20, Fixed Voltage, Precision Negative Regulators In Hermetic Surface Mount Package FEATURES • • • • • • Hermetic Surface Mount Package Output Voltages: -5V, -12V, -15V Output Voltages Set Internally To ±1% Built-In Thermal Overload Protection Short Circuit Current Limiting Product Is Available Hi-Rel Screened DESCRIPTION These negative regulators are supplied in a hermetically sealed surface mount package. All protective features are designed into the circuit including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over .5 amps of output current. These units feature internally trimmed output voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, and -15V. These units are ideally suited for Military applications where a hermetic surface mount package is required. PART NUMBER DESIGNATOR Standard Military Drawing Number 5962-8874601 2X 5962-8874701 2X 5962-8874801 2X Omnirel Part Number OM1905N2M OM1912N2M OM1915N2M 3.5 4 11 R0 3.5 - 49 OM1905N2M - OM1915N2M ABSOLUTE MAXIMUM RATINGS @ 25°C Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C Typical Power/Thermal Charateristics: Rated Power @ 25° C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2W TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1040 mW Thermal Resistance θJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25°C/W θJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120°C/W ELECTRICAL CHARACTERISTICS -5 Volt Parameter Output Voltage Symbol VOUT VIN = -10V, Io = 100mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified) Min. -4.95 Max. -5.05 -5.15 Unit V V Test Conditions TA = 25°C VIN = -7.5V to -20V IO = 5 mA to 500 mA, P < 2W • -4.85 Line Regulation (Note 1) (Note 4) VRLINE VIN = -7.5V to -20V 12 mV mV mV mV mV mV mA mA mA • VIN = -8.0V to -12V 25 5 • Load Regulation (Note 1) Standby Current Drain ISCD ∆ISCD (Line) ∆ISCD (Load) VDO IO (pk) IDS ∆VIN ∆VOUT Output Noise Voltage (Note 3) Long Term Stability (Note 3) ∆VOUT ∆t TA = 25°C, t = 1000 hrs. NO ∆VOUT = 100mV, IO = 500 mA TA = 25°C VIN = -35V IO = 5mA to 500 mA VIN = -7.0V to -20V VRLOAD IO = 5mA to 500 mA 12 25 • • • • • 0.5 50 2.5 3.0 0.4 Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection 0.4 mA 2.5 1.7 .7 V A A A dB dB • f =120 Hz, ∆VIN = -10V (Note 3) TA = 25°C, f =10 Hz to 100KHz 63 2.0 • 60 40 µV/V RMS 75 mV 3.5 Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = -35V. 3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5.0 mA. 3.5 - 50 OM1905N2M - OM1915N2M ELECTRICAL CHARACTERISTICS -12 Volt Parameter Output Voltage Symbol VOUT VIN = -19V, Io = 100 mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified) Min. -11.88 Max. -12.12 -12.36 Unit V V Test Conditions TA = 25°C VIN = -14.5V to -27V IO = 5mA to 500 mA, PD < 2 W • -11.64 Line Regulation (Note 1) (Note 4) VRLINE VIN = -14.5V to -27V 20 mV mV mV mV mV mV mA mA mA • VIN = -16V to -22V 50 10 • Load Regulation (Note 1) Standby Current Drain ISCD ∆ISCD (Line) ∆ISCD (Load) VDO IO (pk) IDS ∆VIN ∆VOUT Output Noise Voltage (Note 3) Long Term Stability (Note 3) ∆VOUT ∆t TA = 25°C, t = 1000 hrs. NO ∆VOUT = 100mV, IO = 500 mA TA = 25°C, IO = 5 mA to 1A VIN = -35V IO = 5mA to 500 mA VIN = -14.5V to -27V VRLOAD IO = 5 mA to 500 mA 30 32 • • • • • 0.5 60 3.5 4.0 0.8 Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection 0.5 mA 1.8 1.7 .7 V A A A dB dB • f =120 Hz, ∆VIN = -10V (Note 3) TA = 25°C, f =10 Hz to 100 KHz 56 2.0 • 53 40 µV/V RMS 120 mV Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = -35V. 3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5.0 mA. PIN CONNECTION Terminal Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 NC VINput NC VOUTput VOUTput NC VOUTput NC NC NC NC NC NC NC Ground NC Ground NC NC VINput .003 MECHANICAL OUTLINE .009 R. 20 PLCS. .020 X45° REF. (±.003) .065 .040 4 .010 .075 (±.010) TYP. 9 3.5 .025 TYP. .085 3 1 19 .160 SQ. REF. 13 18 14 Note: The input pins (2 and 20) are to be connected together, the output pins (4,5, and 7) are to be connected together and the ground pins (15 and 17) are to be connected together for operation. .025 SQ. TYP. .050 (±.005) TYP. .050 TYP. .040 X45° REF (3 PL) 3.5 - 51 OM1905N2M - OM1915N2M ELECTRICAL CHARACTERISTICS -15 Volt Parameter Output Voltage Symbol VOUT VIN = -23V, Io = 100mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified) Min. -14.85 Max. -15.15 -15.45 Unit V V Test Conditions TA = 25°C VIN = -17.5V to -30V IO = 5 mA to 500 m A, PD < 2 W • -14.55 Line Regulation (Note 1) (Note 4) VRLINE VIN = -17.5V to -30V 25 mV mV mV mV mV mV mA mA mA • VIN = -20V to -26V 50 15 • Load Regulation (Note 1) Standby Current Drain ISCD ∆ISCD (Line) ∆ISCD (Load) VDO IO (pk) IDS ∆VIN ∆VOUT Output Noise Voltage (Note 3) Long Term Stability (Note 3) ∆VOUT ∆t TA = 25°C, t = 1000 hrs. NO ∆VOUT = 100mV, IO = 500 mA TA = 25°C VIN = -35V IO = 5mA to 500 mA VIN = -17.5V to -30V VRLOAD IO = 5mA to 500 mA 25 50 • • • • • 0.5 90 6.0 6.5 0.8 Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection 0.5 mA 2.5 1.7 0.7 V A A A dB dB • f =120 Hz, ∆VIN = -10V (Note 3) TA = 25°C, f =10 Hz to 100KHz 53 2.0 • 50 40 µV/V RMS 150 mV Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = -35V. 3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5.0 mA. 3.5
OM1915N2M 价格&库存

很抱歉,暂时无法提供与“OM1915N2M”相匹配的价格&库存,您可以联系我们找货

免费人工找货