ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
DESCRIPTION
The 6N137, ICPL2601 and ICPL2611 devices each
consist of an infrared emitting diode, optically coupled
to a high speed integrated photo detector logic gate
with a strobable output.
1
2
3
4
5
6
7
8
FEATURES
•
•
•
•
•
•
•
•
High Speed 10Mbit/s
Minimum Common Mode Transient Immunity
10kV/μs for ICPL2611
High AC Isolation Voltage 5000VRMS
Guaranteed Performance from -40°C to 85°C
Logic Gate Output
Pb Free and RoHS Compliant
UL File E91231 for ICPL2601
VDE File 40044276 marked as 6N137V
APPLICATIONS
•
•
•
•
•
•
•
Line Receivers, Data Communication
LSTTL to TTL, LSTTL or 5V CMOS
Data Multiplexing
Pulse Transformer Replacement
Switch Mode Power Supplies
Ground Loop Elimination
Computer Peripheral Interface
ORDER INFORMATION
•
•
•
Add G after PN for 10mm lead spacing
Add SM after PN for Surface Mount
Add SMT&R after PN for Surface Mount
Tape & Reel
NC
Anode
Cathode
NC
GND
VO
VE
VCC
A 0.1μF bypass Capacitor must be connected between Pins 8 and 5.
ABSOLUTE MAXIMUM RATINGS (TA = 25°C)
Stresses exceeding the absolute maximum ratings can cause
permanent damage to the device.
Exposure to absolute maximum ratings for long periods of time
can adversely affect reliability.
Input
Forward Current
Reverse Voltage
Power dissipation
50mA
5V
100mW
Output
Output Current
Output Voltage
Supply Voltage
Enable Input Voltage
50mA
7.0V
7.0V
5.5V
(maximum 500mV above VCC)
Power Dissipation
85mW
Total Package
Isolation Voltage
Operating Temperature
Storage Temperature
Lead Soldering Temperature
5000VRMS
-40 to 85 °C
-55 to 125 °C
260°C
(10s)
ISOCOM COMPONENTS 2004 LTD
Unit 25B, Park View Road West, Park View Industrial Estate
Hartlepool, Cleveland, TS25 1PE, United Kingdom
Tel : +44 (0)1429 863 609 Fax : +44 (0)1429 863 581
e-mail : sales@isocom.co.uk
http://www.isocom.com
1 28/09/2017
ISOCOM COMPONENTS ASIA LTD
Hong Kong Office,
Block A, 8/F, Wah Hing Industrial mansion,
36 Tai Yau Street, San Po Kong, Kowloon, Hong Kong.
Tel : +852 2995 9217 Fax : +852 8161 6292
e-mail : sales@isocom.com.hk
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
Truth Table
Input
Enable
Output
H
H
L
L
H
H
H
L
H
L
L
H
H
NC
L
L
NC
H
Recommended Operating Conditions
Parameter
Symbol
Min
Max
Unit
Operating Temperature
TA
- 40
85
°C
Supply Voltage
VCC
4.5
5.5
V
Input Current, High Level
IF(ON)
5
10
mA
Input Current, Low Level
IF(OFF)
0
250
µA
Enable Voltage, High Level
VEH
2.0
VCC
V
Enable Voltage, Low Level
VEL
0
0.8
V
2 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
ELECTRICAL CHARACTERISTICS (TA = -40 to 85°C unless otherwise specified)
INPUT
Parameter
Typ.*
Max
Unit
IF = 10mA
1.4
1.8
V
ΔVF/ΔT
IF = 10mA
̶ 1.8
Reverse Voltage
VR
IR = 10μA
Input Capacitance
CIN
VF = 0V, f = 1MHz
Symbol
Test Condition
High Level
Supply Current
ICCH
Low Level
Supply Current
Forward Voltage
Forward Voltage
Temperature Coefficient
Symbol
Test Condition
VF
Min
mV/°C
5.0
V
60
pF
OUTPUT
Parameter
Min
Typ.*
Max
Unit
IF = 0mA, VCC = 5.5V
VE = 0.5V
7
10
mA
ICCL
IF = 10mA, VCC = 5.5V
9
13
mA
High Level
Output Current
IOH
IF = 250µA, VCC = 5.5V,
VE = 2.0V, VO = 5.5V
2.1
100
µA
Low Level
Output Voltage
VOL
IF = 5mA, VCC = 5.5V,
VE = 2.0V, IOL = 13mA
0.35
0.6
V
High Level
Enable Current
IEH
VCC = 5.5V, VE = 2.0V
-0.6
-1.6
mA
Low Level
Enable Current
IEL
VCC = 5.5V, VE = 0.5V
-0.8
-1.6
mA
High Level
Enable Voltage
VEH
IF = 10mA, VCC = 5.5V
Low Level
Enable Voltage
VEL
IF = 10mA, VCC = 5.5V
Parameter
Symbol
Test Condition
Input Threshold Current
IFT
VCC = 5.5V, VO = 0.6V
VE = 2.0V, IOL = 13mA
2.0
V
0.8
V
Typ.*
Max
Unit
2.5
5
mA
COUPLED
Min
* Typical values at TA = 25°C
3 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
ELECTRICAL CHARACTERISTICS (TA = -40 to 85°C unless otherwise specified)
SWITCHING (IF = 7.5mA, VCC = 5V unless otherwise specified)
Parameter
Symbol
Test Condition
Propagation Delay Time
to High Output Level
tPLH
Propagation Delay Time
to Low Output Level
tPHL
RL = 350Ω,
CL = 15pF,
TA = 25ºC
Pulse Width Distortion
|tPHL - tPLH|
RL = 350Ω,
CL = 15pF
Min
Typ.*
Max
Unit
35
75
ns
40
75
5
35
Output Rise Time
(10% to 90%)
tr
40
Output Fall Time
(90% to 10%)
tf
10
Enable Propagation
Delay Time to
High Output Level
tELH
Enable Propagation
Delay Time to
Low Output Level
tEHL
VEH = 3.5V,
RL = 350Ω,
CL = 15pF
15
15
* Typical values at TA = 25°C
4 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
ELECTRICAL CHARACTERISTICS (TA = -40 to 85°C unless otherwise specified)
SWITCHING (IF = 7.5mA, VCC = 5V unless otherwise specified)
Parameter
Common Mode
Transient Immunity at
Logic High
Symbol
CMH
Test Condition
Min
6N137
Typ.*
Max
Unit
5000
V/μs
5000
V/μs
IF = 0mA, VOH = 2.0V,
RL = 350Ω, VCM = 10Vp-p,
TA = 25°C
ICPL2601
5000
IF = 0mA, VOH = 2.0V,
RL = 350Ω, VCM = 50Vp-p,
TA = 25°C
ICPL2611
10000
IF = 0mA, VOH = 2.0V,
RL = 350Ω, VCM = 400Vp-p,
TA = 25°C
ICPL2611
20000
High CMR Test Circuit
IF = 0mA, VOH = 2.0V,
RL = 350Ω, VCM = 400Vp-p,
TA = 25°C
Common Mode
Transient Immunity at
Logic Low
CML
6N137
IF = 7.5mA, VOL = 0.8V,
RL = 350Ω, VCM = 10Vp-p,
TA = 25°C
ICPL2601
5000
IF = 7.5mA, VOL = 0.8V,
RL = 350Ω, VCM = 50Vp-p,
TA = 25°C
ICPL2611
10000
IF = 7.5mA, VOL = 0.8V,
RL = 350Ω, VCM = 400Vp-p,
TA = 25°C
ICPL2611
20000
High CMR Test Circuit
IF = 7.5mA, VOL = 0.8V,
RL = 350Ω, VCM = 400Vp-p,
TA = 25°C
* Typical values at TA = 25°C
5 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
ELECTRICAL CHARACTERISTICS (TA = -40 to 85°C unless otherwise specified)
ISOLATION
Parameter
Insulation Voltage
Symbol
Test Condition
Min
VISO
RH = 40% - 60%, TA = 25°C
t = 1 min,
5000
Typ.*
Max
Unit
VRMS
* Typical values at TA = 25°C
Note :
- VCC supply must be bypassed by a 0.1μF capacitor or larger with good high frequency characteristic and
should be connected as close as possible to the package VCC and GND pins.
- Enable Input – No pull up resistor required as the device has an internal pull up resistor.
- tPLH is measured from the 3.75mA level on the HIGH to LOW transition of the input current pulse to the 1.5 V
level on the LOW to HIGH transition of the output voltage pulse.
- tPHL is measured from the 3.75mA level on the LOW to HIGH transition of the input current pulse to the 1.5 V
level on the HIGH to LOW transition of the output voltage pulse.
- tr Rise time is measured from the 10% to the 90% levels on the LOW to HIGH transition of the output pulse.
- tf Fall time is measured from the 90% to the 10% levels on the HIGH to LOW transition of the output pulse.
- tELH is measured from the 1.5V level on the HIGH to LOW transition of the input Enable voltage pulse to the
1.5V level on the LOW to HIGH transition of the output voltage pulse.
- tEHL is measured from the 1.5V level on the LOW to HIGH transition of the input Enable voltage pulse to the
1.5V level on the HIGH to LOW transition of the output voltage pulse.
- CMH – The maximum tolerable rate of rise of the Common Mode voltage to ensure the output will remain in the
HIGH state (i.e., VO > 2.0V).
- CML – The maximum tolerable rate of rise of the Common Mode voltage to ensure the output will remain in the
LOW output state (i.e., VO < 0.8V).
6 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
Fig 1 Forward Current vs Forward Voltage
Fig 2 Input Threshold Current vs TA
Fig 3 Output Voltage vs Forward Current
Fig 4 Output Low Level Voltage vs TA
Fig 5 Output High Level Current vs TA
Fig 6 Output Low Level Current vs TA
7 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
Fig 7 Propagation Delay vs Forward Current
Fig 9 Rise / Fall Time vs TA
Fig 8 Propagation Delay vs TA
Fig 10 Pulse Width Distortation vs TA
Fig 11 Enable Propagation Delay vs TA
8 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
tr, tf, tPLH and tPHL Test Circuit
CMR Test Circuit
9 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
VCM
0V
5V
VO
Pos. A, IF = 0mA
CMH
VO(Min)
VO(Max)
VO
Pos. B, IF = 7.5mA
CML
0.5V
CMR Test Circuit
High CMR Test Circuit for ICPL2611
10 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
ORDER INFORMATION
UL Approval
PN
After PN
Description
Packing quantity
None
ICPL2601
Standard DIP8
45 pcs per tube
G
ICPL2601G
10mm Lead Spacing
45 pcs per tube
SM
ICPL2601SM
Surface Mount
45 pcs per tube
SMT&R
ICPL2601SMT&R
Surface Mount Tape & Reel
1000 pcs per reel
UL and VDE Approvals
PN
After PN
Description
Packing quantity
None
6N137
Standard DIP8
45 pcs per tube
G
6N137G
10mm Lead Spacing
45 pcs per tube
SM
6N137SM
Surface Mount
45 pcs per tube
SMT&R
6N137SMT&R
Surface Mount Tape & Reel
1000 pcs per reel
Safety Approval Pending
PN
After PN
Description
Packing quantity
None
ICPL2611
Standard DIP8
45 pcs per tube
G
ICPL2611G
10mm Lead Spacing
45 pcs per tube
SM
ICPL2611SM
Surface Mount
45 pcs per tube
SMT&R
ICPL2611SMT&R
Surface Mount Tape & Reel
1000 pcs per reel
11 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
DEVICE MARKING
Example : 6N137
6N137V
IYWW
6N137V
denotes Device Part Number
I
denotes Isocom
Y
denotes 1 digit Year code
WW
denotes 2 digit Week code
12 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
PACKAGE DIMENSIONS (mm)
DIP
G-Form
13 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
PACKAGE DIMENSIONS (mm)
SMD
RECOMMENDED PAD LAYOUT FOR SMD (mm)
14 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
TAPE AND REEL PACKAGING
Direction of feed from reel
Dimension No.
A
B
D0
D1
E
F
Dimension( mm)
10.4±0.1
10.0±0.1
1.5±0.1
1.5±0.1
1.75±0.1
7.5±0.1
Dimension No.
P0
P1
P2
t
W
K
Dimension (mm)
4.0±0.1
12.0±0.1
2.0±0.1
0.4±0.1
16.0
±0.3 / -0.1
4.5±0.1
15 28/09/2017
DD93209
ISOCOM
COMPONENTS
6N137, ICPL2601, ICPL2611
IR REFLOW SOLDERING TEMPERATURE PROFILE
One Time Reflow Soldering is Recommended.
Do not immerse device body in solder paste.
TP
260°C
TP - 5°C
Max Ramp Up Rate
3°C/s
TEMP (°C)
TL
Tsmax
Tsmin
tP
Max Ramp Down Rate
6°C/s
217°C
TL
200°C
150°C
ts Preheat
60s – 120s
25°C
TIME (s)
Time 25°C to Peak Temperature
Profile Details
Conditions
Preheat
- Min Temperature (TSMIN)
- Max Temperature (TSMAX)
- Time TSMIN to TSMAX (ts)
150°C
200°C
60s - 120s
Soldering Zone
- Peak Temperature (TP)
- Time at Peak Temperature
- Liquidous Temperature (TL)
- Time within 5°C of Actual Peak Temperature (TP ̶ 5°C)
- Time maintained above TL (tL)
- Ramp Up Rate (TL to TP)
- Ramp Down Rate (TP to TL)
260°C
10s max
217°C
30s max
60s - 100s
3°C/s max
6°C/s max
Average Ramp Up Rate (Tsmax to TP)
3°C/s max
Time 25°C to Peak Temperature
8 minutes max
16 28/09/2017
DD93209
ISOCOM
COMPONENTS
DISCLAIMER
Isocom Components is continually working to improve the quality and reliability of its products.
Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent
electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer,
when utilizing Isocom Components products, to comply with the standards of safety in making
a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such Isocom Components products could cause loss of human life, bodily injury or damage to
property.
In developing your designs, please ensure that Isocom Components products are used within
specified operating ranges as set forth in the most recent Isocom Components products
specifications.
The Isocom Components products listed in this document are intended for usage in general
electronics applications (computer, personal equipment, office equipment, measuring
equipment, industrial robotics, domestic appliances, etc.). These Isocom Components
products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss
of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy
control instruments, airplane or spaceship instruments, transportation Instruments, traffic
signal instruments, combustion control instruments, medical Instruments, all types of safety
devices, etc... Unintended Usage of Isocom Components products listed in this document
shall be made at the customer’s own risk.
Gallium arsenide (GaAs) is a substance used in the products described in this document.
GaAs dust and fumes are toxic. Do not break, cut or pulverize the product, or use chemicals to
dissolve them. When disposing of the products, follow the appropriate regulations. Do not
dispose of the products with other industrial waste or with domestic garbage.
The products described in this document are subject to the foreign exchange and foreign trade
laws.
The information contained herein is presented only as a guide for the applications of our
products. No responsibility is assumed by Isocom Components for any infringements of
intellectual property or other rights of the third parties which may result from its use. No license
is granted by implication or otherwise under any intellectual property or other rights of Isocom
Components or others.
The information contained herein is subject to change without notice.
17 28/09/2017
DD93209