IS31FL3236A-QFLS2-TR 数据手册
IS31FL3236A
36 CHANNEL LED DRIVER; SELECTABLE PWM FREQUENCY
November 2016
GENERAL DESCRIPTION
FEATURES
IS31FL3236A is comprised of 36 constant current
channels each with independent PWM control,
designed for driving LEDs, PWM frequency can be
3kHz or 22kHz. The output current of each channel
can be set at up to 38mA (Max.) by an external resistor
and independently scaled by a factor of 1, 1/2, 1/3 and
1/4. The average LED current of each channel can be
changed in 256 steps by changing the PWM duty cycle
through an I2C interface.
•
•
The chip can be turned off by pulling the SDB pin low or
by using the software shutdown feature to reduce
power consumption.
•
IS31FL3236A is available in QFN-44 (5mm × 5mm)
package. It operates from 2.7V to 5.5V over the
temperature range of -40°C to +85°C.
•
•
•
•
•
•
•
2.7V to 5.5V supply
I2C interface, automatic address increment
function
Four selectable I2C addresses
Internal reset register
Modulate LED brightness with 256 steps PWM
Each channel can be controlled independently
Each channel can be scaled independently by 1,
1/2, 1/3 and 1/4
PWM frequency selectable
- 3kHz (default)
- 22kHz
-40°C to +85°C temperature range
QFN-44 (5mm × 5mm) package
APPLICATIONS
•
•
Mobile phones and other hand-held devices for
LED display
LED in home appliances
TYPICAL APPLICATION CIRCUIT
Figure 1
Typical Application Circuit
Note 1: The maximum global output current is set to 23mA when REXT = 3.3kΩ. Please refer Page 10 for setting LED current.
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
1
IS31FL3236A
PIN CONFIGURATION
Package
Pin Configuration (Top View)
QFN-44
PIN DESCRIPTION
No.
Pin
Description
1~3
OUT3 ~ OUT5
Output channel 3~5 for LEDs.
4~16
OUT6 ~ OUT18
Output channel 6~18 for LEDs.
17,39
GND
Ground.
18~30
OUT19 ~ OUT31
Output channel 19~31 for LEDs.
31~35
OUT32 ~ OUT36
Output channel 32~36 for LEDs.
36
SDB
Shutdown the chip when pulled low.
37
AD
I2C address setting.
38
VCC
Power supply.
40
R_EXT
Input terminal used to connect an external resistor.
This regulates the global output current.
41
SDA
I2C serial data.
42
SCL
I2C serial clock.
43,44
OUT1, OUT2
Output channel 1, 2 for LEDs.
Thermal Pad
Connect to GND.
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
2
IS31FL3236A
ORDERING INFORMATION
Industrial Range: -40°C to +85°C
Order Part No.
Package
QTY/Reel
IS31FL3236A-QFLS2-TR
QFN-44, Lead-free
2500
Copyright © 2016 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any
time without notice. ISSI assumes no liability arising out of the application or use of any information, products or services described herein. Customers are
advised to obtain the latest version of this device specification before relying on any published information and before placing orders for products.
Integrated Silicon Solution, Inc. does not recommend the use of any of its products in life support applications where the failure or malfunction of the
product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not
authorized for use in such applications unless Integrated Silicon Solution, Inc. receives written assurance to its satisfaction, that:
a.) the risk of injury or damage has been minimized;
b.) the user assume all such risks; and
c.) potential liability of Integrated Silicon Solution, Inc is adequately protected under the circumstances
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
3
IS31FL3236A
ABSOLUTE MAXIMUM RATINGS
Supply voltage, VCC
Voltage at SCL, SDA, SDB, OUT1 to OUT36
Maximum junction temperature, TJMAX
Storage temperature range, TSTG
Operating temperature range, TA=TJ
Package thermal resistance (Mounted on JEDEC standard 4
layer(2s2p) PCB test board), θJA
ESD (HBM)
ESD (CDM)
-0.3V ~ +6.0V
-0.3V ~ VCC+0.3V
160°C
-65°C ~ +150°C
-40°C ~ +85°C
32.65°C/W
±8kV
±1kV
Note:
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other condition beyond those indicated in the operational sections of the specifications is not
implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
Typical values are TA = 25°C, VCC = 3.6V.
Symbol
Parameter
Condition
Min.
Typ.
Unit
5.5
V
VCC
Supply voltage
IMAX
Maximum global output
current
VCC= 4.2V, VOUT= 0.8V
REXT= 2kΩ, SL= “00” (Note 1)
38
mA
IOUT
Output current
VOUT= 0.6V, REXT= 3.3kΩ,
SL= “00”
23
mA
VHR
Headroom voltage
REXT= 3.3kΩ, IOUT= 20mA
0.4
ICC
Quiescent power supply
current
REXT= 3.3kΩ
9
ISD
Shutdown current
VSDB= 0V or software shutdown
TA= 25°C, VCC= 3.6V
3
fOUT
PWM frequency of output
IOZ
Output leakage current
VSDB= 0V or software shutdown,
VOUT= 5.5V
Thermal shutdown
(Note 2)
160
°C
(Note 2)
20
°C
1.3
V
TSHDN
TSHDNHYST Hysteresis
VEXT
2.7
Max.
0.6
V
mA
5
μA
0x4B= 0x00
2.9
kHz
0x4B= 0x01
21.6
kHz
0.2
Output voltage of R-EXT pin
μA
Logic Electrical Characteristics (SDA, SCL, SDB)
VIL
Logic “0” input voltage
VCC= 2.7V
VIH
Logic “1” input voltage
VCC= 5.5V
IIL
Logic “0” input current
VINPUT= 0V (Note 2)
5
nA
IIH
Logic “1” input current
VINPUT= VCC (Note 2)
5
nA
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
0.4
1.4
V
V
4
IS31FL3236A
DIGITAL INPUT SWITCHING CHARACTERISTICS (NOTE 2)
Symbol
Parameter
Condition
Min.
Typ.
Max.
Unit
400
kHz
fSCL
Serial-Clock frequency
tBUF
Bus free time between a STOP and a START
condition
1.3
μs
tHD, STA
Hold time (repeated) START condition
0.6
μs
tSU, STA
Repeated START condition setup time
0.6
μs
tSU, STO
STOP condition setup time
0.6
μs
tHD, DAT
Data hold time
tSU, DAT
Data setup time
100
ns
tLOW
SCL clock low period
1.3
μs
tHIGH
SCL clock high period
0.7
μs
0.9
μs
tR
Rise time of both SDA and SCL signals,
receiving
(Note 3)
20+0.1Cb
300
ns
tF
Fall time of both SDA and SCL signals,
receiving
(Note 3)
20+0.1Cb
300
ns
Note 1: The recommended minimum value of REXT is 2kΩ, or it may cause a large current.
Note 2: Guaranteed by design.
Note 3: Cb = total capacitance of one bus line in pF. ISINK ≤ 6mA. tR and tF measured between 0.3 × VCC and 0.7 × VCC.
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
5
IS31FL3236A
DETAILED DESCRIPTION
I2C INTERFACE
The IS31FL3236A uses a serial bus, which conforms to
the I2C protocol, to control the chip’s functions with two
wires: SCL and SDA. The IS31FL3236A has a 7-bit
slave address (A7:A1), followed by the R/W bit, A0.
Since IS31FL3236A only supports write operations, A0
must always be “0”. The value of bits A1 and A2 are
decided by the connection of the AD pin.
The complete slave address is:
Table 1 Slave Address (Write only):
Bit
A7:A3
A2:A1
A0
Value
01111
AD
0
After the last bit of the chip address is sent, the master
checks for the IS31FL3236A’s acknowledge. The
master releases the SDA line high (through a pull-up
resistor). Then the master sends an SCL pulse. If the
IS31FL3236A has received the address correctly, then
it holds the SDA line low during the SCL pulse. If the
SDA line is not low, then the master should send a
“STOP” signal (discussed later) and abort the transfer.
Following acknowledge of IS31FL3236A, the register
address byte is sent, most significant bit first.
IS31FL3236A must generate another acknowledge
indicating that the register address has been received.
AD connected to GND, AD = 00;
AD connected to VCC, AD = 11;
AD connected to SCL, AD = 01;
AD connected to SDA, AD = 10;
The SCL line is uni-directional. The SDA line is
bi-directional (open-collector) with a pull-up resistor
(typically 4.7kΩ). The maximum clock frequency
specified by the I2C standard is 400kHz. In this
discussion, the master is the microcontroller and the
slave is the IS31FL3236A.
The timing diagram for the I2C is shown in Figure 2.
The SDA is latched in on the stable high level of the
SCL. When there is no interface activity, the SDA line
should be held high.
The “START” signal is generated by lowering the SDA
signal while the SCL signal is high. The start signal will
alert all devices attached to the I2C bus to check the
incoming address against their own chip address.
Figure 2
Figure 3
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
The 8-bit chip address is sent next, most significant bit
first. Each address bit must be stable while the SCL
level is high.
Then 8-bit of data byte are sent next, most significant
bit first. Each data bit should be valid while the SCL
level is stable high. After the data byte is sent, the
IS31FL3236A must generate another acknowledge to
indicate that the data was received.
The “STOP” signal ends the transfer. To signal “STOP”,
the SDA signal goes high while the SCL signal is high.
ADDRESS AUTO INCREMENT
To write multiple bytes of data into IS31FL3236A, load
the address of the data register that the first data byte
is intended for. During the IS31FL3236A acknowledge
of receiving the data byte, the internal address pointer
will increment by one. The next data byte sent to
IS31FL3236A will be placed in the new address, and
so on. The auto increment of the address will continue
as long as data continues to be written to IS31FL3236A
(Figure 5).
Interface Timing
Bit Transfer
6
IS31FL3236A
Figure 4
Figure 5
Writing to IS31FL3236A (Typical)
Writing to IS31FL3236A (Automatic Address Increment)
REGISTERS DEFINITIONS
Table 2 Register Function
Address
00h
Name
Function
Table
Default
Shutdown Register
Set software shutdown mode
3
PWM Register
36 channels PWM duty cycle data register
4
25h
PWM Update Register
Load PWM Register and LED Control Register’s
data
-
26h~49h
LED Control Register
Channel 1 to 36 enable bit and current setting
5
4Ah
Global Control Register
Set all channels enable
6
4Bh
Output Frequency
Setting Register
Set all channels operating frequency
7
0000 0000
4Fh
Reset Register
Reset all registers into default value
-
xxxx xxxx
01h~24h
xxxx xxxx
0000 0000
Table 4 01h~24h PWM Register (OUT1~OUT36)
Table 3 00h Shutdown Register
Bit
D7:D1
D0
Bit
D7:D0
Name
-
SSD
Name
PWM
Default
0000000
0
Default
0000 0000
The Shutdown Register sets software shutdown mode
of IS31FL3236A.
SSD
0
1
0000 0000
Software Shutdown Enable
Software shutdown mode
Normal operation
The PWM Registers adjusts LED luminous intensity in
256 steps.
The value of a channel’s PWM Register decides the
average output current for each output, OUT1~OUT36.
The average output current may be computed using
the Formula (1):
(1)
Where “n” indicates the bit location in the respective
PWM register.
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
7
IS31FL3236A
For example: D7:D0 = 10110101,
IOUT = IMAX (20+22+24+25+27)/256
The IOUT of each channel is setting by the SL bit of LED
Control Register (26h~49h). Please refer to the detail
information in Page 11.
25h PWM Update Register
The data sent to the PWM Registers and the LED
Control Registers will be stored in temporary registers.
A write operation of “0000 0000” value to the Update
Register is required to update the registers (01h~24h,
26h~49h).
Table 6 4Ah Global Control Register
Bit
D7:D1
D0
Name
-
G_EN
Default
0000000
0
The Global Control Register set all channels enable.
G_EN
0
1
Global LED Enable
Normal operation
Shutdown all LEDs
Table 7 4Bh Output Frequency Setting Register
Table 5 26h~49h LED Control Register
(OUT1~OUT36)
Bit
D7:D1
D0
Bit
D7:D3
D2:D1
D0
Name
-
OFS
Name
-
SL
OUT
Default
0000000
0
Default
00000
00
0
The LED Control Registers store the on or off state of
each LED and set the output current.
SL
00
01
10
11
Output Current Setting (IOUT)
IMAX
IMAX/2
IMAX/3
IMAX/4
OUT
0
1
LED State
LED off
LED on
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
The Output Frequency Setting Register selects a fixed
PWM operating frequency for all output channels.
OFS
0
1
Output Frequency Setting
3kHz
22kHz
4Fh Reset Register
Once user writes “0000 0000” data to the Reset
Register, IS31FL3236A will reset all registers to default
value. On initial power-up, the IS31FL3236A registers
are reset to their default values for a blank display.
8
IS31FL3236A
FUNCTIONAL BLOCK DIAGRAM
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
9
IS31FL3236A
TYPICAL APPLICATION
PWM CONTROL
Table 8 32 Gamma Steps With 256 PWM Steps
The PWM Registers (01h~24h) can modulate LED
brightness of 36 channels with 256 steps. For example,
if the data in PWM Register is “0000 0100”, then the
PWM is the fourth step.
C(0)
C(1)
C(2)
C(3)
C(4)
C(5)
C(6)
C(7)
0
1
2
4
6
10
13
18
C(8)
C(9)
C(10)
C(11)
C(12)
C(13)
C(14)
C(15)
22
28
33
39
46
53
61
69
Writing new data continuously to the registers can
modulate the brightness of the LEDs to achieve a
breathing effect.
C(16)
C(17)
C(18)
C(19)
C(20)
C(21)
C(22)
C(23)
78
86
96
106
116
126
138
149
C(24)
C(25)
C(26)
C(27)
C(28)
C(29)
C(30)
C(31)
161
173
186
199
212
226
240
255
REXT
The maximum output current of OUT1~OUT36 can be
adjusted by the external resistor, REXT, as described in
Formula (2).
(2)
x = 58.5, VOUT = 0.8V, VEXT = 1.3V.
The recommended minimum value of REXT is 2kΩ.
CURRENT SETTING
The current of each LED can be set independently by
the SL bit of LED Control Register (26h~49h). The
maximum global current is set by the external register
REXT.
When channels drive different quantity of LEDs, adjust
maximum output current according to quantity of LEDs
to ensure average current of each LED is the same.
For example, set REXT = 3.3kΩ then IMAX = 23mA. If
OUT1 drives two LEDs and OUT2 drives four LEDs, set
the SL bit of LED Control Register (26h) to “01” and SL
bit of LED Control Register (27h) to “00”. So the current
of OUT1 is IOUT1 = IMAX/2 = 11.5mA and the current of
OUT2 is IOUT2 = IMAX = 23mA. The average current of
each LED is the same.
GAMMA CORRECTION
In order to perform a better visual LED breathing effect
we recommend using a gamma corrected PWM value
to set the LED intensity. This results in a reduced
number of steps for the LED intensity setting, but
causes the change in intensity to appear more linear to
the human eye.
Gamma correction, also known as gamma
compression or encoding, is used to encode linear
luminance to match the non-linear characteristics of
display. Since the IS31FL3236A can modulate the
brightness of the LEDs with 256 steps, a gamma
correction function can be applied when computing
each subsequent LED intensity setting such that the
changes in brightness matches the human eye's
brightness curve.
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
Figure 6
Gamma Correction (32 Steps)
Choosing more gamma steps provides for a more
continuous looking breathing effect. This is useful for
very long breathing cycles. The recommended
configuration is defined by the breath cycle T. When
T=1s, choose 32 gamma steps, when T=2s, choose
64 gamma steps. The user must decide the final
number of gamma steps not only by the LED itself, but
also based on the visual performance of the finished
product.
64 Gamma Steps With 256 PWM Steps
Table 9
C(0)
C(1)
C(2)
C(3)
C(4)
C(5)
C(6)
C(7)
0
1
2
3
4
5
6
7
C(8)
C(9)
C(10)
C(11)
C(12)
C(13)
C(14)
C(15)
8
10
12
14
16
18
20
22
C(16)
C(17)
C(18)
C(19)
C(20)
C(21)
C(22)
C(23)
24
26
29
32
35
38
41
44
C(24)
C(25)
C(26)
C(27)
C(28)
C(29)
C(30)
C(31)
47
50
53
57
61
65
69
73
C(32)
C(33)
C(34)
C(35)
C(36)
C(37)
C(38)
C(39)
77
81
85
89
94
99
104
109
C(40)
C(41)
C(42)
C(43)
C(44)
C(45)
C(46)
C(47)
114
119
124
129
134
140
146
152
C(48)
C(49)
C(50)
C(51)
C(52)
C(53)
C(54)
C(55)
158
164
170
176
182
188
195
202
C(56)
C(57)
C(58)
C(59)
C(60)
C(61)
C(62)
C(63)
209
216
223
230
237
244
251
255
10
IS31FL3236A
experience large instantaneous current surges when
the OUTx channels turn ON. These current surges will
generate an AC ripple on the power supply which
cause stress to the decoupling capacitors.
When the AC ripple is applied to a monolithic ceramic
capacitor chip (MLCC) it will expand and contract
causing the PCB to flex and generate audible hum in
the range of between 20Hz to 20kHz, To avoid this
hum, there are many countermeasures, such as
selecting the capacitor type and value which will not
cause the PCB to flex and contract.
Figure 7
Gamma Correction (64 Steps)
Note, the data of 32 gamma steps is the standard value and the data
of 64 gamma steps is the recommended value.
SHUTDOWN MODE
An additional option for avoiding audible hum is to set
the IS31FL3236’s output PWM frequency above the
audible range. The Output Frequency Setting Register
4Bh bit D0 can be used to set the switching frequency
to 22kHz, which is beyond the audible range. Figure 8
below shows the variation of output PWM frequency
across supply voltage and temperature.
Shutdown mode can be used as a means of reducing
power consumption. During shutdown mode all
registers retain their data.
SOFTWARE SHUTDOWN
By setting SSD bit of the Shutdown Register (00h) to “0”,
the IS31FL3236A will operate in software shutdown
mode. When the IS31FL3236A is in software shutdown
mode, all current sources are switched off.
HARDWARE SHUTDOWN
The chip enters hardware shutdown mode when the
SDB pin is pulled low.
PWM FREQUENCY SELECT
The IS31FL3236 output channels operate with a
default PWM frequency of 3kHz. Because all the OUTx
channels are synchronized, the DC supply will
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
Figure 8
VCC vs. OUTPUT PWM Frequency
11
IS31FL3236A
CLASSIFICATION REFLOW PROFILES
Profile Feature
Pb-Free Assembly
Preheat & Soak
Temperature min (Tsmin)
Temperature max (Tsmax)
Time (Tsmin to Tsmax) (ts)
150°C
200°C
60-120 seconds
Average ramp-up rate (Tsmax to Tp)
3°C/second max.
Liquidous temperature (TL)
Time at liquidous (tL)
217°C
60-150 seconds
Peak package body temperature (Tp)*
Max 260°C
Time (tp)** within 5°C of the specified
classification temperature (Tc)
Max 30 seconds
Average ramp-down rate (Tp to Tsmax)
6°C/second max.
Time 25°C to peak temperature
8 minutes max.
Figure 9
Classification Profile
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
12
IS31FL3236A
PACKAGE INFORMATION
QFN-44
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
13
IS31FL3236A
RECOMMENDED LAND PATTERN
QFN-44
Note:
1. Land pattern complies to IPC-7351.
2. All dimensions in MM.
3. This document (including dimensions, notes & specs) is a recommendation based on typical circuit board manufacturing parameters. Since
land pattern design depends on many factors unknown (eg. user’s board manufacturing specs), user must determine suitability for use.
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
14
IS31FL3236A
REVISION HISTORY
Revision
Detail Information
Date
0A
Initial release
2016.09.06
A
Release to mass product
2016.11.15
Integrated Silicon Solution, Inc. – www.issi.com
Rev. A, 11/15/2016
15