576Mb: x18, x36 RLDRAM 3
Features
RLDRAM 3
IS49RL18320– 2 Meg x 18 x 16 Banks
IS49RL36160– 1 Meg x 36 x 16 Banks
Features
• 1066 MHz DDR operation (2133 Mb/s/ball data
rate)
• 76.8 Gb/s peak bandwidth (x36 at 1066 MHz clock
frequency)
• Organization
– 32 Meg x 18, and 16 Meg x 36 common I/O (CIO)
– 16 banks
• 1.2V center-terminated push/pull I/O
• 2.5V V EXT , 1.35V V DD , 1.2V V DDQ I/O
• Reduced cycle time ( tRC (MIN) = 8 - 12ns)
• SDR addressing
• Programmable READ/WRITE latency (RL/WL) and
burst length
• Data mask for WRITE commands
•
• Fr
x,
DK x#) and output data clocks (QK x, QK x#)
• On-die DLL generates CK edge-aligned data and
•
•
•
•
•
•
•
•
64ms refresh (128K refresh per 64ms)
168-ball FBGA package
Ω or 60 Ω matched impedance outputs
Integrated on-die termination (ODT)
Single or multibank writes
Extended operating range (200–1066 MHz)
READ training register
Multiplexed and non-multiplexed addressing capabilities
• Mirror function
• Output driver and ODT calibration
• JTAG interface (IEEE 1149.1-2001)
Options
• Clock cycle and tRC timing
– 0.93ns and tRC (MIN) = 8ns
(RL3-2133)
– 0.93ns and tRC (MIN) = 10ns
(RL3-2133)
– 1.07ns and tRC (MIN) = 8ns
(RL3-1866)
– 1.07ns and tRC (MIN) = 10ns
(RL3-1866)
– 1.25ns and tRC (MIN) = 8ns
(RL3-1600)
– 1.25ns and tRC (MIN) = 10ns
(RL3-1600)
– 1.25ns and tRC (MIN) = 12ns
(RL3-1600)
•
Configuration
-32 Meg x 18
- 16 Meg x 36
•
Operating Temperature
– Commercial (TC = 0° to +95°C)
– Industrial (TC = –40°C to +95°C)
•
Package
– 168-ball FBGA
– 168-ball FBGA (Pb-free)
• Revision
Copyright © 2014 Integrated Silicon Solu on, Inc. All rights reserved. ISSI reserves the right to make changes to this specifica on and its products at any me without
no ce. ISSI assumes no liability arising out of the applica on or use of any informa on, products or services described herein. Customers are advised to obtain the
latest version of this device specifica on before relying on any published informa on and before placing orders for produs.ct
Integrated Silicon Solu on, Inc. does not recommend the use of any of its products in life support applica ons where the failure or malfunc on of the product can
reasonably be expected to cause failure of the life support system or to significantly affect its safety or effec veness. Products are not authorized for use in such
applica ons unless Integrated Silicon Solu on, Inc. receives wri en assurance to its sa sfac on, that:
a.) the risk of injury or damage has been minimized;
b.) the user assume all such risks; and
c.) poten al liability of Integrated Silicon Solu on, Inc is adequately protected under the circumstances
RLDRAM® is a registered trademark of Micron Technology, Inc.
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
1
576Mb: x18, x36 RLDRAM 3
Features
Figure 1: 576Mb RLDRAM
3 Part Numbers
Example Part Number: IS49RL18320-093EBL
IS49RL
Speed Package Temp
Configuration
Temperature
Configuration
32 Meg x 18
18320
16 Meg x 36
36160
Commercial
None
Industrial
Package
Speed Grade
-093E t CK = 0.93ns (8ns
-093
t CK = 0.93ns (10ns
-107E t CK = 1.07ns (8ns
-107
t CK = 1.07ns (10ns
-125F
t CK = 1.25ns (8ns
t RC)
B
168-ball FBGA (Pb-free)
BL
t RC)
t RC)
t RC)
t RC)
-125E t CK = 1.25ns (10ns
t RC)
t CK = 1.25ns (12ns
t RC)
-125
168-ball FBGA
BGA Part Marking Decoder
Due to space limitations, BGA-packaged components have an abbreviated part marking that is different from the
part number. ISSI’S BGA Part Marking Decoder is available on ISSI’S Web site at www.issi.com
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
2
576Mb: x18, x36 RLDRAM 3
Features
Contents
General Description ......................................................................................................................................... 8
General Notes .............................................................................................................................................. 8
State Diagram .................................................................................................................................................. 9
Functional Block Diagrams ............................................................................................................................. 10
Ball Assignments and Descriptions ................................................................................................................. 12
Package Dimensions ....................................................................................................................................... 16
Electrical Characteristics – IDD Specifications .................................................................................................. 17
Electrical Specifications – Absolute Ratings and I/O Capacitance ..................................................................... 21
Absolute Maximum Ratings ........................................................................................................................ 21
Input/Output Capacitance .......................................................................................................................... 21
AC and DC Operating Conditions .................................................................................................................... 22
AC Overshoot/Undershoot Specifications .................................................................................................... 24
Slew Rate Definitions for Single-Ended Input Signals ................................................................................... 27
Slew Rate Definitions for Differential Input Signals ...................................................................................... 29
ODT Characteristics ....................................................................................................................................... 30
ODT Resistors ............................................................................................................................................ 30
ODT Sensitivity .......................................................................................................................................... 32
Output Driver Impedance ............................................................................................................................... 33
Output Driver Sensitivity ............................................................................................................................ 35
Output Characteristics and Operating Conditions ............................................................................................ 36
Reference Output Load ............................................................................................................................... 39
Slew Rate Definitions for Single-Ended Output Signals ..................................................................................... 40
Slew Rate Definitions for Differential Output Signals ........................................................................................ 41
Speed Bin Tables ............................................................................................................................................ 42
AC Electrical Characteristics ........................................................................................................................... 44
Temperature and Thermal Impedance Characteristics ..................................................................................... 49
Command and Address Setup, Hold, and Derating ........................................................................................... 51
Data Setup, Hold, and Derating ....................................................................................................................... 57
Commands .................................................................................................................................................... 63
MODE REGISTER SET (MRS) Command ......................................................................................................... 64
Mode Register 0 (MR0) .................................................................................................................................... 65
tRC ............................................................................................................................................................. 66
Data Latency .............................................................................................................................................. 66
DLL Enable/Disable ................................................................................................................................... 66
Address Multiplexing .................................................................................................................................. 66
Mode Register 1 (MR1) .................................................................................................................................... 68
Output Drive Impedance ............................................................................................................................ 68
DQ On-Die Termination (ODT) ................................................................................................................... 68
DLL Reset ................................................................................................................................................... 68
ZQ Calibration ............................................................................................................................................ 69
ZQ Calibration Long ................................................................................................................................... 70
ZQ Calibration Short ................................................................................................................................... 70
AUTO REFRESH Protocol ............................................................................................................................ 71
Burst Length (BL) ....................................................................................................................................... 71
Mode Register 2 (MR2) .................................................................................................................................... 73
READ Training Register (RTR) ..................................................................................................................... 73
WRITE Protocol .......................................................................................................................................... 75
WRITE Command .......................................................................................................................................... 75
Multibank WRITE ....................................................................................................................................... 76
READ Command ............................................................................................................................................ 76
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
3
576Mb: x18, x36 RLDRAM 3
Features
AUTO REFRESH Command
............................................................................................................................ 78
INITIALIZATION Operation
............................................................................................................................ 80
WRITE Operation ............................................................................................................................................... 83
READ Operation ................................................................................................................................................. 87
AUTO REFRESH Operation
.............................................................................................................................. 90
Multiplexed Address Mode ............................................................................................................................... 93
Data Latency in Multiplexed Address Mode
........................................................................................... 98
REFRESH Command in Multiplexed Address Mode
............................................................................ 98
Mirror Function ...................................................................................................................................................102
RESET Operation ................................................................................................................................................. 102
IEEE 1149.1 Serial Boundary Scan (JTAG)
.................................................................................................... 103
Disabling the JTAG Feature ......................................................................................................................... 103
Test Access Port (TAP) .................................................................................................................................. 103
TAP Controller ............................................................................................................................................... 104
Performing a TAP RESET .............................................................................................................................. 106
TAP Registers .................................................................................................................................................. 106
TAP Instruction Set ........................................................................................................................................ 107
Revision History .................................................................................................................................................. 114
Rev. C, Production – 12/12 ...........................................................................................................................114
Rev. B, Advance – 1/12 .................................................................................................................................. 114
Rev. A, Advance – 6/11 .................................................................................................................................. 115
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
4
576Mb: x18, x36 RLDRAM 3
Features
List of Figures
Figure 1: 576Mb RLDRAM 3 Part Numbers ..................................................................................................... 2
Figure 2: Simplified State Diagram ................................................................................................................... 9
Figure 3: 32 Meg x 18 Functional Block Diagram ............................................................................................. 10
Figure 4: 16 Meg x 36 Functional Block Diagram ............................................................................................. 11
Figure 5: 168-Ball FBGA ................................................................................................................................. 16
Figure 6: Single-Ended Input Signal ............................................................................................................... 23
Figure 7: Overshoot ....................................................................................................................................... 24
Figure 8: Undershoot .................................................................................................................................... 24
Figure 9: V IX for Differential Signals ................................................................................................................ 25
Figure 10: Single-Ended Requirements for Differential Signals ........................................................................ 26
Figure 11: Definition of Differential AC Swing and tDVAC ................................................................................ 26
Figure 12: Nominal Slew Rate Definition for Single-Ended Input Signals .......................................................... 28
Figure 13: Nominal Differential Input Slew Rate Definition for CK, CK#, DKx, and DKx# .................................. 29
Figure 14: ODT Levels and I-V Characteristics ................................................................................................ 30
Figure 15: Output Driver ................................................................................................................................ 33
Figure 16: DQ Output Signal .......................................................................................................................... 38
Figure 17: Differential Output Signal .............................................................................................................. 39
Figure 18: Reference Output Load for AC Timing and Output Slew Rate ........................................................... 39
Figure 19: Nominal Slew Rate Definition for Single-Ended Output Signals ....................................................... 40
Figure 20: Nominal Differential Output Slew Rate Definition for QKx, QKx# ..................................................... 41
Figure 21: Example Temperature Test Point Location ...................................................................................... 50
Figure 22: Nominal Slew Rate and tVAC for tIS (Command and Address - Clock) ............................................... 53
Figure 23: Nominal Slew Rate for tIH (Command and Address - Clock) ............................................................ 54
Figure 24: Tangent Line for tIS (Command and Address - Clock) ...................................................................... 55
Figure 25: Tangent Line for tIH (Command and Address - Clock) ..................................................................... 56
Figure 26: Nominal Slew Rate and tVAC for tDS (DQ - Strobe) .......................................................................... 59
Figure 27: Nominal Slew Rate for tDH (DQ - Strobe) ........................................................................................ 60
Figure 28: Tangent Line for tDS (DQ - Strobe) ................................................................................................. 61
Figure 29: Tangent Line for tDH (DQ - Strobe) ................................................................................................ 62
Figure 30: MRS Command Protocol ............................................................................................................... 64
Figure 31: MR0 Definition for Non-Multiplexed Address Mode ........................................................................ 65
Figure 32: MR1 Definition for Non-Multiplexed Address Mode ........................................................................ 68
Figure 33: ZQ Calibration Timing (ZQCL and ZQCS) ....................................................................................... 70
Figure 34: Read Burst Lengths ........................................................................................................................ 72
Figure 35: MR2 Definition for Non-Multiplexed Address Mode ........................................................................ 73
Figure 36: READ Training Function - Back-to-Back Readout ............................................................................ 74
Figure 37: WRITE Command ......................................................................................................................... 75
Figure 38: READ Command ........................................................................................................................... 77
Figure 39: Bank Address-Controlled AUTO REFRESH Command ..................................................................... 78
Figure 40: Multibank AUTO REFRESH Command ........................................................................................... 79
Figure 41: Power-Up/Initialization Sequence ................................................................................................. 81
Figure 42: WRITE Burst ................................................................................................................................. 83
Figure 43: Consecutive WRITE Bursts ............................................................................................................. 84
Figure 44: WRITE-to-READ ............................................................................................................................ 84
Figure 45: WRITE - DM Operation .................................................................................................................. 85
Figure 46: Consecutive Quad Bank WRITE Bursts ........................................................................................... 86
Figure 47: Interleaved READ and Quad Bank WRITE Bursts ............................................................................. 86
Figure 48: Basic READ Burst .......................................................................................................................... 87
Figure 49: Consecutive READ Bursts (BL = 2) .................................................................................................. 88
Figure 50: Consecutive READ Bursts (BL = 4) .................................................................................................. 88
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
5
576Mb: x18, x36 RLDRAM 3
Features
Figure 51:
Figure 52:
Figure 53:
Figure 54:
Figure 55:
Figure 56:
Figure 57:
Figure 58:
Figure 59:
Figure 60:
Figure 61:
Figure 62:
Figure 63:
Figure 64:
Figure 65:
Figure 66:
Figure 67:
Figure 68:
Figure 69:
Figure 70:
Figure 71:
READ-to-WRITE (BL = 2) ............................................................................................................... 89
Read Data Valid Window ................................................................................................................ 89
Bank Address-Controlled AUTO REFRESH Cycle ............................................................................. 90
Multibank AUTO REFRESH Cycle ................................................................................................... 90
READ Burst with ODT .................................................................................................................... 91
READ-NOP-READ with ODT .......................................................................................................... 92
Command Description in Multiplexed Address Mode ..................................................................... 93
Power-Up/Initialization Sequence in Multiplexed Address Mode ..................................................... 94
MR0 Definition for Multiplexed Address Mode ................................................................................ 95
MR1 Definition for Multiplexed Address Mode ................................................................................ 96
MR2 Definition for Multiplexed Address Mode ................................................................................ 97
Bank Address-Controlled AUTO REFRESH Operation with Multiplexed Addressing .......................... 98
Multibank AUTO REFRESH Operation with Multiplexed Addressing ................................................ 98
Consecutive WRITE Bursts with Multiplexed Addressing ................................................................. 99
WRITE-to-READ with Multiplexed Addressing ............................................................................... 100
Consecutive READ Bursts with Multiplexed Addressing .................................................................. 100
READ-to-WRITE with Multiplexed Addressing ............................................................................... 101
TAP Controller State Diagram ........................................................................................................ 105
TAP Controller Functional Block Diagram ..................................................................................... 105
JTAG Operation - Loading Instruction Code and Shifting Out Data ................................................. 108
TAP Timing .................................................................................................................................. 109
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
6
576Mb: x18, x36 RLDRAM 3
Features
List of Tables
Table 1: 32 Meg x 18 Ball Assignments – 168-Ball FBGA (Top View) ................................................................................ 12
Table 2: 16 Meg x 36 Ball Assignments – 168-Ball FBGA (Top View) ............................................................................... 13
Table 3: Ball Descriptions ................................................................................................................................................ 14
Table 4: I DD Operating Conditions and Maximum Limits ............................................................................................... 17
Table 5: Absolute Maximum Ratings ................................................................................................................................ 21
Table 6: Input/Output Capacitance .................................................................................................................................. 21
Table 7: DC Electrical Characteristics and Operating Conditions....................................................................................... 22
Table 8: Input AC Logic Levels .......................................................................................................................................... 22
Table 9: Control and Address Balls ................................................................................................................................... 24
Table 10: Clock, Data, Strobe, and Mask Balls ................................................................................................................... 24
Table 11: Differential Input Operating Conditions (CK, CK# and DK
x, DK x#) ................................................... 25
tDVAC) for CK, CK#, DK
Table 12: Allowed Time Before Ringback (
x, and DK x# ................................................. 27
Table 13: Single-Ended Input Slew Rate Definition ......................................................................................................... 27
Table 14: Differential Input Slew Rate Definition ............................................................................................................... 29
Table 15: ODT DC Electrical Characteristics ..................................................................................................................... 30
Table 16: R TT Effective Impedances ............................................................................................................................... 31
Table 17: ODT Sensitivity Definition ................................................................................................................................ 32
Table 18: ODT Temperature and Voltage Sensitivity ....................................................................................................... 32
Table 19: Driver Pull-Up and Pull-Down Impedance Calculations ................................................................................. 34
Table 20: Output Driver Sensitivity Definition ................................................................................................................. 35
Table 21: Output Driver Voltage and Temperature Sensitivity ......................................................................................... 35
Table 22: Single-Ended Output Driver Characteristics ................................................................................................... 36
Table 23: Differential Output Driver Characteristics ....................................................................................................... 37
Table 24: Single-Ended Output Slew Rate Definition ...................................................................................................... 40
Table 25: Differential Output Slew Rate Definition ......................................................................................................... 41
Table 26: RL3 2133/1866 Speed Bins ................................................................................................................................. 42
Table 27: RL3 1600 Speed Bins ......................................................................................................................................... 43
Table 28: AC Electrical Characteristics .............................................................................................................................. 44
Table 29: Temperature Limits ........................................................................................................................................... 49
Table 30: Thermal Impedance .......................................................................................................................................... 49
Table 31: Command and Address Setup and Hold Values Referenced at 1 V/ns – AC/DC-Based
........................ 51
Table 32: Derating Values for tIS/ tIH – AC150/DC100-Based ...................................................................................... 52
tVAC Above V
Table 33: Minimum Required Time
IH(AC) (or Below V IL(AC) ) for Valid Transition............................ 52
Table 34: Data Setup and Hold Values at 1 V/ns (DKx, DKx# at 2V/ns) – AC/DC-Based .................................................. 57
Table 35: Derating Values for tDS/ tDH – AC150/DC100-Based.................................................................................... 58
tVAC Above V
Table 36: Minimum Required Time
IH(AC) (or Below V IL(AC) ) for Valid Transition............................ 58
Table 37: Command Descriptions .................................................................................................................................... 63
Table 38: Command Table ............................................................................................................................................... 63
Table 39: tRC_MRS MR0[3:0] values .................................................................................................................................. 66
Table 40: Address Widths of Different Burst Lengths ......................................................................................................... 71
Table 41: Address Mapping in Multiplexed Address Mode .............................................................................................. 97
Table 42: 32 Meg x 18 Ball Assignments with MF Ball Tied HIGH .................................................................................... 102
Table 43: TAP Input AC Logic Levels ................................................................................................................................ 109
Table 44: TAP AC Electrical Characteristics ...................................................................................................................... 109
Table 45: TAP DC Electrical Characteristics and Operating Conditions ........................................................................... 110
Table 46: Identification Register Definitions .................................................................................................................... 110
Table 47: Scan Register Sizes ........................................................................................................................................... 111
Table 48: Instruction Codes ............................................................................................................................................ 111
Table 49: Boundary Scan (Exit) ....................................................................................................................................... 111
Table 50: Ordering information ....................................................................................................................................... 113
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
7
576Mb: x18, x36 RLDRAM 3
General Description
General Description
The ISSI RLDRAM 3 is a high-speed memory device designed for high-bandwidth
data storage—telecommunications, networking, cache applications, etc. The chip’s 16bank architecture is optimized for sustainable high-speed operation.
The DDR I/O interface transfers two data bits per clock cycle at the I/O balls. Output
data is referenced to the READ strobes.
Commands, addresses, and control signals are also registered at every positive edge of
the differential input clock, while input data is registered at both positive and negative
edges of the input data strobes.
Read and write accesses to the RL3 device are burst-oriented. The burst length (BL) is
programmable to 2, 4, or 8 by a setting in the mode register.
The device is supplied with 1.35V for the core and 1.2V for the output drivers. The 2.5V
supply is used for an internal supply.
Bank-scheduled refresh is supported with the row address generated internally.
The 168-ball FBGA package is used to enable ultra-high-speed data transfer rates.
General Notes
• The functionality and the timing specifications discussed in this data sheet are for the
DLL enable mode of operation.
• Any functionality not specifically stated is considered undefined, illegal, and not supported, and can result in unknown operation.
• Nominal conditions are assumed for specifications not defined within the figures
shown in this data sheet.
• Throughout this data sheet, the terms "RLDRAM," "DRAM,” and "RLDRAM 3" are all
used interchangeably and refer to the RLDRAM 3 SDRAM device.
• References to DQ, DK, QK, DM, and QVLD are to be interpeted as each group collectively, unless specifically stated otherwise. This includes true and complement signals
of differential signals.
• Non-multiplexed operation is assumed if not specified as multiplexed.
• A X36 Device supplies four QK/QK# sets. One per 9 DQs. If a user only wants to use
two QK/QK# sets, this is allowed. The user needs to use QK0/QK0# and QK1/QK1#.
QK0/QK0# will control DQ[8:0] & DQ[26:18]. QK1/QK1# will control DQ[17:9] &
tQKQ02, tQKQ13. The
DQ[35:27]. The QK to DQ timing parameter to be used would be
unused QK/QK# pins should be left floating.
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
8
576Mb: x18, x36 RLDRAM 3
State Diagram
State Diagram
Figure 2: Simplified State Diagram
Initialization
sequence
NOP
READ
WRITE
RESET#
MRS
AREF
Automatic sequence
Command sequence
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
9
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
TDI
TMS
TCK
A[19:0]1
BA[3:0]
RESET#
MF
WE#
REF#
CS#
CK#
CK
RZQ
ZQ
24
Control
logic
ODT control
JTAG
Logic and
Boundary
Scan Register
Address
register
24
Notes:
Mode register
Command
decode
13
13
71
Rowaddress
MUX
Columnaddress
counter/
latch
Bank
control
logic
13
71
16
16
Bank 0
rowaddress
latch
and
decoder
ZQ CAL
5
8192
Column
decoder
32
I/O gating
DQM mask logic
8192
SENSE
AMPLIFIERS
Sense amplifiers
21
Bank 15
Bank 14
Bank 0
memory
array
(8192 x 32 x 8 x 18)2
Bank 1
Bank 0
ZQ CAL
144
144
144
CLK
in
WRITE
FIFO
and
drivers
2
1
READ n
logic
n
18
18
18
18
DQ
latch
ZQ CAL
4
2
ODT control
18
ODT control
QK/QK#
generator
18
ODT control
4
RTT
VDDQ/2
RCVRS
RTT
RTT
(0 ....17)
VDDQ/2
(0...3)
VDDQ/2
READ
Drivers
DLL
CK/CK#
1. Example for BL = 2; column address will be reduced with an increase in burst length.
2. 8 = (length of burst) x 2^ (number of column addresses to WRITE FIFO and READ logic).
8
4
Refresh
counter
ZQCL, ZQCS
Figure 3: 32 Meg x 18 Functional Block Diagram
Input
logic
Functional Block Diagrams
TDO
DM[1:0]
DK0/DK0#, DK1/DK1#
DQ[17:0]
QK0/QK0#,QK1/QK1#
QVLD
576Mb: x18, x36 RLDRAM 3
Functional Block Diagrams
10
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
ZQ
TDI
TMS
TCK
A[18:0]1
RESET#
MF
WE#
REF#
CS#
CK#
CK
RZQ
23
Control
logic
JTAG
Logic and
Boundary
Scan Register
Address
register
23
Notes:
ODT control
Mode register
Command
decode
13
13
61
Rowaddress
MUX
Columnaddress
counter/
latch
Bank
control
logic
13
61
16
16
Bank 0
rowaddress
latch
and
decoder
ZQ CAL
5
8192
Column
decoder
32
I/O gating
DQM mask logic
8192
SENSEamplifiers
AMPLIFIERS
Sense
11
Bank 15
Bank 14
Bank 0
memory
array
(8192 x 32 x 4 x 36)2
Bank 1
Bank 0
ZQ CAL
144
144
144
CLK
in
WRITE
FIFO
and
drivers
11
READ n
logic
n
36
36
36
36
DQ
latch
ZQ CAL
2
ODT control
36
4
ODT control
QK/QK#
generator
36
ODT control
8
RTT
VDDQ/2
RCVRS
RTT
VDDQ/2
READ
Drivers
DLL
CK/CK#
1. Example for BL = 2; column address will be reduced with an increase in burst length.
2. 4 = (length of burst) x 2^ (number of column addresses to WRITE FIFO and READ logic).
8
4
Refresh
counter
ZQCL, ZQCS
Figure 4: 16 Meg x 36 Functional Block Diagram
Input
logic
Functional Block Diagrams
(0...3)
RTT
(0 ....35)
VDDQ/2
TDO
DM[1:0]
DK0/DK0#, DK1/DK1#
DQ[35:0]
QK0/QK0#, QK1/QK1#
QK2/QK2#, QK3/QK3#
QVLD[1:0]
576Mb: x18, x36 RLDRAM 3
Functional Block Diagrams
11
576Mb: x18, x36 RLDRAM 3
Ball Assignments and Descriptions
Ball Assignments and Descriptions
Table 1: 32 Meg x 18 Ball Assignments – 168-Ball FBGA (Top View)
1
A
2
3
4
5
6
7
8
9
10
11
12
13
VSS
VDD
NF
VDDQ
NF
VREF
DQ7
VDDQ
DQ8
VDD
VSS
RESET#
B
VEXT
VSS
NF
VSSQ
NF
VDDQ
DM0
VDDQ
DQ5
VSSQ
DQ6
VSS
VEXT
C
VDD
NF
VDDQ
NF
VSSQ
NF
DK0#
DQ2
VSSQ
DQ3
VDDQ
DQ4
VDD
D
A11
VSSQ
NF
VDDQ
NF
VSSQ
DK0
VSSQ
QK0
VDDQ
DQ0
VSSQ
A13
E
VSS
A0
VSSQ
NF
VDDQ
NF
MF
QK0#
VDDQ
DQ1
VSSQ
CS#
VSS
1
F
A7
NF(CS1)
VDD
A2
A1
WE#
ZQ
REF#
A3
A4
VDD
A5
A9
G
VSS(A20)1
A15
A6
VSS
BA1
VSS
CK#
VSS
BA0
VSS
A8
A18
VSS(A21)1
H
A19
VDD
A14
A16
VDD
BA3
CK
BA2
VDD
A17
A12
VDD
A10
J
VDDQ
NF
VSSQ
NF
VDDQ
NF
VSS
QK1#
VDDQ
DQ9
VSSQ
QVLD
VDDQ
K
NF
VSSQ
NF
VDDQ
NF
VSSQ
DK1
VSSQ
QK1
VDDQ
DQ10
VSSQ
DQ11
L
VDD
NF
VDDQ
NF
VSSQ
NF
DK1#
DQ12
VSSQ
DQ13
VDDQ
DQ14
VDD
M
VEXT
VSS
NF
VSSQ
NF
VDDQ
DM1
VDDQ
DQ15
VSSQ
DQ16
VSS
VEXT
N
VSS
TCK
VDD
TDO
VDDQ
NF
VREF
DQ17
VDDQ
TDI
VDD
TMS
VSS
Notes:
1. F2 is the Location of the extra CS (CS1) needed to support the x18 DDP device. G1 & G13
are the locations of the additional address signals (A20 & A21 respectfully) needed to
support the 2Gb monolithic device. F2 is Internally connected and will mirror the A5 address signal when MF is asserted HIGH and has parasitic characteristics of an address pin.
G1 & G13 are VSS pins for this device, but have been designated as the location of A20
& A21 for the future 2Gb device.
2. NF balls for the x18 configuration are internally connected and have parasitic characteristics of an I/O. Balls may be connected to VSSQ.
3. MF is assumed to be tied LOW for this ball assignment.
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
12
576Mb: x18, x36 RLDRAM 3
Ball Assignments and Descriptions
Table 2: 16 Meg x 36 Ball Assignments – 168-Ball FBGA (Top View)
1
A
2
3
4
5
6
7
8
9
10
11
12
13
VSS
VDD
DQ26
VDDQ
DQ25
VREF
DQ7
VDDQ
DQ8
VDD
VSS
RESET#
B
VEXT
VSS
DQ24
VSSQ
DQ23
VDDQ
DM0
VDDQ
DQ5
VSSQ
DQ6
VSS
VEXT
C
VDD
DQ22
VDDQ
DQ21
VSSQ
DQ20
DK0#
DQ2
VSSQ
DQ3
VDDQ
DQ4
VDD
D
A11
VSSQ
DQ18
VDDQ
QK2
VSSQ
DK0
VSSQ
QK0
VDDQ
DQ0
VSSQ
A13
E
VSS
A0
VSSQ
DQ19
VDDQ
QK2#
MF
QK0#
VDDQ
DQ1
VSSQ
CS#
VSS
1
F
A7
NF(CS1)
VDD
A2
A1
WE#
ZQ
REF#
A3
A4
VDD
A5
A9
G
VSS(A20)1
A15
A6
VSS
BA1
VSS
CK#
VSS
BA0
VSS
A8
A18
VSS(A21)1
H
NF(A19)2
VDD
A14
A16
VDD
BA3
CK
BA2
VDD
A17
A12
VDD
A10
J
VDDQ
QVLD1
VSSQ
DQ27
VDDQ
QK3#
VSS
QK1#
VDDQ
DQ9
VSSQ
QVLD0
VDDQ
K
DQ29
VSSQ
DQ28
VDDQ
QK3
VSSQ
DK1
VSSQ
QK1
VDDQ
DQ10
VSSQ
DQ11
L
VDD
DQ32
VDDQ
DQ31
VSSQ
DQ30
DK1#
DQ12
VSSQ
DQ13
VDDQ
DQ14
VDD
M
VEXT
VSS
DQ34
VSSQ
DQ33
VDDQ
DM1
VDDQ
DQ15
VSSQ
DQ16
VSS
VEXT
N
VSS
TCK
VDD
TDO
VDDQ
DQ35
VREF
DQ17
VDDQ
TDI
VDD
TMS
VSS
Notes:
1. F2 is the Location of the extra CS (CS1) needed to support the x18 DDP device. G1 & G13
are the locations of the additional address signals (A20 & A21 respectfully) needed to
support the 2Gb monolithic device. F2 is Internally connected so it can mirror the A5 address signal when MF is asserted HIGH and has parasitic characteristics of an address pin.
G1 & G13 are just place holders for the future device.
2. NF ball for x36 configuration is internally connected and has parasitic characteristics of
an address (A19 for x18 configuration). Ball may be connected to VSSQ.
3. MF is assumed to be tied LOW for this ball assignment.
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
13
576Mb: x18, x36 RLDRAM 3
Ball Assignments and Descriptions
Table 3: Ball Descriptions
Symbol
Type
Description
A[19:0]
Input
Address inputs: A[19:0] define the row and column addresses for READ and WRITE operations.
During a MODE REGISTER SET, the address inputs define the register settings along with BA[3:0].
They are sampled at the rising edge of CK.
BA[3:0]
Input
Bank address inputs: Select the internal bank to which a command is being applied.
CK/CK#
Input
Input clock: CK and CK# are differential input clocks. Addresses and commands are latched on
the rising edge of CK.
CS#
Input
Chip select: CS# enables the command decoder when LOW and disables it when HIGH. When
the command decoder is disabled, new commands are ignored, but internal operations continue.
DQ[35:0]
I/O
Data input: The DQ signals form the 36-bit data bus. During READ commands, the data is referenced to both edges of QK. During WRITE commands, the data is sampled at both edges of DK.
DKx, DKx#
Input
Input data clock: DKx and DKx# are differential input data clocks. All input data is referenced
to both edges of DKx. For the x36 device, DQ[8:0] and DQ[26:18] are referenced to DK0 and
DK0#, and DQ[17:9] and DQ[35:27] are referenced to DK1 and DK1#. For the x18 device, DQ[8:0]
are referenced to DK0 and DK0#, and DQ[17:9] are referenced to DK1 and DK1#. DKx and DKx#
are free-running signals and must always be supplied to the device.
DM[1:0]
Input
Input data mask: DM is the input mask signal for WRITE data. Input data is masked when DM
is sampled HIGH. DM0 is used to mask the lower byte for the x18 device and DQ[8:0] and
DQ[26:18] for the x36 device. DM1 is used to mask the upper byte for the x18 device and
DQ[17:9] and DQ[35:27] for the x36 device. Tie DM[1:0] to VSS if not used.
TCK
Input
IEEE 1149.1 clock input: This ball must be tied to VSS if the JTAG function is not used.
TMS, TDI
Input
IEEE 1149.1 test inputs: These balls may be left as no connects if the JTAG function is not used.
WE#, REF#
Input
Command inputs: Sampled at the positive edge of CK, WE# and REF# (together with CS#) define the command to be executed.
RESET#
Input
Reset: RESET# is an active LOW CMOS input referenced to VSS. RESET# assertion and deassertion
are asynchronous. RESET# is a CMOS input defined with DC HIGH ≥ 0.8 x VDD and DC LOW ≤ 0.2 x
VDDQ.
ZQ
Input
External impedance: This signal is used to tune the device’s output impedance and ODT. RZQ
needs to be 240Ω, where RZQ is a resistor from this signal to ground.
QKx, QKx#
Output
Output data clocks: QK and QK# are opposite-polarity output data clocks. They are free-running signals and during READ commands are edge-aligned with the DQs. For the x36 device,
QK0, QK0# align with DQ[8:0]; QK1, QK1# align with DQ[17:9]; QK2, QK2# align with DQ[26:18];
QK3, QK3# align with DQ[35:27]. For the x18 device, QK0, QK0# align with DQ[8:0]; QK1, QK1#
align with DQ[17:9].
QVLDx
Output
Data valid: The QVLD ball indicates that valid output data will be available on the subsequent
rising clock edge. There is a single QVLD ball for the x18 device and two, QVLD0 and QVLD1, for
the x36 device. QVLD0 aligns with DQ[17:0]; QVLD1 aligns with DQ[35:18].
MF
Input
Mirror function: The mirror function ball is a DC input used to create mirrored ballouts for simple dual-loaded clamshell mounting. If the ball is tied to VSS, the address and command balls are
in their true layout. If the ball is tied to VDDQ, they are in the complement location. MF must be
tied HIGH or LOW and cannot be left floating. MF is a CMOS input defined with DC HIGH ≥ 0.8 x
VDD and DC LOW ≤ 0.2 x VDDQ.
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
14
576Mb: x18, x36 RLDRAM 3
Ball Assignments and Descriptions
Table 3: Ball Descriptions (Continued)
Symbol
Type
TDO
Output
Description
IEEE 1149.1 test output: JTAG output. This ball may be left as no connect if the JTAG function
is not used.
VDD
Supply
Power supply: 1.35V nominal. See Table 7 (page 22) for range.
VDDQ
Supply
DQ power supply: 1.2V nominal. Isolated on the device for improved noise immunity. See Table 7 (page 22) for range.
VEXT
Supply
Power supply: 2.5V nominal. See Table 7 (page 22) for range.
VREF
Supply
Input reference voltage: VDDQ/2 nominal. Provides a reference voltage for the input buffers.
VSS
Supply
Ground.
VSSQ
Supply
DQ ground: Isolated on the device for improved noise immunity.
NC
–
No connect: These balls are not connected to the DRAM.
NF
–
No function: These balls are connected to the DRAM, but provide no functionality.
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
15
576Mb: x18, x36 RLDRAM 3
Package Dimensions
Package Dimensions
Figure 5: 168-Ball FBGA
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
16
tCK
= idle; All banks idle; No inputs
toggling
CS# = 1; No commands; Bank address incremented and half address/
data change once every four clock
cycles
BL = 2; Sequential bank access; Bank
transitions once every tRC; Half address transitions once every tRC;
Read followed by write sequence;
Continuous data during WRITE commands
BL = 4; Sequential bank access; Bank
transitions once every tRC; Half address transitions once every tRC;
Read followed by write sequence;
Continuous data during WRITE commands
BL = 8; Sequential bank access; Bank
transitions once every tRC; Half address transitions once every tRC;
Read followed by write sequence;
Continuous data during WRITE commands
Sixteen bank cyclic refresh using
Bank Address Control AREF protocol; Command bus remains in refresh for all sixteen banks; DQs are
High-Z and at VDDQ/2; Addresses are
at VDDQ/2
Standby
current
Clock active
standby current
Operational
current: BL2
Operational
current: BL4
Operational
current: BL8
Burst refresh
current
Notes 1–6 apply to the entire table
Description
Condition
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
1215
35
1300
NA
35
IDD2 (VDD) x36
IDD2 (VEXT)
IDD3 (VDD) x18
IDD3 (VDD) x36
IDD3 (VEXT)
80
1205
IDD2 (VDD) x18
IREF1 (VEXT)
35
IDD1 (VEXT)
1550
1185
1570
1175
IDD1 (VDD) x18
IDD1 (VDD) x36
IREF1 (VDD) x18
30
ISB2 (VEXT)
IREF1 (VDD) x36
895
ISB2 (VDD) x36
80
1570
1550
35
NA
1220
35
1155
1145
35
1125
1115
30
895
870
30
30
870
ISB1 (VEXT)
ISB2 (VDD) x18
125
125
ISB1 (VDD) x36
125
-093
125
-093E
ISB1 (VDD) x18
Symbol
Table 4: IDD Operating Conditions and Maximum Limits
Electrical Characteristics – IDD Specifications
75
1420
1400
35
NA
1200
35
1140
1130
35
1110
1100
30
835
815
30
125
125
-107E
75
1420
1400
35
NA
1130
35
1080
1075
35
1055
1045
30
835
815
30
125
125
-107
70
1245
1230
35
N/A
1085
35
1030
1020
35
1000
990
30
740
725
30
125
125
-125F
70
1245
1230
35
NA
1030
35
980
970
35
950
940
30
740
725
30
125
125
-125E
70
1245
1230
35
NA
1000
35
950
945
35
925
915
30
740
725
30
125
125
-125
mA
mA
mA
mA
mA
mA
Units
7
Notes
576Mb: x18, x36 RLDRAM 3
Electrical Characteristics – IDD Specifications
17
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
BL = 4; Cyclic bank access using Dual
Bank WRITE; Half of address bits
change every two clock cycles; Continuous data; Measurement is taken
during continuous WRITE
BL = 4; Cyclic bank access using
Quad Bank WRITE; Half of address
bits change every two clock cycles;
Continuous data; Measurement is
taken during continuous WRITE;
Subject to tSAW specification
Multibank
write current:
Dual bank
write
Multibank
write current:
Quad bank
write
BL = 8; Cyclic bank access; Half of
Operating
burst write cur- address bits change every four clock
cycles; Continuous data; Measurerent :BL8
ment is taken during continuous
WRITE
BL = 4; Cyclic bank access; Half of
Operating
burst write cur- address bits change every two clock
cycles; Continuous data; Measurerent : BL4
ment is taken during continuous
WRITE
BL = 2; Cyclic bank access; Half of
Operating
burst write cur- address bits change every clock cycle; Continuous data; Measurement
rent : BL2
is taken during continuous WRITE
Multibank re- Quad bank refresh using Multibank
fresh current: AREF protocol; BL = 4; Cyclic bank
4 bank refresh access; Subject to tSAW and tMMD
specifications; DQs are High-Z and
at VDDQ/2; Bank addresses are at
VDDQ/2
Distributed
Single bank refresh using Bank Adrefresh current dress Control AREF protocol; Sequential bank access every 0.489μs;
DQs are High-Z and at VDDQ/2; Addresses are at VDDQ/2
Notes 1–6 apply to the entire table
Description
Condition
1815
55
1475
NA
45
2305
2400
80
IDD4W (VEXT)
IDD8W (VDD) x18
IDD8W (VDD) x36
IDD8W (VEXT)
IDBWR (VDD) x18
IDBWR (VDD) x36
IDBWR (VEXT)
130
1730
IDD4W (VDD) x18
IDD4W (VDD) x36
IQBWR (VEXT)
80
IDD2W (VEXT)
3195
2290
IDD2W (VDD) x36
2965
2110
IDD2W (VDD) x18
IQBWR (VDD) x18
130
IMBREF4 (VEXT)
IQBWR (VDD) x36
2155
IMBREF4 (VDD) x36
30
IREF2 (VEXT)
2130
900
IMBREF4 (VDD) x18
875
IREF2 (VDD) x18
-093E
IREF2 (VDD) x36
Symbol
Table 4: IDD Operating Conditions and Maximum Limits (Continued)
130
3195
2965
80
2400
2305
45
NA
1475
55
1815
1730
80
2290
2110
130
1950
1925
30
900
875
-093
115
3000
2890
75
2250
2170
40
NA
1335
55
1665
1590
75
2070
1910
115
2050
2030
30
840
820
-107E
115
3000
2890
75
2250
2170
40
NA
1335
55
1665
1590
75
2070
1910
115
1830
1810
30
840
820
-107
100
2615
2525
70
1960
1885
40
NA
1190
50
1460
1395
70
1805
1665
105
1900
1885
30
745
730
-125F
100
2615
2525
70
1960
1885
40
NA
1190
50
1460
1395
70
1805
1665
105
1900
1885
30
745
730
-125E
100
2615
2525
70
1960
1885
40
NA
1190
50
1460
1395
70
1805
1665
105
1660
1645
30
745
730
-125
mA
mA
mA
mA
mA
mA
mA
Units
Notes
576Mb: x18, x36 RLDRAM 3
Electrical Characteristics – IDD Specifications
18
BL = 2; Cyclic bank access; Half of
address bits change every clock cycle; Continuous data; Measurement
is taken during continuous READ
BL = 4; Cyclic bank access; Half of
address bits change every two clock
cycles; Continuous data; Measurement is taken during continuous
READ
BL = 8; Cyclic bank access; Half of
address bits change every four clock
cycles; Continuous data; Measurement is taken during continuous
READ
Operating
burst read current
example
Operating
burst read current
example
Operating
burst read current
example
Notes 1–6 apply to the entire table
Description
Condition
2250
2395
80
1740
1835
55
1450
NA
45
IDD2R (VDD) x18
IDD2R (VDD) x36
IDD2R (VEXT)
IDD4R (VDD) x18
IDD4R (VDD) x36
IDD4R (VEXT)
IDD8R (VDD) x18
IDD8R (VDD) x36
IDD8R (VEXT)
-093E
Symbol
Table 4: IDD Operating Conditions and Maximum Limits (Continued)
45
NA
1450
55
1835
1740
80
2395
2250
-093
40
NA
1315
55
1685
1595
75
2180
2045
-107E
40
NA
1315
55
1685
1595
75
2180
2045
-107
40
NA
1175
50
1475
1400
70
1895
1785
-125F
40
NA
1175
50
1475
1400
70
1895
1785
-125E
40
NA
1175
50
1475
1400
70
1895
1785
-125
mA
mA
mA
Units
Notes
576Mb: x18, x36 RLDRAM 3
Electrical Characteristics – IDD Specifications
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
19
576Mb: x18, x36 RLDRAM 3
Electrical Characteristics – IDD Specifications
Notes:
1. IDD specifications are tested after the device is properly initialized. 0°C ≤ TC ≤ +95°C;
+1.28V ≤ VDD ≤ +1.42V,+1.14V ≤ VDDQ ≤ +1.26V,+2.38V ≤ VEXT ≤ +2.63V,VREF = VDDQ/2.
2. IDD mesurements use tCK (MIN), tRC (MIN), and minimum data latency (RL and WL).
3. Input slew rate is 1V/ns for single ended signals and 2V/ns for differential signals.
4. Definitions for IDD conditions:
• LOW is defined as VIN ≤ VIL(AC)MAX.
• HIGH is defined as VIN ≥ VIH(AC)MIN.
• Continuous data is defined as half the DQ signals changing between HIGH and LOW
every half clock cycle (twice per clock).
• Continuous address is defined as half the address signals changing between HIGH and
LOW every clock cycle (once per clock).
• Sequential bank access is defined as the bank address incrementing by one every tRC.
• Cyclic bank access is defined as the bank address incrementing by one for each command access. For BL = 2 this is every clock, for BL = 4 this is every other clock, and for
BL = 8 this is every fourth clock.
5. CS# is HIGH unless a READ, WRITE, AREF, or MRS command is registered. CS# never transitions more than once per clock cycle.
6. IDD parameters are specified with ODT disabled.
7. Upon exiting standby current conditions, at least one NOP command must be issued
with stable clock prior to issuing any other valid command.
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
20
576Mb: x18, x36 RLDRAM 3
Electrical Specifications – Absolute Ratings and I/O Capacitance
Electrical Specifications – Absolute Ratings and I/O Capacitance
Absolute Maximum Ratings
Stresses greater than those listed may cause permanent damage to the device. This is a
stress rating only, and functional operation of the device at these or any other conditions outside those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may adversely affect reliability.
Table 5: Absolute Maximum Ratings
Symbol
Parameter
Min
Max
Units
VDD
VDD supply voltage relative to VSS
–0.4
1.975
V
VDDQ
Voltage on VDDQ supply relative to VSS
–0.4
1.66
V
Voltage on any ball relative to VSS
–0.4
1.66
V
Voltage on VEXT supply relative to VSS
–0.4
2.8
V
VIN,VOUT
VEXT
Input/Output Capacitance
Table 6: Input/Output Capacitance
Notes 1 and 2 apply to entire table
RL3-2133
Capacitance Parameters
Symbol
Min
CK/CK#
CCK
ΔC: CK to CK#
CDCK
Single-ended I/O: DQ, DM
Input strobe: DK/DK#
RL3-1866
Max
Min
1.3
2.1
0
0.15
CIO
1.9
CIO
1.9
RL3-1600
Max
Min
Max
Units
1.3
2.1
1.3
2.2
pF
0
0.15
0
0.15
pF
2.9
1.9
3.0
2.0
3.1
pF
2.9
1.9
3.0
2.0
3.1
pF
Notes
3
CIO
1.9
2.9
1.9
3.0
2.0
3.1
pF
ΔC: DK to DK#
CDDK
0
0.15
0
0.15
0
0.15
pF
ΔC: QK to QK#
CDQK
0
0.15
0
0.15
0
0.15
pF
ΔC: DQ to QK or DQ to DK
CDIO
–0.5
0.3
–0.5
0.3
–0.5
0.3
pF
4
Output strobe: QK/QK#, QVLD
Inputs (CMD, ADDR)
ΔC: CMD_ADDR to CK
JTAG balls
RESET#, MF balls
Notes:
CI
1.25
2.25
1.25
2.25
1.25
2.25
pF
5
CDI_CMD_ADDR
–0.5
0.3
–0.5
0.3
–0.4
0.4
pF
6
CJTAG
1.5
4.5
1.5
4.5
1.5
4.5
pF
7
CI
–
3.0
–
3.0
–
3.0
pF
1. +1.28V ≤ VDD ≤ +1.42V, +1.14V ≤ VDDQ ≤ 1.26V, +2.38V ≤ VEXT ≤ +2.63V, VREF = VSS, f = 100
MHz, TC = 25°C, VOUT(DC) = 0.5 × VDDQ, VOUT (peak-to-peak) = 0.1V.
2. Capacitance is not tested on ZQ ball.
3. DM input is grouped with the I/O balls, because they are matched in loading.
4. CDIO = CIO(DQ) - 0.5 × (CIO [QK] + CIO [QK#]).
5. Includes CS#, REF#, WE#, A[19:0], and BA[3:0].
6. CDI_CMD_ADDR = CI (CMD_ADDR) - 0.5 × (CCK [CK] + CCK [CK#]).
7. JTAG balls are tested at 50 MHz.
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
21
576Mb: x18, x36 RLDRAM 3
AC and DC Operating Conditions
AC and DC Operating Conditions
Table 7: DC Electrical Characteristics and Operating Conditions
Note 1 applies to the entire table; Unless otherwise noted: 0°C ≤ TC ≤ +95°C; +1.28V ≤ VDD ≤ +1.42V
Description
Symbol
Min
Max
Units
Supply voltage
VEXT
2.38
2.63
V
Supply voltage
VDD
1.28
1.42
V
Isolated output buffer supply
VDDQ
1.14
1.26
V
Reference voltage
VREF
0.49 × VDDQ
0.51 × VDDQ
V
Input HIGH (logic 1) voltage
VIH(DC)
VREF + 0.10
VDDQ
V
Input LOW (logic 0) voltage
VIL(DC)
VSS
VREF - 0.10
V
Input leakage current: Any input 0V ≤ VIN ≤ VDD, VREF ball
0V ≤ VIN ≤ 1.1V (All other balls not under test = 0V)
ILI
–2
2
μA
Reference voltage current (All other balls not under test =
0V)
IREF
–5
5
μA
Notes:
Notes
2, 3
1. All voltages referenced to VSS (GND).
2. The nominal value of VREF is expected to be 0.5 × VDDQ of the transmitting device. VREF is
expected to track variations in VDDQ.
3. Peak-to-peak noise (non-common mode) on VREF may not exceed ±2% of the DC value.
DC values are determined to be less than 20 MHz. Peak-to-peak AC noise on VREF should
not exceed ±2% of VREF(DC). Thus, from VDDQ/2, VREF is allowed ±2% VDDQ/2 for DC error
and an additional ±2% VDDQ/2 for AC noise. The measurement is to be taken at the
nearest VREF bypass capacitor.
Table 8: Input AC Logic Levels
Notes 1-3 apply to entire table; Unless otherwise noted: 0°C ≤ TC ≤ +95°C; +1.28V ≤ VDD ≤ +1.42V
Description
Symbol
Min
Max
Units
Input HIGH (logic 1) voltage
VIH(AC)
VREF + 0.15
–
V
Input LOW (logic 0) voltage
VIL(AC)
–
VREF - 0.15
V
Notes:
1. All voltages referenced to VSS (GND).
2. The receiver will effectively switch as a result of the signal crossing the AC input level,
and will remain in that state as long as the signal does not ring back above/below the
DC input LOW/HIGH level.
3. Single-ended input slew rate = 1 V/ns; maximum input voltage swing under test is
900mV (peak-to-peak).
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
22
576Mb: x18, x36 RLDRAM 3
AC and DC Operating Conditions
Figure 6: Single-Ended Input Signal
VIL and VIH levels with ringback
1.60V
VDDQ + 0.4V narrow
pulse width
1.20V
VDDQ
Minimum VIL and VIH levels
0.750V
0.70V
VIH(AC)
VIH(DC)
0.624V
0.612V
0.60V
0.588V
0.576V
0.50V
0.45V
0.750V
VIH(AC)
0.70V
VIH(DC)
0.624V
0.612V
0.60V
0.588V
0.576V
VIL(DC)
VIL(AC)
VREF + AC noise
VREF + DC error
VREF - DC error
VREF - AC noise
0.50V
VIL(DC)
0.450V
VIL(AC)
0.0V
–0.40V
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
VSS
VSS - 0.4V narrow
pulse width
23
576Mb: x18, x36 RLDRAM 3
AC and DC Operating Conditions
AC Overshoot/Undershoot Specifications
Table 9: Control and Address Balls
RL3-2133
RL3-1866
RL3-1600
Maximum peak amplitude allowed for overshoot area
Parameter
0.4V
0.4V
0.4V
Maximum peak amplitude allowed for undershoot area
0.4V
0.4V
0.4V
Maximum overshoot area above VDDQ
0.25 Vns
0.28 Vns
0.33 Vns
Maximum undershoot area below VSS/VSSQ
0.25 Vns
0.28 Vns
0.33 Vns
RL3-2133
RL3-1866
RL3-1600
Maximum peak amplitude allowed for overshoot area
0.4V
0.4V
0.4V
Maximum peak amplitude allowed for undershoot area
0.4V
0.4V
0.4V
Maximum overshoot area above VDDQ
0.10 Vns
0.11 Vns
0.13 Vns
Maximum undershoot area below VSS/VSSQ
0.10 Vns
0.11 Vns
0.13 Vns
Table 10: Clock, Data, Strobe, and Mask Balls
Parameter
Figure 7: Overshoot
Maximum amplitude
Overshoot area
Volts (V)
VDDQ
Time (ns)
Figure 8: Undershoot
VSS/VSSQ
Volts (V)
Undershoot area
Maximum amplitude
Time (ns)
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
24
576Mb: x18, x36 RLDRAM 3
AC and DC Operating Conditions
Table 11: Differential Input Operating Conditions (CK, CK# and DKx, DKx#)
Notes 1 and 2 apply to entire table
Parameter/Condition
Symbol
Min
Differential input voltage logic HIGH – slew
VIH,diff_slew
+200
n/a
mV
3
Differential input voltage logic LOW – slew
VIL,diff_slew
n/a
-200
mV
3
Differential input voltage logic HIGH
VIH,diff(AC)
2 × (VIH(AC) - VREF)
VDDQ
mV
4
Differential input voltage logic LOW
VIL,diff(AC)
VSSQ
2 × (VIL(AC) - VREF )
mV
5
Differential input crossing voltage relative to VDD/2
Max
Units
Notes
VIX
VREF(DC) - 150
VREF(DC) + 150
mV
6
Single-ended HIGH level
VSEH
VIH(AC)
VDDQ
mV
4
Single-ended LOW level
VSEL
VSSQ
VIL(AC)
mV
5
Notes:
1.
2.
3.
4.
CK/CK# and DKx/DKx# are referenced to VDDQ and VSSQ.
Differential input slew rate = 2 V/ns.
Defines slew rate reference points, relative to input crossing voltages.
Maximum limit is relative to single-ended signals; overshoot specifications are applicable.
5. Minimum limit is relative to single-ended signals; undershoot specifications are applicable.
6. The typical value of VIX is expected to be about 0.5 × VDDQ of the transmitting device
and VIX is expected to track variations in VDDQ. VIX indicates the voltage at which differential input signals must cross.
Figure 9: VIX for Differential Signals
VDDQ
VDDQ
CK#, DKx#
CK#, DKx#
X
VIX
VIX
VDDQ/2
X
X
VDDQ/2
VIX
X
CK, DKx
VSSQ
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
VIX
CK, DKx
VSSQ
25
576Mb: x18, x36 RLDRAM 3
AC and DC Operating Conditions
Figure 10: Single-Ended Requirements for Differential Signals
VDDQ
VSEH,min
VDDQ/2
VSEH
CK or DKx
VSEL,max
VSEL
VSS
Figure 11: Definition of Differential AC Swing and tDVAC
tDVAC
VIH,diff(AC)min
VIH,diff_slew,min
CK - CK#
DKx - DKx#
0.0
VIL,diff_slew,max
VIL,diff(AC)max
half cycle
Integrated Silicon Solution, Inc. - www.issi.com Rev. 00C
11/21/2014
tDVAC
26
576Mb: x18, x36 RLDRAM 3
AC and DC Operating Conditions
Table 12: Allowed Time Before Ringback (tDVAC) for CK, CK#, DKx, and DKx#
Slew Rate (V/ns)
MIN tDVAC (ps) at |VIH/VIL,diff(AC)|
>4.0
175
4.0
170
3.0
167
2.0
163
1.9
162
1.6
161
1.4
159
1.2
155
1.0
150
2.0
175
2.0
170
1.5
167
1.0
163
0.9
162
0.8
161
0.7
159
0.6
155
0.5
150
2.0
175
2.0
170
1.5
167
1.0
163
0.9
162
0.8
161
0.7
159
0.6
155
0.5
150