Assembly instruction
CAS25022E
APD 6-/7-way
Assembly instruction
APD 6-/7-way
Fixed connector
Jam nut receptacle
Free connector
Fixed connector
Flange receptacle
APD-1AP6, 6-way for stamped contacts
APD-1AP6-EP 6-way for press in contacts
APD-1AP7-EP 7-way for press in contacts
APD-1AP7, 7-way for stamped contacts
No endbell mountable
Front panel mounting possible
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 2 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
Content
I.) APD 6-/7-way with stamped crimp contacts ..................................................... 3!
1.)!
Connector Types ............................................................................................ 3!
2.)!
Stamped Crimp Contacts................................................................................ 4!
3.)!
Single Wire Seal ............................................................................................. 4!
4.)!
Crimp with Hand Crimp Tool........................................................................... 5!
5.)!
Crimp with Crimp Machine.............................................................................. 5!
6.)!
Insertion and Extraction of Stamped Contacts................................................ 6!
II.) Assembly instruction with Press-in Contacts (pin contacts only)................. 7!
1.)!
Connector Types ............................................................................................ 7!
2.)!
Press-In Contacts (1,6mm)............................................................................. 7!
3.)!
Stripping the Cable ......................................................................................... 8!
4.)!
Crimp instruction for Press-in Contacts .......................................................... 8!
5.)!
Insertion of Press-in Contacts......................................................................... 9!
III.) Mounting Cut-out and Accessory .................................................................. 10!
1.)!
Mounting Cut-out .......................................................................................... 10!
2.)!
Flange Sealing.............................................................................................. 10!
3.)!
Metal Flange Support ................................................................................... 10!
4.)!
Blanking Plug (Blind seal, wire filler)............................................................. 11!
5.)!
Mounting of Jam Nut Receptacle.................................................................. 11!
6.)!
Tools for Tighten the Jam Nut ...................................................................... 12!
IV.) Product safety and warranty .......................................................................... 13!
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 3 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
I.) APD 6-/7-way with stamped crimp contacts
1.) Connector Types
Fixed connector
Flange receptacle
packaging unit 100 pieces
Order number
6-way
7-way
Fixed connector
Jam nut receptacle
Order name. Code
Colour
120110-0083
APD-1AP6
1
black
(1. contact cavity
closed)
121583-0020
APD-1AP7
1
black
packaging unit 100 pieces
Order number
Order name. Code
Contact cavity
closed
Colour
6-way
121583-0061
APD-1CP6
1
black
(1. contact cavity
closed)
7-way
121583-0019
APD-1CP7
1
black
Colour
black
(1. contact cavity
closed)
Free connector
packaging unit 100 pieces
Order number
Order name.
Code
120110-0024
APD-1BS6
1
121583-0018
APD-1BS7
1
Contact cavity
closed
6-way
6-polig
7-way
black
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 4 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
2.) Stamped Crimp Contacts
The pin and socket contacts are built of high conductive material.
Socket contact, size 1,6mm
Order number.: 192900-0001
Crimp diameter: 0,75-1,5mm²
Standard plating: tinned
3000 contacts per reel
Single contact, order number
192900-0003
Pin contact, size 1,6mm
Order number.: 192900-0000
Crimp diameter: 0,75-1,5mm²
Standard plating: tinned
3000 contacts per reel
Single contact, order number
192900-0002
The contacts get crimped with insulation crimp. The crimping measurements are the same
for pin and socket contacts in uncrimped condition.
3.) Single Wire Seal
Before skinning the cable, push
single wire seal in direction of
arrow onto the cable..
(optional)
Bestell-Bez.
Bestell-Nr.
10GR3940
121667-0022
∅ 1,4 – 2,0mm grau
10YE3940
121667-0023
∅ 1,9 – 2,1mm gelb
10RD3940
121667-0024
∅ 1,2 − 1,6mm rot
The single wire sealing is not going
to be crimped
Single wire seal push to cable
Strip end
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 5 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
4.) Crimp with Hand Crimp Tool
Single contacts are going to be crimped with hand crimp tool..
Wire size
16-18 AWG; 0,75–1,5mm²
Order number.
CHT-Trident 121586-5237
During the processing the crimping specification CAS25047 is to be
considered
5.) Crimp with Crimp Machine
For high volume production, crimp machinery with interchangeable crimp tool as the
Mecal-TT and WWZ-Mecal-EVS (mini applicator) are used.
Crimp machine Mecal-TT Press
Order name:
Mecal-TT
Order number:
121586-5225
Order name:
WWZ-Mecal-EVS
Order number:
121586-5217
Crimp tool
(mini applicator) WWZ-Mecal-EVS
During the processing the crimping specification CAS25046 is to be
considered
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 6 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
6.) Insertion and Extraction of Stamped Contacts
There is no need of insertion tools.
A.) The stamped contacts get mounted from the rear panel of the connector into the contact cavity by hand
until it snaps in. To the front, the contact is bounded by the shoulder at the contact.
B.) Single Wire Seal push into connector housing. (Optional)
Extraction
The extraction of stamped contacts, pin and socket from the housing occurs from the front with the extraction
tool. The extraction tool gets inserted into the contact cavity on the mating face. See picture 1. Eventually the
snap springs get clamped and the cable can be pulled out from the cable face. See picture 2.
Extraction tool
Order number: 192922-1450
Extraction tool
picture 1
picture 2
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 7 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
II.) Assembly instruction with Press-in Contacts (pin contacts only)
In addition to the standard contacts also press-in contacts may be used for the APD 6-/ 7-way fixed connector.
The pressed-in contacts cannot be exchanged anymore.
1.) Connector Types
Fixed connector
Flange receptacle
Packaging unit: 100 pieces
6-way
7-qay
Bestell-Nr.
Bestell-Bez.
Code
Farbe
120110-0020
APD-1AP6-EP
1
black
(1. contact cavity
closed)
121583-0205
APD-1AP7-EP
1
black
Fixed connector
Jam nut receptacle
Packaging unit: 100 pieces
Bestell-Nr.
Bestell-Bez.
Code
Farbe
6-polig
Auf Anfrage
APD-1CP6-EP
1
black
(1. contact cavity
closed)
7-polig
121583-0028
APD-1CP7-EP
1
black
2.) Press-In Contacts (1,6mm)
Order number:
330-8672-021 (tinned), (0,75-1,5mm²)
330-8672-019 (tinned), (0,35-0,75mm²)
With plating, flash plated, on request
Packaging unit: 100 pieces
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 8 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
3.) Stripping the Cable
Hand crimp tool
The crimping process occurs with a hand crimp tool:
tool M22520-1-01
locator CT 120090-163
The crimp adjustment should be read of
and adjusted at the locator.
Pin contact
330-8672-021
330-8672-019
Hand crimp tool
M22520-1-01
Order no.:
995-0001-585
Locator
for hand crimp tool
CT120090-163
120090-0163
4.) Crimp instruction for Press-in Contacts
The stripping length for the press-in contact is 6,0+/0,3mm. Strip it with the proper stripping clamp or
stripping machine.
The stranded wires must not be damaged during this
process.
1.) Strip to the proper length
2.) Add the right locator (turret) to the hand crimp tool
3.) Adjust the crimp diameter with the rotatable scale (see note Turret)
4. Place the contact in the locator and insert the stripped cable into the contact
5.) Press the clamp until reopening is possible
6.) Remove and check the contact crimp. Check the accurate position of the
stranded wires through the visual holes.
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 9 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
Crimp error
All right!
Cable insulation
Stranded wire
Contact
Visual hole
Wrong
Loose stranded
The minimum retention force are fixed in the standard DIN EN 60352-2-2006
These depend to consider on the cable diameter.
5.) Insertion of Press-in Contacts
After having crimped, the press-in
contact gets inserted into the insulator
from the cable face (contact cavity).
With the insertion tool CIT-APD-16
TIP that is integrated in the hand gear
press, the press-in contact gets
pressed-in until catch (control
measurement 4,1mm).
The insertion tool has to press on the
shoulder of the contact during process
Order name:
Hand gear press
CHPZ-240
Insertion tool
CIT-APD-16 TIP
Order umber:
121586-0081
317-8648-008
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 10 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
III.) Mounting Cut-out and Accessory
1.) Mounting Cut-out
Mounting cut-out for all APD 6-/7-way
fixed connectors, Flange receptacles.
The thread in the bulkhead conforms
with the max. torque for M3 screws.
or M3
Mounting cut-out for all
APD 6-/7-way fixed connectors,
Jam nut receptacle.
2.) Flange Sealing
Order number.: 075-8503-000
Seal
O-Ring
groove
Rear panel mounting
Flange sealing, rubber, for sealing the flange
receptacle.
The sealing gets mounted from the mating
face.
Front panel mounting
An O-Ring is used for front panel mounting.
O-Ring
Inappropriate for 121583-0020
APD-1AP7 (for Trident contacts).
3.) Metal Flange Support
Order number.: 066-8516-005
Flange support for all fixed connectors, flange
receptacles. The flange gets inserted from the
mating face with its plane surface (rear panel)
pressing the flange of the receptacle (front
panel mounting).
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 11 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
4.) Blanking Plug (Blind seal, wire filler)
For empty contact cavities, there are
blanking plugs for sealing. Insert the
blanking plug as shown in the draft
final position.
final position
blanking plug
Contact cavity
backside
Order name:
10WH3940
Order number:
121667-0025
5.) Mounting of Jam Nut Receptacle
Jam nut receptacle
housing
Jam nut
Standard: 217-8516-002
Special: 217-8516-001
Torque: 6 +1 Nm
O-Ring
Schottwanddicke
Standard: 1,0 – 4,0mm
Special: 2,0 – 5,0mm
HNBR, ∅31,5 x 3
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 12 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
6.) Tools for Tighten the Jam Nut
Order number: 317-8649-034
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 13 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
IV.) Product safety and warranty
THIS NOTE MUST BE READ IN CONJUNCTION WITH THE PRODUCT DATA SHEET/CATALOG.
Failure to observe the advice in this information sheet and the operating conditions specified in the Product Data Sheet/Catalog could
result in hazardous situations.
MATERIAL CONTENT AND PHYSICAL FORM
Electrical connectors do not usually contain hazardous materials. They contain conducting and non-conducting materials and can be
divided into two groups.
a) Printed circuit types and low cost audio types which employ all plastic insulators and casings.
b) Rugged, Fire Barrier and High Reliability types with metal casings and either natural rubber, synthetic rubber, plastic or glass
insulating materials. Contact materials vary with type of connector and also application and are usually manufactured from either:
Copper, copper alloys, nickel, alumel, chromel or steel. In special applications, other alloys may be specified.
FIRE CHARACTERISTICS AND ELECTRIC SHOCK HAZARD
There is no fire hazard when the connector is correctly wired and used within the specified parameters. Incorrect wiring or assembly of
the connector or careless use of metal tools or conductive fluids, or transit damage to any of the component parts may cause electric
shock or burns. Live circuits must not be broken by separating mated connectors as this may cause arcing, ionisation and burning.
Heat dissipation is greater at maximum resistance in a circuit. Hot spots may occur when resistance is raised locally by damage, e.g.
cracked or deformed contacts, broken strands of wire. Local overheating may also result from the use of the incorrect application tools
or from poor quality soldering or slack screw terminals. Overheating may occur if the ratings in the product Data Sheet/Catalog are
exceeded and can cause breakdown of insulation and hence electric shock.
If heating is allowed to continue it intensifies by further increasing the local resistance through loss of temper of spring contacts,
formation of oxide film on contacts and wires and leakage currents through carbonisation of insulation and tracking paths.
Fire can then result in the presence of combustible materials and this may release noxious fumes. Overheating may not be visually
apparent. Burns may result from touching overheated components.
HANDLING
Care must be taken to avoid damage to any component parts of electrical connectors during installation and use. Although there are
normally no sharp edges, care must be taken when handling certain components to avoid injury to fingers.
Electrical connectors may be damaged in transit to the customers, and damage may result in creation of hazards. Products should
therefore be examined prior to installation/use and rejected if found to be damaged.
DISPOSAL
Incineration of certain materials may release noxious or even toxic fumes.
APPLICATION
Connectors with exposed contacts should not be selected for use on the current supply side of an electrical circuit, because an electric
shock could result from touching exposed contacts on an unmated connector. Voltages in excess of 30 V ac. or 42.5 V dc
are potentially hazardous and care should be taken to ensure that such voltages cannot be transmitted in any way to exposed metal
parts of the connector body. The connector and wiring should be checked, before making live, to have no damage to metal parts or
insulators, no solder blobs, loose strands, conducting lubricants, swarf, or any other undesired conducting particles.
Insulation resistance should be checked to make certain that no low resistance joints or spurious conducting paths are existing
between contacts and exposed metal parts of the connector body. Further, the contact resistance of the connectors should be
measured within the electrical circuit in order to identify high resistances, which result in excessive connector heating.
Always use the correct application tools as specified in the Data Sheet/Catalogue. Do not permit untrained personnel to wire,
assemble or tamper with connectors. For operation voltage please see appropriate national regulations.
IMPORTANT GENERAL INFORMATION
(i) Air and creepage paths/Operating voltage
The admissible operating voltages depend on the individual applications and the valid national and other applicable safety regulations.
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......
Seite 14 von 14
Assembly instruction
CAS25022E
APD 6-/7-way
For this reason the air and creepage path data are only reference values. Observe reduction of air and creepage paths due to
PC board and/or harnessing.
(ii) Temperature
All information given are temperature limits.
The operation temperature depends on the individual application.
(iii) Other important information
ITT Industries continuously endeavours to improve their products. Therefore, ITT Industries products may deviate from the description,
technical data and shape as shown in this catalog and data sheets.
(iv) Harnessing and Assembly Instructions
If applicable, our special harnessing and/or assembly instruction has to be adhered to.
This is provided on request.
ITT Industries Cannon GmbH
Cannonstrasse 1
D-71384 Weinstadt
Tel. +49 (0) 7151 699-0
Fax. +49 (0) 7151 699-217
info@de.itt.com
www.ittcannon.com
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU / WD
NK
HES
-4263W
11.06.2012
ITT Cannon GmbH, D-71384 Weinstadt
file: t:\c...\c.......