GK473.0075PD3

GK473.0075PD3

  • 厂商:

    IVO

  • 封装:

  • 描述:

    GK473.0075PD3 - Gateway Fieldbus interface for spindle position displays CANopen, DeviceNet, Profibu...

  • 数据手册
  • 价格&库存
GK473.0075PD3 数据手册
Gateway Fieldbus interface for spindle position displays CANopen, DeviceNet, Profibus-DP GK473 Features – Fieldbus gateway for CANopen, DeviceNet, Profibus – Operation mode status indicator by LED´s – Interface RS485 – Auto-Check functions GK473 with Profibus-DP interface Technical data - electrical ratings Voltage supply Current consumption Display LED operating status 12...24 VDC ≤200 mA 4 LED´s as operating status indicators DP (green) fieldbus operating status DP (red) operating and error status RX / TX (yellow) receiving / transmitting a token (RS485) CANopen, DeviceNet, ProfibusDPV0 EIA RS485 (ASCII protocol) >10 years (flash / EEPROM) Subject to modification in technic and design. Errors and omissions excepted. Technical data - mechanical design Operating temperature Storing temperature Relative humidity Protection DIN EN 60529 E-connection Housing type Dimensions W x H x L Mounting Weight approx. Material -10...+50 °C -20...+70 °C 80 % non-condensing IP 20 D-SUB-female connector, 9-pin Plug-in screw terminals DIN rail housing EN 50022 22.6 x 99 x 114.5 mm DIN rail housing EN 50022 120 g Polyamide green, UL 94V-0 Interfaces Interface to SPA Data memory Programmable parameters Auto-Check functions Auto Scan SPA Auto Message SPA Position Auto Message SPA Error DIN EN 61000-6-4 DIN EN 61000-6-2 Emitted interference Interference immunity 1 www.baumerivo.com www.baumerivo.com 30/10/2008 Fieldbus interface for spindle position displays CANopen, DeviceNet, Profibus-DP Gateway GK473 Part number GK473.00 7 P D Firmware 2 Without data carrier 3 Including data carrier (describing file GSD/ EDS/Profibus function modules and manual) Fieldbus connection D With connector D-SUB Fieldbus interface 3 Profibus-DP 5 CANopen 8 DeviceNet Interface to SPA 7 RS485 Auto-Check functions Auto Scan SPA If this function is activated, during operation the gateway will proceed a continous AutoScan of all SPAs connected checking whether they are “in position”. This information can be collected by special command for fieldbus readin upon request. AutoScan spares the fieldbus master of cyclic scanning every SPA himself. Auto Message SPA Position If this function is activated, in the following events the gateway will automatically provide a message without prior request by the fieldbus master: After all SPAs having previously been “in position” this is no longer valid for at least one SPA. The message will also be given if previously at least one SPA was not “in position” and now all SPAs are “in position” again. Auto Message SPA Error If this function is activated, in the following events the gateway will automatically provide a message without prior request by the fieldbus master. After all SPAs having been previously in status “no error” (“in position” or “not in position”) now at least one SPA is in “error” status. After previously at least one SPA having been in “error” status, now all SPAs are again “in position” or “not in position”. Description GK473 gateway (interface converter) enables networking of approx. 32 spindle position displays (SPA) of the Baumer IVO multicon system (for example N 140, N 141, N 150 and a fieldbus-capable control (PLC). The gateway is converting the SPA’s RS485 interface into a fieldbus interface and viceversa. Four LEDs serve as status indicators. The gateway is capable of Auto-Check functions what means a relief to the control. One bus segment allows operation of several gateways for connecting more SPAs. The gateway provides a small housing for DIN rail mounting, Node-ID and bus termination can be parameterized. 2 www.baumerivo.com 30/10/2008 Subject to modification in technic and design. Errors and omissions excepted. Gateway Fieldbus interface for spindle position displays CANopen, DeviceNet, Profibus-DP GK473 Terminal assignment Connection RS485 (plug in screw terminal) Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Assignment Shield GND (signal) Data line+ Data lineGND B UB GND B UB Connection DeviceNet (D-SUB) Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Assignment – CAN-Bus signal (dominant low) – – – – CAN-Bus signal (dominant high) DRAIN – Connection CANopen (D-SUB) Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Assignment Shield / ground CAN-Bus signal (dominant low) – – – – CAN-Bus signal (dominant high) – – Connection Profibus (D-SUB) Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Assignment Shield / ground – Profibus B (+) – – – – Profibus A (-) – Terminal significance RS485 The serial interface is conform to EIA RS485. Max. 32 multicon spindle positioning displays can be networked in any combination to RS485 bus. CANopen The CANopen interface is in line with CAN-Bus standard ISO / DIS 11898 CAN 2.0B. Optional data transmission rates are 10 k, 20 k, 50 k, 100 k, 125 k, 250 k and 500 kBaud. The baudrate is DIP-switch settable, the user address is set by two turnable switches. The supported CANopen- communication profile is DS 301. Since there is no CANopen application profile available for this kind of gateway it is manufacturer-specific. CANopen connection is by integrated 9-pin D-SUB-connector (female). Any CAN bus loops required can be effected in the connector itself (not included in the delivery). DeviceNet DeviceNet is based on CAN Bus (Layer 2), in line with CANBus standards ISO / DIS 11898 CAN 2.0B. Optional transmission rates of 125 kBit/s, 250 kBit/s and 500 kBit/s. The baudrate is set by DIP switch. The user address (MAC ID, 0..63) is set by help of two rotary switches. Since there Is no existing standard DeviceNet profile for this kind of gateway it is manufacturer-specific. DeviceNet connection is by integrated 9-pin D-SUB connector (female). Any CAN bus loops required can be realized in the connector itself (not included in the delivery). Profibus The Profibus-DP interface is in line with Profibus standard DP-V0 (cyclic communication) according to DIN EN 50170. Optional data transmission rates are 9600, 19200, 93,75 k, 187,5 k, 500 k, 1.5 M, 3 M, 6 M and 12 MBaud. The baud rate applied is automatically recognised. Since there is no standard gateway profile available it is manufacturerspecific. Profibus-DP connection is by integrated 9-pin DSUB connector (female). Any Profibus loops required can be realized in the connector itself (not included in the delivery). 3 www.baumerivo.com www.baumerivo.com 30/10/2008 Subject to modification in technic and design. Errors and omissions excepted. Fieldbus interface for spindle position displays CANopen, DeviceNet, Profibus-DP Gateway GK473 Function modules Profibus function module Function modules are capable of taking over basic functions in the communication between PLC and Profibus gateway what means a considerable relief to the S7 operator. Step7® provides convenient implementation of the Baumer IVO multicon project. The function modules written into AWL sub-software (FC’s) are availabe as pure text files and additionally as complete Step7® example project. This allows convenient individual modifications. The functions comprise reading and writing of current and target values into the spindle position displays (SPA), profile administration and storage in the PLC, automatic address designation for the SPAs connected as well as bit parameter administration. Other integrated functions enable optimized evaluation of automatic gateway scanning functions. The function modules are intended for a Siemens® S7 300DP® and available in AWL, however it can be taken for granted that by slight modifications they can be easily implemented into other AWL-capable PLCs by Siemens. Dimensions 111 22.6 99 4 www.baumerivo.com 30/10/2008 Subject to modification in technic and design. Errors and omissions excepted.
GK473.0075PD3 价格&库存

很抱歉,暂时无法提供与“GK473.0075PD3”相匹配的价格&库存,您可以联系我们找货

免费人工找货