Preset counters electronic
2 presets, totalizer and batch counter Display LED, 5-digits, programmable
NE216
Features – Preset counter with two presets – Display 5-digits – Totalizer, hour counter – Operating mode, start count, scaling factor programmable – Connection: Incremental encoder or digital sensors – Step and trailing preset programmable – Interface RS485
NE216 - LED Preset counter Technical data - electrical ratings Voltage supply 22...50 VAC (50/60 Hz) 85...265 VAC (50/60 Hz) 12...30 VDC 5 VA, 5 W AC: 24 VDC ±20 % / 100 mA DC: 9...28 VDC / 100 mA LED, 7-segment display 5-digits 7.6 mm Preset counter Main counter with 2 presets Totalizer Hour counter 0.0001...9999.99 Adding or subtracting A-B (difference counting) A+B total (parallel counting) Up/Down A 90° B phase evaluation 3 Hz, 25 Hz, 10 kHz programmable Step preset, Trailing preset, Time meter and hour counter >10 years in EEPROM Button, electric or automatic Optocoupler Normally open or closed, programmable 0.01...99.99 s RS485 Protection class II Overvoltage category II Pollution degree 2 DIN EN 61000-6-4 DIN EN 61000-6-2 1 www.baumerivo.com www.baumerivo.com Approvals Technical data - electrical ratings Programmable parameters Operating modes Sensor logic Scaling factor Count mode Control inputs UL/cUL, CE conform
Power consumption Sensor supply Display Number of digits Digit height Function
Technical data - mechanical design Operating temperature Storing temperature Relative humidity E-connection Core cross-section Protection DIN EN 60529 Operation / keypad Housing type Dimensions W x H x L Installation depth Mounting Cutout dimensions Materials Weight approx. 0...+50 °C -20...+70 °C 80 % non-condensing Plug-in screw terminals 1.5 mm² IP 65 face with seal Membrane with softkeys Built-in housing 48 x 48 x 100 mm 100 mm Clip frame 45 x 45 mm (+0.6) Housing: Makrolon 6485 (PC) Keypad: Polyester 150 g
Subject to modification in technic and design. Errors and omissions excepted. 30/10/2008
Scaling factor Count modes
Counting frequency Operating modes Data memory Reset Outputs electronic Outputs relay Output holding time Interface Standard DIN EN 61010-1 Emitted interference Interference immunity
Preset counters electronic
2 presets, totalizer and batch counter Display LED, 5-digits, programmable
NE216
Part number NE216. AX01 Voltage supply 1 22...50 VAC 2 85...265 VAC 3 12...30 VDC Outputs 1 Relay outputs 2 Electronic outputs Interface 0 Without interface 1 RS485 Accessories Adaptor plates (page %S) Z 118.033 Z 118.034 Z 118.035 Adaptor plate for screw mount, face 60 x 75 mm Adaptor plate for clip mount, face 53.2 x 53.2 mm Adaptor plate for clip mount, face 60 x 75 mm Block circuit diagram
Voltage supply + Signal input A B Control input 1 2 7 8 9 10 A 90° B Main counter with 2 presets start count scaling factor Operating time meter Interface RS485 Output 3 4 5 6 P1 1 2 Totalizer 12 13 Sensor supply + -
P2
T,R- 14 T,R+ 15
Trigger level Comparator inputs Inputs Input level Input level Low Input level High Input resistance Relay outputs Switching voltage max. Switching current max. Switching capacity max. Relay responding time Input circuit PNP- / NPN- / AC-logic Programmable 0...2 VDC 3...40 VDC 3 kΩ Output circuit 250 VAC / 110 VDC 1A 150 VA / 30 W 5 ms Output circuit Optocoupler short-circuit proof 40 V 25 mA
Subject to modification in technic and design. Errors and omissions excepted.
Connection diagram Relay outputs
15 14 13 12 11 10 9 8 7
Electronic outputs
15 14 13 12 11 10 9 8 7
Electronical outputs Switching voltage max. Switching current max.
B A
+24V
+24V
T,R+
T,R+
T,R-
T,R-
0V
0V
B
A
3
2
1
3
2
1
RS485 Sensor- Control supply input
Signal input
RS485 Sensor supply
Control input
Signal input
Residual voltage