CPC1964G
AC Power Switch
INTEGRATED CIRCUITS DIVISION
Parameter
AC Operating Voltage
Load Current
On-State Voltage Drop
Blocking Voltage
Rating
20 - 280
1
1.4
800
Units
Vrms
Arms
VP (at IL = 1AP)
VP
Features
•
•
•
•
•
•
•
•
•
•
•
Load Current up to 1Arms
800VP Blocking Voltage
5mA Sensitivity
2500Vrms Input to Output Isolation
Off-State dV/dt: 1000V/Ps Minimum
Zero-Cross Switching
DC Control, AC Output
Optically Isolated
TTL and CMOS Compatible
Low EMI and RFI Generation
High Noise Immunity
Applications
•
•
•
•
•
•
•
•
•
•
•
•
Description
CPC1964G is an AC Solid State Switch utilizing
dual power SCR outputs. This device also includes
zero-cross turn-on circuitry and is specified with a
blocking voltage of 800VP .
In addition, the tightly controlled zero-cross circuitry
ensures low noise switching of AC loads by minimizing
the generation of transients. The optically coupled
input and output circuits provide 2500Vrms of isolation
between the control and load circuits. As a result, the
CPC1964G is well suited for industrial environments
where electromagnetic interference would disrupt the
operation of plant facility communication and control
systems.
Approvals
• UL 508 Certified Component: File E69938
Ordering Information
Lighting
Programmable Control
Process Control
Power Control Panels
Remote Switching
Gas Pump Electronics
Contactors
Large Relays
Solenoids
Motors
Heaters
Meters
Part #
CPC1964G
Description
4-Pin (16-Pin Body) DIP (25/Tube)
Switching Characteristics
Control
AC Line
Pin Configuration
1
16
– LED
+ LED
Load
Current
Voltage
Across
Relay
ZC
10
AC Load
8
AC Load
DS-CPC1964G-R01
www.ixysic.com
1
INTEGRATED CIRCUITS DIVISION
CPC1964G
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage (VDRM)
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage Input to Output
ESD, Human Body Model
i2t for Fusing (1/2 Sine Wave, 50Hz)
Operational Temperature
Storage Temperature
1
Derate linearly 1.33 mW / ºC
2
Derate linearly 16.67 mW / ºC
Ratings
800
5
50
1
150
1600
2500
4
1
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
mW
Vrms
kV
A2s
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25ºC
Parameters
Output Characteristics
Load Current, Continuous
Maximum Surge Current
Off State Leakage Current
On-State Voltage Drop 1
Off-State dV/dt
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage 2
Holding Current
Latching Current
Operating Frequency
Load Power Factor for
Guaranteed Turn-On 3
Input Characteristics
Input Control Current to Activate 4
Input Drop-out Voltage to Deactivate
Input Voltage Drop
Reverse Input Current
Common Characteristics
Input to Output Capacitance
Conditions
Symbol
Min
Typ
Max
Units
VL=120-280Vrms
t < 20ms
IF=0mA, VL=VDRM
IF=5mA, IL=1.5AP
IF=0mA
IL
IP
0.1
1000
1.21
-
1
10
100
1.4
-
Arms
AP
PAP
VP
V/Ps
ton
toff
IH
IL
20
5
-
0.5
0.5
20
5
75
75
500
cycles
cycles
V
V
mA
mA
Hz
f=60Hz
PF
0.25
-
-
-
f=60Hz, IL=1A Resistive
IF=5mA
VR=5V
IF
VF
IR
0.8
0.9
-
1.2
-
5
1.4
10
mA
V
V
PA
VIO=0V, f=1MHz
CIO
-
-
3
pF
IF = 5 mA
1st half cycle
Subsequent half cycle
-
ILEAK
dV/dt
1
Tested at a peak value equivalent.
2 Zero Cross 1st half cycle @ 10mA.
F
2
www.ixysic.com
R01
INTEGRATED CIRCUITS DIVISION
CPC1964G
PERFORMANCE DATA* (@25ºC Unless Otherwise Noted)
Typical LED Forward Voltage Drop
(N=50, IF=5mA)
35
30
30
30
20
15
10
Device Count (N)
25
20
15
10
5
5
0
1.26
1.27
1.28
1.29
LED Forward Voltage (V)
20
15
10
0
1.30
0.6
0.8
1.0
1.2
1.4
LED Current (mA)
1.6
First Zero-Cross Turn-On Voltage
Distribution
(N=50, IF=5mA)
1.200 1.205 1.210 1.215 1.220 1.225 1.230
Forward Voltage (VP)
1.8
Typical Blocking Voltage Distribution
(N=50)
35
30
20
Device Count (N)
Device Count (N)
25
25
5
0
1.25
On-State Forward Voltage Drop
(N=50, IF=5mA, IL=1.5A)
35
25
Device Count (N)
Device Count (N)
Typical IF for Switch Operation
Resistive Load
(N=50, IL=1.5A, VL=120VAC/60Hz)
15
10
5
25
20
15
10
5
0
4.5
5.0
5.5 6.0 6.5 7.0 7.5
Zero-Cross Voltage (V)
Typical LED Forward Voltage Drop
vs. Temperature
850
865
880
895
910
Blocking Voltage (VP)
First Zero-Cross Turn-On Voltage
(IF=5mA, RL=120:)
8.5
1.3
IF=50mA
IF=20mA
IF=10mA
IF=5mA
1.1
-20
0
20
40
60
Temperature (ºC)
80
Forward Current (mA)
3.0
2.6
2.4
2.2
2.0
-20
0
20
40
60
Temperature (ºC)
80
100
70
60
50
40
30
20
-40
100
2.8
-40
7.0
6.5
LED Forward Current to Operate
vs. Temperature - Resistive Load
(IL=350mA, 60Hz)
3.0
7.5
-20
0
20
40
60
Temperature (ºC)
80
100
-20
0
20
40
60
Temperature (ºC)
80
100
LED Forward Current to Operate
vs.Load Frequency
(VP=67V, RL=50:, IL=0.94Arms)
LED Forward Current to Operate
vs. Temperature - Inductive Load
(IL=500mA, 60Hz, 200mH)
3.2
2.8
2.6
2.4
2.2
2.0
-40
-40
Forward Current (mA)
1.2
8.0
925
Holding Current vs. Temperature
(RL=1.9:)
80
Holding Current (mA)
1.4
1.0
-40
Forward Current (mA)
0
1.5
Zero-Cross (V)
LED Forward Voltage (V)
1.6
8.0
3.0
2.8
2.6
2.4
2.2
2.0
-20
0
20
40
60
Temperature (ºC)
80
100
0
100
200
300
400
Load Frequency (Hz)
500
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
R01
www.ixysic.com
3
INTEGRATED CIRCUITS DIVISION
CPC1964G
PERFORMANCE DATA* (@25ºC Unless Otherwise Noted)
Load Current vs. Load Voltage
(IF=5mA)
On-State Voltage vs. Temperature
3
1.30
1.25
Von@1AP
1.10
1.05
Von@0.5AP
1.00
Load Current (A)
1.15
1
0
-1
-2
0.95
-3
-1.5
0.90
-40
-20
0
20
40
60
Temperature (ºC)
80
100
Maximum Load Current
vs. Temperature
(IF=5mA)
-0.5
0.0
0.5
Voltage (V)
1.0
1.5
0.75
0.50
1000
950
900
850
0.25
-40
-20
0
20
40
60
Temperature (ºC)
80
-40
100
-1.0
-0.5
0.0
0.5
Load Voltage (V)
1.0
1.5
80
100
10
1050
1.00
-40ºC
25ºC
85ºC
Typical Leakage Current
vs. Temperature
Blocking Voltage vs. Temperature
Blocking Voltage (VP)
1.25
-1.0
Leakage Current (PA)
Von (VP)
Von@1.5AP
Current (A)
2
1.20
Load Current (Arms)
Typical Load Current vs. Load Voltage
2.5
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
-2.5
-1.5
-20
0
20
40
60
Temperature (ºC)
80
100
VL=800V
VL=300V
1
0.1
0.01
0.001
-40
-20
0
20
40
60
Temperature (ºC)
Maximum Surge Current vs. Time
Load Current (Apeak)
12
10
8
6
4
2
0
100Ps
1ms
10ms 100ms
Time
1s
10s
100s
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
4
www.ixysic.com
R01
INTEGRATED CIRCUITS DIVISION
CPC1964G
Manufacturing Information
Moisture Sensitivity
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated
Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to
the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product
evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper
operation of our devices when handled according to the limitations and information in that standard as well as to any
limitations set forth in the information or standards referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced
product performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according
to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
Device
Moisture Sensitivity Level (MSL) Rating
CPC1964G
MSL 1
ESD Sensitivity
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Soldering Profile
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020
must be observed.
Device
Maximum Temperature x Time
CPC1964G
245ºC for 30 seconds
Board Wash
IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to
remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as
an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary
if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used.
Cleaning methods that employ ultrasonic energy should not be used.
R01
www.ixysic.com
5
INTEGRATED CIRCUITS DIVISION
CPC1964G
Mechanical Dimensions
CPC1964G
7.620 ± 0.254
(0.300 ± 0.010)
19.202 ± 0.381
(0.756 ± 0.015)
0.254 TYP
(0.010 TYP)
PCB Hole Pattern
0.800 DIA x 4
(0.031 DIA x 4)
Pin 16
6.350 ± 0.127
(0.250 ± 0.005)
Pin 1
Pin 16
7.620
(0.300)
17.780 ± 0.127
(0.700 ± 0.005)
15.240 ± 0.127
(0.600 ± 0.005)
3.302 ± 0.051
(0.130 ± 0.002)
9.144 ± 0.508
(0.360 ± 0.020)
7.239 TYP
(0.285 TYP)
Pin 1
2.540 ± 0.127
(0.100 ± 0.005)
15.240
(0.600)
17.780
(0.700)
4.064 TYP
(0.160 TYP)
0.559 ± 0.102
(0.022 ± 0.004)
0.457 ± 0.076
(0.018 ± 0.003)
Dimensions
mm
(inches)
For additional information please visit our website at: www.ixysic.com
IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make
changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated
Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its
products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe
property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice.
6
Specification: DS-CPC1964G-R01
©Copyright 2014, IXYS Integrated Circuits Division
All rights reserved. Printed in USA.
9/24/2014