0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CPC1976Y

CPC1976Y

  • 厂商:

    IXYS(艾赛斯)

  • 封装:

    SIP8_4Pin

  • 描述:

    RELAY 240VAC 2A POWER 8-SIP

  • 数据手册
  • 价格&库存
CPC1976Y 数据手册
CPC1976 AC Power Switch INTEGRATED CIRCUITS DIVISION Parameter AC Operating Voltage Load Current On-State Voltage Drop Blocking Voltage Rating 20 - 240 2 1.15 600 Units Vrms Arms Vrms (at IL = 2Arms) VP Features • • • • • • • • • • Load Current up to 2Arms 600VP Blocking Voltage 5mA Sensitivity Zero-Crossing Detection DC Control, AC Output Optically Isolated TTL and CMOS Compatible Low EMI and RFI Generation High Noise Immunity Machine Insertable, Wave Solderable Applications • • • • • • • • • • Programmable Control Process Control Power Control Panels Remote Switching Gas Pump Electronics Contactors Large Relays Solenoids Motors Heaters Description CPC1976 is an AC Solid State Switch utilizing dual power SCR thyristor outputs. This device also includes zero-cross turn-on circuitry and is specified with a blocking voltage of 600VP . In addition, tightly controlled zero-cross circuitry ensures low noise switching of AC loads by minimizing the generation of transients. The optically coupled input and output circuits provide 3750Vrms of isolation and noise immunity between the control and load circuits. As a result, the CPC1976 is well suited for industrial environments where electromagnetic interference would disrupt the operation of plant facility communication and control systems. Approvals • UL Recognized Component: File E69938 • CSA Certified Component: File 043639 Ordering Information Part # CPC1976Y Description 4-Pin (8-Pin Body) SIP (25/Tube) Pin Configuration ZC 1 2 – LED + LED 3 4 AC Load AC Load Zero-Cross Waveforms Control AC Line Load Current Voltage Across Relay DS-CPC1976-R05 www.ixysic.com 1 INTEGRATED CIRCUITS DIVISION CPC1976 Absolute Maximum Ratings @ 25ºC Parameter Blocking Voltage (VDRM) Reverse Input Voltage Input Control Current Peak (10ms) Input Power Dissipation 1 Total Power Dissipation 2 Isolation Voltage, Input to Output ESD, Human Body Model i2t for Fusing (1/2 Sine Wave, 50Hz) Operational Temperature Storage Temperature 1 Derate linearly 1.33 mW / ºC 2 Derate linearly 20 mW / ºC Ratings 600 5 50 1 150 2400 3750 4 8 -40 to +85 -40 to +125 Units VP V mA A mW mW Vrms kV A2s °C °C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Electrical Characteristics @ 25ºC Parameters Output Characteristics Load Current, Continuous Maximum Surge Current Off State Leakage Current On-State Voltage Drop Critical Rate of Rise Switching Speeds Turn-on Turn-off Zero-Cross Turn-On Voltage 1 Holding Current Latching Current Operating Frequency Load Power Factor for Guaranteed Turn-On 2 Input Characteristics Input Control Current to Activate 3 Input Drop-out Voltage Input Voltage Drop Reverse Input Current Common Characteristics Input to Output Capacitance 1 2 3 2 Conditions Symbol Min Typ Max Units VL=120-240Vrms t < 16ms VDRM IL=2AP - IL IPK 0.070 1000 1.1 1200 2 20 10 1.25 - Arms A A VP V/s ton toff IH IL 20 7 - 0.5 0.5 20 5 75 100 500 cycles cycles V V mA mA Hz 60Hz PF 0.25 - - - 60Hz IF=5mA VR=5V IF VF IR 0.8 0.9 - 1.2 - 5 1.4 10 mA V V A - CI/O - - 3 pF IF = 5 mA 1st half-cycle Subsequent half-cycle - ILEAK dv/dt Zero Cross 1st half-cycle @ 10mA. www.ixysic.com R05 INTEGRATED CIRCUITS DIVISION CPC1976 PERFORMANCE DATA @ 25ºC (Unless Otherwise Noted)* LED Forward Voltage Distribution (N=50, IF=5mA) 35 30 20 15 10 Device Count (N) 25 20 15 10 1.26 1.27 1.28 1.29 LED Forward Voltage (V) Device Count (N) 25 1.5 1.30 1.7 1.9 2.1 2.3 LED Current (mA) On-State Voltage Drop Distribution (N=50, IF=5mA, IL=2AP) 5 20 15 10 5 0 2.5 6.2 2.7 1.06 1.08 1.10 1.12 On-State Voltage Drop (V) 15 10 5 IF=50mA IF=20mA IF=10mA IF=5mA 1.5 1.4 1.14 874 876 878 880 882 884 Blocking Voltage (VP) 1.3 1.2 2.6 2.5 Zero-Cross Voltage (V) LED Current to Operate (mA) 1.6 2.4 2.3 2.2 2.1 2.0 1.9 1.8 1.1 20 40 60 Temperature (ºC) 80 -40 100 LED Current to Operate (Resistive) vs. Load Frequency (VP=30V, RL=10:, IL=20Arms) 3.0 LED Current (mA) 2.9 2.8 2.7 2.6 2.5 2.4 2.3 400 LED Current to Operate (Inductive) vs. Load Frequency (VL=200V, ZL=400mH, 220:) 3.0 2.8 2.6 2.5 2.4 2.3 886 Zero-Cross Voltage vs. Temperature (IF=5mA, RL=120:) -40 100 2.7 2.1 350 80 2.9 2.1 150 200 250 300 Load Frequency (Hz) 20 40 60 Temperature (ºC) 2.8 2.2 100 0 10 9 8 7 6 5 4 3 2 1 0 2.9 2.2 50 -20 LED Current (mA) 0 7.4 20 LED Current to Operate vs. Temperature (Resistive Load) (IL=1A, f=60Hz) LED Forward Voltage vs. Temperature -20 6.6 6.8 7.0 7.2 Zero-Cross Voltage (V) 0 1.04 -40 6.4 Blocking Voltage Distribution (N=50) Device Count (N) 1.25 LED Forward Voltage (V) 10 0 0 0 LED Current (mA) 15 5 5 3.0 Zero-Cross Voltage Distribution 20 25 Device Count (N) Device Count (N) 30 LED Current to Operate Distribution (N=50, VL=120VAC/60Hz) -20 0 20 40 60 Temperature (ºC) 80 100 LED Current to Operate (Inductive) vs. Load Frequency (VL=200V, ZL=196mH, 110:) 2.7 2.6 2.5 2.4 2.3 2.2 2.1 50 100 150 200 250 300 Load Frequency (Hz) 350 400 50 100 150 200 250 300 Load Frequency (Hz) 350 400 * The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R05 www.ixysic.com 3 INTEGRATED CIRCUITS DIVISION CPC1976 100 90 80 70 60 50 40 30 20 10 0 1.2 0 20 40 60 Temperature (ºC) 80 1.0 0.9 100 IL=2.5A IL=2A IL=1A IL=0.5A -40 Maximum Load Current vs. Temperature (IF=5mA) 2.5 -20 0 20 40 60 Temperature (ºC) 80 1.0 0.5 0.0 80 2.0 Leakage Current vs. Temperature 950 900 850 100 1.5 10000 VL=600V VL=400V VL=200V 1000 100 10 1 0.1 800 20 40 60 Temperature (ºC) -3 -2.0 -1.5 -1.0 -0.5 0.0 0.5 1.0 Load Voltage (V) 100 Leakage Current (PA) Blocking Voltage (VP) 1.5 0 0 -1 Blocking Voltage vs. Temperature 2.0 -20 1 -2 1000 -40 TA=+85ºC TA=+25ºC TA= -40ºC 2 1.1 0.7 -20 Load Current vs. Load Voltage (IF=5mA) 3 0.8 -40 Load Current (Arms) Load Voltage vs. Temperature (IF=5mA) Load Current (A) Holding Current vs. Temperature (RL=1.9:) Load Voltage (V) Holding Current (mA) PERFORMANCE DATA @ 25ºC (Unless Otherwise Noted)* -40 -20 0 20 40 60 Temperature (ºC) 80 100 -40 -20 0 20 40 60 Temperature (ºC) 80 100 Maximum Non-Repetitive Surge Current (Values Apply to TJ=50ºC Before Surge) Load Current (AP) 25 20 15 10 5 0 0.1 1 10 Time (ms) 100 1000 * The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.ixysic.com R05 INTEGRATED CIRCUITS DIVISION CPC1976 Manufacturing Information Moisture Sensitivity All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according to the limitations and information in that standard as well as to any limitations set forth in the information or standards referenced below. Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced product performance, reduction of operable life, and/or reduction of overall reliability. This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033. Device Moisture Sensitivity Level (MSL) Rating CPC1976Y MSL 1 ESD Sensitivity This product is ESD Sensitive, and should be handled according to the industry standard JESD-625. Reflow Profile This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020 must be observed. Device Maximum Temperature x Time CPC1976Y 245ºC for 30 seconds Board Wash IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be used. R05 www.ixysic.com 5 INTEGRATED CIRCUITS DIVISION CPC1976 MECHANICAL DIMENSIONS CPC1976Y 21.082±0.381 (0.830±0.015) PCB Hole Pattern 3.302±0.051 (0.130±0.002) 10.160±0.127 (0.400±0.005) 1.75 (0.069) 7º TYP 4 Places Pin 1 1.778 (0.070) 0.762±0.076 (0.030±0.003) 2.540±0.127 (0.100±0.005) 4.572±0.127 (0.180±0.005) 10.160±0.127 (0.400±0.005) 5.080±0.127 (0.200±0.005) 1.651±0.102 (0.065±0.004) 5.080 (0.200) 10.160 (0.400) 1.016±0.127 (0.040±0.005) Pin 1 1.150 DIA. x4 (0.045 DIA. x4) 0.381±0.013 (0.015±0.0005) 2.540 (0.100) 1.778 (0.070) 7º TYP 4 Places Dimensions mm (inches) For additional information please visit our website at: www.ixysic.com IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice. 6 Specification: DS-CPC1976-R05 ©Copyright 2013, IXYS Integrated Circuits Division All rights reserved. Printed in USA. 10/21/2013
CPC1976Y 价格&库存

很抱歉,暂时无法提供与“CPC1976Y”相匹配的价格&库存,您可以联系我们找货

免费人工找货
CPC1976Y
    •  国内价格
    • 1+65.95944
    • 6+30.79274
    • 12+27.46852

    库存:0