CYG2011

CYG2011

  • 厂商:

    IXYS(艾赛斯)

  • 封装:

    18-DIP模块(0.850",21.59mm),11引线

  • 描述:

    IC MOD DAA FULL-WAVE LOOP PCB

  • 数据手册
  • 价格&库存
CYG2011 数据手册
CYG20XX CybergateTM Description The CYG2000/2001/2010/2011/2020/2021/2030/2031 are Data Access Arrangement (DAA) modules featuring a 350V, 120mA, 15Ω relay used for hookswitch, optocoupler with minimum CTR of 33% for ring detection, and a low distortion transformer with 28.8kbps capabilities. Features • Low distortion transformer signal coupling (0.01% max) • Complete ring detector circuit • Low power hookswitch • Electronic inductor/gyrator circuit • Surge protection • Transient protection zeners • Half- (20X0) or Full- (20X1) Wave Detection • V.32 bis /V.34 compatible • FCC Compatible • Compatible with U.S. and Canadian dial up phone lines • Supports leased-line operation • PC board mountable Approvals • UL recognized file #: E174201 Ordering Information Part # CYG2000 CYG2001 CYG2010 Applications • Modems • Fax machines • Remote data acquisition • Security systems • Voice mail systems • PC motherboard • Computer telephony • Process control • Medical • PBX • Direct broadcast satellite Description DAA Module, Half Wave Ring Detection DAA Module, Full Wave Ring Detection DAA Module, Half Wave Ring Detection, Loop Current Detection DAA Module, Full Wave Ring Detection Loop Current Detection DAA Module, Half Wave Ring Detection, CID DAA Module, Full Wave Ring Detection, CID DAA Module, Half Wave Ring Detection, CID and Loop Current Detection DAA Module, Full Wave Ring Detection, CID and Loop Current Detection CYG2011 CYG2020 CYG2021 CYG2030 CYG2031 Block Diagrams CYG2010/CYG2011 LINE 1 LINE 2 1 RING 2 R_LIM VCC 18 470Ω GND 17 GYRATOR VCC LINE 1 GND LINE 2 OH RING 7 8 9 RING R_LIM 1 470Ω VCC 2 GYRATOR/ CALLER ID HOOKSWITCH LOOPI VCC VCC VCC 47k 18 17 14 HOOKSWITCH 13 LOOP CURRENT R_LIM DETECT 2.2k CYG2030/CYG2031 CYG2020/CYG2021 RING SURGE DETEC- PROTECTION TION 11 10 RING TIP RING OH RING RING SURGE DETEC- PROTECTION TION R_LIM 8 9 47k VCC RING VCC LINE 1 GND LINE 2 11 RING 470Ω VCC RING OH 8 RING 9 17 13 LOOP CURRENT DETECT 7 18 14 HOOKSWITCH CID2 TIP R_LIM GYRATOR/ CALLER ID CID1 LOOPI 10 1 2 R_LIM 2.2k VCC 47k VCC RING SURGE DETEC- PROTECTION TION RING 11 10 VCC GND CID1 CID2 TIP RING Handling and Assembly Recommendations The CYG20XX products are not hermetically sealed and should not be exposed to any liquid-based rinsing processes. Clare recommends two (2) approaches. The modem should either use a no clean soldering flux that would mostly evaporate during the normal wave soldering processes, or be soldered in by hand after the rest of the card is wave soldered. DS-CYG20XX-R1 www.clare.com 1 CYG20XX Absolute Maximum Ratings (@ 25˚ C) Parameter Min Isolation Voltage Operational Temperature Storage Temperature Relative Humidity (Non-Condensing) Soldering Temperature Tip/Ring (5, 6) Load current (continuous) Hookswitch LED Drive Current Hookswitch LED Reverse Voltage Ring Detect Phototransistor Voltage VCC Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure of the device to the absolute maximum ratings for an extended period may degrade the device and effect its reliability. Typ Max Units 0 0 - 1000 VRMS 70 °C 70 °C 10 - - 85 260 % °C - - 120 mA - - 50 mA - - 5 V - - 20 V Electrical Characteristics Parameter Conditions Min Typ Max Unit @100VDC across pins 10,11 (R,T), per FCC 68.312 @100VDC across pins 10,11 (R,T), per FCC 68.312 @+5V, VCC - 10 - - MΩ - - 10 µA 7 4.75 20 8 5.0 - 15 9 20 120 Ω mA V mA DC Electrical Characteristics On-Hook Impedance Off-Hook Line Leakage Current Hookswitch Resistance Off-Hook Supply Current Hookswitch Power Source, Pin 8 DC Loop Current AC Signal Path Electrical Characteristics Return Loss Insertion Loss Transmit Receive Frequency Response Longitudinal Balance On-Hook Off-Hook DC Loop Current Total Harmonic Distortion Secondary Load Impedance Primary Source Impedance Ring Detection Circuit Characteristics Ringing Voltage Detection Range Ringing Frequency Detection Range Ringer Equivalence Number RING (Pin 9) Output Voltage (Pulsed) Logic ‘0’, Ring present Logic ‘1’, Ring not present 2 300-3500Hz 300-3500Hz Test Circuit 1 Test Circuit 2 300-3500Hz 18 25 - dB -0.25 - 7 7 +0.25 dB dB dB Per FCC 68.310 Per FCC 68.310 @600Hz and -10dBm Line 1 and Line 2 Tip and Ring 60 40 20 - 294 600 120 0.01 - dB dB mA % Ω Ω VCC @+5V 20 15 - 0.8B 150 70 - Vrms Hz - - 0.8 Vcc V V www.clare.com Rev. 1 CYG20XX Electrical Characteristics (Continued) Parameter Surge, Transient, and Isolation Characteristics Surge Protection Voltage Tip and Ring (Pins 11,10) Transient Voltage Protection on Line 1 and Line 2 (Pins 1,2) Isolation Voltage (Pins 1,2,7,8,9,17,18 to10,11,13,14) Loop Detection Characteristics (CYG2010/CYG2011/CYG2030/CYG2031) Loop Current Detection Threshold Conditions Min Typ Max Unit - - - 300 V - -5 - +5 V Per FCC 68.302 - - 1000 VRMS Internal optocoupler with 2.2K Pull-up resistor 9 10 11 mA Test Circuits 1. CYG20XX Transmit Insertion Loss 2. CYG20XX Receive Insertion Loss +5V +5V VT Rm 294Ω LINE1 VCC LINE2 GND LOOP OH ILOOP CID1 CID2 LINE1 LINE2 VCC +VBATT GND ILOOP CID1 10H OH TIP TIP 600Ω VLR 600Ω RING RING RING VLT VT AC Source 10H 10H Transmit Insertion Loss = GTR = 20 Log 10H CID2 VLT RING VR Rm 294Ω +VBATT Receive Insertion Loss = G RC = 20 Log -VBATT VR V LR -VBATT CYG2020/2021/2030/2031 Caller ID Connections Pins 13 & 14 should be connected to a 1-Form-A solid state relay (Clare LCA110), as follows: VCC 1 µP Control (Active Low) 6 4 Rev. 1 CID1 2 www.clare.com CID2 3 CYG20XX Package Pinouts CYG2000/CYG2001 CYG2010/CYG2011 LINE 1 LINE 2 1 2 18 17 VCC GND LINE 1 LINE 2 1 2 18 17 VCC GND DO NOT USE OH RING 7 8 9 11 10 TIP RING LOOPI OH RING 7 8 9 11 10 TIP RING LINE 1 LINE 2 OH RING Top View Top View CYG2020/CYG2021 CYG2030/CYG2031 1 2 8 9 18 17 VCC GND 14 13 CID1 CID2 11 10 TIP RING LINE 1 LINE 2 LOOPI OH RING 1 2 7 8 9 Top View 18 17 VCC GND 14 13 CID1 CID2 11 10 TIP RING Top View CYG20XX Pinouts & Definitions 4 PIN# I/O Name Function 1 I/O LINE1 Transformer isolated audio signal coupling path for the telephone line. 2 I/O LINE2 Transformer isolated audio signal coupling path for the telephone line. 7 I LOOPI When system is off-hook (OH driven LOW) LOOPI is driven LOW continuously on CYG2010/2011/2030/2031 devices. N/C Keying pin for CYG2000/CYG2001, do not use. 8 I OH Driving this pin LOW asserts the off-hook condition. The hookswitch LED is current limited by an internal 470Ω resistor. 9 O RING Active LOW indicates an incoming ring signal. This is pulsed LOW by the AC ring signal at the ring frequency from 15-40Hz. 10 I/O RING Connection to telephone line Ring conductor. 11 I/O TIP 13 O CID2 Caller ID connection on CYG2020/2021/2030/2031. CID1/CID2 connect to an external 1-Form-A solid state relay (CP Clare LCA110). When the SSR is closed (connecting CID1 to CID2) Caller ID information is presented to LINE1/LINE2 after the first telephone ring burst. 14 O CID1 Caller ID connection. See CID2 above. 17 I GND Connected to host system ground. 18 I VCC Provides power to the hookswitch LED. Typically +5V for ≈ 8mA LED current. LED is current limited by an internal 470Ω resistor. VCC should not exceed 20V. Connection to telephone line Tip conductor. www.clare.com Rev. 1 CYG20XX Typical Application CYG2000/CYG2001 +5V 294Ω TX1 LINE 1 18 VCC VCC 1 10 RING HYBRID CIRCUIT TX2 LINE 2 2 HOOKSWITCH VCC RING DETECT NETWORK RX OH RELAY GND RING OH RING 8 9 TO TELEPHONE LINE 11 470Ω TIP 17 56kΩ Rev. 1 SURGE PROTECTOR GYRATOR www.clare.com VCC GND 5 For additional information please visit our website at: www.clare.com Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. Specification: DS-CYG20XX-R1.0 ©Copyright 2002, Clare, Inc. All rights reserved. Printed in USA. 6/25/02
CYG2011 价格&库存

很抱歉,暂时无法提供与“CYG2011”相匹配的价格&库存,您可以联系我们找货

免费人工找货
CYG2011
  •  国内价格
  • 1+89.23629

库存:0