CPC1943
Optically Coupled
AC Power Switch
INTEGRATED CIRCUITS DIVISION
Parameter
Blocking Voltage
Load Current
On State Voltage Drop
Rating
400
500
1.4
Features
• Load Current up to 0.5Arms
• 400VP Blocking Voltage
• 5mA Sensitivity
• Zero-Crossing Detection
• DC Control, AC Output
• Optically Isolated
• Low EMI and RFI Generation
• High Noise Immunity
• Flammability Rating UL 94 V-0
Applications
• Programmable Control
• Process Control
• Power Control Panels
• Remote Switching
• Gas Pump Electronics
• Contactors
• Large Relays
• Solenoids
• Motors
• Heaters
Units
VP
mArms
Vrms (at IL = 500mArms)
Description
The CPC1943 is an AC Solid State Switch using
optical coupling with dual power SCR outputs to
produce an alternative to optocoupler and Triac
circuits. The CPC1943 switches are robust enough to
provide a blocking voltage of up to 400VP .
In addition, tightly controlled zero cross circuitry
ensures switching of AC loads without the generation
of transients.
The input and output circuits are optically coupled
to provide 3750Vrms of isolation and noise immunity
between control and load circuits. As a result the
CPC1943 is well suited for industrial environments
where electromagnetic interference could disrupt the
operation of electromechanical relays.
Approvals
• UL 508 Certified Component: File E69938
• CSA Certified Component: File 043639
Ordering Information
Part #
CPC1943G
CPC1943GS
CPC1943GSTR
Description
6-Pin Dip (50/Tube)
6-Pin Surface Mount (50/Tube)
6-Pin Surface Mount (1000/Reel)
Pin Configuration
1
6
+ LED
- LED
2
3
DS-CPC1943-R09
www.ixysic.com
ZC
5
AC Load
AC Load
4
1
INTEGRATED CIRCUITS DIVISION
CPC1943
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation1
PMAX , Total Package Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
Ratings Units
400
VP
5
V
100
mA
1
A
150
mW
800
mW
3750
Vrms
-40 to +85
°C
-40 to +125
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Typical values are characteristic of the device at +25°C,
and are the result of engineering evaluations. They are
provided for information purposes only, and are not part of
the manufacturing testing requirements.
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Electrical Characteristics @ 25ºC
Parameters
Output Characteristics
Operating Voltage Range
Load Current, Continuous
Off State Leakage Current
On-State Voltage Drop
Critical Rate of Rise 3
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage 1
Operating Frequency
Load Power Factor for Guaranteed Turn-On 2
Input Characteristics
Input Control Current to Activate 4
Input Voltage Drop
Input Drop-out Voltage
Reverse Input Current
Common Characteristics
Input to Output Capacitance
Conditions
Symbol
Min
Typ
Max
Units
VL
VL=120-240Vrms
VL=400VP
IL=500mArms
-
IL
20
0.005
1000
-
120
0.5
1
1.4
-
Vrms
Arms
mA
Vrms
V/µs
20
0.25
2
1
-
0.5
0.5
10
500
-
0.8
1.2
-
5
1.5
10
mA
V
V
µA
3
-
pF
IF=5 mA
1st half cycle
Subsequent half cycle
-
ILEAK
VON
dV/dt
ton
toff
PF
IF=5mA
VR=5V
IF
VF
IR
0.9
0.8
-
VIO=0V, f=1MHz
CIO
-
cycles
V
V
Hz
-
1
Zero Cross 1st half cycle @
很抱歉,暂时无法提供与“CPC1943G”相匹配的价格&库存,您可以联系我们找货