CPC1964BX6
Rapid Turn-On
AC Power Switch
INTEGRATED CIRCUITS DIVISION
Parameter
AC Operating Voltage
Load Current
On-State Voltage Drop
Blocking Voltage
Rating
20 - 240
1.5
1.4
600
Units
Vrms
Arms
VP (at IL = 1.5AP)
VP
Load Current up to 1.5Arms
600VP Blocking Voltage
High Surge Current: 15A
Rapid Turn-On (Non-Zero-Cross Turn-On)
5mA Sensitivity
Creepage Distance: 0.220" on Output Pins
12.5mm External Creepage Distance
DC Control, AC Output
Optically Isolated
Low EMI and RFI Generation
High Noise Immunity
Flammability Rating UL 94 V-0
Approvals
• UL Recognized Component: File E69938
• CSA Certified Component: Certificate 1172007
Ordering Information
Part #
CPC1964BX6
Applications
•
•
•
•
•
•
•
•
•
•
•
•
•
CPC1964BX6 is an AC Solid State Switch utilizing
dual power SCR outputs. This device features Rapid
Turn-On (non-zero-cross) control of the output SCRs,
which makes it ideal for precisely switching AC loads
independent of the load voltage phase.
The optically coupled input and output circuits
provide 5000Vrms of isolation and noise immunity
between the control and load circuits. As a result, the
CPC1964BX6 is well suited for industrial environments
where electromagnetic interference would disrupt the
operation of plant facility communication and control
systems.
Features
•
•
•
•
•
•
•
•
•
•
•
•
Description
HVAC Control (Heating, Ventilation, Air Conditioning)
Lighting
Programmable Control
Process Control
Power Control Panels
Remote Switching
Gas Pump Electronics
Contactors
Large Relays
Solenoids
Motors
Heaters
Meters
Description
8-Pin Power SOIC (25/Tube)
Pin Configuration
8
AC Load
7
6
AC Load
5
R
1
N/C
2
+ LED
3
– LED
4
N/C
Rapid Turn-On (Non Zero-Cross) Waveforms
Control
AC Load
Voltage
Load
Current
Voltage
Across
Relay
DS-CPC1964BX6-R02
www.ixysic.com
1
INTEGRATED CIRCUITS DIVISION
CPC1964BX6
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage (VDRM)
Reverse Input Voltage
Input Control Current
Peak (10ms)
di/dt Critical Rate of Rise
of On-State Current
Input Power Dissipation 1
Total Power Dissipation 2
ESD, Human Body Model
i2t Fusing Current (1/2 Sine Wave, 60Hz)
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1
Derate linearly 1.33 mW / ºC
2
Derate linearly 20 mW / ºC
Ratings
600
5
50
1
Units
VP
V
mA
A
20
A/s
150
2400
4
2
5000
-40 to +85
-40 to +125
mW
mW
kV
A2s
Vrms
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to the
device. Functional operation of the device at conditions beyond
those indicated in the operational sections of this data sheet is
not implied.
Typical values are characteristic of the device at +25°C, and
are the result of engineering evaluations. They are provided for
information purposes only, and are not part of the manufacturing
testing requirements.
Electrical Characteristics @ 25ºC
Parameters
Output Characteristics
Load Current, Continuous
Maximum Surge Current
Off State Leakage Current
On-State Voltage Drop
Off-State dV/dt
Switching Speeds
Turn-on
Turn-off
Holding Current
Latching Current
Operating Frequency
Input Characteristics
Input Control Current to Activate 1
Input Drop-out Voltage
Input Voltage Drop
Reverse Input Current
Common Characteristics
Input to Output Capacitance
1
2
Conditions
Symbol
Min
Typ
Max
Units
VL=20-240Vrms
t < 16ms
VDRM
IL=1.5AP
-
IL
IP
0.07
1000
1.21
-
1.5
15
100
1.4
-
Arms
A
AP
VP
V/s
ton
toff
IH
IL
20
20
44
48
-
500
0.5
75
75
500
s
cycles
mA
mA
Hz
60Hz
IF=5mA
VR=5V
IF
VF
IR
0.8
0.9
-
1.2
-
5
1.5
10
mA
V
V
A
VIO=0V, f=1MHz
CIO
-
-
3
pF
IF = 5mA, Resistive
VL=20V, 60Hz
-
ILEAK
dV/dt
For high-noise environments, or for high-frequency operation, use IF > 10mA.
www.ixysic.com
R02
INTEGRATED CIRCUITS DIVISION
CPC1964BX6
PERFORMANCE DATA*
35
30
30
Device Count (N)
30
Device Count (N)
Typical IF for Switch Operation
Resistive Load
(N=50, IL=1.5A, VL=120VAC 60Hz)
On-State Forward Voltage Drop
(N=50, IF=5mA, IL=1.5A)
25
20
15
10
25
Device Count (N)
35
Typical LED Forward Voltage Drop
(N=50, IF=5mA)
25
20
15
10
0
0
1.25
1.26
1.27
1.28
1.29
LED Forward Voltage (V)
15
10
5
5
5
20
0
1.200 1.205 1.210 1.215 1.220 1.225 1.230
Forward Voltage (VP)
1.30
1.5
1.7
1.9
2.1
2.3
LED Current (mA)
2.5
2.7
Typical Blocking Voltage Distribution
(N=50)
Device Count (N)
25
20
15
10
5
0
747
Typical LED Forward Voltage Drop
vs. Temperature
Turn-On Time vs. Temperature
20
IF=5mA
1.3
1.2
Turn-On Time (Ps)
60
Turn-On Time (Ps)
LED Forward Voltage (V)
768
70
IF=50mA
IF=20mA
IF=10mA
IF=5mA
1.4
753 756 759 762 765
Blocking Voltage (VP)
Typical Turn-On Time
vs. LED Forward Current
1.6
1.5
750
50
40
30
20
15
IF=10mA
10
5
10
1.1
0
0
-40
-20
0
20
40
60
Temperature (ºC)
80
100
0
50
-40
-20
0
20
40
60
Temperature (ºC)
80
100
Typical IF for Switch Operation
Resistive Load
(IL=350mA, 60Hz)
2.9
LED Forward Current (mA)
10
20
30
40
LED Forward Current (mA)
2.8
2.7
2.6
2.5
2.4
2.3
2.2
2.1
-40
-20
0
20
40
60
Temperature (ºC)
80
100
*Unless otherwise noted, data presented in these graphs is typical of device operation at 25ºC.
For guaranteed parameters not indicated in the written specifications, please contact our application department.
R02
www.ixysic.com
3
INTEGRATED CIRCUITS DIVISION
CPC1964BX6
PERFORMANCE DATA*
Holding Current
(RL=1.9:)
On-State Voltage vs. Temperature
1.25
60
50
40
30
20
1.20
IL=1.5A
1.15
1.10
IL=1A
1.05
1.00
IL=0.5A
0.95
-40
-20
0
20
40
60
Temperature (ºC)
80
-40
100
Blocking Voltage vs. Temperature
-20
0
20
40
60
Temperature (ºC)
80
100
850
800
750
700
0
20
40
60
Temperature (ºC)
80
900
850
800
750
100
-40
Load Current (AP)
20
-0.5
0.0
0.5
1.0
1.5
10
700
-20
-1.0
Typical Leakage Current
vs. Temperature
Leakage Current (PA)
Blocking Voltage (VP)
900
@ 85ºC
@ 25ºC
@ -40ºC
Load Voltage (V)
950
-40
2.5
2.0
1.5
1.0
0.5
0.0
-0.5
-1.0
-1.5
-2.0
-2.5
-1.5
Blocking Voltage vs. Temperature
950
Blocking Voltage (VP)
Load Current (A)
70
On-State Voltage (VP)
Holding current (mA)
80
Typical Load Current
vs. Load Voltage
(IF=5mA)
-20
0
20
40
60
Temperature (ºC)
80
100
VL=600V
VL=300V
1
0.1
0.01
0.001
-40
-20
0
20
40
60
Temperature (ºC)
80
100
Maximum Surge Current vs. Time
TJ=50ºC Before Surge
15
10
5
0
100Ps
1ms
10ms 100ms
Time
1s
10s
100s
*Unless otherwise noted, data presented in these graphs is typical of device operation at 25ºC.
For guaranteed parameters not indicated in the written specifications, please contact our application department.
4
www.ixysic.com
R02
INTEGRATED CIRCUITS DIVISION
CPC1964BX6
Manufacturing Information
Moisture Sensitivity
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated
Circuits classifies its plastic encapsulated devices for moisture sensitivity according to the latest version of
the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of
our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices
when handled according to the limitations and information in that standard as well as to any limitations set forth in
the information or standards referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced
product performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) classification as shown below, and should be handled
according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
Device
Moisture Sensitivity Level (MSL) Classification
CPC1964BX6
MSL 1
ESD Sensitivity
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Soldering Profile
Provided in the table below is the Classification Temperature (TC) of this product and the maximum dwell time the
body temperature of this device may be (TC - 5)ºC or greater. The classification temperature sets the Maximum
Body Temperature allowed for this device during lead-free reflow processes. For through-hole devices, and any other
processes, the guidelines of J-STD-020 must be observed.
Device
Classification Temperature (Tc)
Dwell Time (tp)
Max Reflow Cycles
CPC1964BX6
245ºC
30 seconds
3
Board Wash
IXYS Integrated Circuits recommends the use of no-clean flux formulations. Board washing to reduce or remove flux
residue following the solder reflow process is acceptable provided proper precautions are taken to prevent damage
to the device. These precautions include, but are not limited to: using a low pressure wash and providing a follow
up bake cycle sufficient to remove any moisture trapped within the device due to the washing process. Due to the
variability of the wash parameters used to clean the board, determination of the bake temperature and duration
necessary to remove the moisture trapped within the package is the responsibility of the user (assembler). Cleaning
or drying methods that employ ultrasonic energy may damage the device and should not be used. Additionally, the
device must not be exposed to flux or solvents that are Chlorine- or Fluorine-based.
R02
www.ixysic.com
5
INTEGRATED CIRCUITS DIVISION
CPC1964BX6
MECHANICAL DIMENSIONS
CPC1964BX6
21.082 ± 0.381
(0.830 ± 0.015)
Pin 8
16.764 ± 0.381
(0.660 ± 0.015)
0.127 ± 0.076
(0.005 ± 0.003)
15.90
(0.626)
10.160 ± 0.254
(0.400 ± 0.010)
2.00
(0.079)
0.889 ± 0.127
(0.035 ± 0.005)
Pin 1
0.762 ± 0.102
(0.030 ± 0.004)
5.080 ± 0.127
(0.200 ± 0.005)
7.622 ± 0.127
(0.300 ± 0.005)
Recommended PCB Pattern
3.302 ± 0.051
(0.130 ± 0.002)
1.524 typ
(0.060)
1.016 ± 0.127
(0.040 ± 0.005)
1.651 ± 0.102
(0.065 ± 0.004)
5.080 ± 0.127
(0.200 ± 0.005)
0.381 ± 0.025
(0.015 ± 0.001)
Dimensions
Unless Otherwise Noted
mm
Note: Pin-to-pin tolerances are non-cumulative.
(inches)
5.080
(0.200)
7.622
(0.300)
5.080
(0.200)
0.95
(0.037)
For additional information please visit our website at: www.ixysic.com
IXYS Integrated Circuits makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes
to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated Circuits'
Standard Terms and Conditions of Sale, IXYS Integrated Circuits assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but
not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits' product may result in direct physical harm, injury, or death to a person or severe property
or environmental damage. IXYS Integrated Circuits reserves the right to discontinue or make changes to its products at any time without notice.
6
Specification: DS-CPC1964BX6-R02
©Copyright 2018, IXYS Integrated Circuits
All rights reserved. Printed in USA.
6/29/2018