LCA125L
300V, 170mA Single-Pole
Normally Open Relay
INTEGRATED CIRCUITS DIVISION
Parameter
Blocking Voltage
Load Current
On-Resistance (max)
Ratings
300
170
20
Units
VP
mArms / mADC
Features
•
•
•
•
•
•
•
•
•
•
Current Limiting
3750Vrms Input/Output Isolation
Low Drive Power Requirements
Greater Reliability than Electromechanical Relays
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Small 6-Pin Package
Flammability Rating UL 94 V-0
Surface Mount Tape & Reel Version Available
Description
LCA125L is a current-limiting, 300V, 170mA, 20,
normally open (1-Form-A) solid state relay that uses
optically coupled MOSFET technology to provide
3750Vrms of input to output isolation.
Its optically coupled outputs, which use the patented
OptoMOS architecture, are controlled by a highly
efficient infrared LED.
The LCA125L can be used to replace mechanical
relays and offers the superior reliability associated with
semiconductor devices. Because it has no moving
parts, it offers faster, bounce-free switching in a
compact surface mount or thru-hole package.
Approvals
• UL Recognized Component: File # E76270
• CSA Certified Component: Certificate # 1175739
• TUV EN 62368-1: Certificate # B 082667 0008
Applications
• Telecommunications
• Telecom Switching
• Tip/Ring Circuits
• Modem Switching (Laptop, Notebook, Pocket Size)
• Hook Switch
• Dial Pulsing
• Ground Start
• Ringing Injection
• Instrumentation
• Multiplexers
• Data Acquisition
• Electronic Switching
• I/O Subsystems
• Meters (Watt-Hour, Water, Gas)
• Medical Equipment—Patient/Equipment Isolation
• Security
• Industrial Controls
Ordering Information
Part #
LCA125L
LCA125LS
LCA125LSTR
Description
6-Pin DIP (50/Tube)
6-Pin Surface Mount (50/Tube)
6-Pin Surface Mount (1,000/Reel)
Pin Configuration
AC/DC Configuration
+ Control
– Control
Do Not Use
1
6
2
5
3
4
Load
Do Not Use
Load
DC Only Configuration
+ Control
– Control
Do Not Use
1
6
2
5
3
4
+ Load
– Load
Switching Characteristics of
Normally Open Devices
Form-A
IF
90%
10%
ILOAD
ton
DS-LCA125L-R08
www.ixysic.com
toff
1
INTEGRATED CIRCUITS DIVISION
LCA125L
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature, Ambient
Storage Temperature
1
Derate linearly 1.33 mW / ºC
2
Derate output power linearly 6.67 mW / ºC
Ratings
300
5
50
1
150
800
3750
-40 to +85
-40 to +125
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
Typical values are characteristic of the device at +25°C,
and are the result of engineering evaluations. They are
provided for information purposes only, and are not part of
the manufacturing testing requirements.
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
Blocking Voltage
Load Current, Continuous
AC/DC Configuration
DC Configuration
Load Current Limiting
On-Resistance 1
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current to Activate
Input Control Current to Deactivate
Input Voltage Drop
Reverse Input Current
Common Characteristics
Capacitance, Input to Output
1
Conditions
Symbol
Min
Typ
Max
Units
IL=1A
VDRM
300
-
-
VP
190
235
170
300
280
mArms / mADC
mADC
mA
12
4
-
20
6
1
ILEAK
-
µA
IF=0mA, VL=50V, f=1MHz
ton
toff
COUT
-
50
5
5
-
ms
ms
pF
IL = 170mA
IF = 5mA
VR = 5V
IF
IF
VF
IR
0.4
0.9
-
0.7
1.36
-
5
1.5
10
mA
mA
V
µA
VIO=0V, f=1MHz
CIO
-
3
-
pF
-
IL
ICL
IL=170mA
IL=300mA
VL=300VP
RON
IF = 5mA, VL = 10V
Measurement taken within 1 second of on-time.
2
www.ixysic.com
R08
INTEGRATED CIRCUITS DIVISION
LCA125L
PERFORMANCE DATA*
Typical LED Forward Voltage Drop
(N=50, IF=5mA)
30
30
25
30
15
10
5
Device Count (N)
20
20
15
10
5
0
40
0.23
0.32
0.41 0.50 0.59 0.68
Turn-On Time (ms)
15
10
15
10
5
0.88
1.03 1.18 1.33
LED Current (mA)
1.48
0.30
25
20
15
10
5
0
0.73
0.14 0.18 0.22 0.26
Turn-Off Time (ms)
30
20
5
0
0.10
Typical On-Resistance Distribution
(N=50, IF=5mA, IL=170mADC)
35
Device Count (N)
Device Count (N)
Device Count (N)
20
10
0.06
Typical IF for Switch Dropout
(N=50, IL=170mADC)
25
25
15
0.77
35
30
20
0
1.366
1.368
1.370
1.372
LED Forward Voltage Drop (V)
Typical IF for Switch Operation
(N=50, IL=170mADC)
25
5
0
1.364
Typical Turn-Off Time
(N=50, IF=5mA, IL=170mADC)
35
25
Device Count (N)
Device Count (N)
Typical Turn-On Time
(N=50, IF=5mA, IL=170mADC)
0
1.63
0.3
0.5
0.7
0.9
1.1
LED Current (mA)
1.3
1.5
14.0
14.4
14.8
15.2
On-Resistance (:)
15.6
Typical Blocking Voltage Distribution
(N=50)
35
Device Count (N)
30
25
20
15
10
5
0
380
1.6
IF=10mA
IF=5mA
IF=2mA
1.5
1.4
1.3
1.2
0.35
0.30
0.25
0.20
0.15
1.1
-50
-25
0
25
50
Temperature (ºC)
75
100
0.15
0.14
0.13
0.12
0.11
0.10
1.0
Typical Turn-Off Time
vs. LED Forward Current
(IL=170mADC)
0.16
Turn-Off Time (ms)
Turn-On Time (ms)
LED Forward Voltage Drop (V)
0.40
1.7
400
Typical Turn-On Time
vs. LED Forward Current
(IL=170mADC)
Typical LED Forward Voltage Drop
vs. Temperature
1.8
384
388
392
396
Blocking Voltage (VP)
0.10
0
2
4
6
8 10 12 14 16
LED Forward Current (mA)
18
20
0
2
4
6
8 10 12 14 16
LED Forward Current (mA)
18
20
*Unless otherwise noted, data presented in these graphs is typical of device operation at 25ºC.
R08
www.ixysic.com
3
INTEGRATED CIRCUITS DIVISION
LCA125L
PERFORMANCE DATA*
Typical Turn-On Time
vs. Temperature
(IL=170mADC)
0.30
0.5
0.4
0.3
0.2
0.1
0.25
0.20
0.15
0.10
-40
-20
0
20
40
60
Temperature (ºC)
80
Typical IF for Switch Operation
vs. Temperature
(IL=170mADC)
3.0
0
20
40
60
Temperature (ºC)
80
1.5
1.0
Typical IF for Switch Dropout
vs. Temperature
(IL=170mADC)
1.0
0
0
-40
-20
0
20
40
60
Temperature (ºC)
80
-20
200
0
20
40
60
Temperature (ºC)
80
150
100
50
-40
-20
0
20
40
60
80
Temperature (ºC)
100
50
0
-50
-100
0.18
395
0.16
390
385
380
0.14
0.12
0.10
0.08
0.06
-40
-20
0
20
40
60
Temperature (ºC)
80
100
-40
-20
0
20
40
60
Temperature (ºC)
80
100
Typical Current Limiting
vs. Temperature
(IF=5mA)
Energy Rating Curve
1.2
400
350
1.0
300
Current (mA)
Load Current (A)
100
400
120
100
Typical Leakage vs. Temperature
Measured across Pins 4&6
375
0
80
-200
-2.5 -2.0 -1.5 -1.0 -0.5 0 0.5 1.0 1.5 2.0 2.5
Load Voltage (V)
100
Leakage (PA)
250
Blocking Voltage (VP)
IF=20mA
IF=10mA
IF=5mA
20
40
60
Temperature (ºC)
Typical Load Current vs. Load Voltage
(IF=5mA)
Typical Blocking Voltage
vs. Temperature
Maximum Load Current
vs. Temperature
300
0
-150
-40
100
-20
150
1.5
0.5
20
200
2.0
0.5
30
-40
Load Current (mA)
2.0
40
100
2.5
LED Current (mA)
LED Current (mA)
-20
3.0
2.5
50
0
0
-40
100
Typical On-Resistance vs. Temperature
(IF=5mA, IL=170mADC)
10
0.05
0
Load Current (mA)
60
On-Resistance (:)
IF=5mA
IF=10mA
IF=20mA
Turn-Off Time (ms)
Turn-On Time (ms)
0.6
Typical Turn-Off Time
vs. Temperature
(IF=5mA, IL=170mADC)
0.8
0.6
0.4
250
200
150
100
0.2
50
0
10Ps 100Ps 1ms 10ms 100ms
0
1s
10s
100s
-40
Time
-20
0
20
40
60
Temperature (ºC)
80
100
*Unless otherwise noted, data presented in these graphs is typical of device operation at 25ºC.
4
www.ixysic.com
R08
INTEGRATED CIRCUITS DIVISION
LCA125L
Manufacturing Information
Moisture Sensitivity
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated
Circuits classifies its plastic encapsulated devices for moisture sensitivity according to the latest version of
the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of
our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices
when handled according to the limitations and information in that standard as well as to any limitations set forth in the
information or standards referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced product
performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) classification as shown below, and should be handled
according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
Device
Moisture Sensitivity Level (MSL) Classification
LCA125LS
MSL 1
ESD Sensitivity
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Soldering Profile
Provided in the table below is the IPC/JEDEC J-STD-020 Classification Temperature (TC) and the maximum total dwell
time (tP) in all reflow processes that the body temperature of these surface mount devices may be (TC - 5)°C or greater.
The device’s body temperature must not exceed the Classification Temperature at any time during reflow soldering
processes.
Device
Classification Temperature (Tc)
Dwell Time (tP)
Max Reflow Cycles
LCA125LS
250ºC
30 seconds
3
For through-hole devices, the maximum pin temperature and maximum dwell time through all solder waves is
provided in the table below. Dwell time is the interval beginning when the pins are initially immersed into the solder
wave until they exit the solder wave. For multiple waves, the dwell time is from entering the first wave until exiting the
last wave. During this time, pin temperatures must not exceed the maximum temperature given in the table below.
Body temperature of the device must not exceed the limit shown in the table below at any time during the soldering
process.
Device
LCA125L
Maximum Pin Temperature
260ºC
Maximum Body Temperature
250ºC
Maximum Dwell Time
10 seconds*
Wave Cycles
1
*Total cumulative duration of all waves.
Board Wash
IXYS Integrated Circuits recommends the use of no-clean flux formulations. Board washing to reduce or remove flux
residue following the solder reflow process is acceptable provided proper precautions are taken to prevent damage to
the device. These precautions include but are not limited to: using a low pressure wash and providing a follow up bake
cycle sufficient to remove any moisture trapped within the device due to the washing process. Due to the variability
of the wash parameters used to clean the board, determination of the bake temperature and duration necessary
to remove the moisture trapped within the package is the responsibility of the user (assembler). Cleaning or drying
methods that employ ultrasonic energy may damage the device and should not be used. Additionally, the device must
not be exposed to halide flux or solvents.
R08
www.ixysic.com
5
INTEGRATED CIRCUITS DIVISION
LCA125L
MECHANICAL DIMENSIONS
LCA125L
8.382±0.381
(0.330±0.015)
7.239 TYP
(0.285 TYP)
2.54±0.127
(0.100±0.005)
PCB Hole Pattern
6 - 0.800 DIA.
(6 - 0.031 DIA.)
9.144±0.508
(0.360±0.020)
6.350±0.127
(0.250±0.005)
Pin 1
1.524 TYP
(0.060 TYP)
1.651±0.254
(0.065±0.010)
2.540±0.127
(0.100±0.005)
7.620±0.127
(0.300±0.005)
7.620±0.254
(0.300±0.010)
0.254±0.0127
(0.010±0.0005)
5.080±0.127
(0.200±0.005)
Controlling dimension: inches
3.302±0.051
(0.130±0.002)
4.064 TYP
(0.160 TYP)
Dimensions
mm
(inches)
0.457±0.076
(0.018±0.003)
LCA125LS
8.382±0.381
(0.330±0.015)
9.524±0.508
(0.375±0.020)
Pin 1
0.635±0.127
(0.025±0.005)
2.54
(0.10)
6.350±0.127
(0.250±0.005)
0.457±0.076
(0.018±0.003)
1.651±0.254
(0.065±0.010)
7.620±0.254
(0.300±0.010)
0.254±0.0127
(0.010±0.0005)
8.90
(0.3503)
1.65
(0.0649)
0.65
(0.0255)
3.302±0.051
(0.130±0.002)
4.445±0.254
(0.175±0.010)
Controlling dimension: inches
1.524 TYP
(0.060 TYP)
1.651±0.254
(0.065±0.010)
6
PCB Land Pattern
2.54±0.127
(0.100±0.005)
Dimensions
mm
(inches)
www.ixysic.com
R08
INTEGRATED CIRCUITS DIVISION
LCA125L
LCA125LSTR Tape & Reel
P1 = 12.00
(0.472)
330.2 Dia
(13.00 Dia)
Top Cover
Tape Thickness
0.102 Max
(0.004 Max)
W=16.00
(0.63)
B0 = 10.10
(0.398)
K0 = 4.90
(0.19)
K1 = 3.80
(0.15)
A0 = 10.10
(0.398)
User Direction of Feed
Embossed
Carrier
Embossment
Dimensions
mm
(inches)
NOTES:
1. All dimensions carry tolerances of EIA Standard 481-2
2. The tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2
For additional information please visit our website at: https://www.ixysic.com
Disclaimer Notice - Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and
test each product selected for their own applications. Littelfuse products are not designed for, and may not be used in, all applications.
Read complete Disclaimer Notice at https://www.littelfuse.com/disclaimer-electronics.
7
Specification: DS-LCA125L-R08
©Copyright 2021, Littelfuse, Inc.
OptoMOS® is a registered trademark of IXYS Integrated Circuits
All rights reserved. Printed in USA.
11/2/2021