LCA182

LCA182

  • 厂商:

    IXYS(艾赛斯)

  • 封装:

    DIP6

  • 描述:

    1 FORM A(SPSTNO) 负载AC,DC 负载电压350V

  • 数据手册
  • 价格&库存
LCA182 数据手册
LCA182 350V, 120mA Single-Pole Normally Open Relay INTEGRATED CIRCUITS DIVISION Parameter Blocking Voltage Load Current On-Resistance (max) Input Control Current Rating 350 120 35 0.25 Units VP mArms / mADC  mA Features • Very Low Input Control Current (0.25mA) • 3750Vrms Input/Output Isolation • Low Drive Power Requirements • Greater Reliability than Electromechanical Relays • No EMI/RFI Generation • Small 6-Pin Package • Surface Mount, Tape & Reel Version Available • Flammability Rating UL 94 V-0 Applications • Telecommunications • Telecom Switching • Tip/Ring Circuits • Modem Switching (Laptop, Notebook, PocketSize) • Hook Switch • Dial Pulsing • Ground Start • Ringing Injection • Instrumentation • Multiplexers • Data Acquisition • Electronic Switching • I/O Subsystems • Meters (Watt-Hour, Water, Gas) • Medical Equipment Patient/Equipment Isolation • Industrial Controls Description LCA182 is a normally open (1-Form-A) solid state relay that uses optically coupled MOSFET technology to provide 3750Vrms of input to output isolation. It features an extremely low input control current of only 0.25mA, which is the lowest available in IXYS Integrated Circuits Division’s Solid State Relay family. Its optically coupled outputs, which use the patented OptoMOS architecture, are controlled by a highly efficient infrared LED. The LCA182 can be used to replace mechanical relays, and offers the superior reliability associated with semiconductor devices. Because it has no moving parts, it offers faster, bounce-free switching in a more compact surface mount or through-hole package. Approvals • UL Recognized Component: File # E76270 • CSA Certified Component: Certificate # 1175739 • TUV EN 62368-1: Certificate # B 082667 0008 Ordering Information Part # LCA182 LCA182S LCA182STR Description 6 Pin DIP (50/Tube) 6 Pin Surface Mount (50/Tube) 6 Pin Surface Mount (1000/Reel) Pin Configuration AC/DC Configuration + Control – Control Do Not Use 1 6 2 5 3 4 Load Do Not Use Load DC Only Configuration + Control – Control Do Not Use 1 6 2 5 3 4 + Load – Load Switching Characteristics of Normally Open (Form A) Devices Form-A IF 90% 10% ILOAD ton DS-LCA182-R05 www.ixysic.com toff 1 INTEGRATED CIRCUITS DIVISION LCA182 Absolute Maximum Ratings @ 25°C Parameter Blocking Voltage Reverse Input Voltage Input Control Current Peak (10ms) Input Power Dissipation 1 Total Power Dissipation 2 Isolation Voltage, Input to Output Operational Temperature, Ambient Storage Temperature 1 Derate linearly 1.33 mW / °C 2 Derate output power linearly 6.67 mW / °C Ratings 350 5 50 1 150 800 3750 -40 to +85 -40 to +125 Units VP V mA A mW mW Vrms °C °C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Typical values are characteristic of the device at the specified temperatures and are the result of engineering evaluations. They are provided for information purposes only and are not part of the manufacturing testing requirements. Electrical Characteristics @ 25°C Parameter Output Characteristics Blocking Voltage Load Current Continuous, AC/DC Configuration Continuous, DC Configuration Peak On-Resistance 1 AC/DC Configuration DC Configuration Off-State Leakage Current Switching Speeds Turn-On Turn-Off Output Capacitance Input Characteristics Input Control Current to Activate 2 Input Control Current to Deactivate Input Voltage Drop Reverse Input Current Common Characteristics Input to Output Capacitance Conditions Symbol Min Typ Max Units IL=1A VDRM 350 - - VP - IL - - t=10ms ILPK - - 120 200 350 mArms / mADC mADC mA RON - 35 10 1  ILEAK 23 7 - - 25 3 3 - IL=120mA IL=200mA VL=350VP µA IF=0mA, VL=50V, f=1MHz ton toff COUT IL=120mA IF=1mA VR=5V IF IF VF IR 0.05 0.9 - 1.2 - 0.25 1.4 10 mA mA V µA VIO=0V, f=1MHz CIO - 3 - pF IF=1mA, VL=10V - ms pF 1 Measurement taken within one second of on-time. 2 It is recommended that the input control current be increased to 1mA in high temperature (>55ºC) operation. 2 www.ixysic.com R05 INTEGRATED CIRCUITS DIVISION LCA182 PERFORMANCE DATA* 25 20 15 10 5 1.17 35 15 10 5 Typical IF for Switch Operation (N=50, IL=120mADC) 0.456 0.476 0.496 0.516 Turn-On Time (ms) Device Count (N) 15 10 15 10 0 0 0.10 0.15 0.20 LED Current (mA) 0.193 0.203 0.213 0.223 Turn-Off Time (ms) 0.233 Typical On-Resistance Distribution (N=50, IL=120mADC) 30 20 5 5 35 25 5 10 0.183 30 20 15 0.536 Typical IF for Switch Dropout (N=50, IL=120mADC) 35 25 20 0 0.436 1.19 1.21 1.23 1.25 LED Forward Voltage Drop (V) 30 Device Count (N) 20 0 0 Typical Turn-Off Time (N=50, IF=2mA, IL=120mADC) 25 Device Count (N) Device Count (N) Device Count (N) 30 25 Typical Turn-On Time (N=50, IF=2mA, IL=120mADC) Device Count (N) 35 Typical LED Forward Voltage Drop (N=50, IF=5mA) 25 20 15 10 5 0 0.25 0.10 0.15 0.20 LED Current (mA) 0.25 21.5 21.7 21.9 22.1 22.3 22.5 On-Resistance (:) 22.7 Typical Blocking Voltage Distribution (N=50) 35 Device Count (N) 30 25 20 15 10 5 0 390 IF=50mA 1.2 IF=10mA IF=5mA IF=0.25mA 1.0 0.8 -40 -20 0 20 40 60 Temperature (ºC) 80 100 120 450 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 Typical Turn-Off Time vs. LED Forward Current (IL=120mADC) 0.7 0.6 Turn-Off Time (ms) 1.4 Turn-On Time (ms) LED Forward Voltage Drop (V) 1.6 410 420 430 440 Blocking Voltage (VP) Typical Turn-On Time vs. LED Forward Current (IL=120mADC) Typical LED Forward Voltage Drop vs. Temperature 1.8 400 0.5 0.4 0.3 0.2 0.1 0 0 2 4 6 8 10 12 14 16 LED Forward Current (mA) 18 20 0 2 4 6 8 10 12 14 16 LED Forward Current (mA) 18 20 *Unless otherwise noted, data presented in these graphs is typical of device operation at 25ºC. R05 www.ixysic.com 3 INTEGRATED CIRCUITS DIVISION LCA182 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 IF=0.25mA IF=0.5mA IF=5mA -40 -20 0 20 40 60 Temperature (ºC) 80 0 20 40 60 Temperature (ºC) 80 0.00 -20 0 20 40 60 Temperature (ºC) 80 Typical Load Current vs. Load Voltage (IF=2mA) 50 0 -50 -100 -3 -2 -1 0 1 Load Voltage (V) 2 80 100 180 160 IF=2mA 140 AC/DC Configuration 120 100 IF=1mA IF=2mA 80 IF=1mA -20 0 20 40 60 Temperature (ºC) 80 -40 100 -20 0 20 40 60 80 Temperature (ºC) 100 120 Typical Leakage vs. Temperature (Measured across Pins 4 & 6) 430 0.016 425 0.014 420 415 410 405 0.012 0.010 0.008 0.006 0.004 400 0.002 -40 3 20 40 60 Temperature (ºC) 0 395 -150 0 DC Configuration Typical Blocking Voltage vs. Temperature Blocking Voltage (VP) 100 -20 60 -40 100 10 200 0.10 0.00 -40 20 210 0.15 0.05 30 Maximum Load Current vs. Temperature 0.20 0.05 40 -40 Leakage (PA) 0.10 IF=1mA IF=2mA IF=5mA 50 100 Load Current (mA) LED Current (mA) LED Current (mA) -20 0.25 0.15 150 60 Typical IF for Switch Dropout vs. Temperature (IL=70mADC) 0.30 0.20 Typical On-Resistance vs. Temperature (IL=70mADC) 0 -40 0.25 Load Current (mA) 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 100 Typical IF for Switch Operation vs. Temperature (IL=70mADC) 0.30 Typical Turn-Off Time vs. Temperature (IF=0.25mA, IL=70mADC) On-Resistance (:) Typical Turn-On time vs. Temperature (IL=70mADC) Turn-Off Time (ms) Turn-On Time (ms) PERFORMANCE DATA* -20 0 20 40 60 Temperature (ºC) 80 100 10s 100s 0 -40 -20 0 20 40 60 Temperature (ºC) 80 100 Load Current (A) Energy Rating Curve 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 10Ps 100Ps 1ms 10ms 100ms Time 1s *Unless otherwise noted, data presented in these graphs is typical of device operation at 25ºC. 4 www.ixysic.com R05 INTEGRATED CIRCUITS DIVISION LCA182 Manufacturing Information Moisture Sensitivity All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated Circuits classifies its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according to the limitations and information in that standard as well as to any limitations set forth in the information or standards referenced below. Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced product performance, reduction of operable life, and/or reduction of overall reliability. This product carries a Moisture Sensitivity Level (MSL) classification as shown below, and should be handled according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033. Device Moisture Sensitivity Level (MSL) Classification LCA182S MSL 1 ESD Sensitivity This product is ESD Sensitive, and should be handled according to the industry standard JESD-625. Soldering Profile Provided in the table below is the IPC/JEDEC J-STD-020 Classification Temperature (TC) and the maximum total dwell time (tP) in all reflow processes that the body temperature of these surface mount devices may be (TC - 5)°C or greater. The device’s body temperature must not exceed the Classification Temperature at any time during reflow soldering processes. Device Classification Temperature (Tc) Dwell Time (tP) Max Reflow Cycles LCA182S 250ºC 30 seconds 3 For through-hole devices, the maximum pin temperature and maximum dwell time through all solder waves is provided in the table below. Dwell time is the interval beginning when the pins are initially immersed into the solder wave until they exit the solder wave. For multiple waves, the dwell time is from entering the first wave until exiting the last wave. During this time, pin temperatures must not exceed the maximum temperature given in the table below. Body temperature of the device must not exceed the limit shown in the table below at any time during the soldering process. Device LCA182 Maximum Pin Temperature 260ºC Maximum Body Temperature 250ºC Maximum Dwell Time 10 seconds* Wave Cycles 1 *Total cumulative duration of all waves. Board Wash IXYS Integrated Circuits recommends the use of no-clean flux formulations. Board washing to reduce or remove flux residue following the solder reflow process is acceptable provided proper precautions are taken to prevent damage to the device. These precautions include but are not limited to: using a low pressure wash and providing a follow up bake cycle sufficient to remove any moisture trapped within the device due to the washing process. Due to the variability of the wash parameters used to clean the board, determination of the bake temperature and duration necessary to remove the moisture trapped within the package is the responsibility of the user (assembler). Cleaning or drying methods that employ ultrasonic energy may damage the device and should not be used. Additionally, the device must not be exposed to halide flux or solvents. R05 www.ixysic.com 5 INTEGRATED CIRCUITS DIVISION LCA182 MECHANICAL DIMENSIONS LCA182 8.382±0.381 (0.330±0.015) PCB Hole Pattern 7.239 TYP (0.285 TYP) 2.54±0.127 (0.100±0.005) 6 - 0.800 DIA. (6 - 0.031 DIA.) 9.144±0.508 (0.360±0.020) 6.350±0.127 (0.250±0.005) 1.524 TYP (0.060 TYP) Pin 1 1.651±0.254 (0.065±0.010) 2.540±0.127 (0.100±0.005) 7.620±0.127 (0.300±0.005) 7.620±0.254 (0.300±0.010) 0.254±0.0127 (0.010±0.0005) 5.080±0.127 (0.200±0.005) Controlling dimension: inches 3.302±0.051 (0.130±0.002) 4.064 TYP (0.160 TYP) Dimensions mm (inches) 0.457±0.076 (0.018±0.003) LCA182S 8.382±0.381 (0.330±0.015) 9.524±0.508 (0.375±0.020) Pin 1 0.635±0.127 (0.025±0.005) 2.54 (0.10) 6.350±0.127 (0.250±0.005) 0.457±0.076 (0.018±0.003) 1.651±0.254 (0.065±0.010) 7.620±0.254 (0.300±0.010) 0.254±0.0127 (0.010±0.0005) 8.90 (0.3503) 1.65 (0.0649) 0.65 (0.0255) 3.302±0.051 (0.130±0.002) 4.445±0.254 (0.175±0.010) Controlling dimension: inches 1.524 TYP (0.060 TYP) 1.651±0.254 (0.065±0.010) 6 PCB Land Pattern 2.54±0.127 (0.100±0.005) Dimensions mm (inches) www.ixysic.com R05 INTEGRATED CIRCUITS DIVISION LCA182 LCA182STR Tape & Reel 330.2 Dia (13.00 Dia) P1 = 12.00 (0.472) Top Cover Tape Thickness 0.102 Max (0.004 Max) W=16.00 (0.63) B0 = 10.10 (0.398) K0 = 4.90 (0.19) K1 = 3.80 (0.15) A0 = 10.10 (0.398) User Direction of Feed Embossed Carrier Embossment Dimensions mm (inches) NOTES: 1. All dimensions carry tolerances of EIA Standard 481-2 2. The tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2 For additional information please visit our website at: https://www.ixysic.com Disclaimer Notice - Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are not designed for, and may not be used in, all applications. Read complete Disclaimer Notice at https://www.littelfuse.com/disclaimer-electronics. 7 Specification: DS-LCA182-R05 ©Copyright 2021, Littelfuse, Inc. OptoMOS® is a registered trademark of IXYS Integrated Circuits All rights reserved. Printed in USA. 11/3/2021
LCA182 价格&库存

很抱歉,暂时无法提供与“LCA182”相匹配的价格&库存,您可以联系我们找货

免费人工找货
LCA182
  •  国内价格 香港价格
  • 1+48.760941+6.29954
  • 10+43.4583710+5.61449
  • 25+41.5021625+5.36176
  • 50+40.0812350+5.17819
  • 100+38.70616100+5.00054
  • 250+36.95981250+4.77492
  • 500+35.69018500+4.61090
  • 1000+34.463691000+4.45244

库存:0