PM1206
AC Power Switch
INTEGRATED CIRCUITS DIVISION
Parameter
AC Operating Voltage
Load Current
On-State Voltage Drop
(IL=500mArms)
Rating
260
500
1.4
Features
• Load Current up to 0.5Arms
• Blocking Voltages up to 600VP
• 5mA Sensitivity
• Zero-Crossing Detection
• DC Control, AC Output
• Optically Isolated
• Low EMI and RFI Generation
• High Noise Immunity
• VDE compatible
• Flammability Rating UL 94 V-0
Applications
• Programmable Control
• Process Control
• Power Control Panels
• Remote Switching
• Gas Pump Electronics
• Contactors
• Large Relays
• Solenoids
• Motors
• Heaters
Units
Vrms
mArms
Vrms
Description
The PM1206 is an AC Solid State Switch using optical
coupling with dual power SCR outputs to produce
an alternative to optocoupler and Triac circuits. The
PM1206 switches are robust enough to provide a
blocking voltage of up to 600VP. In addition, tightly
controlled zero-cross circuitry ensures switching of
AC loads without the generation of transients. The
input and output circuits are optically coupled to
provide 3750Vrms of isolation and noise immunity
between control and load circuits. As a result, the
PM1206 is well suited for industrial environments
where electromagnetic interference could disrupt the
operation of electromechanical relays.
Approvals
• UL Recognized Component: UL 508 File E69938
• CSA Certified Component: File 043639
Ordering Information
Part #
PM1206
PM1206S
PM1206STR
Description
6-Lead DIP (50/Tube)
6-Lead Surface Mount (50/Tube)
6-Lead Surface Mount (1000/Reel)
Pin Configuration
1
6
+ LED
– LED
2
3
DS-PM1206-R11
www.ixysic.com
ZC
5
AC Load
AC Load
4
1
INTEGRATED CIRCUITS DIVISION
PM1206
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Package Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1
Derate linearly 1.33 mW / ºC
2
Derate linearly 6.67 mW / ºC
Min
3750
-40
-40
Max
600
5
100
1
150
800
+85
+125
Units
VP
V
mA
A
mW
mW
Vrms
ºC
ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Typical values are characteristic of the device at +25°C,
and are the result of engineering evaluations. They are
provided for information purposes only, and are not part of
the manufacturing testing requirements.
Electrical Characteristics @ 25ºC
Parameter
Output Characteristics
AC Operating Voltage
Load Current (Continuous)
Maximum Surge Current
Off-State Leakage Current
On-State Voltage Drop
Critical Rate of Rise
Switching Speeds
Turn-On
Turn-Off
Zero-Cross Turn-On Voltage 1
Operating Frequency
Load Power Factor for Guaranteed Turn-On 2
Capacitance Input-To-Output
Input Characteristics
Input Control Current
For Normal Environment
For High Noise Environment
Input Voltage Drop
Input Dropout Voltage
Reverse Input Current
1
2
2
Conditions
Symbol
Min
Typ
Max
Units
IF=5mA
VL=120-240VAC
t
很抱歉,暂时无法提供与“PM1206”相匹配的价格&库存,您可以联系我们找货