EMI-RFI Filters
GF Metal Box Single-Phase Filters
Overview
Applications
The KEMET GF compact metal box filters cover singlephase requirements with a wide variety of characteristics.
These filters are optimized for conduction noise. Their
input/output terminals are screw type or Faston® type.
• Industrial equipment
• Electronic equipment
Benefits
• Single-phase 250 VAC
• Current range from 5 to 20 A
• Operating temperature range from -20°C to +60°C
(except GF-205E at -20°C to +55°C)
• UL or CSA approved versions available
• RoHS compliant
Part Number System
GF-
2
20
U
Series
Phase
Rated Current (A)
Specification
GF
2 = Single-phase
0x = 0x A
xx = xx A
E = Faston® terminal, CSA approved
U = Screw terminal, UL approved
Note: Faston® is a registered trademark of
Tyco Electronics AMP
Built Into Tomorrow
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0003_GF • 12/2/2020
1
EMI-RFI Filters – GF Metal Box Single-Phase Filters
Dimensions – Millimeters
GF-2**U
Recommended torque (N-m) maximum
• Line terminal (M4: 0.78)
• Earth terminal (M4: 1.18)
GF-2**E
Recommended torque (N-m) maximum
• Line terminal (M4: 0.78)
• Earth terminal (M4: 1.18)
Faston® is a registered trademark of Tyco Electronics AMP.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0003_GF • 12/2/2020
2
EMI-RFI Filters – GF Metal Box Single-Phase Filters
Environmental Compliance
KEMET GF EMI-RFI Filters comply with EU RoHS Directive 2011/65/EU and (EU) 2015/863.
Products that fall under the exemptions listed in below table are also included.
Part Number
RoHS Compliant
RoHS Exemption Code
GF-205U
Yes
6(c) and 7(c)-I
GF-210U
Yes
6(c) and 7(c)-I
GF-220U
Yes
6(c) and 7(c)-I
GF-205E
Yes
7(c)-I
Code
Exemption
6(c)
Copper alloy containing up to 4% lead by weight
7(c)-I
Electrical and electronic components containing lead in a glass
or ceramic other than dielectric ceramic in capacitors, e.g.
piezoelectronic devices, or in a glass or ceramic matrix compound
Approvals
Certification Body
File Number
Part Number
UL
E59551
GF-205U, GF-210U and GF-220U
CSA
LR50413
GF-205E
Performance Characteristics
Item
Rated Voltage
Rated Current Range
Withstanding Voltage
Insulation Resistance
Leakage Current
Input/Output Terminal Type
Operating Temperature Range
Performance Characteristics
250 V
5 – 20 A
1,500 VAC (1 minute, line to ground)
300 MΩ minimum at 500 VDC (1 minute, line to ground)
1 mA maximum at 250 V/60 Hz
Screw and Faston®
−20°C to +60°C, except GF-205E at −20°C to +55°C
(not including self temperature rise)
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0003_GF • 12/2/2020
3
EMI-RFI Filters – GF Metal Box Single-Phase Filters
Table 1 – Ratings & Part Number Reference
Rated
Current
AC/DC (A)
Leakage
Operating
Current at 250 Temperature
Rise (K)
Temperature
V/60 Hz (mA) Maximum
Range
Maximum
Part Number
Phase
Rated
Voltage
AC/DC (V)
GF-205U
Single-phase
250
5
1
30
-20°C to +60°C
Screw
UL
130
GF-210U
Single-phase
250
10
1
30
-20°C to +60°C
Screw
UL
140
GF-220U
Single-phase
250
20
1
30
-20°C to +60°C
Screw
UL
150
GF-205E
Single-phase
250
5
1
30
-20°C to +55°C
Faston®
CSA
130
Terminal
Type
Approval
Weight (g)
Circuit Diagram
Measuring Circuit - Common Mode
Measuring Circuit - Normal Mode
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0003_GF • 12/2/2020
4
EMI-RFI Filters – GF Metal Box Single-Phase Filters
Attenuation (Static Characteristics)
GF-205U
GF-210U
GF-220U
GF-205E
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0003_GF • 12/2/2020
5
EMI-RFI Filters – GF Metal Box Single-Phase Filters
Packaging
Part Type
Packaging Type
Pieces per Box
GF-2**U
GF-2**E
Tray
10
50
Handling Precautions
Precautions for product storage
EMI-RFI Filters should be stored in normal working environments. While the filters themselves are quite robust in other
environments, solderability will be degraded by exposure to high temperatures, high humidity, corrosive atmospheres, and
long term storage.
KEMET recommends that maximum storage temperature not exceed 40°C, maximum storage humidity not exceed 70%
relative humidity, and atmospheres should be free of chlorine and sulfur bearing compounds. Temperature fluctuations
should be minimized to avoid condensation on the parts. Also, avoid storage near strong magnetic fields as this might
magnetize the product.
EMI-RFI Filters’ stock should be used promptly, preferably within 12 months of receipt.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0003_GF • 12/2/2020
6
EMI-RFI Filters – GF Metal Box Single-Phase Filters
KEMET Electronics Corporation Sales Offices
For a complete list of our global sales offices, please visit www.kemet.com/sales.
Disclaimer
All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such
applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no
obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or
property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
When providing KEMET products and technologies contained herein to other countries, the customer must abide by the procedures and provisions stipulated in all
applicable export laws and regulations, including without limitation the International Traffic in Arms Regulations (ITAR), the US Export Administration Regulations
(EAR) and the Japan Foreign Exchange and Foreign Trade Act.
KEMET is a registered trademark of KEMET Electronics Corporation.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0003_GF • 12/2/2020
7
很抱歉,暂时无法提供与“GF-220U”相匹配的价格&库存,您可以联系我们找货
免费人工找货