EMI-RFI Filters
GTX Metal Box Three-Phase Filters
Overview
Applications
The KEMET GTX metal case filters cover three-phase EMC
requirements with a wide variety of characteristics. By
using nanocrystalline core material, these filters achieve
excellent attenuation characteristics in a compact size.
In addition, 6 different combinations of Y capacitors can
be selected to support various equipment topologies.
These filters are compact and lightweight due to its high
mechanical density.
• Industrial equipment
• General purpose inverter
• Process automation
• Machine tools
Benefits
• Three-phase 500 VAC
• Current range from 30 to 60 A
• Nanocrystalline core material
• Selection of Y capacitors combinations
• Compact and lightweight
• Operating temperature range from −25°C to +55°C
• UL, c-UL, and TÜV approved
• RoHS compliant
Part Number System
GTX-
3
300-
Y000
Series
Phase
Rated Current (A)
Class Y Capacitors
GTX
3 = Three-phase
xx0 = xx A
Y000 = None
Y103 = 10,000 pF
Y473 = 47,000 pF
Y683 = 68,000 pF
Y104 = 100,000 pF
Y474 = 470,000 pF
Built Into Tomorrow
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0011_GTX_3_PHASE • 2/4/2022
1
EMI-RFI Filters – GTX Metal Box Three-Phase Filters
Dimensions – Millimeters
±2
±1
∅5
±1
±1
.5
±2
2-
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0011_GTX_3_PHASE • 2/4/2022
2
EMI-RFI Filters – GTX Metal Box Three-Phase Filters
Environmental Compliance
KEMET GTX EMI-RFI Filters comply with EU RoHS Directive 2011/65/EU and (EU) 2015/863.
Products that fall under the exemptions listed in below table are also included.
Series
RoHS Compliant
RoHS Exemption Code
GTX
Yes
7(c)-I
Code
7(c)-I
Exemption
Electrical and electronic components containing lead in a glass
or ceramic other than dielectric ceramic in capacitors, e.g.
piezoelectronic devices, or in a glass or ceramic matrix compound
Approvals
Certification Body
File Number
Part Number
UL/cUL
E506378
All GTX Three Phase EMI-RFI Filters
TÜV Rheinland Japan Ltd.
Available by end of May 2022
All GTX Three Phase EMI-RFI Filters
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0011_GTX_3_PHASE • 2/4/2022
3
EMI-RFI Filters – GTX Metal Box Three-Phase Filters
Performance Characteristics
Item
1
Performance Characteristics
Rated Voltage
500 VAC (50/60Hz) and 500 VDC 1
Rated Current Range
30 – 60 A
Withstanding Voltage
2,800 VAC (1 minute, line to ground)
Insulation Resistance
300 MΩ minimum at 500 VDC (1 minute, line to ground)
Leakage Current Range
0.01 – 92 mA maximum at 500 V/60 Hz
Input/Output Terminal Type
Screw
Operating Temperature Range
−25°C to +55°C (not including self temperature rise)
Rated voltage AC250 / DC353.5 for c-UL approval standards.
Table 1 – Ratings & Part Number Reference
Phase
Rated
Voltage
AC/DC1 (V)
Rated
Current
AC/DC (A)
GTX-3300-Y000
Three-phase
AC500/DC500
30
0.03
60
GTX-3300-Y103
Three-phase
AC500/DC500
30
2.00
60
GTX-3300-Y473
Three-phase
AC500/DC500
30
9.00
GTX-3300-Y683
Three-phase
AC500/DC500
30
GTX-3300-Y104
Three-phase
AC500/DC500
Terminal
Type
Approval
Weight
(Kg)
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.73
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.73
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.73
13.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.74
30
20.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.74
GTX-3300-Y474
Three-phase
AC500/DC500
30
92.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.75
GTX-3400-Y000
Three-phase
AC500/DC500
40
0.03
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.74
GTX-3400-Y103
Three-phase
AC500/DC500
40
2.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.74
GTX-3400-Y473
Three-phase
AC500/DC500
40
9.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.74
GTX-3400-Y683
Three-phase
AC500/DC500
40
13.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.74
GTX-3400-Y104
Three-phase
AC500/DC500
40
20.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.74
GTX-3400-Y474
Three-phase
AC500/DC500
40
92.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.76
GTX-3500-Y000
Three-phase
AC500/DC500
50
0.03
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.71
GTX-3500-Y103
Three-phase
AC500/DC500
50
2.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.71
GTX-3500-Y473
Three-phase
AC500/DC500
50
9.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.71
GTX-3500-Y683
Three-phase
AC500/DC500
50
13.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.71
GTX-3500-Y104
Three-phase
AC500/DC500
50
20.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.71
GTX-3500-Y474
Three-phase
AC500/DC500
50
92.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.73
GTX-3600-Y000
Three-phase
AC500/DC500
60
0.03
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.68
GTX-3600-Y103
Three-phase
AC500/DC500
60
2.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.68
GTX-3600-Y473
Three-phase
AC500/DC500
60
9.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.69
GTX-3600-Y683
Three-phase
AC500/DC500
60
13.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.69
GTX-3600-Y104
Three-phase
AC500/DC500
60
20.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.69
GTX-3600-Y474
Three-phase
AC500/DC500
60
92.00
60
-25°C to +55°C
Screw
UL, c-UL, and TÜV
1.71
Temperature
Rise
Operating
Temperature
Range
Terminal
Type
Approval
Weight
Part
Number
1
Leakage Current Temperature Operating
at 500 V/
Rise (K)
Temperature
60 Hz (mA)
Maximum
Range
Maximum
Part Number
Phase
Rated
Voltage
Rated
Current
Leakage
Current
Rated voltage AC250 / DC353.5 for c-UL approval standards.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0011_GTX_3_PHASE • 2/4/2022
4
EMI-RFI Filters – GTX Metal Box Three-Phase Filters
Circuit Diagram
Circuit Diagram
EMI/EMC
Filter
Z0
P
Z0
P: Power Divider
Level Meter
Oscillator
Measuring Circuit - Common Mode
Z0
Z0: 50 Ω
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0011_GTX_3_PHASE • 2/4/2022
5
EMI-RFI Filters – GTX Metal Box Three-Phase Filters
Attenuation (Static Characteristics)
GTX-3300-Y*** Common Mode
GTX-3400-Y*** Common Mode
GTX-3500-Y*** Common Mode
GTX-3600-Y*** Common Mode
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0011_GTX_3_PHASE • 2/4/2022
6
EMI-RFI Filters – GTX Metal Box Three-Phase Filters
Packaging
Part Type
Packaging Type
Pieces per Box
GTX-3**0-Y***
Box
4
Handling Precautions
Precautions for product storage
EMI-RFI Filters should be stored in normal working environments. While the filters themselves are quite robust in other
environments, solderability will be degraded by exposure to high temperatures, high humidity, corrosive atmospheres, and
long term storage.
KEMET recommends that maximum storage temperature not exceed 40°C and maximum storage humidity not exceed 70%
relative humidity and atmospheres should be free of chlorine and sulfur bearing compounds. Temperature fluctuations
should be minimized to avoid condensation on the parts. Also, avoid storage near strong magnetic fields as this might
magnetize the product.
EMI-RFI Filters’ stock should be used promptly, preferably within 12 months of receipt.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0011_GTX_3_PHASE • 2/4/2022
7
EMI-RFI Filters – GTX Metal Box Three-Phase Filters
KEMET Electronics Corporation Sales Offices
For a complete list of our global sales offi ces, please visit www.kemet.com/sales.
Disclaimer
All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such
applications, but are not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no
obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or
property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
When providing KEMET products and technologies contained herein to other countries, the customer must abide by the procedures and provisions stipulated in all
applicable export laws and regulations, including without limitation the International Traffi c in Arms Regulations (ITAR), the US Export Administration Regulations
(EAR) and the Japan Foreign Exchange and Foreign Trade Act.
KEMET is a registered trademark of KEMET Electronics Corporation.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
ERF0011_GTX_3_PHASE • 2/4/2022
8