AC Line Filters
Common Mode SS Coils, 11V/H-CH Series
Overview
Applications
The KEMET SS Coils, SS11V/H-CH Type AC line filters are
offered in a wide variety of sizes and specifications.
• Consumer Electronics
• Common mode choke
Benefits
• Wide variety of sizes and specifications
• Inductances up to 82 mH
• Rated Currents up to 3 A
• DC Resistances as low as 0.063 Ω
H Type
nt]
ated
rrent
C(A)
0.3
0.4
0.5
0.6
0.7
0.8
1.0
1.1
1.3
1.7
2.2
3.0
0.3
0.4
0.5
0.6
0.7
0.8
1.0
1.1
DC resistance
Inductance
Temperature
(/line)
(mH)
rise(K)
max.
min.
max.
55
4.1
45
35 System
2.6
45
Part Number
23
1.8
45
18
1.3
45 03
SS
11
VR
12
0.90
45
Series
Core Size (mm)
Core Orientation
Core Type
Rated Current AC (A)
8.3
0.74
45
SS
11 = 11.0 mm
V- = Vertical
Blank = Standard
0x = 0.x A
6.2
0.44
45
H- = Horizontal
R = High
xx = x.x A
5
0.40 permeability
45
Examples:
3.5
0.28
45
03 = 0.3 A
2.4
0.19
45
13 = 1.3 A
1.3
0.12
45
0.6
0.063
45
82
4.1
45
52
2.6
45
35
1.8
45
27
1.3
45
19
0.90
45
12.5 Corporation • KEMET Tower
0.74• One East Broward Boulevard 45
© KEMET Electronics
0.44
45
Fort Lauderdale, 9.3
FL 33301 USA • 954-766-2800
• www.kemet.com
7.6
0.40
45
Weight
approx.
(g)
10.5
03 lot No.
10.7
04 lot No.
10.5
05 lot No.
11.1 CH
06 lot No.55007 lot No.
10.8
Inductance (mH) Minimum
Product Type
08 lot No.
9.8
xx0 = xx mH
CH
10 lot No.
11.1
0xx = x.x mH
11 lot No.
10.7
Examples:
13 lot No.
10.5
550 = 55 mH
17 lot No.
10.8
024 = 2.4 mH
22 lot No.
10.4
30 lot No.
9.6
R03 lot No.
10.5
R04 lot No.
10.7
R05 lot No.
10.5
R06 lot No.
11.1
R07 lot No.
10.8One KEMET
One world.
R08 lot No.
9.8
LF0023_SS11V-H-CH
• 1/31/2020
1
R10 lot No.
11.1
R11 lot No.
10.7
Marking
AC Line Filters – Common Mode SS Coils, 11V/H-CH Series
Dimensions – Millimeters
SS11H-CH
Marking
ø0.8
10 ±0.5
14.5 ±1.0
ø0.8
14 ±0.5
18 ±0.5
21 ±1.0
20.5 ±1.0
18 ±0.5
10 ±0.5
13 ±0.5
14 ±0.5
13 ±0.5
22 ±1.0
3.5 ±1.0
21.5 ±1.0
16 ±1.0
Marking
3.5 ±1.0
SS11V-CH
Environmental Compliance
All KEMET AC Line Filters are RoHS Compliant.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
LF0023_SS11V-H-CH • 1/31/2020
2
AC Line Filters – Common Mode SS Coils, 11V/H-CH Series
Table 1 – Ratings & Part Number Reference
Part Number
Rated Current
AC (A)
Inductance
(mH)
Minimum
DC Resistance/
Line (Ω)
Maximum
Temperature
Rise (K)
Maximum
Marking
Weight (g)
Approximate
SS11H-03550-CH
SS11V-03550-CH
SS11H-04350-CH
SS11V-04350-CH
SS11H-05230-CH
SS11V-05230-CH
SS11H-06180-CH
SS11V-06180-CH
SS11H-07120-CH
SS11V-07120-CH
SS11H-08083-CH
SS11V-08083-CH
SS11H-10062-CH
SS11V-10062-CH
SS11H-11050-CH
SS11V-11050-CH
SS11H-13035-CH
SS11V-13035-CH
SS11H-17024-CH
SS11V-17024-CH
SS11H-22013-CH
SS11V-22013-CH
SS11H-30006-CH
SS11V-30006-CH
SS11H-R03820-CH
SS11V-R03820-CH
SS11H-R04520-CH
SS11V-R04520-CH
SS11H-R05350-CH
SS11V-R05350-CH
SS11H-R06270-CH
SS11V-R06270-CH
SS11H-R07190-CH
SS11V-R07190-CH
SS11H-R08125-CH
SS11V-R08125-CH
SS11H-R10093-CH
SS11V-R10093-CH
SS11H-R11076-CH
SS11V-R11076-CH
SS11H-R13052-CH
SS11V-R13052-CH
SS11H-R17036-CH
SS11V-R17036-CH
SS11H-R22020-CH
SS11V-R22020-CH
SS11H-R30009-CH
SS11V-R30009-CH
0.3
0.3
0.4
0.4
0.5
0.5
0.6
0.6
0.7
0.7
0.8
0.8
1.0
1.0
1.1
1.1
1.3
1.3
1.7
1.7
2.2
2.2
3.0
3.0
0.3
0.3
0.4
0.4
0.5
0.5
0.6
0.6
0.7
0.7
0.8
0.8
1.0
1.0
1.1
1.1
1.3
1.3
1.7
1.7
2.2
2.2
3.0
3.0
55.0
55.0
35.0
35.0
23.0
23.0
18.0
18.0
12.0
12.0
8.3
8.3
6.2
6.2
5.0
5.0
3.5
3.5
2.4
2.4
1.3
1.3
0.6
0.6
82.0
82.0
52.0
52.0
35.0
35.0
27.0
27.0
19.0
19.0
12.5
12.5
9.3
9.3
7.6
7.6
5.2
5.2
3.6
3.6
2.0
2.0
0.9
0.9
4.10
4.10
2.60
2.60
1.80
1.80
1.30
1.30
0.90
0.90
0.74
0.74
0.44
0.44
0.40
0.40
0.28
0.28
0.19
0.19
0.12
0.12
0.06
0.06
4.10
4.10
2.60
2.60
1.80
1.80
1.30
1.30
0.90
0.90
0.74
0.74
0.44
0.44
0.40
0.40
0.28
0.28
0.19
0.19
0.12
0.12
0.06
0.06
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
03 Lot No.
03 Lot No.
04 Lot No.
04 Lot No.
05 Lot No.
05 Lot No.
06 Lot No.
06 Lot No.
07 Lot No.
07 Lot No.
08 Lot No.
08 Lot No.
10 Lot No.
10 Lot No.
11 Lot No.
11 Lot No.
13 Lot No.
13 Lot No.
17 Lot No.
17 Lot No.
22 Lot No.
22 Lot No.
30 Lot No.
30 Lot No.
R03 Lot No.
R03 Lot No.
R04 Lot No.
R04 Lot No.
R05 Lot No.
R05 Lot No.
R06 Lot No.
R06 Lot No.
R07 Lot No.
R07 Lot No.
R08 Lot No.
R08 Lot No.
R10 Lot No.
R10 Lot No.
R11 Lot No.
R11 Lot No.
R13 Lot No.
R13 Lot No.
R17 Lot No.
R17 Lot No.
R22 Lot No.
R22 Lot No.
R30 Lot No.
R30 Lot No.
10.5
10.5
10.7
10.7
10.5
10.5
11.1
11.1
10.8
10.8
9.8
9.8
11.1
11.1
10.7
10.7
10.5
10.5
10.8
10.8
10.4
10.4
9.6
9.6
10.5
10.5
10.7
10.7
10.5
10.5
11.1
11.1
10.8
10.8
9.8
9.8
11.1
11.1
10.7
10.7
10.5
10.5
10.8
10.8
10.4
10.4
9.6
9.6
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
LF0023_SS11V-H-CH • 1/31/2020
3
AC Line Filters – Common Mode SS Coils, 11V/H-CH Series
Performance Characteristics
Item
SS11V/H-CH
Rated Voltage
250 VAC
Withstanding Voltage
2,400 VAC (2 seconds, between lines)
Insulation Resistance
> 100 MΩ at 500 VDC (between lines)
Rated Current AC Range
0.3 – 3.0 A
Rated Inductance Range
0.6 - 82.0 mH minimum
Inductance Measurement Condition
1 kHz
Thermal Class
E (120°C)
Operating Temperature Range
−25°C to +120°C (include self temperature rise)
Common mode
Frequency
Characteristics
Frequency
characteristic
1K
100
10
1
6
3
1
6
3
Impedance ()
100K
10K
1K
100
10
1
6
3
1
6
3
Impedance ()
100K
10K
1K
100
10
0
6180
06180
3
6
1
3
10K
6
1
3
6
100K
1
3
6
1M
1
10M
Frequency (Hz)
3
100K
13035
13035
1
6
3
2
2013
22013
1
6
3
6
1
3
10K
6
1
3
6
100K
1
3
6
1M
1
10M
Frequency (Hz)
3
30M
100
100K
R07190
R07190
R10093
R
10093
R11076
R
11076
10K
1K
100
10
3
6
1
10K
3
6
1
100K
3
6
1
1M
Frequency (Hz)
3
6
1
10M
1
6
3
1
6
3
3
30M
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
08083
0
8083
07120
07120
1
6
3
1
1050
11050
1
6
3
1
6
3
1
0062
10062
3
6
1
3
10K
6
1
3
6
100K
1
3
6
1M
1
10M
Frequency (Hz)
3
30M
1
6
3
1
6
3
R03820
R03820
1
6
3
R04520
R04520
1
6
3
R06270
R06270
R05350
R05350
1
6
3
1
6
3
1
1K
R08125
R
08125
1
6
3
1
1K
1K
1M
1
6
3
1
6
3
10K
10
3
0006
30006
3
1
6
3
1
6
3
100
1
6
3
1
1K
30M
17024
1
7024
1
6
3
1
6
3
1K
1M
1
6
3
1
6
3
10K
10
1
6
3
1
1K
1M
0
5230
05230
1
6
3
1
1K
1M
100K
03550
03550
Impedance ()
10K
04350
0
4350
Impedance ()
Impedance ()
100K
1M
1
6
3
Impedance ()
1M
3
6
1
3
10K
6
1
3
6
100K
1
3
6
1M
1
10M
Frequency (Hz)
3
30M
1
6
3
1
6
3
1
6
3
R17036
R
17036
R13052
R13052
1
6
3
R
22020
R22020
1
6
3
1
6
3
1
1K
R
30009
R30009
3
6
1
10K
3
6
1
100K
3
6
1
1M
Frequency (Hz)
3
6
1
10M
3
30M
LF0023_SS11V-H-CH • 1/31/2020
4
AC Line Filters – Common Mode SS Coils, 11V/H-CH Series
Handling Precautions
Precautions for product storage
AC Line Filters should be stored in normal working environments. While the chokes themselves are quite robust in other
environments, solderability will be degraded by exposure to high temperatures, high humidity, corrosive atmospheres, and
long term storage.
KEMET recommends that maximum storage temperature not exceed 40°C and maximum storage humidity not exceed 70%
relative humidity. Atmospheres should be free of chlorine and sulfur bearing compounds. Temperature fluctuations should
be minimized to avoid condensation on the parts. Avoid storage near strong magnetic fields, as this might magnetize the
product.
For optimized solderability, AC line filters stock should be used promptly and preferably within 6 months of receipt.
Product temperature rise values
The values listed for temperature rise are the result of self-heating in wires when the rated current (commercial frequency)
is applied.
When using the product, check and evaluate the value of the core temperature rise under actual operating conditions.
Export Control
For customers in Japan
For products that are controlled items subject to the “Foreign Exchange and Foreign Trade Law” of Japan, the export license
specified by the law is required for export.
For customers outside Japan
AC line filters should not be used or sold for the use in the development, production, stockpiling, or utilization of any
conventional weapons, mass-destruction weapons (nuclear, chemical, biological weapons, or missiles), or any other
weapons.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
LF0023_SS11V-H-CH • 1/31/2020
5
AC Line Filters – Common Mode SS Coils, 11V/H-CH Series
KEMET Electronics Corporation Sales Offices
For a complete list of our global sales offi ces, please visit www.kemet.com/sales.
Disclaimer
All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such
applications, but are not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no
obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or
property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
When providing KEMET products and technologies contained herein to other countries, the customer must abide by the procedures and provisions stipulated in all
applicable export laws and regulations, including without limitation the International Traffi c in Arms Regulations (ITAR), the US Export Administration Regulations
(EAR) and the Japan Foreign Exchange and Foreign Trade Act.
KEMET is a registered trademark of KEMET Electronics Corporation.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
LF0023_SS11V-H-CH • 1/31/2020
6