Thermal Sensors
TRS Thermal Reed Switch
Overview
Applications
The TRS Thermal Reed Switch is a highly reliable, precise
temperature-sensitive switch ideal for energy conservation.
Typical applications include temperature detection and
overheat monitoring of electric appliances, heat-retention
heater control for rice cookers, defrost for air conditioners
and vending machines, roll heater temperature control for
copying machines, radiator water temperature detection for
automotive electric fan control.
Its unique proprietary design features a magnet and
a temperature-sensing soft ferromagnetic substance
called Thermorite®. The material’s magnetic flux density
decreases as the temperature increases turning it into a
paramagnetic substance at the Curie temperature.
These products have also been attested by the International
Relay Association.
Benefits
• High reliability for on/off operations
• High-speed response
• Long operational life
• Excellent environmental durability
• Extremely simple circuit design
• Compact, light and easy to handle
• Dust, explosion and corrosion-proof
• Wide range of operating temperatures available
from −10°C to +130°C
• Excellent temperature accuracy of ±2.5°C
• UL and CSA approved for TRS5***BLRU 100V
• UL approved for TRS5***BLRVU 200V
• RoHS/REACH compliant
Axial Type
Wire Harness Type
Case Type
Molded Type
Built Into Tomorrow
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
1
Thermal Sensors – TRS Thermal Reed Switch
Ordering Information
M-
TRS
Shape
3-
Maximum
Series Opening/Closing
Power (W)
Blank
M=
Mold
TRS
1 = 10.0 W
3 = 35.0 W
5 = 60.5 W
50
M
CR
00
V
U
Operating
Temperature
(°C)
Contact
Type
Shape
Classification
Lead
Type
Rated
Voltage
(VDC)
Approvals
B = Break
M = Make
Blank = Molded axial
CR = C shape fixing bar
LR = L shape fixing bar
SR = S shape
M10 = −10°C
0 = 0°C
5 = 5°C
10 = 10°C
15 = 15°C
20 = 20°C
25 = 25°C
30 = 30°C
35 = 35°C
40 = 40°C
45 = 45°C
50 = 50°C
55 = 55°C
60 = 60°C
65 = 65°C
70 = 70°C
75 = 75°C
80 = 80°C
85 = 85°C
90 = 90°C
95 = 95°C
100 = 100°C
105 = 105°C
110 = 110°C
115 = 115°C
120 = 120°C
125 = 125°C
130 = 130°C
Blank
00 = Wire
harness
01 = Lead
terminal
01E =Lead
terminal
(S shape
only)
Blank = 100 V
V = 200 V
Blank = No
approvals
U = UL and CSA
approved for
100 V and UL
approved for
200 V
Structures and Principles of Operation
Thermal Reed Switches (TRSTM) are temperature-sensing switches composed of a magnet and a temperaturesensing soft ferromagnetic substance called ThermoriteTM. This material's saturation magnetic flux density
decreases
as the temperature
increases, and itof
turns
into a paramagnetic substance at the Curie temperature.
Structures
and Principles
Operation
Thermal Reed Switches (TRS) are temperature-sensing switches composed of a magnet and a temperature-sensing soft
ferromagnetic substance called Thermorite. This material’s saturation magnetic flux density decreases as the temperature
Temperature sensing ferrite(Thermorite Ⓡ)
increases, and it turns into a paramagnetic substance at its Curie temperature.
◆ Our self-developed Themorite is temperature sensing ferrite utilizing Curie-temperature,
where ferrites lose its magnetic property.
Thermorite
properties
Thermorite
changes
its magnetic property rapidly at Curie-temperature.
of Thermorite
as temperature
sensing
material.rapidly at its Curie temperature, providing quick response times.
◆ Features
• Thermorite
changes
its magnetic
property
(1) Curie-temperature do not vary as time advances, because it depends on compounding ratio.
• The Curie temperature of Thermorite does not vary with time, as it is based on a compounding ratio.
(2) Arbitrary shape available as ceramics.
Thermorite
is stable
againstgas.
moisture and hazardous gas.
(3) • Stable
against moist
or hazardous
Thermal property of Thermorite
Permeability - temperature
TC=60
TC=90
Permeability
TC=120
4000
3000
TC=150
2000
1000
0
20
40
60
80
100
120
140
160
3500
Saturation magnetic flux density
TC=30
5000
0
Saturation magnetic flux density ‒ temperature
(1kHz-0.01Oe)
6000
3000
2500
2000
TC=150
TC=90
1500
TC=60
1000
TC=120
TC=30
500
0
0
20
40
Temperature
(℃)
60
80
100
120
140
160
Temperature(℃)
TC=Curie temperature
Encasing
Structure of reed switch
◆ Reed switch is contact switch comprised of a pair of
Fe-Ni alloy reeds encased in glass tube
with inactive gas. The reeds are switched on or off
Inactive gas
by magnetic field of permanent magnet or magnet
coil.
◆ Long lifetime, High environmental resistance
because of protected contact by glass encasing.
N
◆ Reeds in glass tube become magnetized with
S
magnetic field, and then two reeds contact and
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
connect each other (switch on). And then magnetic
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
field disappears, the reeds separate and disconnect
(switch off).
Glass tube
Contact
Fe-Ni alloy reed
S
N
N
S
SE0201_TRS • 11/2/2021
2
TC=150
2000
1000
Thermal Sensors – TRS Thermal Reed Switch 0
0
20
40
60
80
100
120
140
160
Saturation magneti
Permeabi
3000
2000
TC=60
1000
TC=120
TC=30
500
0
0
20
40
Temperature(℃)
60
80
100
120
140
160
Temperature(℃)
Structures and PrinciplesTC=Curie
of Operation
cont.
temperature
Reed switch structure
• The reed switch is a contact
switch
comprised
Structure
of reed
switch of a pair of Fe-Ni alloy
reeds encased in a glass
tube switch
with inactive
Thecomprised
reeds areofswitched
is contactgas.
switch
a pair of
◆ Reed
reeds encasedmagnet
in glass or
tube
on or off by the magneticFe-Ni
field alloy
of a permanent
magnet coil.
with inactive gas. The reeds are switched on or off
• The reeds in the glass tube
become magnetized from the magnetic
by magnetic field of permanent magnet or magnet
field, allowing the two reeds
coil.to make contact and connect (switch on).
Long lifetime,
resistance
When the magnetic field
the High
reedsenvironmental
separate and disconnect
◆disappears,
because of protected contact by glass encasing.
(switch off).
◆ Reeds in glass tube become magnetized with
• The glass encasement ofmagnetic
the reedsfield,
ensures
high environmental
and then two reeds contact and
resistance and a long operational
life.
connect each other (switch on). And then magnetic
TC=150
TC=90
1500
Encasing
Glass tube
Inactive gas
Contact
S
N
S
Fe-Ni alloy reed
N
N
S
field disappears, the reeds separate and disconnect
(switch off).
TRS principle: Break (B) type
TRS principle : Break (B) type
TRS principle : Break (B) type
( ■:Permanent magnet ■:Thermorite® ■:Reed switch contact area )
( ■:Permanent magnet ■:Thermorite® ■:Reed switch contact area )
Reset temperature
Action temperature
Reset temperature
Action temperature
Low temperature
Low temperature
Thermal magnet = paramagnet
Thermal magnet = paramagnet
N
N
S
S
S
S
N
N
S
S
N
N
S
S
N
N
S
S
N
N S
S
N
N
S
S
N
N
NEC TOKIN Sensors Vol.14 5
S
S
N
N
S N specifications
●All
in this catalog and production
products
S
N S status of N
S are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
S N
Srequest for a specification sheet N
S
N data
S prior to the purchase.
●Please
for detailed
product
●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
N
N
<Magnetic Field of Contact Part>
<Magnetic Field of Contact Part>
Magnetic Flux Forming => Reed switch ON
Magnetic Flux Forming => Reed switch ON
S
S
High temperature
High temperature
Thermal magnet = NO magnetic
Thermal magnet = NO magnetic
N
N
S
S
<Magnetic Field of Contact Part>
<Magnetic Field of Contact Part>
Magnetic Flux ≒0 => Reed switch OFF
Magnetic Flux ≒0 => Reed switch OFF
2015.3.31 0000SENVOL14E1503H1
N
N
Switch ON
Switch ON
Switch OFF
Switch OFF
TRS principle: Make (M) type
TRS principle : Make (M) type
TRS principle : Make (M) type
( ■:Permanent magnet ■:Thermorite® ■:Gapspacer(SP) ■:Reed switch contact area )
( ■:Permanent magnet ■:Thermorite® ■:Gapspacer(SP) ■:Reed switch contact area )
Reset temperature
Action temperature
Reset temperature
Action temperature
Low temperature
Low temperature
High temperature
High temperature
Thermal magnet = paramagnet
Thermal magnet = paramagnet
Thermal magnet = NO magnetic
Thermal magnet = NO magnetic
N
N
S
S
N
N
S
S
S
S
S
S
N
N
N
N
S
S
N
N
S
S
S
S
N
N
N
N
S SP N
S SP N
S SP N
S SP N
S
S
S
S
N
N
N
N
<Magnetic Field of Contact Part>
<Magnetic Field of Contact Part>
Magnetic Flux ≒0 => Reed switch OFF
Magnetic Flux ≒0 => Reed switch OFF
S
S N
N
S
S
S
S
N
N
N
N
S
S
<Magnetic Field of Contact Part>
<Magnetic Field of Contact Part>
N
N
S
S
N
N
Switch OFF
Switch OFF
N
N
S
S
Switch ON
Switch ON
6 NEC TOKIN Sensors Vol.14
6 NEC TOKIN Sensors Vol.14
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
●All
specifications
catalog and
production
status
of products
are to
subject
to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
●Please
request forinathis
specification
sheet
for detailed
product
data prior
the purchase.
●Please
request
a specification
sheet for
detailed
data prior
the purchase.
●Before using
theforproduct
in this catalog,
please
readproduct
"Precautions"
andtoother
safety precautions listed in the printed version catalog.
●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
2015.3.31 0000SENVOL14E1503H1
2015.3.31 0000SENVOL14E1503H1
SE0201_TRS • 11/2/2021
3
External magnetic field
Thermal Sensors – TRS Thermal Reed Switch
TRS/OHD installation direction in external magnetic field
External Magnetic Field
Magnetic field emitting equipment
such as motors, coils
External
magnetic
fieldequipment
Magnetic
field from
TRS/OHD
installationin
direction
in external
magnetic
TRS installation
external
magnetic
field field
Magnetic field emitting equipment
such as motors, coils
Magnetic field from equipment
Wrong direction Correct direction
N
N
S
S
Wrong direction Correct direction
N
N
S
S
S
N
N
S
S
S
N
Magnet inside TRS is
perpendicular to the external field
→ Less influence
N
Magnet inside TRS is
parallel to the external field
→ Greater Influence
Magnet inside TRS is
parallel to the external field
→ Greater Influence
Magnet inside TRS is
perpendicular to the external field
→ Less influence
Ferromagnetic material influence
Operation temperature variation (°C)
Ferromagnetic material influence
3
2
Ferromagnetic
material influence
1
-2
-3
-4
-5
Operation temperature variation (°C)
0
-1
3
BType
2
MType
1
TRS
0
-1
-2
0
BType
2
4
-3
6
8
10
12
Gap distance_d(mm)
-4
-5
14
d
MType
Soft iron (thickness 3.3mm)
16
TRS
Note; Above figures are for reference only and are not guarantee d values.d
0
2
4
6
8
10
12
Gap distance_d(mm)
14
16
Soft iron (thickness 3.3mm)
TM
Before Using Thermal Reed Switch
(TRS
)
Note; Above figures are for reference only and are not guarantee d values.
• Please ask for a copy of specification and check the contents thoroughly before the actual use.
• Please contact us before deciding your specifications.
• Do not use in close proximity to strongly magnetized
parts.
TM
Before
Thermal
Reed Switch
(TRS
)
• Do not
useUsing
if dropped
or strongly
shocked.
• Please
forgreater
a copyload
of specifi
• Do NOT
useask
with
thancation
specifiand
ed. check the contents thoroughly before the actual use.
W h•ePlease
n i nstalcontact
l i ng thesus
e sbefore
wi tchedeciding
s i n ci rcuiyour
ts prospecifi
ne to cations.
produci ng surge vol tage ( i nducti ve l oad) or rush current
• Do not
usemotors),
in closean
proximity
to strongly
magnetized
parts.
(in lamps
and
appropriate
switch type
should be
used, or a contact point protection circuit added.
• A vo•iDo
d stnot
ress use
( espifecdropped
i al l y torsor
i onstrongly
) i n case shocked.
of addi ti onal processi ng.
NOT
use with
than specifi
ed.
• Each• Do
reed
switch
has agreater
specificload
resonance
frequency.
Please contact us when an oscillation is added.
W hen i nstal l i ng these swi tches i n ci rcui ts prone to produci ng surge vol tage ( i nducti ve l oad) or rush current
(in lamps and motors), an appropriate switch type should be used, or a contact point protection circuit added.
• A voi d stress ( especi al l y torsi on) i n case of addi ti onal processi ng.
NEC TOKIN Sensors Vol.14
7
• Each reed switch has a specific resonance frequency. Please contact us when an oscillation is added.
cifications in this catalog and production status ofopr
request for a specification sheet for detailed product
d
using the product in this catalog, please read "Precau
t
ducts are subject to change without notice. Prior to the purch
a
ata prior to the purchase
.
ions" and other safety precautions listed in the printed versi
o
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
NECNEC
TOKIN
Vol.14
7 .data
se, please contact
TOKINSensors
for updated
product
n catalog.
All specifications in this catalog and production status ofopr
ducts are subject to change without notice. Prior to the purch
a
Fort
FL 33301
USAproduct
• 954-766-2800
Please request
for aLauderdale,
specification sheet
for detailed
d
ata prior •towww.kemet.com
the purchase
.
Before using the product in this catalog, please read "Precau
t
ions" and other safety precautions listed in the printed versi
o
2015.3.31 0000SENVOL14E1503H
1SE0201_TRS • 11/2/2021
se, please contact NEC TOKIN for updated product .data
n catalog.
4
Thermal Sensors – TRS Thermal Reed Switch
Dimensions – Millimeters
Part
Number
Dimensions - Millimeters
TRS5-***BLR00
TRS5-***BLR00V
TRS1-***MLR00V
TRS3-***MLR00
TRS5-***BLRU
TRS5-***BLRVU
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
5
Thermal Sensors – TRS Thermal Reed Switch
Dimensions – Millimeters cont.
Part
Number
Dimensions - Millimeters
TRS1-***MCR01V
TRS3-***MCR01
TRS5-***BCR01
TRS5-***BCR01V
TRS5-***BCR00
TRS5-***BCR00V
TRS1-***MCR00V
TRS3-***MCR00
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
6
Thermal Sensors – TRS Thermal Reed Switch
Dimensions – Millimeters cont.
Part
Number
Dimensions - Millimeters
TRS1-***MSR01EV
TRS3-***MSR01E
TRS5-***BSR01E
TRS5-***BSR01EV
M-TRS5-***B
Environmental Compliance
All KEMET Thermal Sensors are RoHS compliant.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
7
Thermal Sensors – TRS Thermal Reed Switch
Approvals
Certification Body
File Number
Part Type
UL
E67648
TRS5-***BLRU
TRS5-***BLRVU
CSA
LR50414
TRS5-***BLRU
Performance Characteristics
Item
Operations
Condition
Performance Characteristics
All types
TRS5-***BCR00, TRS5-***BLR00, TRS5-***BSR01E,
TRS5-***BLRU and TRS5-***BCR01
TRS3-***MCR00, TRS3-***MLR00,
TRS3-***MSR01E and TRS3-***MCR01
TRS5-***BCR00V, TRS5-***BLR00V,
TRS5-***BSR01EV and TRS5-***BCR01V
TRS3-***MCR00V, TRS3-***MLR00V,
TRS3-***MSR01EV and TRS1-***MCR01V
100,000 times
110 VAC – 200 Ω (purely resistive load)
110 VAC – 346 Ω (purely resistive load)
240 VAC – 1,143 Ω (purely resistive load)
200 VAC – 4,445 Ω (purely resistive load)
TRS5-***BLRVU
240 VAC – 952 Ω (purely resistive load)
M-TRS5-***B
100 VAC – 200 Ω (purely resistive load)
Judgement
All types
1) No stick
2) Contact resistance be within 500 mΩ
Dip Washing
TRS5-***BCR01, TRS3-***MCR01, TRS5-***BCR01V,
TRS1-***MCR01V and M-TRS5-***B
Using isopropyl alcohol at
normal temperature for 90 seconds
Lead Wire Material
Lead Wire Size
Lead Wire Color
TRS5-***BCR00, TRS5-***BLR00, TRS3-***MCR00,
TRS3-***MLR00, TRS5-***BCR00V, TRS5-***BLR00V,
TRS3-***MCR00V, TRS3-***MLR00V, TRS5-***BLRU
and TRS5-***BLRVU
TRS5-***BSR01E, TRS3-***MSR01E, TRS5-***BSR01EV
and TRS3-***MSR01EV
TRS5-***BCR00, TRS5-***BLR00, TRS3-***MCR00,
TRS3-***MLR00, TRS5-***BCR00V, TRS5-***BLR00V,
TRS3-***MCR00V, TRS3-***MLR00V, TRS5-***BLRU
and TRS5-***BLRVU
TRS5-***BSR01E, TRS3-***MSR01E, TRS5-***BSR01EV
and TRS3-***MSR01EV
TRS5-***BCR00, TRS5-***BLR00, TRS3-***MCR00,
TRS3-***MLR00, TRS5-***BCR00V, TRS5-***BLR00V,
TRS3-***MCR00V and TRS3-***MLR00V
TRS5-***BSR01E, TRS3-***MSR01E, TRS5-***BSR01EV
and TRS3-***MSR01EV
TRS5-***BLRU and TRS5-***BLRVU
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Silicone rubber glass braided wire
Vinyl chloride wire
0.5 mm2
0.3 mm2
Red and white
Black
White
SE0201_TRS • 11/2/2021
8
Thermal Sensors – TRS Thermal Reed Switch
Insulation & Temperature Characteristics
Shape Type
Insulation
Withstand
Voltage1
Minimum
Insulation
Resistance1
Operating
Temperature
Range
Switching
Temperature
Range
−20°C to +130°C
0°C to +130°C
Switching
Temperature
Precision2
Differential
Temperature3
±2.5°C
10°C
Maximum"
CR00
CR01
LR00
LRU
1,500 VAC/1 minute
or
1,800 VAC/1 second
500 VDC to 100 MΩ
SR01E
−20°C to +100°C
−10°C to +100°C
1,000 VAC/1 minute
or
−20°C to +150°C
−10°C to +130°C
1,200 VAC/1 second
1
Between wire harness and mounting resin surface.
2
Switching temperature precision does not include measurement error.
3
The differential temperature is also referred to as the hysteresis temperature on thermal sensors.
M-TRS
Table 1 – Ratings & Part Number Reference
Contact
Type
Maximum
Opening/
Closing
Voltage
(V)
Maximum
Opening/
Closing
Current
(A)
Maximum
Opening/
Closing
Power (W)
Minimum
Opening/
Closing
Current
Maximum
Contact
Resistance
(mΩ)
Weight
(g)
Approval
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
Part
Number
Switching
Temperature
(°C)
Maximum
Differential
Temperature
(°C)
TRS1-0MCR00V
0°C ±2.5°C
TRS1-10MCR00V
10°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-20MCR00V
20°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-30MCR00V
30°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-40MCR00V
40°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-50MCR00V
50°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-60MCR00V
60°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-70MCR00V
70°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-80MCR00V
80°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-90MCR00V
90°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-100MCR00V
100°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-110MCR00V
110°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-120MCR00V
120°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.1
-
TRS1-0MCR01V
0°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
TRS1-10MCR01V
10°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
TRS1-20MCR01V
20°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
TRS1-30MCR01V
30°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
TRS1-40MCR01V
40°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
TRS1-50MCR01V
50°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
TRS1-60MCR01V
60°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
TRS1-70MCR01V
70°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
9
Thermal Sensors – TRS Thermal Reed Switch
Table 1 – Ratings & Part Number Reference cont.
Contact
Type
Maximum
Opening/
Closing
Voltage
(V)
Maximum
Opening/
Closing
Current
(A)
Maximum
Opening/
Closing
Power (W)
Minimum
Opening/
Closing
Current
Maximum
Contact
Resistance
(mΩ)
Weight
(g)
Approval
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
100°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
Part
Number
Switching
Temperature
(°C)
Maximum
Differential
Temperature
(°C)
TRS1-80MCR01V
80°C ±2.5°C
TRS1-90MCR01V
90°C ±2.5°C
TRS1-100MCR01V
TRS1-110MCR01V
110°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
TRS1-120MCR01V
120°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
3.4
-
TRS1-0MLR00V
0°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-10MLR00V
10°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-20MLR00V
20°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-30MLR00V
30°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-40MLR00V
40°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-50MLR00V
50°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-60MLR00V
60°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-70MLR00V
70°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-80MLR00V
80°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-90MLR00V
90°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-100MLR00V
100°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-110MLR00V
110°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-120MLR00V
120°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-130MLR00V
130°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
150
8.5
-
TRS1-M10MSR01EV
-10°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-0MSR01EV
0°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-10MSR01EV
10°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-20MSR01EV
20°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-30MSR01EV
30°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-40MSR01EV
40°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-50MSR01EV
50°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-60MSR01EV
60°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-70MSR01EV
70°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-80MSR01EV
80°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-90MSR01EV
90°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS1-100MSR01EV
100°C ±2.5°C
10°C
Make
220 AC
0.045 AC
10.0 AC
1 mA/5 VDC
300
7.2
-
TRS3-0MCR00
0°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
TRS3-10MCR00
10°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
TRS3-20MCR00
20°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
TRS3-30MCR00
30°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
TRS3-40MCR00
40°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
TRS3-50MCR00
50°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
TRS3-60MCR00
60°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
TRS3-70MCR00
70°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
TRS3-80MCR00
80°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
TRS3-90MCR00
90°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
10
Thermal Sensors – TRS Thermal Reed Switch
Table 1 – Ratings & Part Number Reference cont.
Contact
Type
Maximum
Opening/
Closing
Voltage
(V)
Maximum
Opening/
Closing
Current
(A)
Maximum
Opening/
Closing
Power (W)
Minimum
Opening/
Closing
Current
Maximum
Contact
Resistance
(mΩ)
Weight
(g)
Approval
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.1
-
Part
Number
Switching
Temperature
(°C)
Maximum
Differential
Temperature
(°C)
TRS3-100MCR00
100°C ±2.5°C
TRS3-110MCR00
110°C ±2.5°C
TRS3-120MCR00
120°C ±2.5°C
TRS3-0MCR01
0°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-10MCR01
10°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-20MCR01
20°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-30MCR01
30°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-40MCR01
40°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-50MCR01
50°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
TRS3-60MCR01
60°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-70MCR01
70°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-80MCR01
80°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-90MCR01
90°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-100MCR01
100°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-110MCR01
110°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-120MCR01
120°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
3.4
-
TRS3-0MLR00
0°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-10MLR00
10°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-20MLR00
20°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-30MLR00
30°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
TRS3-40MLR00
40°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-50MLR00
50°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-60MLR00
60°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-70MLR00
70°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-80MLR00
80°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-90MLR00
90°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-100MLR00
100°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-110MLR00
110°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
TRS3-120MLR00
120°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-130MLR00
130°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
150
8.5
-
TRS3-M10MSR01E
-10°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
TRS3-0MSR01E
0°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
TRS3-10MSR01E
10°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
TRS3-20MSR01E
20°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
TRS3-30MSR01E
30°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
TRS3-40MSR01E
40°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
TRS3-50MSR01E
50°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
TRS3-60MSR01E
60°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
TRS3-70MSR01E
70°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
TRS3-80MSR01E
80°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
TRS3-90MSR01E
90°C ±2.5°C
10°C
Make
140 AC/200 DC
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
300
7.2
-
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
11
Thermal Sensors – TRS Thermal Reed Switch
Table 1 – Ratings & Part Number Reference cont.
Part
Number
Switching
Temperature
(°C)
Maximum
Differential
Temperature
(°C)
TRS3-100MSR01E
100°C ±2.5°C
10°C
TRS5-0BCR00
0°C ±2.5°C
10°C
TRS5-10BCR00
10°C ±2.5°C
10°C
Maximum
Opening/
Closing
Voltage
(V)
Maximum
Opening/
Closing
Current
(A)
Make
140 AC/200 DC
Break
140 AC/200 DC
Break
Contact
Type
Maximum
Opening/
Closing
Power (W)
Minimum
Opening/
Closing
Current
Maximum
Contact
Resistance
(mΩ)
0.500 AC/DC
35.0 AC/10.0 DC
1 mA/5 VDC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
Weight
(g)
Approval
300
7.2
-
150
6.8
-
1 mA/5 VDC
150
6.8
-
TRS5-20BCR00
20°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
-
TRS5-30BCR00
30°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
-
TRS5-40BCR00
40°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
-
TRS5-50BCR00
50°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
-
TRS5-60BCR00
60°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
-
TRS5-70BCR00
70°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
TRS5-80BCR00
80°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
-
TRS5-90BCR00
90°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
-
TRS5-100BCR00
100°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
-
TRS5-110BCR00
110°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
-
TRS5-120BCR00
120°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
6.8
-
TRS5-0BCR00V
0°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-10BCR00V
10°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-20BCR00V
20°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-30BCR00V
30°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-40BCR00V
40°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-50BCR00V
50°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-60BCR00V
60°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-70BCR00V
70°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-80BCR00V
80°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-90BCR00V
90°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-100BCR00V
100°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-110BCR00V
110°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-120BCR00V
120°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
6.8
-
TRS5-0BCR01
0°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-10BCR01
10°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-20BCR01
20°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-30BCR01
30°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-40BCR01
40°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-50BCR01
50°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-60BCR01
60°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-70BCR01
70°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-80BCR01
80°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-90BCR01
90°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-100BCR01
100°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-110BCR01
110°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-120BCR01
120°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
3.1
-
TRS5-0BCR01V
0°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
12
Thermal Sensors – TRS Thermal Reed Switch
Table 1 – Ratings & Part Number Reference cont.
Part
Number
Switching
Temperature
(°C)
Maximum
Differential
Temperature
(°C)
Contact
Type
Maximum
Opening/
Closing
Voltage
(V)
Maximum
Opening/
Closing
Current
(A)
Maximum
Opening/
Closing
Power (W)
Minimum
Opening/
Closing
Current
Maximum
Contact
Resistance
(mΩ)
Weight
(g)
Approval
TRS5-10BCR01V
10°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-20BCR01V
20°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-30BCR01V
30°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-40BCR01V
40°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-50BCR01V
50°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-60BCR01V
60°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-70BCR01V
70°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-80BCR01V
80°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-90BCR01V
90°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-100BCR01V
100°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-110BCR01V
110°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-120BCR01V
120°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
3.1
-
TRS5-0BLR00
0°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-10BLR00
10°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-20BLR00
20°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-30BLR00
30°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-40BLR00
40°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-50BLR00
50°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-60BLR00
60°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-70BLR00
70°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-80BLR00
80°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-90BLR00
90°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-100BLR00
100°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-110BLR00
110°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-120BLR00
120°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-130BLR00
130°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
7.3
-
TRS5-0BLR00V
0°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-10BLR00V
10°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-20BLR00V
20°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-30BLR00V
30°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-40BLR00V
40°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-50BLR00V
50°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-60BLR00V
60°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-70BLR00V
70°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-80BLR00V
80°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-90BLR00V
90°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-100BLR00V
100°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-110BLR00V
110°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-120BLR00V
120°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-130BLR00V
130°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
7.3
-
TRS5-0BLRU
0°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
13
Thermal Sensors – TRS Thermal Reed Switch
Table 1 – Ratings & Part Number Reference cont.
Part
Number
Switching
Temperature
(°C)
Maximum
Differential
Temperature
(°C)
Contact
Type
Maximum
Opening/
Closing
Voltage
(V)
Maximum
Opening/
Closing
Current
(A)
Maximum
Opening/
Closing
Power (W)
Minimum
Opening/
Closing
Current
Maximum
Contact
Resistance
(mΩ)
Weight
(g)
Approval
TRS5-5BLRU
5°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-10BLRU
10°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-15BLRU
15°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-20BLRU
20°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-25BLRU
25°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-30BLRU
30°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-35BLRU
35°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-40BLRU
40°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-45BLRU
45°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-50BLRU
50°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-55BLRU
55°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-60BLRU
60°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-65BLRU
65°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-70BLRU
70°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-75BLRU
75°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-80BLRU
80°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-85BLRU
85°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-90BLRU
90°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-95BLRU
95°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-100BLRU
100°C ±2.5°C
10°C
Break
140 AC
0.500 AC
50.0 AC
1 mA/5 VDC
150
8.5
UL & CSA
TRS5-0BLRVU
0°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-5BLRVU
5°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-10BLRVU
10°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-15BLRVU
15°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-20BLRVU
20°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-25BLRVU
25°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-30BLRVU
30°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-35BLRVU
35°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-40BLRVU
40°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-45BLRVU
45°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-50BLRVU
50°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-55BLRVU
55°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-60BLRVU
60°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-65BLRVU
65°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-70BLRVU
70°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-75BLRVU
75°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-80BLRVU
80°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-85BLRVU
85°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-90BLRVU
90°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-95BLRVU
95°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
TRS5-100BLRVU
100°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
150
8.5
UL
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
14
Thermal Sensors – TRS Thermal Reed Switch
Table 1 – Ratings & Part Number Reference cont.
Maximum
Differential
Temperature
(°C)
Contact
Type
Maximum
Opening/
Closing
Voltage
(V)
Maximum
Opening/
Closing
Current
(A)
Maximum
Opening/
Closing
Power (W)
Minimum
Opening/
Closing
Current
Maximum
Contact
Resistance
(mΩ)
Part
Number
Switching
Temperature
(°C)
TRS5-M10BSR01E
-10°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-0BSR01E
0°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-10BSR01E
10°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
Weight
(g)
Approval
TRS5-20BSR01E
20°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-30BSR01E
30°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-40BSR01E
40°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-50BSR01E
50°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-60BSR01E
60°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-70BSR01E
70°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-80BSR01E
80°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-90BSR01E
90°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-100BSR01E
100°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
300
6.6
-
TRS5-M10BSR01EV
-10°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-0BSR01EV
0°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-10BSR01EV
10°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-20BSR01EV
20°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-30BSR01EV
30°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-40BSR01EV
40°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-50BSR01EV
50°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-60BSR01EV
60°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-70BSR01EV
70°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-80BSR01EV
80°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-90BSR01EV
90°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
TRS5-100BSR01EV
100°C ±2.5°C
10°C
Break
264 AC
0.275 AC
60.5 AC
1 mA/5 VDC
300
6.6
-
M-TRS5-M10B
-10°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-0B
0°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-10B
10°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-20B
20°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-30B
30°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-40B
40°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-50B
50°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-60B
60°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-70B
70°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-80B
80°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-90B
90°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-100B
100°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-110B
110°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-120B
120°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
M-TRS5-130B
130°C ±2.5°C
10°C
Break
140 AC/200 DC
0.550 AC/DC
60.5 AC/10.0 DC
1 mA/5 VDC
150
4.1
-
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
15
Thermal Sensors – TRS Thermal Reed Switch
Table 2 – Ratings & Part Number Reference
Part Type
Packaging Type
LR00
CR00
LRU
LRVU
SR01E
CR01
M-TRS
Pieces per Tray
Pieces per Box
500
Rubber Band
Tray
50
600
25
30
50
500
600
1,000
Soldering
TRS1-***MCR01V, TRS3-***MCR01, TRS5-***BCR01 and TRS5-***BCR01V
Flow Soldering
Iron Soldering
Preheating Temperature
Preheating Time
Heating Temperature
Heating Time
Temperature of Tip
Worktime
100 – 150°C
Within 60 seconds
260°C
10 ±1 seconds
350°C or lower
Within 5 seconds
Preheating Temperature
Preheating Time
Heating Temperature
Heating Time
Temperature of Tip
Worktime
100 – 150°C
Within 60 seconds
260°C
10 ±1 seconds
320°C or lower
Within 4 seconds
M-TRS5-***B
Flow Soldering
Iron Soldering
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
16
Thermal Sensors – TRS Thermal Reed Switch
Marking
CR01
LR00
LOT CODE
LOT CODE
SR01E
LOT CODE
Lot Code 12345
(1) 1-3 digits
M10 = –10°C
65 = 65°C
100 = 100°C
(2) 1 digit
B = Break
M = Make
Month of the Year
(3) 1 digit
1 = January
9 = September
X = October
Y = November
Z = December
Last Digit of the Year
(4) 1 digit
0 = xxx0
1 = xxx1
9 = xxx9
(5) 0-1 digit
Blank = 100 V
V = 200 V
Operating Temperature
Contact Type
Voltage
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
17
Thermal Sensors – TRS Thermal Reed Switch
Marking cont.
LRU & LRVU
LOT CODE
Lot Code 1234556
(1) 1-3 digits
0 = 0°C
65 = 65°C
100 = 100°C
(2) 1 digit
B = Break
(3) 0-1 digit
Blank = 100 V (LRU)
G = 200 V (LRVU)
Month of the Year
(4) 1 digit
1 = January
9 = September
X = October
Y = November
Z = December
2 Last Digits of the Year
(5) 2 digits
10 = xx10
11 = xx11
19 = xx19
Factory ID
(6) 1 digit
5 = Japan
Operating Temperature
Contact Type
Contact Power
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
18
Thermal Sensors – TRS Thermal Reed Switch
Marking cont.
M-TRS
LOT CODE
Lot Code 1–2345
(1) 1 digit
Last Digit of
Part Number
(2) 1-3 digits
M10 = –10°C
60 = 60°C
100 = 100°C
(3) 1 digit
B = Break
Month of the Year
(4) 1 digit
1 = January
9 = September
X = October
Y = November
Z = December
Last Digit of the Year
(5) 1 digit
0 = xxx0
1 = xxx1
9 = xxx9
Model
Operating Temperature
Contact Type
Handling Precautions
Precautions to be taken when using Thermal Reed Switches
(Please read these precautions before using our products)
• Do NOT use in close proximity to strong magnetic parts.
• Do NOT use product under mechanical weight load.
• Do NOT use if dropped or severely shocked.
• Do NOT use with a greater load than specified.
• Avoid stress (especially torsion) in case of additional processing.
• Thermal Reed Switches have a specific resonance frequency. Please contact a KEMET representative if an oscillation is
added.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
19
Thermal Sensors – TRS Thermal Reed Switch
KEMET Electronics Corporation Sales Offices
For a complete list of our global sales offices, please visit www.kemet.com/sales.
Disclaimer
All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such
applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no
obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or
property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
When providing KEMET products and technologies contained herein to other countries, the customer must abide by the procedures and provisions stipulated in all
applicable export laws and regulations, including without limitation the International Traffic in Arms Regulations (ITAR), the US Export Administration Regulations
(EAR) and the Japan Foreign Exchange and Foreign Trade Act.
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
SE0201_TRS • 11/2/2021
20