0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
USEQGSEAC82180

USEQGSEAC82180

  • 厂商:

    KEMET(基美)

  • 封装:

  • 描述:

    二氧化碳(CO2) 传感器 I²C

  • 数据手册
  • 价格&库存
USEQGSEAC82180 数据手册
Gas Sensors QGS Pyroelectric Infrared Gas Sensors, I2C-SMD Overview Applications KEMET’s QGS thin film digital pyroelectric IR sensors for gas detection and concentration measurement combine high sensitivity with fast response times and high dynamic range to ensure rapid and accurate detection of target gases. • Gas and gas flues • HVAC (refrigerant or CO2-driven ventilation system) • Industrial process and safety • Medical capnography and anesthesia • Handheld breath analysis and breath rate measurement • Breath actuated dispenser • Automotive cabin air quality • Exhaust (CO2 content) • Home and building technology • Environmental monitoring (ambient CO2 level) • Pollution air quality in home, office and car (excessive CO2 level) These high quality sensors, in their small SMD package, integrate a digital, current mode read-out that enables lower IR-emitter duty cycles, thereby savingsignificantly on system level power consumption, while maintaining high SNR. Industry standard I2C communication enables plugand-play connectivity to microcontrollers and allows easy tuning and calibration. Programmable gain and filtering offer maximum flexibility in system design, and various optical filter options are also available. These sensors can be connected together in linear series to allow synchronized sampling across devices. Their long and maintenance-free operational lifetime makes them ideal for highly demanding automotive or medical applications. Benefits • High sensitivity with fast response time • High dynamic range • Small SMD package • I2C communication compatible • Digital output • Programmable gain and filltering • Various optical filter options • Integrated configurable amplifier, filter and ADC • Low power comsumption One world. One KEMET © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com SE0214_QGS • 4/17/2020 1 Gas Sensors – QGS Pyroelectric Infrared Gas Sensors, I2C-SMD Ordering Information USE QGS E A REF1 8 0 Product Family Series Sensor Type Mounting Type Specification Packaging Version QGS = SMD IR Gas Sensors E = Serial output M = Serial module K = Evaluation kit A = Sensor only 1 = Module type 1 3 = Kit type 3 0 = Bulk 8 = 7" Tape & Reel 0 Sensors 0000 = Fixed REF1 = Reference C821 = CO2 CH41 = CH4 N8L1 = NO 22L1 = 2.20 µm long pass 50L1 = 5.00 µm long pass 4641 = 4.64 µm Environmental Compliance All KEMET Gas Sensors are RoHS and REACH Compliant. Article 33(1) of the REACH Regulation states that manufacturers and importers of articles (products) are required to notify their customers of the presence of any Substances of Very High Concern (SVHC) in their products exceeding 0.1% by weight and provide instructions on safe use of the product. KEMET Corporation reports regarding the Article 33(1) of REACH Regulation as follows: 1. Applicable Product: Gas Sensors (QFC & QFS series) 2. Report for the content of REACH SVHC list: The product(s) above contains a substance by more than 0.1wt% per product weight that was published in the 8th update of the REACH SVHC substances (December 19, 2012). 3. Regarding the safety of the gas sensors (Piezoceramic products): The Piezoceramic that is used in this product becomes ceramic by sintering powder containing PZT as the main ingredient. It is chemically stable, with minimum risks toward the human body or environment within the intended use of the product. Please note that risks could occur in the case of inhalation or accidental oral uptake of powder ceramics. 4. Technical product information on the gas sensors (Piezoceramic products): The manufacturing technique of the “piezoceramic products” whose main ingredient is Lead Titanium Zirconium Oxide (PZT) has been established, and there is no alternative material that can exhibit superior performance than PZT at this moment. Please note that the piezoceramic is listed as an exempt on RoHS (2011/65/EU) AnnexIII (7c.1). 5. The responsibility of piezoceramic manufacturers: Piezoceramic manufacturers report information regarding PZT containment in their products to the customers to obey the article 33 of the REACH regulation. © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com SE0214_QGS • 4/17/2020 2 Gas Sensors – QGS Pyroelectric Infrared Gas Sensors, I2C-SMD Dimensions – Millimeters Sensor 1.700 0.725 3.700 28 1 15 9 Ø1.650 0.325 0.400 1.200 4.600 0.975 5.650 2.050 23 0.226 0.250 24 14 10 0.500 3.050 0.550 1.370 1.55 Maximum 24 - SYNC 25 - INT 26 - SDA 27 - SCL Pin 1 Indication 28 - GND Pin Configuration of Sensor VSupply - 1 CAP - 3 23 - CS 29 - GND GND - 5 GND - 7 21 - CLK 19 - GND 30 - GND 17 - GND TRANSPARENT TOP VIEW © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com SE0214_QGS • 4/17/2020 3 Gas Sensors – QGS Pyroelectric Infrared Gas Sensors, I2C-SMD Dimensions – Millimeters cont. Module 10.000 16.000 8.5 3.6 16 13.800 Field of View © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com SE0214_QGS • 4/17/2020 4 Gas Sensors – QGS Pyroelectric Infrared Gas Sensors, I2C-SMD Performance Characteristics Signal Filtering & Power Modes Power Mode (base sample rate) High Pass Filter – Analog (Hz) Fixed Analog Low Pass Filter (Hz) Fixed Digital Low Pass Filter (Hz) Digital Low Pass Filter (Hz) Maximum ADC Sampling Rate (sps) Normal Power Mode Off 1.0 2.0 4.0 8.0 600 250 180.0 90.0 45.0 22.5 1,000 Low Power Mode Off 0.17 0.33 0.66 1.30 100 42 30.00 15.00 7.50 3.75 166 Item Power consumption Operational state Mode Description Typical Current Consumption (1.8 V, room temperature) Normal Power Mode Normal power consumption, 1 kHz maximum sample rate 22 µA Low Power Mode Low power consumption, 166 Hz maximum sample rate 3.5 µA Normal Operation Mode Sensor signal readout over I2C 22 µA Sleep Mode Hardware interrupt on infrared trigger 21 µA (Normal Power Mode) 3.5 µA (Low Power Mode) Power Down Mode Sensor is disabled 1.1 µA Infrared Frequency Characteristics Typical Frequency Response in Normal Power Mode Typical Frequency Response in Low Power Mode © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Typical Frequency Response at Different Gain Settings SE0214_QGS • 4/17/2020 5 Gas Sensors – QGS Pyroelectric Infrared Gas Sensors, I2C-SMD Part Number Specifications Sensor Characteristics 1 Filter Aperture (mm) Element Size (mm2) SMD Package (mm) D*1 (cm√Hz/W) Typical NEP1 (W/√Hz) Typical Time Constant (ms) at 10-20 Hz peak Field of View φ 1.65 0.64 x 0.64 5.65 x 3.70 x 1.55 2.5 x 108 2.7 x 10−10 ~10 ~90° 10 Hz, 500 K, room temperature, without window and optics. Electrical Characteristics Supply Supply Voltage Current (V) (μA) Typical 1.75 to 3.60 Digital I/O I2C (FM+ compatible) 1 to 23 Part Number (Sensor) Part Number USEQFSEA391180 USEQFSEA22L180 2 USEQFSEA50L180 2 USEQFSEA464180 3 USEQGSEAC82180 USEQGSEACH4180 USEQGSEAN8L180 1 Operating Storage Temperature Temperature Range (°C) Range (°C) ΔΣ ADC at 1 ksp 15 bit −40 to +85 −40 to +110 Sensor Read-out Configurable Current mode Gain Digital filtering Sampling rate Power modes Filter (μm) Filter BW (nm) Use Weight (gr) 3.91 2.20 5.00 4.64 4.26 3.3 5.3 90 Long pass Long pass 180 180 160 180 Reference Broadband Broadband CO CO2 CH4 NO 0.07 0.07 0.07 0.07 0.07 0.07 0.07 From the QFS Flame Sensors series, used for reference. From the QFS Flame Sensors series, used with bespoke, customer or application-specific (narrowband) filters mounted externally. 3 From the QFS Flame Sensors series, used as gas or active filter. 1 2 © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com SE0214_QGS • 4/17/2020 6 Gas Sensors – QGS Pyroelectric Infrared Gas Sensors, I2C-SMD Part Number Specifications cont. Part Number (Module) Part Number USEQFSM1391100 USEQFSM122L100 2 USEQFSM150L100 2 USEQFSM1464100 3 USEQGSM1C82100 USEQGSM1CH4100 USEQGSM1N8L100 1 Comment Weight (gr) Includes sensor: USEQFSEA391180 Includes sensor: USEQFSEA22L180 Includes sensor: USEQFSEA50L180 Includes sensor: USEQFSEA464180 Includes sensor: USEQGSEAC82180 Includes sensor: USEQGSEACH4180 Includes sensor: USEQGSEAN8L180 5.40 5.40 5.40 5.40 5.40 5.40 5.40 From the QFS Flame Sensors series, used for reference. From the QFS Flame Sensors series, used with bespoke, customer or application-specific (narrowband) filters mounted externally. 3 From the QFS Flame Sensors series, used as gas or active filter. 1 2 Part Number (Evaluation Kit) Part Number Comment Weight (gr) USEQGSK3000000 USEQCSK0000000 Includes 2 sensors: USEQFSEA391180 and USEQGSEAC82180 Control board for modules, maximum 4 modules can be connected on one control board 300 250 Landing Pattern Recommended PCB Landing Pattern © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com SE0214_QGS • 4/17/2020 7 Gas Sensors – QGS Pyroelectric Infrared Gas Sensors, I2C-SMD Part Schematic Sensor Analog Front-End Reference/Regulator VDD CS INT SDA SCL Digital Filter FIFO Timing Ctrl Interrupt Ctrl Wake-up 15b ∆Σ ADC I2C Block Diagram M C U CLK SYNC Clock Generator GND VCC (1.8 - 3.6 V) >100nF Soldering Process Recommended Reflow Soldering Profile Preheat/Soak Temperature Minimum (TSmin) Temperature Maximum (TSmax) Time (ts) from Tsmin to Tsmax 150°C 200°C 60 – 120 seconds Ramp-Up Rate (TL to TP) 3°C/second maximum Time Above Liquidous (tL) 60 – 150 seconds Liquidous Temperature (TL) Peak Temperature (TP) Time within 5°C of Maximum Peak Temperature (tP)1 Ramp-Down Rate (TP to TL) Time 25°C to Peak Temperature 1 Pb-Free Assembly 217°C 260°C TP TL Temperature Profile Feature tP Maximum Ramp-up Rate = 3°C/second Maximum Ramp-down Rate = 6°C/second TC −5°C tL Tsmax Tsmin ts 25 25°C to Peak Time 30 seconds maximum 6°C/second maximum 8 minutes maximum Tolerance for peak profile temperature (TP) is defined as a supplier minimum and as a user maximum. Packaging Series Packaging Type Pieces per Reel QGS 7" Tape & Reel 800 © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com SE0214_QGS • 4/17/2020 8 Gas Sensors – QGS Pyroelectric Infrared Gas Sensors, I2C-SMD Taping Specification Dimensions (mm) Minimum Typical Maximum P0 P T P2 W A0 B0 K0 E F D0 3.90 4.00 4.10 7.90 8.00 8.10 0.25 0.30 0.35 1.90 2.00 2.10 11.70 12.00 12.30 3.90 4.00 4.10 5.85 5.95 6.05 1.65 1.75 1.85 1.65 1.75 1.85 5.40 5.50 5.60 1.50 1.50 1.60 Reel Specification Dimensions (mm) Tolerance Nominal C1 C2 A B H T D ±1.0 Ø178 ±0.2 13.5 ±0.2 2.3 ±0.2 10.4 ±0.5 12.5 ±0.2 1.6 ±0.5 Ø54 © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com SE0214_QGS • 4/17/2020 9 Gas Sensors – QGS Pyroelectric Infrared Gas Sensors, I2C-SMD Handling Precautions Pyroelectric Infrared Sensors should be kept away from indirect and direct sunlight, the headlights of cars, wind, and exposure to strong vibration and strong shock. Do not use in water, alcohol ETA, corrosive gas or under sea breeze. Do not be expose to corrosive substances. Do not drop or apply any mechanical stress. The performance of this device can be affected by ESD. Precautions should be used when handling and installing the sensor. Precision devices such as this sensor can be damaged or caused not to meet published specification due to ESD. Please note that there is limited ESD protection built-in as the device is optimised for low power consumption and low noise operation. Human Body Model (HBM), per JS-001: 2,000 V. Pyroelectric Infrared Sensors should be stored in normal working environments. Solderability will be degraded by exposure to high temperatures, high humidity, corrosive atmospheres, and long-term storage. KEMET recommends that ambient storage conditions are < 30°C and < 60% relative humidity and that maximum storage temperature does not exceed 110°C. Atmospheres should be free of chlorine and sulfur-bearing compounds. Temperature fluctuations should be minimized to avoid condensation on the parts. For optimized solderability sensors stock should be used promptly, preferably within 24 months of receipt. © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com SE0214_QGS • 4/17/2020 10 Gas Sensors – QGS Pyroelectric Infrared Gas Sensors, I2C-SMD KEMET Electronics Corporation Sales Offices For a complete list of our global sales offi ces, please visit www.kemet.com/sales. Disclaimer All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. When providing KEMET products and technologies contained herein to other countries, the customer must abide by the procedures and provisions stipulated in all applicable export laws and regulations, including without limitation the International Traffi c in Arms Regulations (ITAR), the US Export Administration Regulations (EAR) and the Japan Foreign Exchange and Foreign Trade Act. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com SE0214_QGS • 4/17/2020 11
USEQGSEAC82180 价格&库存

很抱歉,暂时无法提供与“USEQGSEAC82180”相匹配的价格&库存,您可以联系我们找货

免费人工找货
USEQGSEAC82180
  •  国内价格 香港价格
  • 800+124.44557800+15.05303

库存:0

USEQGSEAC82180
  •  国内价格 香港价格
  • 1+190.059281+22.98972
  • 10+158.3882710+19.15877
  • 25+140.2860425+16.96911
  • 100+135.75862100+16.42147

库存:0