0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MB4015ASC-1

MB4015ASC-1

  • 厂商:

    KNOWLES(楼氏)

  • 封装:

    -

  • 描述:

    MIC COND ANALOG OMNI -42DB

  • 数据手册
  • 价格&库存
MB4015ASC-1 数据手册
PRODUCT SPECIFICATION Doc: MB4015ASC-1 This specification applies to the electret condenser microphone outlined within this document. Model Number: I. MB4015ASC-1 Test Condition (Vs= 2.0 V, RL= 2.2 k ohm, Ta=20°C, RH=65%) SYMBOL S Zout I S/N (A) ΔS f=1kHz, Pin=1Pa A Curve f=1kHz, Pin=1Pa Vs= 2.0 - 1.5 Electrical Characteristics ITEM TEST CONDITION f=1KHz, Pin=1Pa f=1kHz, Pin=1Pa MINIMUM -45 STANDARD -42 MAXIMUM -39 2.2 UNITS dB 0dB=1V/Pa Sensitivity Impedance Directivity Current Consumption S/N Ratio Sensitivity Reduction Frequency Range Frequency Response kΩ mA dB dB Hz OMNI-DIRECTIONAL 0.5 55 -3 100-10,000 Schematic Diagram of Circuit II. Mechanical Characteristics ∅ Less than 4 x 1.5 0.2 g See Drawing in Section IV Dimensions Weight Solderering Heat Shock Terminal Mechanical Strength Absolute Maximum Ratings To be no interferance in operation after soldering temperature exposure at 330°C +/-10°C for below 2 seconds. To be no interference in operation after pulling terminal 0.5kg force for 1 minute Operating Voltage Vs (V) 10 Storage Temperature Operation Temperature Range Range Tope °C Tstg °C -40°C to +85°C -30°C to +70°C Issued Date: 2005/9/9 Version: B PRODUCT SPECIFICATION III. Reliability Tests Doc: MB4015ASC-1 Note: After any of the following tests performed, the sensitivity of the microphone unit shall not deviate more than ±3dB from its initial value. The microphone shall maintain its initial operation and appearance. Measurements for tests with thermal requirements are to be done after 2hrs of condistioning at 20°C. The microphone to have no interferance in operation after vibrations, 10Hz to 55Hz for 1minute full amplitude 1.52mm, for 2 hours at three axises. The microphone unit must operate when dropped three times once on each axis from a height of 1m onto a metal plate. High The microphone unit must operate within its sensitivity specifications after subjected to the following conditions: +85°C for 240 hrs, and exposed to room temperature for 2 hrs. The microphone unit must operate within its sensitivity specifications after subjected to the following conditions: -40°C for 240 hrs, and exposed to room temperature for 2 hrs. Vibration Test Drop Test Temperature Test Low Humidity Test Temperature Cycle Test +60°C at 95%RH for 240 hrs After exposure at -40°C for 45 minutes, at +85°C for 45 minutes, 27 cycles. (The measurements to be done after 2hrs of conditioning at +20°C) IV. Dimensional Drawing V. Other THD less than 2% from 100 to 10k Hz. The information contained in this literature is based on our experience to date and is believed to be reliable and it is subject to change without notice. It is intended as a guide for use by persons having technical skill at their own discretion and risk. We do not guarantee favorable results or assume any liability in connection with its use. Dimensions contained herein are for reference purposes only. For specific dimensional requirements consult factory. This publication is not to be taken as a license to operate under, or recommendation to infringe any existing patents. This supersedes and voids all previous literature. Issued Date: 2005/9/9 Version: B
MB4015ASC-1 价格&库存

很抱歉,暂时无法提供与“MB4015ASC-1”相匹配的价格&库存,您可以联系我们找货

免费人工找货
MB4015ASC-1
    •  国内价格
    • 1+31.10400
    • 200+12.40920
    • 500+11.99880
    • 1000+11.79360

    库存:0