Infrared receiver modules
KSM-71□ TE2E
The KSM-71□ TE2E consist of a PIN Photodiode of high speed and a preamplifier IC in the package as an receiver for Infrared remote control systems
DIMENSIONS
NOTE
PIN configuration ① ② ③ 71 TE5 Vout Vcc GND
(Unit : mm)
Features • One mold small size package • Wide supply-voltage range : 2.7V to 5.5V • Shielded against electrical field disturbance • High immunity against ambient light disturbances
(Logic Controller Adaptation)
• Available for carrier frequencies between 32.7KHz to 56.9KHz • TTL and CMOS compatible Applications • Audio & Video Applications (TV, VTR, Audio, DVDP, CDP) • Home Appliances (Air conditioner, Computer, Camcoder) • Wireless Toys • Remote Control Equipment Maximum Ratings
Parameter Supply Voltage Operating Temperature Storage Temperature Soldering Temperature Symbol Vcc Topr Tstg Tsol Ratings 6.0 -10 ~ +60 -20 ~ +75 260 (Max 5 sec) [Ta=25℃ ] Unit V ℃ ℃ ℃
B.P.F Center Frequency
Model No. KSM-711TE2E KSM-712TE2E KSM-713TE2E KSM-714TE2E KSM-715TE2E B.P.F Center Frequency(KHz) 40.0 36.7 37.9 32.7 56.9 [Ta=25℃ , Vcc=5.0V(Vcc=3.0V)] Typ. Max. Unit 5.5 V 1.2(1.0) 1.7 mA 940 nm 37.9 KHz m 5.0(3.0) V 0.1 600 0.5 700 700 V us us
Electro-Optical Characteristics
Parameter Recommended Supply Voltage Current Consumption Peak Wavelength *1 B.P.F Center Frequency Transmission Distance High level Output voltage Low level Output voltage *1 *1 *1 Symbol Vcc Icc λ p fo L VOH VOL TWH TWL Condition No signal input Min. 2.7 0.5 12 9 4.5(2.8) 500
250±50lx 30cm over the ray axis
0° ±30 °
High level Output Pulse Width *1 Low level Output Pulse Width *1 Output Form
Burst wave=600us Period = 1.2ms
500 600 Active Low Output
*1. It specifies the maxmum distance between emitter and detector that the output wave form satisfies the standard under the conditions below against the standard transmitter. 1) Measuring place : Indoor without extreme reflection of light high frequency lightning 3) Standard transmitter: Burst wave of standard transmitter shall be arranged to 50mVP-P under the measuring circuit 2) Ambient light source : Detecting surface illumination shall be irradiate 200±50lx under ordinary white fluorescence lamp without
1/2
Infrared receiver modules
KSM-71□ TE2E
■ Measuring Method [Ta=25℃]
Output Pulse Width
Transmitter output Carrier Frequency(fo) Duty50 % 600us 600us
Standard Transmitter
Test Method of Transmission Distance
+5V Standard Tansmitter 10㏀
Vout
Transmitter
10㏀ 10㎌ Vout
Arrival Distance : L
Remocon output pulse
OSC
GND Vcc : Indicates horizontal and vertical directions
TWL VOH VOL
TWH
25Cm
■ Typical Characteristics Curve [Ta=25℃]
Relative reception distance Vs. Supply voltage
120 ] [%
Relative reception distance Vs. Ambient temperature
120 ] [% Re lative reception distance 100 80 60 40 20 0
60˚ 80˚
Radiant pattern
Relative reception distance
100 80 60 40 20 0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 [V]
20 ˚ 40˚
0˚
-20 ˚ -40˚ -60˚ -80˚
100 ˚
0 50 100 50 100
-100˚
-10
0
10
20
30
40
50
60 [℃]
Supply voltage Vcc
Ambient temperature Ta
Relative Sensitivity [%]
■ Standard Application Circuit with R-C Decoupling Filter
R Transmitter Receiver Module Vcc Vout GND *1 Recommended Circuit Description 1) Transmitter(IRED) drive current : IFP = 300mAP-P ~ 600mAP-P 2) R-C Decoupling Filter with Lower Cut-off Frequency : R=100Ω , C=47㎌ : 10kΩ over ⇒ fc = 1/2π RC = 33.9Hz 3) External pull-up resistor(optional) Vcc C Rp micom GND