LIFCL-17-8MG121I 数据手册
CrossLink-NX Family Preliminary Data Sheet FPGA-DS-02049-0.84 December 2020 CrossLink-NX Family Preliminary Data Sheet Disclaimers Lattice makes no warranty, representation, or guarantee regarding the accuracy of information contained in this document or the suitability of its products for any particular purpose. All information herein is provided AS IS and with all faults, and all risk associated with such information is entirely with Buyer. Buyer shall not rely on any data and performance specifications or parameters provided herein. Products sold by Lattice have been subject to limited testing and it is the Buyer's responsibility to independently determine the suitability of any products and to test and verify the same. No Lattice products should be used in conjunction with mission- or safety-critical or any other application in which the failure of Lattice’s product could create a situation where personal injury, death, severe property or environmental damage may occur. The information provided in this document is proprietary to Lattice Semiconductor, and Lattice reserves the right to make any changes to the information in this document or to any products at any time without notice. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 2 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Contents Acronyms in This Document ............................................................................................................................................... 10 1. General Description .................................................................................................................................................... 11 1.1. Features ............................................................................................................................................................ 11 2. Architecture ................................................................................................................................................................ 14 2.1. Overview ........................................................................................................................................................... 14 2.2. PFU Blocks ......................................................................................................................................................... 16 2.2.1. Slice ............................................................................................................................................................... 16 2.2.2. Modes of Operation...................................................................................................................................... 19 2.2.2.1. Logic Mode ........................................................................................................................................... 19 2.2.2.2. Ripple Mode ......................................................................................................................................... 19 2.2.2.3. RAM Mode ........................................................................................................................................... 19 2.2.2.4. ROM Mode ........................................................................................................................................... 19 2.3. Routing .............................................................................................................................................................. 20 2.3.1. Clocking Structure ......................................................................................................................................... 20 2.3.2. Global PLL ..................................................................................................................................................... 20 2.3.3. Clock Distribution Network........................................................................................................................... 21 2.3.4. Primary Clocks .............................................................................................................................................. 22 2.3.5. Edge Clock ..................................................................................................................................................... 23 2.3.6. Clock Dividers................................................................................................................................................ 23 2.3.7. Clock Center Multiplexor Blocks ................................................................................................................... 24 2.3.8. Dynamic Clock Select .................................................................................................................................... 24 2.3.9. Dynamic Clock Control .................................................................................................................................. 25 2.3.10. DDRDLL ..................................................................................................................................................... 25 2.4. SGMII Clock Data Recovery (CDR) ..................................................................................................................... 26 2.5. sysMEM Memory .............................................................................................................................................. 27 2.5.1. sysMEM Memory Block ................................................................................................................................ 27 2.5.2. Bus Size Matching ......................................................................................................................................... 28 2.5.3. RAM Initialization and ROM Operation ........................................................................................................ 28 2.5.4. Memory Cascading ....................................................................................................................................... 28 2.5.5. Single, Dual and Pseudo-Dual Port Modes ................................................................................................... 28 2.5.6. Memory Output Reset .................................................................................................................................. 28 2.6. Large RAM ......................................................................................................................................................... 29 2.7. sysDSP ............................................................................................................................................................... 29 2.7.1. sysDSP Approach Compared to General DSP................................................................................................ 29 2.7.2. sysDSP Architecture Features ....................................................................................................................... 30 2.8. Programmable I/O (PIO).................................................................................................................................... 32 2.9. Programmable I/O Cell (PIC) ............................................................................................................................. 32 2.9.1. Input Register Block ...................................................................................................................................... 34 2.9.2.1. Input FIFO ............................................................................................................................................. 34 2.9.2. Output Register Block ................................................................................................................................... 35 2.10. Tristate Register Block....................................................................................................................................... 36 2.11. DDR Memory Support ....................................................................................................................................... 37 2.11.1. DQS Grouping for DDR Memory ............................................................................................................... 37 2.11.2. DLL Calibrated DQS Delay and Control Block (DQSBUF)........................................................................... 38 2.12. sysI/O Buffer...................................................................................................................................................... 40 2.12.1. Supported sysI/O Standards ..................................................................................................................... 40 2.12.2. sysI/O Banking Scheme ............................................................................................................................ 41 2.12.2.1. Typical sysI/O I/O Behavior During Power-up ...................................................................................... 42 2.12.2.2. VREF1 and VREF2 ................................................................................................................................. 42 2.12.2.3. SysI/O Standards Supported by I/O Bank ............................................................................................ 42 2.12.2.4. Hot Socketing ....................................................................................................................................... 43 2.12.3. sysI/O Buffer Configurations .................................................................................................................... 43 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 3 CrossLink-NX Family Preliminary Data Sheet 2.13. Analog Interface ................................................................................................................................................44 2.13.1. Analog to Digital Converters .....................................................................................................................44 2.13.2. Continuous Time Comparators .................................................................................................................44 2.13.3. Internal Junction Temperature Monitoring Diode ...................................................................................44 2.14. IEEE 1149.1-Compliant Boundary Scan Testability ............................................................................................44 2.15. Device Configuration .........................................................................................................................................44 2.15.1. Enhanced Configuration Options..............................................................................................................45 2.15.2.1. Dual-Boot and Multi-Boot Image Support ...........................................................................................45 2.16. Single Event Upset (SEU) Support .....................................................................................................................46 2.17. On-Chip Oscillator .............................................................................................................................................46 2.18. User I²C IP ..........................................................................................................................................................46 2.19. Density Shifting .................................................................................................................................................47 2.20. MIPI D-PHY Blocks .............................................................................................................................................47 2.21. Peripheral Component Interconnect Express (PCIe) .........................................................................................47 2.22. Cryptographic Engine ........................................................................................................................................49 3. DC and Switching Characteristics................................................................................................................................50 3.1. Absolute Maximum Ratings ..............................................................................................................................50 3.2. Recommended Operating Conditions1, 2, 3.........................................................................................................51 3.3. Power Supply Ramp Rates.................................................................................................................................52 3.4. Power up Sequence ...........................................................................................................................................52 3.5. On-Chip Programmable Termination ................................................................................................................52 3.6. Hot Socketing Specifications .............................................................................................................................53 3.7. ESD Performance...............................................................................................................................................53 3.8. DC Electrical Characteristics ..............................................................................................................................54 3.9. Supply Currents .................................................................................................................................................55 3.10. sysI/O Recommended Operating Conditions ....................................................................................................56 3.11. sysI/O Single-Ended DC Electrical Characteristics .............................................................................................57 3.12. sysI/O Differential DC Electrical Characteristics ................................................................................................59 3.12.1. LVDS ..........................................................................................................................................................59 3.12.2. LVDS25E (Output Only).............................................................................................................................60 3.12.3. SubLVDS (Input Only)................................................................................................................................61 3.12.4. SubLVDSE/SubLVDSEH (Output Only).......................................................................................................61 3.12.5. SLVS ..........................................................................................................................................................62 3.12.6. Soft MIPI D-PHY ........................................................................................................................................63 3.12.7. Differential HSTL15D (Output Only) .........................................................................................................66 3.12.8. Differential SSTL135D, SSTL15D (Output Only) ........................................................................................66 3.12.9. Differential HSUL12D (Output Only) .........................................................................................................66 3.12.10. Differential LVCMOS25D, LVCMOS33D, LVTTL33D (Output Only) ...........................................................66 3.13. CrossLink-NX Maximum sysI/O Buffer Speed ....................................................................................................67 3.14. Typical Building Block Function Performance ...................................................................................................69 3.15. Derating Timing Tables ......................................................................................................................................70 3.16. CrossLink-NX External Switching Characteristics ..............................................................................................70 3.17. CrossLink-NX sysCLOCK PLL Timing (VCC = 1.0 V) ...............................................................................................79 3.18. CrossLink-NX Internal Oscillators Characteristics ..............................................................................................80 3.19. CrossLink-NX User I2C Characteristics ...............................................................................................................80 3.20. CrossLink-NX Analog-Digital Converter (ADC) Block Characteristics .................................................................81 3.21. CrossLink-NX Comparator Block Characteristics ...............................................................................................82 3.22. CrossLink-NX Digital Temperature Readout Characteristics .............................................................................82 3.23. CrossLink-NX Hardened MIPI D-PHY Characteristics .........................................................................................82 3.24. CrossLink-NX Hardened PCIe Characteristics ....................................................................................................86 3.24.1. PCIe (2.5 Gb/s) ..........................................................................................................................................86 3.24.2. PCIe (5 Gb/s) .............................................................................................................................................88 3.25. CrossLink-NX Hardened SGMII Receiver Characteristics ...................................................................................89 3.25.1. SGMII Rx Specifications ............................................................................................................................89 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 4 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 3.26. CrossLink-NX sysCONFIG Port Timing Specifications ........................................................................................ 90 3.27. JTAG Port Timing Specifications ........................................................................................................................ 96 3.28. Switching Test Conditions ................................................................................................................................. 97 4. Pinout Information ..................................................................................................................................................... 98 4.1. Signal Descriptions* ........................................................................................................................................... 98 4.2. Pin Information Summary ............................................................................................................................... 104 4.2.1. CrossLink-NX Family .................................................................................................................................... 104 5. Ordering Information ............................................................................................................................................... 107 5.1. CrossLink-NX Part Number Description .......................................................................................................... 107 5.2. Ordering Part Numbers ................................................................................................................................... 108 5.2.1. Commercial ................................................................................................................................................. 108 5.2.2. Industrial ..................................................................................................................................................... 108 Supplemental Information ............................................................................................................................................... 110 For Further Information................................................................................................................................................ 110 Revision History ................................................................................................................................................................ 111 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 5 CrossLink-NX Family Preliminary Data Sheet Figures Figure 2.1. Simplified Block Diagram, CrossLink-NX-40 Device (Top Level) ........................................................................15 Figure 2.2. Simplified Block Diagram, CrossLink-NX-17 Device (Top Level) ........................................................................15 Figure 2.3. PFU Diagram .....................................................................................................................................................16 Figure 2.4. Slice Diagram ....................................................................................................................................................17 Figure 2.5. Slice configuration for LUT4 and LUT5 ..............................................................................................................18 Figure 2.6. General Purpose PLL Diagram...........................................................................................................................21 Figure 2.7. Clocking .............................................................................................................................................................22 Figure 2.8. Edge Clock Sources per Bank ............................................................................................................................23 Figure 2.9. DCS_CMUX Diagram .........................................................................................................................................24 Figure 2.10. DCS Waveforms ..............................................................................................................................................25 Figure 2.11. DLLDEL Functional Diagram ............................................................................................................................26 Figure 2.12. CrossLink-NX DDRDLL Architecture ................................................................................................................26 Figure 2.13. SGMII CDR IP ...................................................................................................................................................27 Figure 2.14. Memory Core Reset ........................................................................................................................................29 Figure 2.15. Comparison of General DSP and CrossLink-NX Approaches ...........................................................................30 Figure 2.16. CrossLink-NX DSP Functional Block Diagram ..................................................................................................31 Figure 2.17. Group of Two High Performance Programmable I/O Cells .............................................................................33 Figure 2.18. Wide Range Programmable I/O Cells..............................................................................................................33 Figure 2.19. Input Register Block for PIO on Top, Left, and Right Sides of the Device .......................................................34 Figure 2.20. Input Register Block for PIO on Bottom Side of the Device ............................................................................35 Figure 2.21. Output Register Block on Top, Left, and Right Sides ......................................................................................35 Figure 2.22. Output Register Block on Bottom Side ...........................................................................................................36 Figure 2.23. Tristate Register Block on Top, Left, and Right Sides ......................................................................................36 Figure 2.24. Tristate Register Block on Bottom Side ..........................................................................................................37 Figure 2.25. DQS Grouping on the Bottom Edge ................................................................................................................38 Figure 2.26. DQS Control and Delay Block (DQSBUF) .........................................................................................................39 Figure 2.27. sysI/O Banking ................................................................................................................................................42 Figure 2.28. PCIe Core.........................................................................................................................................................48 Figure 2.29. PCIe Soft IP Wrapper.......................................................................................................................................48 Figure 2.30. Cryptographic Engine Block Diagram ..............................................................................................................49 Figure 3.1. On-Chip Termination ........................................................................................................................................52 Figure 3.2. LVDS25E Output Termination Example ............................................................................................................60 Figure 3.3. SubLVDS Input Interface ...................................................................................................................................61 Figure 3.4. SubLVDS Output Interface ................................................................................................................................61 Figure 3.5. SLVS Interface ...................................................................................................................................................62 Figure 3.6. MIPI Interface ...................................................................................................................................................63 Figure 3.7. Receiver RX.CLK.Centered Waveforms .............................................................................................................76 Figure 3.8. Receiver RX.CLK.Aligned and DDR Memory Input Waveforms .........................................................................76 Figure 3.9. Transmit TX.CLK.Centered and DDR Memory Output Waveforms ...................................................................77 Figure 3.10. Transmit TX.CLK.Aligned Waveforms..............................................................................................................77 Figure 3.11. DDRX71 Video Timing Waveforms..................................................................................................................78 Figure 3.12. Receiver DDRX71_RX Waveforms ...................................................................................................................78 Figure 3.13. Transmitter DDRX71_TX Waveforms ..............................................................................................................79 Figure 3.14. Master SPI POR/REFRESH Timing....................................................................................................................91 Figure 3.15. Slave SPI/I2C/I3C POR/REFRESH Timing ..........................................................................................................92 Figure 3.16. Master SPI PROGRAMN Timing ......................................................................................................................92 Figure 3.17. Slave SPI/I2C/I3C PROGRAMN Timing .............................................................................................................93 Figure 3.18. Master SPI Configuration Timing ....................................................................................................................93 Figure 3.19. Slave SPI Configuration Timing .......................................................................................................................94 Figure 3.20. I2C /I3C Configuration Timing .........................................................................................................................94 Figure 3.21. Master SPI Wake-Up Timing ...........................................................................................................................95 Figure 3.22. Slave SPI/I2C/I3C Wake-Up Timing ..................................................................................................................95 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 6 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Figure 3.23. JTAG Port Timing Waveforms ......................................................................................................................... 96 Figure 3.24. Output Test Load, LVTTL and LVCMOS Standards .......................................................................................... 97 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 7 CrossLink-NX Family Preliminary Data Sheet Tables Table 1.1. CrossLink-NX Family Selection Guide .................................................................................................................13 Table 2.1. Resources and Modes Available per Slice ..........................................................................................................16 Table 2.2. Slice Signal Descriptions .....................................................................................................................................18 Table 2.3. Number of Slices Required to Implement Distributed RAM ..............................................................................19 Table 2.4. sysMEM Block Configurations ............................................................................................................................28 Table 2.5. Maximum Number of Elements in a sysDSP block .............................................................................................32 Table 2.6. Input Block Port Description ..............................................................................................................................34 Table 2.7. Output Block Port Description ...........................................................................................................................36 Table 2.8. Tristate Block Port Description ..........................................................................................................................37 Table 2.9. DQSBUF Port List Description.............................................................................................................................39 Table 2.10. Single-Ended I/O Standards .............................................................................................................................40 Table 2.11. Differential I/O Standards ................................................................................................................................41 Table 2.12. Single-Ended I/O Standards Supported on Various Sides ................................................................................43 Table 2.13. Differential I/O Standards Supported on Various Sides ...................................................................................43 Table 3.1. Absolute Maximum Ratings ...............................................................................................................................50 Table 3.2. Recommended Operating Conditions ................................................................................................................51 Table 3.3. Power Supply Ramp Rates .................................................................................................................................52 Table 3.4. On-Chip Termination Options for Input Modes .................................................................................................52 Table 3.5. Hot Socketing Specifications for GPIO ...............................................................................................................53 Table 3.6. DC Electrical Characteristics – Wide Range (Over Recommended Operating Conditions) ................................54 Table 3.7. DC Electrical Characteristics – High Speed (Over Recommended Operating Conditions) .................................54 Table 3.8. Capacitors – Wide Range (Over Recommended Operating Conditions) ............................................................54 Table 3.9. Capacitors – High Performance (Over Recommended Operating Conditions) ..................................................55 Table 3.10. Single Ended Input Hysteresis – Wide Range (Over Recommended Operating Conditions) ...........................55 Table 3.11. Single Ended Input Hysteresis – High Performance (Over Recommended Operating Conditions) .................55 Table 3.12. sysI/O Recommended Operating Conditions ...................................................................................................56 Table 3.13. sysI/O DC Electrical Characteristics – Wide Range I/O (Over Recommended Operating Conditions) .............57 Table 3.14. sysI/O DC Electrical Characteristics – High Performance I/O (Over Recommended Operating Conditions) ...58 Table 3.15. I/O Resistance Characteristics (Over Recommended Operating Conditions) ..................................................58 Table 3.16. LVDS DC Electrical Characteristics (Over Recommended Operating Conditions)1 ...........................................59 Table 3.17. LVDS25E DC Conditions ....................................................................................................................................60 Table 3.18. SubLVDS Input DC Electrical Characteristics (Over Recommended Operating Conditions).............................61 Table 3.19. SubLVDS Output DC Electrical Characteristics (Over Recommended Operating Conditions) ..........................61 Table 3.20. SLVS Input DC Characteristics (Over Recommended Operating Conditions) ...................................................62 Table 3.21. SLVS Output DC Characteristics (Over Recommended Operating Conditions) ................................................62 Table 3.22. Soft D-PHY Input Timing and Levels .................................................................................................................64 Table 3.23. Soft D-PHY Output Timing and Levels ..............................................................................................................65 Table 3.24. Soft D-PHY Clock Signal Specification...............................................................................................................65 Table 3.25. Soft D-PHY Data-Clock Timing Specifications ...................................................................................................66 Table 3.26. CrossLink-NX Maximum I/O Buffer Speed1, 2, 3, 4, 7 ............................................................................................67 Table 3.27. Pin-to-Pin Performance ....................................................................................................................................69 Table 3.28. Register-to-Register Performance....................................................................................................................69 Table 3.29. CrossLink-NX External Switching Characteristics (VCC = 1.0 V) .........................................................................70 Table 3.30. sysCLOCK PLL Timing (VCC = 1.0 V) ....................................................................................................................79 Table 3.31. Internal Oscillators (VCC = 1.0 V) .......................................................................................................................80 Table 3.32. User I2C Specifications (VCC = 1.0 V) ..................................................................................................................80 Table 3.33. ADC Specifications............................................................................................................................................81 Table 3.34. Comparator Specifications ...............................................................................................................................82 Table 3.35. DTR Specifications ............................................................................................................................................82 Table 3.36. Hardened D-PHY Input Timing and Levels .......................................................................................................82 Table 3.37. Hardened D-PHY Output Timing and Levels.....................................................................................................84 Table 3.38. Hardened D-PHY Pin Characteristic Specifications ..........................................................................................85 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 8 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Table 3.39. Hardened D-PHY Clock Signal Specification ..................................................................................................... 85 Table 3.40. Hardened D-PHY Data-Clock Timing Specifications ......................................................................................... 86 Table 3.41. PCIe (2.5 Gb/s) ................................................................................................................................................. 86 Table 3.42. PCIe (5 Gb/s) .................................................................................................................................................... 88 Table 3.43. SGMII Rx ........................................................................................................................................................... 89 Table 3.44. CrossLink-NX sysCONFIG Port Timing Specifications ....................................................................................... 90 Table 3.45. JTAG Port Timing Specifications ....................................................................................................................... 96 Table 3.46. Test Fixture Required Components, Non-Terminated Interfaces .................................................................... 97 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 9 CrossLink-NX Family Preliminary Data Sheet Acronyms in This Document A list of acronyms used in this document. Acronym Definition BGA CDR CRC DCC DCS DDR DLL DSP EBR ECC ECLK FFT FIFO FIR LC LRAM LVCMOS LVDS LVPECL LVTTL LUT Ball Grid Array Clock and Data Recovery Cycle Redundancy Code Dynamic Clock Control Dynamic Clock Select Double Data Rate Delay Locked Loops Digital Signal Processing Embedded Block RAM Error Correction Coding Edge Clock Fast Fourier Transforms First In First Out Finite Impulse Response Logic Cell Large RAM Low-Voltage Complementary Metal Oxide Semiconductor Low-Voltage Differential Signaling Low Voltage Positive Emitter Coupled Logic Low Voltage Transistor-Transistor Logic Look Up Table MLVDS PCI PCS PCLK PDPR PFU PIC PLL POR Multipoint Low-Voltage Differential Signaling Peripheral Component Interconnect Physical Coding Sublayer Primary Clock Pseudo Dual Port RAM Programmable Functional Unit Programmable I/O Cells Phase Locked Loops Power On Reset SCI SER SEU SLVS SPI SPR SRAM TAP TDM SERDES Client Interface Soft Error Rate Single Event Upset Scalable Low-Voltage Signaling Serial Peripheral Interface Single Port RAM Static Random-Access Memory Test Access Port Time Division Multiplexing © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 10 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 1. General Description CrossLink™-NX family of low-power FPGAs can be used in a wide range of applications, and are optimized for bridging and processing needs in Embedded Vision applications – supporting a variety of high bandwidth sensor and display interfaces, video processing and machine learning inferencing. It is built on Lattice Nexus FPGA platform, using low-power 28 nm FD-SOI technology. It combines the extreme flexibility of an FPGA with the low power and high reliability (due to extremely low SER) of FD-SOI technology, and offers small footprint package options. 1.1.   CrossLink-NX supports a variety of interfaces including MIPI D-PHY (CSI-2, DSI), LVDS, SLVS, subLVDS, PCI Express (Gen1, Gen2), SGMII (Gigabit Ethernet), and more. Processing features of CrossLink-NX include up to 39K Logic Cells, 56 18x18 multipliers, 2.9 Mb of embedded memory (consisting of EBR and LRAM blocks), distributed memory, DRAM interfaces (supporting DDR3, DDR3L, LPDDR2, and LPDDR3 up to 1066 Mbps x 16 data width). CrossLink-NX FPGAs support fast configuration of its reconfigurable SRAM-based logic fabric, and ultra-fast configuration (in under 3 ms) of its programmable sysI/O™. Security features to secure user designs include bitstream encryption and password protection. In addition to the high reliability inherent to FD-SOI technology (due to its extremely low SER), active reliability features such as built-in frame-based SED/SEC (for SRAM-based logic fabric), and ECC (for EBR and LRAM) are also supported. Built-in ADC is available in each device for system monitoring functions. Lattice Radiant™ design software allows large complex user designs to be efficiently implemented on CrossLink-NX FPGA family. Synthesis library support for CrossLink-NX devices is available for popular logic synthesis tools. Radiant tools use the synthesis tool output along with constraints from its floor planning tools, to place and route the user design in CrossLinkNX device. The tools extract timing from the routing, and back-annotate it into the design for timing verification. Lattice provides many pre-engineered IP (Intellectual Property) modules for CrossLink-NX family. By using these configurable soft IP cores as standardized blocks, you are free to concentrate on the unique aspects of your design, increasing your productivity.  Features Programmable Architecture  17K to 39K logic cells  24 to 56 18 x 18 multipliers (in sysDSP™ blocks)  2.5 to 2.9 Mb of embedded memory blocks (EBR, LRAM)  36 to 192 programmable sysI/O (High Performance and Wide Range I/O) MIPI D-PHY  Up to two hardened 4-lane MIPI D-PHY interfaces  Up to eight lanes total  Transmit or receive  Supports CSI-2, DSI  20 Gbps aggregate bandwidth  2.5 Gbps per lane, 10 Gbps per D-PHY interface  Additional Soft D-PHY interfaces supported by High Performance (HP) sysI/O  Transmit or receive  Supports CSI-2, DSI  Up to 1.5 Gbps per lane Programmable sysI/O supports wide variety of interfaces  High Performance (HP) on bottom I/O dual rank  Supports up to 1.8 V VCCIO  Mixed voltage support (1.0 V, 1.2 V, 1.5 V, 1.8 V)  High-speed differential up to 1.5 Gbps  Supports soft D-PHY (Tx/Rx), LVDS 7:1 (Tx/Rx), SLVS (Tx/Rx), subLVDS (Rx)  Supports SGMII (Gb Ethernet) – 2 channels (Tx/Rx) at 1.25 Gbps  Dedicated DDR3/DDR3L and LPDDR2/LPDDR3 memory support with DQS logic, up to 1066 Mbps data-rate and x16 data-width  Wide Range (WR) on Left, Right and Top I/O Banks  Supports up to 3.3 V VCCIO  Mixed voltage support (1.2 V, 1.5 V, 1.8 V, 2.5 V, 3.3 V)  Programmable slew rate (slow, med, fast)  Controlled impedance mode  Emulated LVDS support  Hot-socketing © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 11 CrossLink-NX Family Preliminary Data Sheet         Power Modes – Low Power versus HighPerformance  User selectable  Low-Power mode for power and/or thermal challenges  High-Performance mode for faster processing Small footprint package options  4 x 4 mm2 to 10 x 10 mm2 package options 2x SGMII CDR at up to 1.25 Gbps – to support 2 channels SGMII using HP I/O  CDR for RX  8b/10b decoding  Independent Loss of Lock (LOL) detector for each CDR block sysCLOCK™ analog PLLs  Three in 39K LC and two in 17K LC device  Six outputs per PLL  Fractional N  Programmable and dynamic phase control sysDSP Enhanced DSP blocks  Hardened pre-adder  Dynamic Shift for AI/ML support  Four 18 x 18, eight 9 x 9, two 18 x 36, or 36 x 36  Advanced 18 x 36, two 18 x 18, or four 8 x 8 MAC Flexible memory resources  Up to 1.5 Mb sysMEM™ Embedded Block RAM (EBR)  Programmable width  ECC  FIFO  80k to 240k bits distributed RAM  Large RAM Blocks  0.5 Mbits per block  Up to five blocks (2.5 Mb total) per device SERDES – PCIe Gen2 x1 channel (Tx/Rx) hard IP in 39K LC device  Hard IP supports  Gen1, Gen2, Multi-Function, End Point, Root Complex  APB control bus  AHB-Lite for data bus      Configuration – Fast, Secure  SPI – x1, x2, x4 up to 150 MHz  Master and Slave SPI support  JTAG  I2C and I3C  Ultrafast I/O configuration for instant-on support  Less than 15 ms full device configuration for LIFCL-40  Bitstream Security  Encryption Cryptographic engine  Bitstream encryption – using AES-256  Bitstream authentication – using ECDSA  Hashing algorithms – SHA, HMAC  True Random Number Generator  AES 128/256 Encryption Single Event Upset (SEU) Mitigation Support  Extremely low Soft Error Rate (SER) due to FDSOI technology  Soft Error Detect – Embedded hard macro  Soft Error Correction – Without stopping user operation  Soft Error Injection – Emulate SEU event to debug system error handling ADC – 1 MSPS, 12-bit SAR  2 ADCs per device  3 Continuous-time Comparators  Simultaneous sampling System Level Support  IEEE 1149.1 and IEEE 1532 compliant  Reveal Logic Analyzer  On-chip oscillator for initialization and general use  1.0 V core power supply Internal bus interface support  APB control bus  AHB-Lite for data bus  AXI4-streaming © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 12 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Table 1.1. CrossLink-NX Family Selection Guide CrossLink-NX Family: Device Logic Cells¹ Embedded Memory (EBR) Blocks (18 Kb) Embedded Memory (EBR) Bits (Kb) Distributed RAM Bits (Kb) Large Memory (LRAM) Blocks Large Memory (LRAM) Bits (Kb) 18 X 18 Multipliers ADC Blocks 450 MHz High Frequency Oscillator 128 KHz Low Power Oscillator GPLL Hardened 10 Gbps D-PHY Quads² Hardened 2.5 Gbps D-PHY Data Lanes (total)² PCIe Gen2 Hard IP Packages (Size, Ball Pitch) 72 wlcsp (3.7 x 4.1 mm2, 0.4 mm) 72 QFN (10 x 10 mm2, 0.5 mm) 121 csfBGA (6 x 6 mm2, 0.5 mm) 256 caBGA (14 x 14 mm2, 0.8 mm) LIFCL-17 LIFCL-40 17K 39K 24 84 432 1,512 80 240 5 2 2560 1024 24 56 2 2 1 1 1 1 2 3 2 2 8 8 — 1 D-PHY Quads (D-PHY Data Lanes) / Wide Range (WR) GPIOs (Top/Left/Right Banks) / High Performance (HP) GPIOs (Bottom Banks) 1(4)/15/24 — 1(4)/17/22 1(4)/17/22 2(8)/23/48 2(8)/23/48 2(8)/29/48 2(8)/88/74, PCIe x1 289 csBGA (9.5 x 9.5 mm2, 0.5 mm) — 400 caBGA (17 x 17 mm², 0.8 mm) — Notes: 1. Logic Cells = LUTs x 1.2 effectiveness. 2. Additional soft D-PHY Tx/Rx interfaces (at up to 1.5 Gbps per lane) are available using sysI/O. 2(8)/105/74, PCIe x1 2(8)/117/74, PCIe x1 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 13 CrossLink-NX Family Preliminary Data Sheet 2. Architecture 2.1. Overview Each CrossLink-NX device contains an array of logic blocks surrounded by Programmable I/O Cells (PIC). Interspersed between the rows of logic blocks are rows of sysMEM Embedded Block RAM (EBR) and rows of sysDSP Digital Signal Processing blocks, as shown in Figure 2.1. The CrossLink-NX-40 devices have two rows of DSP blocks and contain three rows of sysMEM EBR blocks. In addition, CrossLink-NX-40 devices includes two Large SRAM blocks. The sysMEM EBR blocks are large, dedicated 18 Kb fast memory blocks and have built-in ECC and FIFO support. Each sysMEM block can be configured to a single, pseudo dual or true dual port memory in a variety of depths and widths as RAM or ROM. Each DSP block supports variety of multiplier, adder configurations with one 108-bit or two 54-bit accumulators supported, which are the building blocks for complex signal processing capabilities. Each PIC block encompasses two PIO (PIO pairs) with their respective sysI/O buffers. The sysI/O buffers of the CrossLink-NX devices are arranged in seven banks allowing the implementation of a wide variety of I/O standards. The Wide Range (WR) I/O banks that are located in the top, left and right sides of the device provide flexible ranges of general purpose I/O configurations up to 3.3 V VCCIOs. The banks located in the bottom side of the device are dedicated to High Performance (HP) interfaces such as LVDS, MIPI, DDR3, LPDDR2, and LPDDR3 supporting up to 1.8 V VCCIOs. The Programmable Functional Unit (PFU) contains the building blocks for logic, arithmetic, RAM and ROM functions. The PFU block is optimized for flexibility, allowing complex designs to be implemented quickly and efficiently. Logic Blocks are arranged in a two-dimensional array. The registers in PFU and sysI/O blocks in CrossLink-NX devices can be configured to be SET or RESET. After power up and the device is configured, it enters into user mode with these registers SET/RESET according to the configuration setting, allowing the device entering to a known state for predictable system function. In addition, CrossLink-NX-40 devices provide various system level hard IP functional and interface blocks such as PCIe, D-PHY, I2C, SGMII/CDR, and ADC blocks. PCIe hard IP supports PCIe 2.0 and D-PHY supports up to 2.5 Gbps per lane. CrossLink-NX devices also provide security features to help secure user designs and deliver more robust reliability features to the user designs by using enhanced frame-based SED/SEC functions. Other blocks provided include PLLs, DLLs, and configuration functions. The PLL and DLL blocks are located at the corners of each device. CrossLink-NX devices also include Lattice Memory Mapped Interface (LMMI) which is a Lattice standardized interface for simple read and write operations to support controlling internal IPs. Every device in the family has a JTAG port. This family also provides an on-chip oscillator and soft error detect capability. The CrossLink-NX devices use 1.0 V as their core voltage. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 14 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet I/O Bank (Bank 0) PLL D-PHY (4 Lanes) D-PHY (4 Lanes) PCIe OSC Configuration & Security I/O Bank (Bank 7) I/O Bank (Bank 1) Large RAM Large RAM I/O Bank (Bank 6) I/O Bank (Bank 2) ADC (2Ch) CDR (2Ch) PLL I/O Bank (Bank 5) I/O Bank (Bank 4) I/O Bank (Bank 3) PLL Figure 2.1. Simplified Block Diagram, CrossLink-NX-40 Device (Top Level) I/O Bank (Bank 0) D-PHY (4 Lanes) D-PHY (4 Lanes) OSC Configuration and Security Large RAM I/O Bank (Bank 1) Large RAM Large RAM Large RAM Large RAM ADC (2Ch) CDR (2Ch) PLL I/O Bank (Bank 5) I/O Bank (Bank 4) I/O Bank (Bank 3) PLL Figure 2.2. Simplified Block Diagram, CrossLink-NX-17 Device (Top Level) © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 15 CrossLink-NX Family Preliminary Data Sheet 2.2. PFU Blocks The core of the CrossLink-NX device consists of PFU blocks. Each PFU block consists of four interconnected slices numbered 0-3 as shown in Figure 2.3. Each slice contains two LUTs. All the interconnections to and from PFU blocks are from routing. The PFU block can be used in Distributed RAM or ROM function, or used to perform Logic, Arithmetic, or ROM functions. Table 2.1 shows the functions each slice can perform in either mode. From Routing LUT4 & CARRY LUT4 & CARRY LUT4 & CARRY Slice 0 LUT4 & CARRY Slice 1 D FF LUT4 & CARRY D FF LUT4 & CARRY D D FF D D FF LUT4 & CARRY Slice 3 Slice 2 D FF LUT4 & CARRY FF FF D FF To Routing Figure 2.3. PFU Diagram 2.2.1. Slice Each slice contains two LUT4s feeding two registers. In Distributed SRAM mode, Slice 0 and Slice 1 are configured as distributed memory, and Slice 2 is not available as it is used to support Slice 0 and Slice 1 while Slice 3 is available as Logic or ROM. Table 2.1 shows the capability of the slices along with the operation modes they enable. In addition, each Slice contains logic that allows the LUTs to be combined to perform a LUT5 function. There is control logic to perform set/reset functions (programmable as synchronous/ asynchronous), clock select, chip-select, and wider RAM/ROM functions. Table 2.1. Resources and Modes Available per Slice Slice Slice 0 Slice 1 Slice 2 Slice 3 PFU (Used in Distributed SRAM) Resources Modes 2 LUT4s and 2 Registers RAM 2 LUT4s and 2 Registers RAM 2 LUT4s and 2 Registers RAM 2 LUT4s and 2 Registers Logic, Ripple, ROM PFU (Not used as Distributed SRAM) Resources Modes 2 LUT4s and 2 Registers Logic, Ripple, ROM 2 LUT4s and 2 Registers Logic, Ripple, ROM 2 LUT4s and 2 Registers Logic, Ripple, ROM 2 LUT4s and 2 Registers Logic, Ripple, ROM Figure 2.4 shows an overview of the internal logic of the slice. The registers in the slice can be configured for positive/negative edge trigger. Each slice has 17 input signals: 16 signals from routing and one from the carry-chain (from the adjacent slice or PFU). Three of them are used for FF control and shared between two slices (0/1 or 2/3). There are five outputs: four to routing and one to carry-chain (to the adjacent PFU). Table 2.2 and Figure 2.4 list the signals associated with all the slices. Figure 2.5 shows the slice signals that support a LUT5 or two LUT5 functions. F0 can be configured to have a LUT4 or LUT5 output while F1 is for a LUT4 output. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 16 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet LUT5 and Carry Figure 2.4. Slice Diagram © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 17 CrossLink-NX Family Preliminary Data Sheet A1 F1 B1 LUT4 C1 D1 1 F0 0 SEL A0 B0 LUT4 C0 D0 *Note: In RAM mode, LUT4s use the following signals: QWD0/1 QWDN0/1 QWAS00~03, QWAS10~13 Figure 2.5. Slice configuration for LUT4 and LUT5 Table 2.2. Slice Signal Descriptions Function Input Input Input Input Input Input Input Input Input Output Output Output Output Type Data signal Data signal Data signal Control signal Data signal Control signal Control signal Control signal Inter-PFU signal Data signals Data signals Data signals Inter-PFU signal Signal Names A0, B0, C0, D0 A1, B1, C1, D1 M0, M1 SEL DI0, DI1 CE LSR CLKIN FCI F0 F1 Q0, Q1 FCO Description Inputs to LUT4 Inputs to LUT4 Direct input to FF from fabric LUT5 mux control input Inputs to FF from LUT4 F0/F1 outputs Clock Enable Local Set/Reset System Clock Fast Carry-in1 LUT4/LUT5 output signal LUT4 output signal Register outputs Fast carry chain output1 Note: See Figure 2.4 for connection details. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 18 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 2.2.2. Modes of Operation Slices 0-2 have up to four potential modes of operation: Logic, Ripple, RAM and ROM. Slice 3 is not needed for RAM mode, it can be used in Logic, Ripple, or ROM modes. 2.2.2.1. Logic Mode In this mode, the LUTs in each slice are configured as 4-input combinatorial lookup tables. A LUT4 can have 16 possible input combinations. Any four input logic functions can be generated by programming this lookup table. Since there are two LUT4s per slice, a LUT5 can be constructed within one slice. 2.2.2.2. Ripple Mode Ripple mode supports the efficient implementation of small arithmetic functions. In ripple mode, the following functions can be implemented by each slice:  Addition 2-bit  Subtraction 2-bit  Add/Subtract 2-bit using dynamic control  Up counter 2-bit  Down counter 2-bit  Up/Down counter with asynchronous clear 2-bit using dynamic control  Up/Down counter with preload (sync) 2-bit using dynamic control  Comparator functions of A and B inputs 2-bit  A greater-than-or-equal-to B  A not-equal-to B  A less-than-or-equal-to B  Up/Down counter with A greater-than-or-equal-to B comparator 2-bit using dynamic control  Up/Down counter with A less-than-or-equal-to B comparator 2-bit using dynamic control  Multiplier support Ai*Bj+1 + Ai+1*Bj in one logic cell with 2 logic cells per slice  Serial divider 2-bit mantissa, shift 1bit/cycle  Serial multiplier 2-bit, shift 1bit/cycle or 2bit/cycle Ripple Mode includes an optional configuration that performs arithmetic using fast carry chain methods. In this configuration (also referred to as CCU2 mode) two additional signals, Carry Generate and Carry Propagate, are generated on a per slice basis to allow fast arithmetic functions to be constructed by concatenating Slices. 2.2.2.3. RAM Mode In this mode, a 16 x 4-bit distributed single or pseudo dual port RAM can be constructed in one PFU using each LUT block in Slice 0 and Slice 1 as a 16 x 2-bit memory in each slice. Slice 2 is used to provide memory address and control signals. CrossLink-NX devices support distributed memory initialization. The Lattice design tools support the creation of a variety of different size memories. Where appropriate, the software constructs these using distributed memory primitives that represent the capabilities of the PFU. Table 2.3 lists the number of slices required to implement different distributed RAM primitives. For more information about using RAM in CrossLink-NX devices, refer to CrossLink-NX Memory Usage Guide (FPGA-TN-02094). Table 2.3. Number of Slices Required to Implement Distributed RAM Number of slices Note: SPR = Single Port RAM, PDPR = Pseudo Dual Port RAM SPR 16 X 4 3 PDPR 16 X 4 3 2.2.2.4. ROM Mode ROM mode uses the LUT logic; hence, Slice 0 through Slice 3 can be used in ROM mode. Preloading is accomplished through the programming interface during PFU configuration. For more information, refer to CrossLink-NX Memory Usage Guide (FPGA-TN-02094). © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 19 CrossLink-NX Family Preliminary Data Sheet 2.3. Routing There are many resources provided in the CrossLink-NX devices to route signals individually or as busses with related control signals. The routing resources consist of switching circuitry, buffers and metal interconnect (routing) segments. The CrossLink-NX family has an enhanced routing architecture that produces a compact design. The Radiant software tool suites take the output of the synthesis tool and places and routes the design. 2.3.1. Clocking Structure The CrossLink-NX clocking structure consists of clock synthesis blocks, sysCLOCK PLL; balanced clock tree networks, PCLK and ECLK; and efficient clock logic modules, Clock Dividers (PCLKDIV and ECLKDIV) and Dynamic Clock Select (DCS), Dynamic Clock Control (DCC), and DLL. Each of these functions is described as follow. 2.3.2. Global PLL The Global PLLs (GPLL) provide the ability to synthesize clock frequencies. The devices in the CrossLink-NX family support two or three full-featured General Purpose GPLLs. The Global PLLs provide the ability to synthesize clock frequencies. The architecture of the GPLL is shown in Figure 2.6. A description of the GPLL functionality follows. REFCK is the reference frequency input to the PLL and its source can come from external CLK inputs or from internal routing. The CLKI input feeds into the input Clock Divider block. CLKFB is the feedback signal to the GPLL which can come from internal feedback path or routing. The feedback divider is used to multiply the reference frequency and thus synthesize a higher or lower frequency clock output. The PLL has six clock outputs CLKOP, CLKOS, CLKOS2, CLKOS3, CLKOS4, and CLKOS5. Each output has its own output divider, thus allowing the GPLL to generate different frequencies for each output. The output dividers can have a value from 1 to 128. Each GPLL output can be used to drive the primary clock or edge clock networks. The setup and hold times of the device can be improved by programming a phase shift into the output clocks which advances or delays the output clock with reference to the un-shifted output clock. This phase shift can be either programmed during configuration or can be adjusted dynamically using the DIRSEL, DIR, DYNROTATE, and LOADREG ports. The LOCK signal is asserted when the GPLL determines it has achieved lock and de-asserted if a loss of lock is detected. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 20 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet (To bypass muxes) Figure 2.6. General Purpose PLL Diagram For more details on the PLL, you can refer to the CrossLink-NX sysCLOCK PLL/DLL Design and Usage Guide (FPGA-TN02095). 2.3.3. Clock Distribution Network There are two main clock distribution networks for any member of the CrossLink-NX product family, namely Primary Clock (PCLK) and Edge Clock (ECLK). These clock networks can be driven from many different sources, such as Clock Pins, PLL outputs, DLLDEL outputs, Clock divider outputs, SERDES/PCS clocks and user logic. There are clock divider blocks (ECLKDIV and PCLKDIV) to provide a slower clock from these clock sources. CrossLink-NX supports glitchless Dynamic Clock Control (DCC) for the PCLK Clock to save dynamic power. There are also Dynamic Clock Selection logic to allow glitchless selection between two clocks for the PCLK network (DCS). Overview of Clocking Network is shown in Figure 2.7 for CrossLink-NX device. The shaded blocks (PCIe and upper left PLL) are not available in the 17K Logic Cell device. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 21 CrossLink-NX Family Preliminary Data Sheet PLL MIPI_DPHY0 MIPI_DPHY1 BANK 0 PCLK OSC TMID BANK 1 PCLK RMID LMID 16 DCC 12 DCC BANK 2 PCLK 18 DCC BMID PLL BANK 5 PCLK ECLK BANK 4 PCLK ECLK BANK 3 PCLK ECLK PLL Figure 2.7. Clocking 2.3.4. Primary Clocks The CrossLink-NX device family provides low-skew, high fan-out clock distribution to all synchronous elements in the FPGA fabric through the Primary Clock Network. The CrossLink-NX PCLK clock network is a balanced clock structure which is designed to minimize the clock skew among all the final destination of the IPs in the FPGA core that needs a clock source. The primary clock network is divided into two clock domains depending on the device density. Each of these domains has 16 clocks that can be distributed to the fabric in the domain. The Lattice Radiant software can automatically route each clock to one of the domains up to a maximum of 16 clocks per domain. You can change how the clocks are routed by specifying a preference in the Lattice Radiant software to locate the clock to a specific domain. The CrossLink-NX device provides you with a maximum of 64 unique clock input sources that can be routed to the primary Clock network. Primary clock sources are:  Dedicated clock input pins  PLL outputs  PCLKDIV, ECLKDIV outputs  Internal FPGA fabric entries (with minimum general routing)  SGMII-CDR, D-PHY, PCIe clocks  OSC clock These sources are routed to each of four clock switches called a Mid Mux (LMID, RMID, TMID, BMID). The outputs of the Mid MUX are routed to the center of the FPGA where additional clock switches (DSC_CMUX) are used to route the primary clock sources to primary clock distribution to the CrossLink-NX fabric. These routing muxs are shown in Figure 2.7. There are potentially 64 unique clock domains that can be used in the largest CrossLink-NX Device. For more information about the primary clock tree and connections, refer to CrossLink-NX sysCLOCK PLL/DLL Design and Usage Guide (FPGA-TN-02095). © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 22 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 2.3.5. Edge Clock CrossLink-NX devices have a number of high-speed edge clocks that are intended for use with the PIO in the implementation of high-speed interfaces. There are four (4) ECLK networks per bank I/O on the Bottom side of the devices. For power management, the Edge clock network is powered by a separate power domain (to reduce power noise injection from the core and reduce overall noise induced jitter) while controlled by the same logic that gates the FPGA core and PCLK domains. Each Edge Clock can be sourced from the following:  Dedicated PIO Clock input pins (PCLK)  DLLDEL output (PIO Clock delayed by 90°)  PLL outputs (CLKOP, CLKOS, CLKOS2, CLKOS3, CLKOS4, and CLKOS5)  Internal Nodes Figure 2.8 illustrates the various ECLK sources. Bank 3 is shown in the example. Bank 4 and Bank 5 are similar. Bank 3 PCLK Pin (even) 2 From Banks 4, 5 ECLKSYNC DLLDEL Bottom Left GPLL 6 Bank 3 ECLK Tree From Fabric ECLKSYNC ECLKDIV Bottom Right GPLL Bank 3 PCLK Pin (odd) BMID 6 2 To Banks 4,5 Muxes Figure 2.8. Edge Clock Sources per Bank The edge clocks have low injection delay and low skew. They are typically used for DDR Memory or Generic DDR interfaces. For detailed information on Edge Clock connections, refer to CrossLink-NX sysCLOCK PLL/DLL Design and Usage Guide (FPGA-TN-02095). 2.3.6. Clock Dividers CrossLink-NX devices have two distinct types of clock divider, Primary and Edge. There are from one (1) to eight (8) Primary Clock Divider (PCLKDIV) and which are located in the DCS_CMUX block(s) at the center of the device. There are twelve (12) ECLKDIV dividers per device, locate near the bottom high-speed I/O banks. The PCLKDIV supports ÷2, ÷4, ÷8, ÷16, ÷32, ÷64, ÷128, and ÷1 (bypass) operation. The PCLKDIV is fed from a DCSMUX within the DCS_CMUX block. The clock divider output drives one input of the DCS Dynamic Clock Select within the DSC_CMUX block. The Reset (RST) control signal is asynchronously and forces all outputs to low. The divider output starts at next cycle after the reset is synchronously released. The PCLKDIV is shown in context in Figure 2.9. The ECLKDIV is intended to generate a slower-speed system clock from a high-speed edge clock. The block operates in a ÷2, ÷3.5, ÷4, or ÷5 mode and maintains a known phase relationship between the divided down clock and the highspeed clock based on the release of its reset signal. The ECLKDIV can be fed from selected PLL outputs, external primary clock pins (with or without DLLDEL Delay) or from routing. The clock divider outputs feed into the Bottom Mid-mux (BMID). The Reset (RST) control signal is asynchronously and forces all outputs to low. The divider output starts at next cycle after the reset is synchronously released. The ECLKDIV block is shown in context in Figure 2.8. For further information on clock dividers, refer to CrossLink-NX sysCLOCK PLL/DLL Design and Usage Guide (FPGA-TN-02095). © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 23 CrossLink-NX Family Preliminary Data Sheet 2.3.7. Clock Center Multiplexor Blocks All clock sources are selected and combined for primary clock routing through the Dynamic Clock Selector Center Multiplexor logic (DCS_CMUX). There are one (1) or two (2) DCS_CMUX blocks per device. Each DCS_CMUX block contains 2 DCSMUX blocks, 1 PCLKDIV, 1 DCS block, and 1 or 2 CMUX blocks. See Figure 2.9 for a representative DCS_CMUX block diagram. The heart of the DCS_CMUX is the Center Multiplexor (CMUX) block, inputs up to 64 feed clock sources (Mid-muxes (RMID, LMID, TMIC, BMID) and DCC) and to drive up to 16 primary clock trunk lines. Up to two (2) clock inputs to the DCS_CMUX can be routed through a Dynamic Clock Select block then routed to the CMUX. One (1) input to the DCS can be optionally divided by the Primary Clock Divider (PCLKDIV). For more information about the DCS_CMUX, refer to CrossLink-NX sysCLOCK PLL/DLL Design and Usage Guide (FPGA-TN-02095). 16 16 16 16x (partial 16x (partial (16/64):1) (16/64):1) CMUX CMUX 16 DCS_CMUX dcs2cmux0 DCS 62 dcs1 dcs0 PCLKDIV DCMUX (62:1) DCMUX (62:1) 62 62 62 62 62 Figure 2.9. DCS_CMUX Diagram 2.3.8. Dynamic Clock Select The Dynamic Clock Select (DCS) is a smart multiplexer function available in the primary clock routing. It switches between two independent input clock sources. Depending on the operation modes, it switches between two (2) independent input clock sources either with or without any glitches. This is achieved regardless of when the select signal is toggled. Both input clocks must be running to achieve functioning glitchless DCS output clock, but running clocks are not required when used as non-glitchless normal clock multiplexer. There are one (1) or two (2) DCS blocks per device that feed all clock domains. The DCS blocks are located in the DCS_MUX block. The inputs to the DCS blocks come from MIDMUX outputs and user logic clocks via DCC elements. The DCS elements are located at the center of the PLC array core. The output of the DCS is connected to the inputs of Primary Clock Center MUXs (CMUX). Figure 2.10 shows the timing waveforms of the default DCS operating mode. The DCS block can be programmed to other modes. For more information about the DCS, refer to CrossLink-NX sysCLOCK PLL/DLL Design and Usage Guide (FPGA-TN-02095). © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 24 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet CLK0 clk0 pos CLK1 clk1 pos SEL clk1 neg clk0 neg DCSOUT Figure 2.10. DCS Waveforms 2.3.9. Dynamic Clock Control The Dynamic Clock Control (DCC), Domain Clock enable/disable feature allows internal logic control of the domain primary clock network. When a clock network is disabled, the clock signal is static and not toggle. All the logic fed by that clock does not toggle, reducing the overall power consumption of the device. The disable function is glitchless, and does not increase the clock latency to the primary clock network. Four additional DCC elements control the clock inputs from the CrossLink-NX domain logic to the Center MUX elements (DSC_CMUX). This DCC controls the clock sources from the Primary CLOCK MIDMUX before they are fed to the Primary Center MUXs that drive the domain clock network. For more information about the DCC, refer to CrossLink-NX sysCLOCK PLL/DLL Design and Usage Guide (FPGA-TN-02095). 2.3.10. DDRDLL CrossLink-NX has 2 identical DDRDLL blocks, located in the lower left and lower right corners of the device. Each DDRDLL (master DLL block) can generate a phase shift code representing the amount of delay in a delay block that corresponding to 90-degree phase of the reference clock input, and provide this code to every individual DQS block and DLLDEL slave delay element. The reference clock can be either from PLL, or input pin. This code is used in the DQSBUF block that controls a set of DQS pin groups to interface with DDR memory (slave DLL). The DQSBUF uses this code to controls the DQS input of the DDR memory to 90 degree shift to clock DQs at the center of the data eye for DDR memory interface.  The code is also sent to another slave DLL, DLLDEL, that takes a primary clock input and generates a 90 degree shift clock output to drive the clocking structure. This is useful to interface edge-aligned Generic DDR, where 90 degree clocking needs to be created. Not all primary clock inputs have associated DLLDEL control. Figure 2.11 shows DDRDLL connectivity to a DLLDEL block (connectivity to DQSBUF blocks is similar). © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 25 CrossLink-NX Family Preliminary Data Sheet To both BMID and ECLKINMUX + - DLLDEL Left DDRDLL code2 code1 PCLK Input 9 Right DDRDLL 9 Figure 2.11. DLLDEL Functional Diagram Each DDRDLL can generate delay code based on the reference clock frequency. The slave DLL (DQSBUF and DLLDEL) use the code to delay the signal, to create the phase shifted signal used for either DDR memory, or creating 90 degree shift clock. Figure 2.12 shows the DDRDLL and the slave DLLs on the top level view. Left DDRDLL Right DDRDLL Digital Delay Code (L) Digital Delay Code (R) Refclk Sel DLLDEL Refclk Sel DLLDEL BANK5 ECLK DQS0 DQS1 BANK4 ECLK DLLDEL DQS0 DQS1 BANK3 ECLK Figure 2.12. CrossLink-NX DDRDLL Architecture 2.4. SGMII Clock Data Recovery (CDR) The CrossLink-NX-40 Device includes two hardened Clock Data Recovery (CDR). The CDR’s enables Serial Gigabit Media Independent Interface (SGMII) solutions. There are three main blocks in each CDR, the CDR, deserializer and FIFO. Each CDR features two loops. The first loop is locked to the reference clock. Once locked, the loop switches to the data path loop where the CDR tracks the data signals to generate the correcting signals needed to achieve and maintain phase lock with the data. The data is then passed through a deserializer which deserialize the data to 10-bit parallel data. The 10-bit parallel data is then sent to the FIFO bridge which allows the CDR to interface with the rest of the FPGA. Figure 2.13 shows a block diagram of the SGMII CDR IP. The two hardened blocks are located at the bottom left of the chip and uses the high speed I/O Bank 5 for the differential pair input. It is recommended that the reference clock should be entered through a GPIO that has connection to the PLL on the lower left corner as well. For more information about how to implement the hardened CDR for your SGMII solution, refer to the CrossLink-NX High-Speed I/O Interface (FPGA-TN-02097). © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 26 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet SGMII CDR IP lmmi_dk lmmi_request lmmi_wrdn lmmi_offset[3:0] lmmi_rdata[7:0] lmmi_rdata_valid lmmi_ready lmmi_wdata[7:0] lmmi_reset ip_ready sgmii_cdr_icnst sgmii_in DUAL_LOOP CDR sgmii_rxd rxd rxd_des DESERIALIZER FIFO rclk_des dco_calib_rst dco_facq_rst rrst sgmii_pclk sgmii_refclk(125 MHz) sgmii_rclk Figure 2.13. SGMII CDR IP 2.5. sysMEM Memory CrossLink-NX devices contain a number of sysMEM Embedded Block RAM (EBR). The EBR consists of an 18 Kb RAM with memory core, dedicated input registers and output registers as well as optional pipeline registers at the outputs. Each EBR includes functionality to support true dual-port, pseudo dual-port, single-port RAM, ROM and built in FIFO. In CrossLink-NX, unused EBR blocks is powered down to minimize power consumption. 2.5.1. sysMEM Memory Block The sysMEM block can implement single port, dual port or pseudo dual port memories. Each block can be used in a variety of depths and widths as listed in Table 2.4. FIFO’s can be implemented using the built in read and write address counters and programmable full, almost full, empty and almost empty flags. The EBR block facilitates parity checking by supporting an optional parity bit for each data byte. EBR blocks provide byte-enable support for configurations with 18bit and 36-bit data widths. For more information, refer to CrossLink-NX Memory Usage Guide (FPGA-TN-02094). EBR also provides a build in ECC engine. The ECC engine supports a write data width of 32 bits and it can be cascaded for larger data widths such as x64. The ECC parity generator creates and stores parity data for each 32-bit word written. When a read operation is performed, it compares the data with its associated parity data and report back if any Single Event Upset (SEU) event has disturbed the data. Any single bit data disturb is automatically corrected at the data output. In addition, two dedicated error flags indicate if a single-bit or two-bit error has occurred. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 27 CrossLink-NX Family Preliminary Data Sheet Table 2.4. sysMEM Block Configurations Memory Mode Single Port True Dual Port Pseudo Dual Port Configurations 16,384 x 1 8,192 x 2 4,096 x 4 2,048 x 9 1,024 x 18 512 x 36 16,384 x 1 8,192 x 2 4,096 x 4 2,048 x 9 1,024 x 18 16,384 x 1 8,192 x 2 4,096 x 4 2,048 x 9 1,024 x 18 512 x 36 2.5.2. Bus Size Matching All of the multi-port memory modes support different widths on each of the ports (except ECC mode which only supports a write data width of 32 bits). The RAM bits are mapped LSB word 0 to MSB word 0, LSB word 1 to MSB word 1, and so on. Although the word size and number of words for each port varies, this mapping scheme applies to each port. 2.5.3. RAM Initialization and ROM Operation If desired, the contents of the RAM can be pre-loaded during device configuration. By preloading the RAM block during the chip configuration cycle and disabling the write controls, the sysMEM block can also be utilized as a ROM. 2.5.4. Memory Cascading Larger and deeper blocks of RAM can be created using EBR sysMEM Blocks. Typically, the Lattice design tools cascade memory transparently, based on specific design inputs. 2.5.5. Single, Dual and Pseudo-Dual Port Modes In all the sysMEM RAM modes, the input data and address for the ports are registered at the input of the memory array. The output data of the memory is optionally registered at the output. 2.5.6. Memory Output Reset The EBR utilizes latches at the A and B output ports. These latches can be reset asynchronously or synchronously. RSTA and RSTB are local signals, which reset the output latches associated with Port A and Port B, respectively. The Global Reset (GSRN) signal can reset both ports. The output data latches and associated resets for both ports are as shown in Figure 2.14. The optional Pipeline Registers at the outputs of both ports are also reset in the same way. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 28 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Memory Core D SET Q Port A[17:0] LCLR Output Data Latches D SET Q Port B[17:0] LCLR RSTA RSTB GSRN Programmable Disable Figure 2.14. Memory Core Reset For further information on the sysMEM EBR block, see the list of technical documentation in Supplemental Information section. 2.6. Large RAM The CrossLink-NX device includes additional memory resources in the form of Large Random-Access Memory (LRAM) blocks. The LRAM is designed to work as Single-Port RAM, Dual-Port RAM, Pseudo Dual-Port RAM, and ROM memories. It is meant to function as additional memory resources for you beyond what is available in the EBR and PFU. Each individual Large RAM block contains 0.5 Mbit of memory, and has a programmable data width of up to 32 bits. Cascading Large RAM blocks allows data widths of up to 64 bits. Additionally, there is the ability to use either Error Correction Coding (ECC) or byte enable. 2.7. sysDSP The CrossLink-NX family provides an enhanced sysDSP architecture, making it ideally suited for low-cost, highperformance Digital Signal Processing (DSP) applications. Typical functions used in these applications are Finite Impulse Response (FIR) filters, Fast Fourier Transforms (FFT) functions, Correlators, Reed-Solomon/Turbo/Convolution encoders and decoders. These complex signal processing functions use similar building blocks such as multiply-adders and multiply-accumulators. 2.7.1. sysDSP Approach Compared to General DSP Conventional general-purpose DSP chips typically contain one to four (Multiply and Accumulate) MAC units with fixed data-width multipliers; this leads to limited parallelism and limited throughput. Their throughput is increased by higher clock speeds. In the CrossLink-NX device family, there are many DSP blocks that can be used to support different data widths. This allows you to use highly parallel implementations of DSP functions. You can optimize DSP performance versus area by choosing appropriate levels of parallelism. Figure 2.15 compares the fully serial implementation to the mixed parallel and serial implementation. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 29 CrossLink-NX Family Preliminary Data Sheet Operand A Operand A Operand B Operand A Operand B Operand B Operand B X Single Multiplier Operand A X M loops Multiplier 0 X m/k loops X Multiplier 1 Multiplier k Accumulator (k adds) Function Implemented in General Purpose DSP + m/k accumulate Output Function Implemented in CrossLink-NX Figure 2.15. Comparison of General DSP and CrossLink-NX Approaches 2.7.2. sysDSP Architecture Features The CrossLink-NX sysDSP Slice has been significantly enhanced to provide functions needed for advanced processing applications. These enhancements provide improved flexibility and resource utilization. The CrossLink-NX sysDSP Slice supports many functions that include the following:  Symmetry support. The primary target application is wireless. 1D Symmetry is useful for many applications that use FIR filters when their coefficients have symmetry or asymmetry characteristics. The main motivation for using 1D symmetry is cost/size optimization. The expected size reduction is up to 2x.  Odd Mode – Filter with Odd number of taps  Even Mode – Filter with Even number of taps  Two dimensional (2D) Symmetry Mode – Supports 2D filters for mainly video applications  Dual-multiplier architecture. Lower accumulator overhead to half and the latency to half compared to single multiplier architecture.  Fully cascadable DSP across slices. Support for symmetric, asymmetric and non-symmetric filters.  Multiply (36 x 36, two 18 x 36, four 18 x 18 or eight 9 x 9)  Multiply Accumulate (supports one 18 x 36 multiplier result accumulation, two 18 x 18 multiplier result accumulation or four 9 x 9 multiplier result accumulation)  Two Multiplies feeding one Accumulate per cycle for increased processing with lower latency (two 18 x 18 Multiplies feed into an accumulator that can accumulate up to 54 bits)  Pipeline registers  1D Symmetry support. The coefficients of FIR filters have symmetry or negative symmetry characteristics.  Odd Mode – Filter with Odd number of taps  Even Mode – Filter with Even number of taps  2D Symmetry support. The coefficients of 2D FIR filters have symmetry or negative symmetry characteristics.  3*3 and 3*5 – Internal DSP Slice support  5*5 and larger size 2D blocks – Semi internal DSP Slice support © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 30 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet     Flexible saturation and rounding options to satisfy a diverse set of applications situations Flexible cascading DSP blocks  Minimizes fabric use for common DSP functions  Enables implementation of FIR Filter or similar structures using dedicated sysDSP slice resources only  Provides matching pipeline registers  Can be configured to continue cascading from one row of sysDSP slices to another for longer cascade chains RTL Synthesis friendly synchronous reset on all registers, while still supporting asynchronous reset for legacy users Dynamic MUX selection to allow Time Division Multiplexing (TDM) of resources for applications that require processor-like flexibility that enables different functions for each clock cycle For most cases, as shown in Figure 2.16, the CrossLink-NX sysDSP is backwards-compatible with the LatticeECP3™ sysDSP block, such that, legacy applications can be targeted to CrossLink-NX sysDSP. Figure 2.16 shows the diagram of sysDSP. Input B1 Input C Input B2 9+9 Input A1 REG Input A2 Input B1 Input C Input B2 9+9 Input A1 9x9 Input C Input B2 9+9 REG Input A2 Input B1 Input A1 REG Input A2 9x9 Input C Input B2 9+9 Input A1 REG Input A2 9x9 18 X 18 Input B1 9x9 18 X 18 Input B1 Input C Input B2 9+9 Input A1 REG Input A2 Input B1 Input C Input B2 9+9 Input A1 REG Input A2 9x9 Input B1 Input C Input A1 REG Input A2 9x9 Input C 9+9 Input B2 9+9 Input A1 REG Input A2 9x9 18 X 18 18 X 36 (CSA) Input B2 Input B1 9x9 18 X 18 18 X 36 (CSA) 36 X 36 (CSA) REG 18 REG 18 REG 18 REG 18 REG 18 REG 18 REG 18 ACC54 ACC54 Output Register Output Register REG 18 Note : All Registers inside the DSP Block are Bypassable via Configuration Setting Figure 2.16. CrossLink-NX DSP Functional Block Diagram The CrossLink-NX sysDSP block supports the following basic elements.  MULT (Multiply)  MAC (Multiply, Accumulate)  MULTADDSUB (Multiply, Addition/Subtraction)  MULTADDSUBSUM (Multiply, Addition/Subtraction, Summation) © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 31 CrossLink-NX Family Preliminary Data Sheet Table 2.5 shows the capabilities of CrossLink-NX sysDSP block versus the above functions. Table 2.5. Maximum Number of Elements in a sysDSP block Width of Multiply MULT MAC MULTADDSUB MULTADDSUBSUM x9 8 2 2 2 x18 4 2 2 2 x36 1 — — — Some options are available in the four elements. The input register in all the elements can be directly loaded or can be loaded as a shift register from previous operand registers. By selecting dynamic operation, the following operations are possible:  In the Add/Sub option, the Accumulator can be switched between addition and subtraction on every cycle.  The loading of operands can switch between parallel and serial operations. For further information, refer to CrossLink-NX sysDSP Usage Guide (FPGA-TN-02096). 2.8. Programmable I/O (PIO) The programmable logic associated with an I/O is called a PIO. The individual PIO are connected to their respective sysI/O buffers and pads. On the CrossLink-NX devices, the Programmable I/O cells (PIC) are assembled into groups of two PIO cells called a Programmable I/O Cell or PIC. The PICs are placed on all four sides of the device. On all the CrossLink-NX devices, two adjacent PIO can be combined to provide a complementary output driver pair. 2.9. Programmable I/O Cell (PIC) CrossLink-NX is consists of base PIC and gearing PIC, base PIC covers top, left right bank, gearing PIC covers bottom banks only that supports DDR operation. gearing PIC contains the edge monitor to center to locate the center of data window. The PIC contains three blocks: an input register block, output register block, and tristate register block. These blocks contain registers for operating in a variety of modes along with the necessary clock and selection logic. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 32 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 1 PIC PIO A Input Register Block Output and Tristate Register Block Core Logic/ Routing Pin A Input and Output Gearbox PIO B Input Register Block Output and Tristate Register Block Pin B Figure 2.17. Group of Two High Performance Programmable I/O Cells 1 PIC PIO A Input Register Block Output and Tristate Register Block Pin A Core Logic/ Routing PIO B Input Register Block Output and Tristate Register Block Pin B Figure 2.18. Wide Range Programmable I/O Cells © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 33 CrossLink-NX Family Preliminary Data Sheet 2.9.1. Input Register Block The input register blocks for the PIO on all edges contain delay elements and registers that can be used to condition high-speed interface signals before they are passed to the device core. In addition, the input register blocks for the PIO on the bottom edges include built-in FIFO logic to interface to DDR and LPDDR memory. The Input register block on the bottom side includes gearing logic and registers to implement IDDRX1, IDDRX2, IDDRX4, IDDRX5 gearing functions. With two PICs sharing the DDR register path, it can also implement IDDRX71 function used for 7:1 LVDS interfaces. It uses three sets of registers – shift, update, and transfer to implement gearing and the clock domain transfer. The first stage registers samples the high-speed input data by the high-speed edge clock on its rising and falling edges. The second stage registers perform data alignment based on the control signals. The third stage pipeline registers pass the data to the device core synchronized to the low-speed system clock. For more information on gearing function, refer to CrossLink-NX High-Speed I/O Interface (FPGA-TN-02097). 2.9.2.1. Input FIFO The CrossLink-NX PIO has dedicated input FIFO per single-ended pin for input data register for DDR Memory interfaces. The FIFO resides before the gearing logic. It transfers data from DQS domain to continuous ECLK domain. On the Write side of the FIFO, it is clocked by DQS clock, which is the delayed version of the DQS Strobe signal from DDR memory. On the Read side of FIFO, it is clocked by ECLK. ECLK may be any high-speed clock with identical frequency as DQS (the frequency of the memory chip). Each DQS group has one FIFO control block. It distributes FIFO read/write pointer to every PIC in same DQS group. DQS Grouping and DQS Control Block is described in DDR Memory Support section. Table 2.6. Input Block Port Description Name D Q[1:0]/Q[3:0]/Q[6:0]/Q[7:0]/Q[9:0] RST SCLK ECLK DQS ALIGNWD Type Input Output Input Input Input Input Input Description High Speed Data Input Low Speed Data to the device core Reset to the Output Block Slow Speed System Clock High Speed Edge Clock Clock from DQS control Block used to clock DDR memory data Data Alignment signal from device core. Figure 2.19 shows the input register block for the PIO on the top, left, and right edges. D INCK INFF Programmable Delay Cell Q INFF SCLK RST IDDRX1 Q[1:0] Figure 2.19. Input Register Block for PIO on Top, Left, and Right Sides of the Device © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 34 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Figure 2.20 shows the input register block for the PIO located on the bottom edge. IN CK IN FF Programmable D Delay Cell IN FF Q Generic IDDRX1 IDDRX2 FIFO IDDRX4 Delayed DQS ECLK Q[1:0]/ IDDRX5 Q[3:0]/ Q[6:0]*/ IDDRX71* Q[7:0]/ Q[9:0] ECLK Memory IDDRX2 SCLK RST ALIGNWD *For 7:1 LVDS interface only. It is required to use PIO pair pins (PIOA/B or PIOC/D). Figure 2.20. Input Register Block for PIO on Bottom Side of the Device 2.9.2. Output Register Block The output register block registers signal from the core of the device before they are passed to the sysI/O buffers. CrossLink-NX output data path has output programmable flip flops and output gearing logic. On the bottom side, the output register block can support 1x, 2x, x4, x5, and 7:1 gearing enabling high speed DDR interfaces and DDR memory interfaces. On the top, left, and right sides, the banks support 1x gearing. CrossLink-NX output data path diagram is shown in Figure 2.21. The programmable delay cells are also available in the output data path. For detailed description of the output register block modes and usage, you can refer to CrossLink-NX High-Speed I/O Interface (FPGA-TN-02097). Programmable Delay Cell D OUTFF RST SCLK D[1:0] Q Generic ODDRX1 Figure 2.21. Output Register Block on Top, Left, and Right Sides © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 35 CrossLink-NX Family Preliminary Data Sheet Programmable Delay Cell D Q OUTFF RST Generic ODDRX1/ ODDRX2/ ODDRX4 ODDRX5 ODDR71* SCLK ECLK DQSW DQSW270 Memory Q[1:0]/ ODDRX2 OSHX2 Q[3:0]/ Q[6:0]*/ Q[7:0]/ Q[9:0] *For 7:1 LVDS interface only. It is required to use PIO pair pins PIOA/B. Figure 2.22. Output Register Block on Bottom Side Table 2.7. Output Block Port Description Name Type Description Q Output D Input High Speed Data Output Data from core to output SDR register Q[1:0]/Q[3:0]/Q[6:0]/Q[7:0]/Q[9:0] Input Low Speed Data from device core to output DDR register RST Input Reset to the Output Block SCLK Input Slow Speed System Clock ECLK Input High Speed Edge Clock DQSW Input Clock from DQS control Block used to generate DDR memory DQS output DQSW270 Input Clock from DQS control Block used to generate DDR memory DQ output 2.10. Tristate Register Block The tristate register block registers tristate control signals from the core of the device before they are passed to the sysI/O buffers. The block contains a register for SDR operation. In SDR, TD input feeds one of the flip-flops that then feeds the output. In DDR, operation used mainly for DDR memory interface can be implemented on the bottom side of the device. Here, two inputs feed the tristate registers clocked by both ECLK and SCLK. Figure 2.23 and Figure 2.24 show the Tristate Register Block functions on the device. For detailed description of the tristate register block modes and usage, you can refer to CrossLink-NX High-Speed I/O Interface (FPGA-TN-02097). TQ TD RST SCLK TSFF Figure 2.23. Tristate Register Block on Top, Left, and Right Sides © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 36 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet TQ TD TSFF RST SCLK ECLK THSX2 DQSW DQSW270 T[1:0] Figure 2.24. Tristate Register Block on Bottom Side Table 2.8. Tristate Block Port Description Name Type Description TD Input Tristate Input to Tristate SDR Register RST Input Reset to the Tristate Block TD[1:0] Input Tristate input to TSHX2 function SCLK Input Slow Speed System Clock ECLK Input High Speed Edge Clock DQSW Input Clock from DQS control Block used to generate DDR memory DQS output Input Clock from DQS control Block used to generate DDR memory DQ output DQSW270 TQ Output Output of the Tristate block 2.11. DDR Memory Support 2.11.1. DQS Grouping for DDR Memory Certain PICs have additional circuitry to allow the implementation of high-speed source synchronous and DDR3/DDR3L, LPDDR2 or LPDDR3 memory interfaces. The support varies by the edge of the device as detailed below. The Bottom side of the PIC have fully functional elements supporting DDR3/DDR3L, LPDDR2, or LPDDR3 memory interfaces. Every 16 PIO on the bottom side are grouped into one DQS group, as shown in Figure 2.25. Within each DQS group, there are two pre-placed pins for DQS and DQS# signals. The rest of the pins in the DQS group can be used as DQ signals and DM signal. The number of pins in each DQS group bonded out is package dependent. DQS groups with less than 11 pins bonded out can only be used for LPDDR2/3 Command/ Address busses. In DQS groups with more than 11 pins bonded out, up to two pre-defined pins are assigned to be used as virtual VCCIO, by driving these pins to HIGH, and connecting these pins to VCCIO power supply. These connections create soft connections to VCCIO thru these output pins, and make better connections on VCCIO to help to reduce SSO noise. For details, refer to CrossLink-NX HighSpeed I/O Interface (FPGA-TN-02097). © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 37 CrossLink-NX Family Preliminary Data Sheet DQS Pad A (T) Pad A sysIO Buffer sysIO Buffer Pad B PIO A PIO A sysIO Buffer Pad A (T) Pad B (C) PIO B sysIO Buffer Pad B (C) sysIO Buffer PIO A sysIO Buffer PIO B PIO B Pad A (T) Pad A sysIO Buffer Pad B (C) sysIO Buffer sysIO Buffer Pad A PIO A PIO A sysIO Buffer Pad B Pad B PIO B sysIO Buffer Pad A (T) sysIO Buffer PIO A sysIO Buffer Pad B (C) PIO B PIO B sysIO Buffer Pad A Delay PIO B sysIO Buffer Pad B DQSBUF PIO A sysIO Buffer PIO A PIO B Figure 2.25. DQS Grouping on the Bottom Edge 2.11.2. DLL Calibrated DQS Delay and Control Block (DQSBUF) To support DDR memory interfaces (DDR3/DDR3L, LPDDR2/3), the DQS strobe signal from the memory must be used to capture the data (DQ) in the PIC registers during memory reads. This signal is output from the DDR memory device aligned to data transitions and must be time shifted before it can be used to capture data in the PIC. This time shifted is achieved by using DQSBUF programmable delay line in the DQS Delay Block (DQS read circuit). The DQSBUFL is implemented as a slave delay line and works in conjunction with a master DDRDLL. This block also includes slave delay line to generate delayed clocks used in the write side to generate DQ and DQS with correct phases within one DQS group. There is a third delay line inside this block used to provide write leveling feature for DDR write if needed. Each of the read and write side delays can be dynamically shifted using margin control signals that can be controlled by the core logic. FIFO Control Block include here generates the Read and Write Pointers for the FIFO block inside the Input Register Block. These pointers are generated to control the DQS to ECLK domain crossing using the FIFO module. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 38 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet BURST_DET DQS Preamble/Postamble Management READ[1:0] READ_CLK_SEL[2:0] FIFO Control and Data Valid Generation SCLK ECLK WRPNTR[2:0] RDPNTR[2:0] DATAVALID Slave Delay Line (RD) with Adjustment/Margin Test RD_CODN, RD_DIRECTION, RD_MOVE DQSR90 Rd_cout WR_COUT WRITE_LEVELING_LOADN WRITE_LEVELING_DIRECTION WRITE_LEVELING_MOVE Slave Delay (WR) with Adjustment/Margin Test and Write Leveling DQSW270 DQSW WR_LOADN, WR_DIRECTION, WR_MOVE DELAY CODE[8:0] RST DONE_GWE GSR DELAY CODE[8:0] Figure 2.26. DQS Control and Delay Block (DQSBUF) Table 2.9. DQSBUF Port List Description Name Type Description DQS Input DDR memory DQS strobe READ[1:0] Input Read Input from DDR Controller READCLKSEL[2:0] Input Read pulse selection SCLK Input Slow System Clock ECLK Input High Speed Edge Clock (same frequency as DDR memory) RDLOADN, RDMOVE, RDDIRECTION Input Dynamic Margin Control ports for Read delay WRLOADN, WRMOVE, WRDIRECTION Input Dynamic Margin Control ports for Write delay DELAYCODE_I[8:0] Input Dynamic Delay Control WRITE_LEVELING_LOADN, WRITE_LEVELING_DIRECTION, WRITE_LEVELING_MOVE Input Write Leveling Control DQSR90 Output 90 delay DQS used for Read DQSW270 Output 90 delay clock used for DQ Write DQSW Output Clock used for DQS Write RDPNTR[2:0] Output Read Pointer for IFIFO module WRPNTR[2:0] Output Write Pointer for IFIFO module DATAVALID Output Signal indicating start of valid data BURSTDET Output Burst Detect indicator RD_COUT Output Read Count WR_COUT Output Write Count DELAYCODE_O[8:0] Output Dynamic Delay Control © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 39 CrossLink-NX Family Preliminary Data Sheet 2.12. sysI/O Buffer Each I/O is associated with a flexible buffer referred to as a sysI/O buffer. These buffers are arranged around the periphery of the device in groups referred to as banks. The sysI/O buffers allows you to implement the wide variety of standards that are found in today’s systems including LVDS, HSUL, SSTL Class I and II, LVCMOS, LVTTL, and MIPI. The CrossLink-NX family contains multiple Programmable I/O Cell (PIC) blocks. Each PIC contains two Programmable I/O, PIOA and PIOB. Each PIO includes a sysI/O buffer and I/O logic. Two adjacent PIO can be joined to provide a differential I/O pair. These two pairs are referred to as True and Comp, where True Pad is associated with the positive side of the differential I/O, and the complement with the negative. The top, left and right side banks support I/O standards from 3.3 V to 1.0 V while the bottom supports I/O standards from 1.8 V to 1.0 V. Every pair of I/O on the bottom bank also have a true LVDS and SLVS Tx Driver. In addition, the bottom bank supports single-ended input termination. Both static and dynamic termination are supported. Dynamic termination is used to support the DDR/LPDDR interface standards. For more information about DDR implementation in I/O Logic and DDR memory interface support, refer to CrossLink-NX High-Speed I/O Interface (FPGA-TN-02097). 2.12.1. Supported sysI/O Standards CrossLink-NX sysI/O buffer supports both single-ended differential and differential standards. Single-ended standards can be further subdivided into internally ratioed standards such as LVCMOS, LVTTL, and externally referenced standards such as HSUL and SSTL. The buffers support the LVTTL, LVCMOS 1.0 V, 1.2 V, 1.5 V, 1.8 V, 2.5 V, and 3.3 V standards. Differential standards supported include LVDS, SLVS, differential LVCMOS, differential SSTL, and differential HSUL. For better support of video standards, subLVDS and MIPI_D-PHY are also supported. Table 2.10 and Table 2.11 provide a list of sysI/O standards supported in CrossLink-NX devices. Table 2.10. Single-Ended I/O Standards Standard LVTTL33 LVCMOS33 LVCMOS25 LVCMOS18 LVCMOS15 LVCMOS12 LVCMOS10 HTSL15 I SSTL 15 I SSTL 135 I HSUL12 LVCMOS18H LVCMOS15H LVCMOS12H LVCMOS10H LVCMOS10R *Note: Output supported by LVCMOS10H. Input Yes Yes Output Yes Yes Bi-directional Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes — Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes* © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 40 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Table 2.11. Differential I/O Standards Standard LVDS SUBLVDS Input Yes Yes Output Yes No Bi-directional Yes — SLVS SUBLVDSE SUBLVDSEH LVDSE MIPI_D-PHY HSTL15D_I SSTL15D_I SSTL15D_II SSTL135D_I SSTL135D_II HSUL12D LVTTL33D LVCMOS33D LVCMOS25D Yes — — — Yes Yes Yes Yes Yes Yes Yes — — — Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes — — — — Yes Yes Yes Yes Yes Yes Yes — — — 2.12.2. sysI/O Banking Scheme CrossLink-NX devices have up to eight banks in total. For 40K device, there are one bank on top, two banks each at left and right side of device, and three on the bottom side of device. For 17K device, one bank on top, one on right side and three on the bottom side of device. The higher density CrossLink-NX device has more pins in each bank. Bank 0, Bank 1, Bank 2, Bank 6, and Bank 7 support up to VCCIO 3.3 V while Bank 3, Bank 4, and Bank 5 support up to VCCIO 1.8 V. In addition, Bank 3, Bank 4, and Bank 5 support two VREF inputs for flexibility to receive two different referenced input levels on the same bank. Figure 2.27 shows the location of each bank. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 41 CrossLink-NX Family Preliminary Data Sheet VCCIO(0) GND Bank 0 GND VCCIO(7) GND Bank 7* Bank 1 Bank 6* Bank 2* GND VCCIO(6) VCCIO(1) GND Bank 4 Bank 5 GND GND VCCIO(2) Bank 3 GND VREF2(3) VREF1(3) VCCIO(3) VREF2(4) VREF1(4) VCCIO(4) VREF2(5) VREF1(5) VCCIO(5) *Note: Bank not available in LIFCL-17. Figure 2.27. sysI/O Banking 2.12.2.1. Typical sysI/O I/O Behavior During Power-up The internal Power-On-Reset (POR) signal is deactivated when VCC and VCCAUX have reached satisfactory levels. After the POR signal is deactivated, the FPGA core logic becomes active. It is your responsibility to ensure that all other VCCIO banks are active with valid input logic levels to properly control the output logic states of all the I/O banks that are critical to the application. For more information about controlling the output logic state with valid input logic levels during power-up in CrossLink-NX devices, see the list of technical documentation in Supplemental Information section. The VCC and VCCAUX supply the power to the FPGA core fabric, whereas the VCCIO supplies power to the I/O buffers. In order to simplify the system design while providing consistent and predictable I/O behavior, it is recommended that the I/O buffers be powered-up prior to the FPGA core fabric. For different power supply voltage level by the I/O banks, please refer to CrossLink-NX sysI/O Usage Guide (FPGA-TN-02067) for detailed information. 2.12.2.2. VREF1 and VREF2 Bank 3, Bank 4, and Bank 5 can support two separate VREF input voltage, VREF1, and VREF2. To assign a VREF driver, use IO_Type = VREF1_DRIVER or VREF2_DRIVER. To assign VREF to a buffer, use VREF1_LOAD or VREF2_LOAD. 2.12.2.3. SysI/O Standards Supported by I/O Bank All banks can support multiple I/O standards under the VCCIO rules discussed above. Table 2.12 and Table 2.13 summarize the I/O standards supported on various sides of the CrossLink-NX device. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 42 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Table 2.12. Single-Ended I/O Standards Supported on Various Sides Standard LVTTL33 LVCMOS33 Top Yes Yes LVCMOS25 Yes LVCMOS18 Yes LVCMOS15 Yes LVCMOS12 Yes LVCMOS10 Yes LVCMOS18H — LVCMOS15H — LVCMOS12H — LVCMOS10H — LVCMOS10R — HTSL15 I — SSTL 15 I, II — SSTL 135 I, II — HSUL12 — *Note: Left bank is not available in LIFCL-17. Left* Yes Yes Right Yes Yes Bottom — — Yes Yes Yes Yes Yes — — — — — — — — — Yes Yes Yes Yes Yes — — — — — — — — — — — — — — Yes Yes Yes Yes Yes Yes Yes Yes Yes Left* — — — Right — — — Bottom Yes Yes Yes Yes — Yes — — — — — — — Yes Yes Yes Yes — Yes — — — — — — — Yes Yes Yes — Yes — Yes Yes Yes Yes Yes Yes Yes — — — Table 2.13. Differential I/O Standards Supported on Various Sides Standard LVDS SUBLVDS SLVS Top — — — SUBLVDSE Yes SUBLVDSEH — LVDSE Yes MIPI_D-PHY — HSTL15D_I — SSTL15D_I — SSTL15D_II — SSTL135D_I — SSTL135D_II — HSUL12D — LVTTL33D Yes LVCMOS33D Yes LVCMOS25D Yes *Note: Left bank is not available in LIFCL-17. 2.12.2.4. Hot Socketing CrossLink-NX devices have been carefully designed to ensure predictable behavior during power-up and power-down. During power-up and power-down sequences, the I/O remain in tristate until the power supply voltage is high enough to ensure reliable operation. In addition, leakage into I/O pins is controlled within specified limits. Bank 0, Bank 1, Bank 2, Bank 6, and Bank 7 are fully hot socket able while Bank 3, Bank 4, and Bank 5 are not supported. 2.12.3. sysI/O Buffer Configurations This section describes the various sysI/O features available on the CrossLink-NX device. Refer to CrossLink-NX sysI/O Usage Guide (FPGA-TN-02067) for detailed information. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 43 CrossLink-NX Family Preliminary Data Sheet 2.13. Analog Interface The CrossLink-NX family provides an analog interface, consisting of two Analog to Digital Convertors (ADC), three continuous time comparators and an internal junction temperature monitoring diode. The two ADCs can sample the input sequentially or simultaneously. 2.13.1. Analog to Digital Converters The Analog to Digital Convertor is a 12-bit, 1 MSPS SAR (Successive Approximation Resistor/capacitor) architecture converter. The ADC supports both continuous and single shot conversion modes. The ADC input is selected among pre-selected GPIO input pairs, dedicated analog input pair, the internal junction temperature sensing diode and internal voltage rails. The input signal can be converted in either uni-polar or bi-polar mode. The reference voltage is selectable between the 1.2 V internal reference generator and an external reference. The ADC can convert up to a 1.8 V input signal with a 1.8 V external reference voltage. The ADC has an auto-calibration function which calibrates the gain and offset. 2.13.2. Continuous Time Comparators The continuous-time comparator can be used to compare a pre-selected GPIO’s input pairs or one dedicated comparator input pair. The output of the comparator is provided as continuous and latched data. 2.13.3. Internal Junction Temperature Monitoring Diode On-die junction temperature can be monitored using the internal junction temperature monitoring diode. The PTAT (proportional to absolute temperature) diode voltage can be monitored by the ADC to provide a digital temperature readout. Refer to CrossLink-NX ADC Usage Guide (FPGA-TN-02129) for more details. 2.14. IEEE 1149.1-Compliant Boundary Scan Testability All CrossLink-NX devices have boundary scan cells that are accessed through an IEEE 1149.1 compliant Test Access Port (TAP). This allows functional testing of the circuit board on which the device is mounted through a serial scan path that can access all critical logic nodes. Internal registers are linked internally, allowing test data to be shifted in and loaded directly onto test nodes, or test data to be captured and shifted out for verification. The test access port consists of dedicated I/O: TDI, TDO, TCK, and TMS. The test access port uses VCCIO1 for power supply. The test access port is supported for VCCIO1 = 1.8 V - 3.3 V. For more information, refer to CrossLink-NX sysCONFIG Usage Guide (FPGA-TN-02099). 2.15. Device Configuration All CrossLink-NX devices contain two ports that can be used for device configuration. The Test Access Port (TAP), which supports bit-wide configuration, and the sysCONFIG port, support serial, quad, and byte configuration. The TAP supports both the IEEE Standard 1149.1 Boundary Scan specification and the IEEE Standard 1532 In-System Configuration specification. The JTAG_EN is the only dedicated pin supported by sysCONFIG. PPROGRAMN/INITN/DONE are enabled by default, but can be turned into GPIO. The remaining sysCONFIG pins are used as dual function pins. Refer to CrossLink-NX sysCONFIG Usage Guide (FPGA-TN-02099) for more information about using the dual-use pins as general purpose I/O. There are various ways to configure a CrossLink-NX device:  JTAG  Standard Serial Peripheral Interface (SPI) – Interface to boot PROM Support x1, x2, x4 wide SPI memory interfaces. (Master SPI mode)  Inter-Integrated Circuit Bus (I2C)  Improved Inter-Integrated Circuit Bus (I3C)  System microprocessor to drive a serial slave SPI port (SSPI mode) © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 44 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet   Lattice Memory Mapped Interface (LMMI), refer to CrossLink-NX sysI/O Usage Guide (FPGA-TN-02067) for condition. JTAG, SSPI, MSPI, I2C, and I3C are supported for VCCIO = 1.8 V - 3.3 V On power-up, based on the voltage level (high or low) of the PROGRAMN pin the FPGA SRAM is configured by the appropriate sysCONFIG port. If PROGRAMN pin is low, the FPGA is in the Slave configuration ports (Slave SPI, Slave I2C or Slave I3C) and is waiting for the correct Slave Configuration port activation key. PROGRAMN pin must be driven high within 400 ns of the end of transmission of the Slave Configuration port activation key, that is, the de-assertion of SCSN. If no slave port is declared active before the PROGRAMN pin is sensed HIGH, the FPGA is in Master SPI booting sequence (mode). In Master SPI booting mode, the FPGA boots from an external SPI boot PROM. Once a configuration port is activated, it remains active throughout that configuration cycle. The IEEE 1149.1 port can be activated any time after power-up by enabling the JTAG_EN pin and sending the appropriate command through the TAP port. 2.15.1. Enhanced Configuration Options CrossLink-NX devices have enhanced configuration features such as:  Early I/O release  Bitstream Decryption  Decompression Support  Watchdog Timer support  Dual and Multi-boot image support Early I/O Release is a new configuration feature in which certain I/O banks are released earlier so that customer systems have minimal disruption. For more details, refer to CrossLink-NX sysCONFIG Usage Guide (FPGA-TN-02099). Note that for Engineer Sample silicon (ES suffix), an Early I/O Release enabled bitstream is not compatible with direct SRAM programming (aka Fast Programming in Radiant Programmer). If attempted, the configuration operation fails and the part must be power-cycled before it can accept a non-Early I/O Release enabled bitstream. Watchdog Timer is a new configuration feature that helps you add a programmable timer option for timeout applications. 2.15.2.1. Dual-Boot and Multi-Boot Image Support Dual-boot and multi-boot images are supported for applications requiring reliable remote updates of configuration data for the system FPGA. After the system is running with a basic configuration, a new boot image can be downloaded remotely and stored in a separate location in the configuration storage device. Any time after the update the CrossLinkNX devices can be re-booted from this new configuration file. If there is a problem, such as corrupt data during download or incorrect version number with this new boot image, the CrossLink-NX device can revert back to the original backup golden configuration and try again. This all can be done without power cycling the system. For more information, refer to CrossLink-NX sysCONFIG Usage Guide (FPGA-TN-02099). © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 45 CrossLink-NX Family Preliminary Data Sheet 2.16. Single Event Upset (SEU) Support CrossLink-NX devices are unique due to the underlying technology used to build these devices is much more robust and less prone to soft errors. CrossLink-NX devices have an improved hardware implemented Soft Error Detection (SED) circuit which can be used to detect SRAM errors and allow them to be corrected. There are two layers of SED implemented in CrossLink-NX making it more robust and reliable. The SED hardware in CrossLink-NX devices is part of the Configuration block. The SED module in CrossLink-NX is an enhanced version as compared to the SED modules implemented in other Lattice devices. The configuration data is divided into frames so that the entire FPGA can be programmed precisely with ease. The SED hardware reads data from the FPGAs configuration memory and performs Error Correcting Code (ECC) calculation on every frame of configuration data (see Figure 2.1). Once a single bit of error is detected, Soft Error Upset (SEU), a notification is generated and SED resumes operation. For single bit errors, the corrected value is rewritten to the particular frame using ECC information. If more than one-bit error is detected within one frame of configuration data, an error message is generated. CrossLink-NX devices also have a dedicated logic to perform Cycle Redundancy Code (CRC) checks. This CRC runs in parallel for the entire bitstream along with ECC. After the ECC is calculated on all frames of configuration data, Cyclic Redundancy Check (CRC) is calculated for the entire configuration data (bitstream). The data that is read, and the ECC and CRC calculated, do not include EBR Big SRAM and distributed RAM memory. For further information on SED support, refer to CrossLink-NX Soft Error Detection (SED)/Correction (SEC) Usage Guide (FPGA-TN-02076). 2.17. On-Chip Oscillator The CrossLink-NX device features two different frequency Oscillators. One is tailored for low-power operation that runs at low frequency (LFOSC). Both Oscillators are controlled with internally generated current. The LFOSC runs at nominal frequency of 128 kHz. The high frequency oscillator (HFOSC) runs at a nominal frequency of 450 MHz, divisible to 2 MHz to 256 MHz by user option. The LFOSC always run, thus can be used to perform all alwayson functions with the lowest power possible. 2.18. User I²C IP The CrossLink-NX device has one I²C IP core. The core can be configured either as an I²C master or as an I²C slave. The pins for the I²C interface are pre-assigned. The core has the option to delay the either the input or the output, or both, by 50 ns nominal, using dedicated on-chip delay elements. This provides an easier interface with any external I2C components. In addition, 50 ns glitch filters are available for both SDA and SCL. When the IP core is configured as master, it is able to control other devices on the I2C bus through the pre-assigned pin interface. When the core is configured as the slave, the device is able to provide, for example, I/O expansion to an I²C Master. The I²C core supports the following functionality:  Master and Slave operation  7-bit and 10-bit addressing  Multi-master arbitration support  Clock stretching  Up to 1 MHz data transfer speed (Standard-Mode, Fast-Mode, Fast-Mode Plus)  General Call support  Optional receive and transmit data FIFOs with programmable sizes  Optionally 50 ns delay on input or output data, or both  Hard-Connection and Programmable I/O Connection Support  Programmable to a mode compliant with I3C requirements on legacy I2C Slave Devices.  Fast-Mode and Fast-Mode Plus Support © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 46 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet    Disabled Clock Stretching 50 ns SCL and SDA Glitch Filter Programmable 7-bit Address For further information on the User I²C, refer to CrossLink-NX I2C Hardened IP Usage Guide (FPGA-TN-02142). 2.19. Density Shifting The CrossLink-NX family is designed to ensure that different density devices in the same family and in the same package have the same pinout. Furthermore, the architecture ensures a high success rate when performing design migration from lower density devices to higher density devices. In many cases, it is also possible to shift a lower utilization design targeted for a high-density device to a lower density device. However, the exact details of the final resource utilization impact the likelihood of success in each case. An example is that some user I/O may become No Connects in smaller devices in the same package. Refer to the CrossLink-NX Pin Migration Tables and Lattice Radiant software for specific restrictions and limitations. 2.20. MIPI D-PHY Blocks The top side of the device includes two Hardened MIPI D-PHY quads. The Hardened D-PHY can be configured to support either Camera Serial Interface (CSI-2) or Display Serial Interface (DSI) applications as either transmitter or receiver. Below is a summary of the features supported by the Hardened D-PHY quads.  Transmit and receive compliant to MIPI Alliance’s MIPI D-PHY Specification version 1.2  High-Speed (HS) and Low-Power (LP) mode support (including built-in contention detection)  Supports continuous clock mode or low power (non-continuous) clock mode  Up to 10 Gbps per quad (2500 Mbps data rate per lane)  Supports up to 4 data lanes and one clock lane per Hardened D-PHY CrossLink-NX’s programmable I/O can also be configured as MIPI D-PHYs, referred to as Soft MIPI D-PHY. The Soft DPHY can be configured to support either Camera Serial Interface (CSI-2) or Display Serial Interface (DSI) applications as either transmitter or receiver. Below is a summary of the features supported by the Soft D-PHY.  Transmit and receive compliant to MIPI Alliance’s MIPI D-PHY Specification version 1.2  High-Speed (HS) and Low-Power (LP) mode support (including built-in contention detection)  Supports continuous clock mode or low power (non-continuous) clock mode  Up to 6 Gbps per port (1500 Mbps data rate per lane) in 121 csfBGA package  Up to 5 Gbps per port (1250 Mbps data rate per lane) in other packages  Supports up to 4 data lanes and one clock lane per port 2.21. Peripheral Component Interconnect Express (PCIe) The CrossLink-NX-40 Device features one lane of hardened PCIe block on the top side of the device. The PCIe block implements all three layers defined by the PCI Express Specification: Physical, Data Link, and Transaction as shown in Figure 2.28. Below is a summary of the features supported by the PCIe:  Gen 1 (2.5 Gb/s) and Gen 2 (5.0 Gb/s) speed  PCIe Express Base Specification 3.0 compliant including compliance with earlier PCI Express Specifications  Multi-function support with up to four physical functions  Endpoint support  Type 0 Configuration Registers in Endpoint Mode  Complete Error-Handling Support  32-bit Core Data Width  Many power management features including power budgeting © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 47 CrossLink-NX Family Preliminary Data Sheet PCI Express Core PHY RX PHY Interface (PIPE) PHY TX Tx PHY Layer Tx Data Link Layer Tx Trans Layer Rx PHY Layer Rx Data Link Layer Rx Trans Layer VC0_TX VC0_RX Power Management Error Reporting (AER) CLK, CONFIGURATION, AND MANAGEMENT LMMI CONFIGURATION REGISTERS Figure 2.28. PCIe Core The hardened PCIe block can be instantiated with the primitive PCIe through Lattice Radiant software however, it is not recommended to directly instantiate the PCIe primitive itself. It is highly recommended to generate the PCIe Endpoint Soft IP through IP Express instead. In Figure 2.29, the PCIe core is configured as Endpoint using the Soft logic and this Endpoint soft IP provides a wrapper around the PCIe primitive as well as providing useful functions such as bridging support for bus interfaces and DMA applications. In addition to the standard Transaction Layer Packet (TLP) interface, the data interface can also be configured to be AXI4 or AHB-Lite interfaces as well. The PCIe hardened block also features a register interface of LMMI and User Configuration Space Register Interface (UCFG). With the soft IP, the interface can be configured to APB or AHB-Lite as well. The PCIe block contains many registers which contains information about the current status of the PCIe block as well as the capability to dynamically switch PCIe settings. One easy way to access these registers is through the Reveal Controller Tool. For more information about the PCIe soft IP, refer to the PCIe Endpoint IP Core document. Top Soft Logic PCIe Hard IP Data Interface Conversion AHB-Lite /APB rxp_i/ rxpn_i Rx TLP AHB-Lite /AXI-4 Tx TLP LMMI Register Interface Conversion Transaction Layer Link Layer UCFG PHY Layer txp_o/ txpn_o refclkp_i/ refclkn_i Figure 2.29. PCIe Soft IP Wrapper © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 48 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 2.22. Cryptographic Engine The CrossLink-NX family of devices support several cryptographic features that helps customer secure their design. Some of the key cryptographic features include Advanced Encryption Standard (AES), Hashing Algorithms and true random number generator (TRNG). The CrossLink-NX device also features bitstream encryption (using AES-256) and bitstream authentication (using ECDSA), which protects the FPGA design bitstream from copying and tampering. The Cryptographic Engine (CRE) is the main engine, which is responsible for the bitstream encryption as well as authentication of the CrossLink-NX device. Once the bitstream is authenticated and the device is ready for user functions, the CRE is available for you to implement various cryptographic functions in your FPGA design. To enable specific cryptographic function, the CRE has to be configured by setting a few registers. The Cryptographic Engine supports the below user-mode features:  True Random Number generator (TRNG)  Secure Hashing Algorithm (SHA)-256 bit  Message authentication codes (MACs) – HMAC  Lattice Memory Mapped Interface (LMMI) interface to user logic  High Speed Port (HSP) for FIFO-based streaming data transfer Cryptographic Engine (CRE) Unique ID Control Register FPGA Fabric LMMI / High Speed Port True Random Number Generator (TRNG) CRE Registers Advanced Encryption Standard (AES) Bitstream Encryption Bitstream Authentication SHA256 HMAC SHA256 Figure 2.30. Cryptographic Engine Block Diagram © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 49 CrossLink-NX Family Preliminary Data Sheet 3. DC and Switching Characteristics 3.1. Absolute Maximum Ratings Table 3.1. Absolute Maximum Ratings Symbol VCC, VCCECLK VCCAUX, VCCAUXA, VCCAUXH3, VCCAUXH4, VCCAUXH5 VCCIO0, 1, 2, 6, 7 VCCIO3, 4, 5 VCCPLL_DPHY0, 1 VCCPLLSD0 VCCA_DPHY0, 1 VCC_DPHY0, 1 VCCSD0 VCCADC18 VCCAUXSD — — — TA Parameter Supply Voltage Supply Voltage Min –0.5 –0.5 Max 1.10 1.98 Unit V V I/O Supply Voltage I/O Supply Voltage Hardened D-PHY PLL Supply Voltage SERDES Block PLL Supply Voltage Analog Supply Voltage for Hardened D-PHY Digital Supply Voltage for Hardened D-PHY SERDES Supply Voltage ADC Block 1.8 V Supply Voltage SERDES and AUX Supply Voltage Input or I/O Voltage Applied, Bank 0, Bank 1,Bank 2, Bank 6, Bank 7 Input or I/O Voltage Applied, Bank 3, Bank 4, Bank 5 Voltage Applied on SERDES Pins Storage Temperature (Ambient) –0.5 –0.5 –0.5 –0.5 –0.5 –0.5 –0.5 –0.5 –0.5 –0.5 3.63 1.98 1.10 1.98 1.98 1.10 1.10 1.98 1.98 3.63 V V V V V V V V V V –0.5 1.98 V –0.5 –65 1.98 150 V °C TJ Junction Temperature — +125 °C Notes: 1. Stress above those listed under the Absolute Maximum Ratings may cause permanent damage to the device. Functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. 2. Compliance with the Lattice Thermal Management document is required. 3. All voltages referenced to GND. 4. All VCCAUX should be connected on PCB. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 50 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 3.2. Recommended Operating Conditions1, 2, 3 Table 3.2. Recommended Operating Conditions Symbol Parameter Conditions Min Typ. Max Unit VCC, VCCECLK Core Supply Voltage 0.95 1.00 1.05 V VCCAUX Auxiliary Supply Voltage 1.746 1.80 1.89 V VCCAUXH3/4/5 Auxiliary Supply Voltage Auxiliary Supply Voltage for core logic VCC = 1.0 Bank 0, Bank 1, Bank 2, Bank 6, Bank 7 Bank 3, Bank 4, Bank 5 1.746 1.80 1.89 V — 1.746 1.80 1.89 V 3.135 3.30 3.465 V 2.375 2.50 2.625 V 1.71 1.425 1.80 1.50 1.89 1.575 V V 1.2825 1.35 1.4175 V VCCIO = 1.2 V, All Banks4 VCCIO = 1.0 V, Bank 3, Bank 4, Bank 5 1.14 1.20 1.26 V 0.95 1.00 1.05 V — 1.71 1.80 1.89 V — — 0.95 0.95 1.00 1.00 1.05 1.05 V V — 1.71 1.80 1.89 V — 0.95 1.00 1.05 V VCCAUXA VCCIO I/O Driver Supply Voltage D-PHY External Power Supplies D-PHY Analog Power VCCA_D-PHY Supply VCC_D-PHY D-PHY Digital Power Supply VCCPLL_D-PHY D-PHY PLL Power Supply ADC External Power Supplies VCCADC18 ADC 1.8 V Power Supply SERDES Block External Power Supplies Supply Voltage for SERDES VCCSD0 Block and SERDES I/O VCCIO = 3.3 V, Bank 0, Bank 1, Bank 2, Bank 6, Bank 7 VCCIO = 2.5 V, Bank 0, Bank 1, Bank 2, Bank 6, Bank 7 VCCIO = 1.8 V, All Banks VCCIO = 1.5 V, All Banks4 VCCIO = 1.35 V, All Banks (For DDR3L Only) SERDES Block PLL Supply — 1.71 1.80 1.89 V Voltage SERDES Block Auxiliary VCCAUXSD — 1.71 1.80 1.89 V Supply Voltage Operating Temperature Junction Temperature, tJCOM — 0 — 85 °C Commercial Operation Junction Temperature, tJIND — –40 — 100 °C Industrial Operation Notes: 1. For correct operation, all supplies must be held in their valid operation voltage range. 2. All supplies with same voltage should be from the same voltage source. Proper isolation filters are needed to properly isolate noise from each other. 3. Common supply rails must be tied together except SERDES. 4. MSPI (Bank0) and JTAG, SSPI, I2C, and I3C (Bank 1) ports are supported for VCCIO = 1.8 V to 3.3 V. VCCPLLSD0 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 51 CrossLink-NX Family Preliminary Data Sheet 3.3. Power Supply Ramp Rates Table 3.3. Power Supply Ramp Rates Symbol Parameter tRAMP Power Supply ramp rates for all supplies 1 Min Typ Max Unit 0.1 — 50 V/ms Notes: 1. Assumes monotonic ramp rates. 2. All supplies need to be in the operating range as defined in Recommended Operating Conditions1, when the device has completed configuration and entering into User Mode. Supplies that are not in the operating range needs to be adjusted to faster ramp rate, or you have to delay configuration or wake up. 3.4. Power up Sequence Power-On-Reset (POR) puts the CrossLink-NX device into a reset state. There is no power up sequence required for the CrossLink-NX device. 3.5. On-Chip Programmable Termination The CrossLink-NX devices support a variety of programmable on-chip terminations options, including:  Dynamically switchable Single-Ended Termination with programmable resistor values of 40 Ω, 50 Ω, 60 Ω, or 75 Ω.  Common mode termination of 100 Ω for differential inputs. Zo = 50 V CCI O Zo = 40 , 50 , 60 , or 75 to VCCIO /2 TERM control Zo Zo Zo + - VREF OFF-chip + 2Zo Zo OFF-chip ON-chip Parallel Single-Ended Input ON-chip Differential Input Figure 3.1. On-Chip Termination See Table 3.4 for termination options for input modes. Table 3.4. On-Chip Termination Options for Input Modes IO_TYPE subLVDS SLVS MIPI_DPHY HSTL15D_I SSTL15D_I SSTL135D_I HSUL12D LVCMOS15H LVCMOS12H Differential Termination Resistor* 100, OFF 100, OFF 100 100, OFF 100, OFF 100, OFF 100, OFF OFF OFF Terminate to VCCIO/2* OFF OFF OFF OFF OFF OFF OFF OFF OFF LVCMOS10H LVCMOS12H LVCMOS10H OFF OFF OFF OFF OFF OFF © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 52 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet IO_TYPE Differential Termination Resistor* Terminate to VCCIO/2* LVCMOS18H OFF OFF, 40, 50, 60, 75 HSTL15_I OFF 50 SSTL15_I OFF OFF, 40, 50, 60, 75 SSTL135_I OFF OFF, 40, 50, 60, 75 HSUL12 OFF OFF, 40, 50, 60, 75 *Notes:  TERMINATE to VCCIO/2 (Single-Ended) and DIFFRENTIAL TERMINATION RESISTOR when turned on can only have one setting per bank. Only left and right banks have this feature.  Use of TERMINATE to VCCIO/2 and DIFFRENTIAL TERMINATION RESISTOR are mutually exclusive in an I/O bank. On-chip termination tolerance –10%/+60%. Refer to CrossLink-NX sysI/O Usage Guide (FPGA-TN-02067) for on-chip termination usage and value ranges. 3.6. Hot Socketing Specifications Table 3.5. Hot Socketing Specifications for GPIO Symbol Parameter Input or I/O Leakage Current for Wide Range I/O (excluding MCLK/MCSN/MOSI/INITN/DONE) IDK Input of I/O Leakage Current for MCLK/MCSN/MOSI/INITN/DONE pins Input or I/O Leakage Current for Bottom Bank Condition 0 < Vin < Vih(max) 0 < Vcc < Vcc(max) 0 < Vccio < Vccio(max) 0 < Vccaux < Vccaux(max) VCCIO < VIN < VCCIO + 0.5 V Min — Typ 1 Max — Unit mA — 20 — mA VCCIO < VIN < VCCIO + 0.5 V — 18 — mA Notes: 1. IDK is additive to IPU, IPW, or IBH. 2. Hot socket specification defines when the hot socketed device's junction temperature is at 85 oC or below. When the hot socketed device's junction temperature is above 85 oC, the IDK current can exceed the above spec. 3. Going beyond the hot socketing ranges specified here will cause exponentially higher Leakage currents and potential reliability issues. A total of 64mA per 8 I/O should not be exceeded. 3.7. ESD Performance Refer to the CrossLink-NX Product Family Qualification Summary for complete qualification data, including ESD performance. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 53 CrossLink-NX Family Preliminary Data Sheet 3.8. DC Electrical Characteristics Table 3.6. DC Electrical Characteristics – Wide Range (Over Recommended Operating Conditions) Symbol IIL, IIH1 IIH2 IPU Parameter Input or I/O Leakage current (Commercial/Industrial) Input or I/O Leakage current I/O Weak Pull-up Resistor Current I/O Weak Pull-down Resistor Current Bus Hold Low Sustaining Current Bus Hold High Sustaining Current Bus hold low Overdrive Current Bus hold high Overdrive Current Bus Hold Trip Points IPD Condition Min Typ Max Unit 0 ≤ VIN ≤ VCCIO — — 10 µA VCCIO ≤ VIN ≤ VIH (max) — — 100 µA 0 ≤ VIN ≤ 0.7 * VCCIO –30 — –150 µA VIL (max) ≤ VIN ≤ VCCIO 30 — 150 µA IBHLS VIN = VIL (max) 30 — µA IBHHS VIN = 0.7 * VCCIO –30 — µA IBHLO 0 ≤ VIN ≤ VCCIO — — 150 µA IBHHO 0 ≤ VIN ≤ VCCIO — — –150 µA VBHT — VIL (max) — VIH (min) V Notes: 1. Input or I/O leakage current is measured with the pin configured as an input or as an I/O with the output tristated. Bus Maintenance circuits are disabled. 2. The input leakage current IIH is the worst case input leakage per GPIO when the pad signal is high and also higher than the bank VCCIO. This is considered a mixed mode input. 3. The hot socket input leakage current IDK specification is shown above. This assumes a monotonic ramp up time of the power supply after it begins to rise and until it reaches its minimum operation level. 4. I/O Pin capacitance from simulations show a typical range of 3-7 pF @ 25°, F=1 MHz and typical conditions with bus maintenance circuits disabled. Table 3.7. DC Electrical Characteristics – High Speed (Over Recommended Operating Conditions) Symbol Parameter Condition IIL, IIH1 IBHLS IBHHS IBHLO IBHHO Input or I/O Leakage I/O Weak Pull-up Resistor Current I/O Weak Pull-down Resistor Current Bus Hold Low Sustaining Current Bus Hold High Sustaining Current Bus hold low Overdrive Current Bus hold high Overdrive Current VBHT Bus Hold Trip Points — IPU IPD Min Typ Max Unit 0 ≤ VIN ≤ VCCIO — 10 µA 0 ≤ VIN ≤ 0.7 * VCCIO –30 — — –150 µA VIL (max) ≤ VIN ≤ VCCIO 30 150 µA — — — — — — 150 –150 µA µA µA µA — VIH (min) V VIN = VIL (max) VIN = 0.7 * VCCIO 0 ≤ VIN ≤ VCCIO 0 ≤ VIN ≤ VCCIO 30 –30 — — VIL (max) — Notes: 1. Input or I/O leakage current is measured with the pin configured as an input or as an I/O with the output tristated. Bus Maintenance circuits are disabled. 2. To be updated after design sims. 3. I/O Pin capacitance from simulations show a typical value of 3 pF @ 25°, F=1 MHz and typical conditions with bus maintenance circuits disabled. Table 3.8. Capacitors – Wide Range (Over Recommended Operating Conditions) Symbol Parameter Condition Min Typ Max Unit C1 * I/O Capacitance* VCCIO = 3.3 V, 2.5 V, 1.8 V, 1.5 V, 1.2 V, VCC = typ., VIO = 0 to VCCIO + 0.2V — 6 — pf C2 * Dedicated Input Capacitance* VCCIO = 3.3 V, 2.5 V, 1.8 V, 1.5 V, 1.2 V, VCC = typ., VIO = 0 to VCCIO + 0.2V — 6 — pf *Note: TA 25 oC, f = 1.0 MHz. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 54 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Table 3.9. Capacitors – High Performance (Over Recommended Operating Conditions) Symbol Parameter Condition Min Typ Max Unit C1 * I/O Capacitance* VCCIO = 1.8 V, 1.5 V, 1.2 V, VCC = typ., VIO = 0 to VCCIO + 0.2V — 6 — pf C2 * Dedicated Input Capacitance* VCCIO = 1.8 V, 1.5 V, 1.2 V, VCC = typ., VIO = 0 to VCCIO + 0.2V — 6 — pf C3 * D-PHY I/O Capacitance VCCA_D-PHY = 1.8 V, VCC = typ., VIO = 0 to VCCA_D-PHY + 0.2V — 5 — pf C4 * SERDES I/O Capacitance VCCSD0 = 1.0 V, VCC = typ., VIO = 0 to VCCSD0 + 0.2 V — 5 — pf *Note: TA 25 oC, f = 1.0 MHz. Table 3.10. Single Ended Input Hysteresis – Wide Range (Over Recommended Operating Conditions) IO_TYPE LVCMOS33 LVCMOS25 LVCMOS18 LVCMOS15 LVCMOS12 LVCMOS10 VCCIO 3.3 V 3.3 V 2.5 V 1.8 V 1.5 V 1.2 V 1.2 V TYP Hysteresis 250 mV 200 mV 250 mV 180 mV 50 mV 0 0 Table 3.11. Single Ended Input Hysteresis – High Performance (Over Recommended Operating Conditions) IO_TYPE LVCMOS18H LVCMOS15H LVCMOS12H LVCMOS10H MIPI-LP-RX 3.9. VCCIO 1.8 V 1.8 V 1.5 V 1.2 V 1.0 V 1.2 V TYP Hysteresis 180 mV 50 mV 150 mV 0 0 > 25 mV 180 mV Supply Currents For estimating and calculating current, use Power Calculator in Lattice Design Software. This operating and peak current is design dependent, and can be calculated in Lattice Design Software. Some blocks can be placed into low current standby modes. Refer to Power Management and Calculation for CrossLink-NX Devices (FPGA-TN-02075). © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 55 CrossLink-NX Family Preliminary Data Sheet 3.10. sysI/O Recommended Operating Conditions Table 3.12. sysI/O Recommended Operating Conditions VCCIO (Input) VCCIO (Output) Typ. Typ. 0, 1, 2, 6, 7 0, 1, 2, 6, 7 0, 1, 2, 6, 7 0, 1, 2, 6, 7 3, 4, 5 0, 1, 2, 6, 7 3, 4, 5 0, 1, 2, 6, 7 3, 4, 5 3.3 3.3 2.5, 3.3 1.2, 1.5, 1.8, 2.5, 3.3 1.8 1.2, 1.5, 1.8, 2.5, 3.3 1.5, 1.8 1.2, 1.5, 1.8, 2.5, 3.3 1.2, 1.357, 1.5, 1.8 3.3 3.3 2.5 1.8 1.8 1.5 1.5 1.2 1.2 LVCMOS10¹ LVCMOS10H¹ LVCMOS10R¹ SSTL135_I, SSTL135_II3 SSTL15_I, SSTL15_II3 HSTL15_I3 HSUL123 MIPI D-PHY LP Input3, 6 Differential6 LVDS 0, 1, 2, 6, 7 3, 4, 5 3, 4, 5 3, 4, 5 3, 4, 5 3, 4, 5 3, 4, 5 3, 4, 5 1.2, 1.5, 1.8, 2.5, 3.3 1.0, 1.2, 1.357, 1.5, 1.8 1.0, 1.2, 1.357, 1.5, 1.8 1.357 1.58 1.58 1.2 1.2 — 1.0 — 1.35 1.58 1.58 1.2 1.2 3, 4, 5 1.8 1.8 LVDSE5 subLVDS 0, 1, 2, 6, 7 3, 4, 5 2.5 — subLVDSE5 0, 1, 2, 6, 7 — 1.8 — Standard Single-Ended LVCMOS33 LVTTL33 LVCMOS25¹, ² LVCMOS18¹, ² LVCMOS18H LVCMOS15¹, ² LVCMOS15H¹ LVCMOS12¹, ² LVCMOS12H¹ Support Banks 1.8 — 3, 4, 5 1.8 subLVDSEH5 6 7 4 SLVS 3, 4, 5 1.0, 1.2, 1.35 , 1.5, 1.8 1.2, 1.357, 1.5, 1.8 4 6 MIPI D-PHY 3, 4, 5 1.2 1.2 5 LVCMOS33D 0, 1, 2, 6, 7 — 3.3 LVTTL33D5 0, 1, 2, 6, 7 — 3.3 LVCMOS25D5 0, 1, 2, 6, 7 — 2.5 5 SSTL135D_I, SSTL135D_II 3, 4, 5 — 1.357 5 SSTL15D_I, SSTL15D_II 3, 4, 5 — 1.5 HSTL15D_I5 3, 4, 5 — 1.5 5 HSUL12D 3, 4, 5 — 1.2 Notes: 1. Single-ended input can mix into I/O Banks with VCCIO different from the standard requires due to some of these input standards use internal supply voltage source (VCC, VCCAUX) to power the input buffer, which makes them to be independent of VCCIO voltage. For more details, please refer to CrossLink-NX sysI/O Usage Guide (FPGA-TN-02067). The following is a brief guideline to follow: a. Weak pull-up on the I/O must be set to OFF. b. Bank 3, Bank 4, and Bank 5 I/O can only mix into banks with VCCIO higher than the pin standard, due to clamping diode on the pin in these banks. Bank 0, Bank 1, Bank 2, Bank 6, and Bank 7 does not have this restriction. c. LVCMOS25 uses VCCIO supply on input buffer in Bank 0, Bank 1, Bank 2, Bank 6, and Bank 7. It can be supported with VCCIO = 3.3 V to meet the VIH and VIL requirements, but there is additional current drawn on VCCIO. Hysteresis has to be disabled when using 3.3 V supply voltage. d. LVCMOS15 uses VCCIO supply on input buffer in Bank 3, Bank 4, and Bank 5. It can be supported with VCCIO = 1.8 V to meet the VIH and VIL requirements, but there is additional current drawn on VCCIO. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 56 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 2. 3. 4. 5. 6. 7. 8. Single-ended LVCMOS inputs can mixed into I/O Banks with different VCCIO, providing weak pull-up is not used. For additional information on Mixed I/O in Bank VCCIO, refer to CrossLink-NX sysI/O Usage Guide (FPGA-TN-02067). These inputs use differential input comparator in Bank 3, Bank 4, and Bank 5. The differential input comparator uses VCCAUXH power supply. These inputs require the VREF pin to provide the reference voltage in the Bank. Refer to CrossLink-NX sysI/O Usage Guide (FPGA-TN-02067) for details. All differential inputs use differential input comparator in Bank 3, Bank 4, and Bank 5. The differential input comparator uses VCCAUXH power supply. There is no differential input signaling supported in Bank 0, Bank 1, Bank 2, Bank 6, and Bank 7. These outputs are emulating differential output pair with single-ended output drivers with true and complement outputs driving on each of the corresponding true and complement output pair pins. The common mode voltage, VCM, is ½ * VCCIO. Refer to CrossLink-NX sysI/O Usage Guide (FPGA-TN-02067) for details. Soft MIPI D-PHY HS using sysI/O is supported with SLVS input and output that can be placed in banks with VCCIO voltage shown in SLVS. D-PHY with HS and LP modes supported needs to be placed in banks with VCCIO voltage = 1.2 V. Soft MIPI D-PHY LP input and output using sysI/O are supported with LVCMOS12. VCCIO = 1.35 V is only supported in Bank 3, Bank 4, and Bank 5, for use with DDR3L interface in the bank. These Input and Output standards can fit into the same bank with the VCCIO = 1.35 V. LVCMOS15 input uses VCCIO supply voltage. If VCCIO is 1.8 V, the DC levels for LVCMOS15 are still met, but there could be increase in input buffer current. 3.11. sysI/O Single-Ended DC Electrical Characteristics Table 3.13. sysI/O DC Electrical Characteristics – Wide Range I/O (Over Recommended Operating Conditions) Input/Output Standard LVTTL33 LVCMOS33 LVCMOS25 LVCMOS18 LVCMOS15 Min (V) VIL¹ Max (V) 0.8 0.7 0.35 * VCCIO 0.35 * VCCIO VIH¹ Min (V) Max (V) 2.0 3.465 1.7 0.65 * VCCIO 0.65 * VCCIO 2.625 1.9 1.575 LVCMOS12 0.35 * VCCIO 0.65 * VCCIO 1.26 LVCMOS10 0.3 * VCCIO 0.7 * VCCIO 1.05 VOL Max (V) VOH Min² (V) IOL(mA) IOH(mA) 0.4 VCCIO – 0.4 2, 4, 8, 12 -2, -4, -8, -12 0.2 VCCIO – 0.2 0.1 0.1 2, 4, 8, 10 -2, -4, -8, -10 0.4 VCCIO – 0.4 0.2 VCCIO – 0.2 0.1 0.1 0.4 VCCIO – 0.4 2, 4, 8 -2, -4, -8 0.2 VCCIO – 0.2 0.1 0.1 -2, -4, -8, -12 0.4 VCCIO – 0.4 2, 4 0.2 VCCIO – 0.2 0.1 0.1 0.4 VCCIO – 0.4 2, 4 -2, -4, -8, -12 0.2 VCCIO – 0.2 0.1 0.1 No O/P Support Notes: 1. VCCIO for input level refers to the supply rail level associated with a given input standard or the upstream driver VCCIO rail levels. 2. VCCIO for the output levels refer to the VCCIO of the CrossLink-NX device. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 57 CrossLink-NX Family Preliminary Data Sheet Table 3.14. sysI/O DC Electrical Characteristics – High Performance I/O (Over Recommended Operating Conditions) Input/Output Standard LVCMOS18H VIL¹ Min (V) Max (V) 0.35 * VCCIO VIH¹ Min (V) Max (V) 0.65 * VCCIO 1.9 LVCMOS15H 0.35 * VCCIO 0.65 * VCCIO 1.575 LVCMOS12H 0.35 * VCCIO 0.65 * VCCIO 1.26 LVCMOS10H 0.3 * VCCIO 0.7 * VCCIO 1.05 VOL Max (V) VOH Min² (V) IOL (mA) IOH (mA) 0.4 VCCIO – 0.4 2, 4, 8, 12 -2, -4, -8, -12 0.2 VCCIO – 0.2 0.1 -0.1 0.4 VCCIO – 0.4 2, 4, 8 -2, -4, -8 0.2 VCCIO – 0.2 0.1 -0.1 0.4 VCCIO – 0.4 2, 4, 8 -2, -4, -8 0.2 VCCIO – 0.2 0.1 -0.1 0.25 * VCCIO 0.75 * VCCIO 2, 4 -2, -4 0.1 VCCIO – 0.1 0.1 -0.1 SSTL15_I VREF – 0.10 VREF + 0.1 1.575 0.30 VCCIO – 0.30 7.5 –7.5 SSTL15_II VREF – 0.10 VREF + 0.1 1.575 0.30 VCCIO – 0.30 8.8 –8.8 HSTL15_I VREF – 0.10 VREF + 0.1 1.575 0.40 VCCIO – 0.40 8 –8 SSTL135_I VREF – 0.09 VREF + 0.09 1.418 0.27 VCCIO – 0.27 6.75 –6.75 SSTL135_II VREF – 0.09 VREF + 0.09 1.418 0.27 VCCIO – 0.27 8 –8 LVCMOS10R VREF – 0.10 VREF + 0.10 1.05 — — — — HSUL12 VREF – 0.10 VREF + 0.10 1.26 0.3 VCCIO – 0.3 8.8, 7.5, 6.25, 5 -8.8, -7.5, -6.25, -5 Notes: 1. VCCIO for input level refers to the supply rail level associated with a given input standard or the upstream driver VCCIO rail levels. 2. VCCIO for the output levels refer to the VCCIO of the CrossLink-NX device. Table 3.15. I/O Resistance Characteristics (Over Recommended Operating Conditions) Parameter 50RS RDIFF Description Output Drive Resistance when 50RS Drive Strength Selected Test Conditions Input Differential Termination Resistance Bank 3, Bank 4, and Bank 5, for I/O selected to be differential VCCIO = 1.8 V, 2.5 V, or 3.3 V Min Typ Max Unit — 50 — Ω 100 Ω © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 58 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 3.12. sysI/O Differential DC Electrical Characteristics 3.12.1. LVDS LVDS input buffer on CrossLink-NX is operating with VCCAUX = 1.8 V and independent of Bank VCCIO voltage. LVDS output buffer is powered by the Bank VCCIO at 1.8 V. LVDS can only be supported in Bank 3, Bank 4, and Bank 5. LVDS25 output can be emulated with LVDS25E in Bank 0, Bank 1, Bank 2, Bank 6, and Bank 7. This is described in LVDS25E (Output Only) section. Table 3.16. LVDS DC Electrical Characteristics (Over Recommended Operating Conditions)1 Parameter VINP, VINM VICM VTHD IIN VOH VOL VOD Test Conditions — Half the sum of the two Inputs Difference between the two Inputs Power On or Power Off RT = 100 Ω RT = 100 Ω (VOP - VOM), RT = 100 Ω VOCM Description Input Voltage Input Common Mode Voltage Differential Input Threshold Input Current Output High Voltage for VOP or VOM Output Low Voltage for VOP or VOM Output Voltage Differential Change in VOD Between High and Low Output Common Mode Voltage VOCM Change in VOCM, VOCM(MAX) - VOCM(MIN) — ISAB Output Short Circuit Current VOD — (VOP + VOM)/2, RT = 100 Ω VOD = 0 V Driver outputs shorted to each other — Min 0 0.05 ±100 — — 0.9 V 250 Typ — — — — 1.425 1.075 350 Max 1.60 1.55 2 — ±10 1.60 — 450 Unit V V mV µA V V mV — — 50 mV 1.125 1.25 1.375 V — — 50 mV — — 12 mA Change in VOS between H and L — — 50 mV VOS Note: 1. LVDS input or output are supported in Bank 3, Bank 4, and Bank 5. LVDS input uses VCCAUX on the differential input comparator, and can be located in any VCCIO voltage bank. LVDS output uses VCCIO on the differential output driver, and can only be located in bank with VCCIO = 1.8 V. 2. VICM is depending on VID, input differential voltage, so the voltage on pin cannot exceed VINP/INN(min/max) requirements. VICM(min) = VINP/INN(min) + ½ VID, VICM(max) = VINP/INN(max) – ½ VID. Values in the table is based on minimum VID of +/- 100 mV. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 59 CrossLink-NX Family Preliminary Data Sheet 3.12.2. LVDS25E (Output Only) Three sides of the CrossLink-NX devices, Top, Left and Right, support LVDS25 outputs with emulated complementary LVCMOS outputs in conjunction with a parallel resistor across the driver outputs. The scheme shown in Figure 3.2 is one possible solution for point-to-point signals. Table 3.17. LVDS25E DC Conditions Parameter Description Typical Unit VCCIO Output Driver Supply (±5%) 2.50 V ZOUT Driver Impedance 20 Ω RS Driver Series Resistor (±1%) 158 Ω RP Driver Parallel Resistor (±1%) 140 Ω RT Receiver Termination (±1%) 100 Ω VOH Output High Voltage 1.43 V VOL Output Low Voltage 1.07 V VOD Output Differential Voltage 0.35 V VCM Output Common Mode Voltage 1.25 V ZBACK Back Impedance 100.5 Ω IDC DC Output Current 6.03 mA Figure 3.2. LVDS25E Output Termination Example © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 60 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 3.12.3. SubLVDS (Input Only) SubLVDS is a reduced-voltage form of LVDS signaling, very similar to LVDS. It is a standard used in many camera types of applications, and follow the SMIA 1.0, Part 2: CCP2 Specification. Being similar to LVDS, the CrossLink-NX devices can support the subLVDS input signaling with the same LVDS input buffer. The output for subLVDS is implemented in subLVDSE/subLVDSEH with a pair of LVCMOS18 output drivers (see SubLVDSE/SubLVDSEH (Output Only) section). Table 3.18. SubLVDS Input DC Electrical Characteristics (Over Recommended Operating Conditions) Parameter Description Test Conditions Min Typ Max Unit VID Input Differential Threshold Voltage Over VICM range 70 150 200 mV VICM Input Common Mode Voltage Half the sum of the two Inputs 0.4 0.9 1.4 V Figure 3.3. SubLVDS Input Interface 3.12.4. SubLVDSE/SubLVDSEH (Output Only) SubLVDS output uses a pair of LVCMOS18 drivers with True and Complement outputs. The VCCIO of the bank used for subLVDSE or subLVDSEH needs to be powered by 1.8V. SubLVDSE is for Bank 0, Bank 1, Bank 2, Bank 5, and Bank 6; and subLVDSEH is for Bank 3, Bank 4, and Bank 5. Performance of the subLVDSE/subLVDSEH driver is limited to the performance of LVCMOS18. Table 3.19. SubLVDS Output DC Electrical Characteristics (Over Recommended Operating Conditions) Parameter Description Test Conditions Min Typ Max Unit VOD Output Differential Voltage Swing — — 150 — mV VOCM Output Common Mode Voltage Half the sum of the two Outputs — 0.9 — V Figure 3.4. SubLVDS Output Interface © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 61 CrossLink-NX Family Preliminary Data Sheet 3.12.5. SLVS Scalable Low-Voltage Signaling (SLVS) is based on a point-to-point signaling method defined in the JEDEC JESD8-13 (SLVS-400) standard. This standard evolved from the traditional LVDS standard with smaller voltage swings and a lower common-mode voltage. The 200 mV (400 mV p-p) SLVS swing contributes to a reduction in power. The CrossLink-NX devices receive SLVS differential input with the LVDS input buffer. This LVDS input buffer is design to cover wide input common mode range that can meet the SLVS input standard specified by the JEDEC standard. Table 3.20. SLVS Input DC Characteristics (Over Recommended Operating Conditions) Parameter Description Test Conditions Min VID Input Differential Threshold Voltage Over VICM range 70 VICM Input Common Mode Voltage Half the sum of the two Inputs 70 Typ Max Unit — — mV 200 330 mV The SLVS output on CrossLink-NX is supported with the LVDS drivers found in Bank 3, Bank 4, and Bank 5. The LVDS driver on CrossLink-NX is a current controlled driver. It can be configured as LVDS driver, or configured with the 100 Ω differential termination with center-tap set to VOCM at 200 mV. This means the differential output driver can be placed into bank with VCCIO = 1.2 V, 1.5 V, or 1.8 V, even if it is powered by VCCIO. Table 3.21. SLVS Output DC Characteristics (Over Recommended Operating Conditions) Parameter Description Test Conditions Min VCCIO Bank VCCIO — –5% VOD VOCM ZOS Output Differential Voltage Swing Output Common Mode Voltage Single-Ended Output Impedance — Half the sum of the two Outputs — 140 150 40 Typ 1.2, 1.5, 1.8 200 200 50 Max Unit + 5% V 270 250 62.5 mV mV Ω Figure 3.5. SLVS Interface © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 62 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 3.12.6. Soft MIPI D-PHY When Soft D-PHY is implemented inside the FPGA logic, the I/O interface needs to use sysI/O buffers to connect to external D-PHY pins. The CrossLink-NX sysI/O provides support of SLVS, as described in SLVS section, plus the LVCMOS12 input / output buffers together to support the High Speed (HS) and Low Power (LP) mode as defined in MIPI Alliance Specification for D-PHY. To support MIPI D-PHY with SLVS (LVDS) and LVCMOS12, the bank VCCIO cannot be set to 1.5 V or 1.8 V. It has to connect to 1.2 V, or 1.1 V. All other DC parameters are the same as listed in SLVS section. DC parameters for the LP driver and receiver are the same as listed in LVCMOS12. LVCMOS12 LP Data_P LPenable HSenable MIPI Receiver 100 + Diff + HS Data Z0=50 - - SLVS LPenable LP Data_N LVCMOS12 MIPI_LP_RX On-Chip RXLP_P MIPI Divider + + Z0=50 HS Data - - LVDS MIPI_LP_RX RXLP_N Figure 3.6. MIPI Interface © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 63 CrossLink-NX Family Preliminary Data Sheet Table 3.22. Soft D-PHY Input Timing and Levels Symbol Description High Speed (Differential) Input DC Specifications VCMRX(DC) Common-mode Voltage in High Speed Mode Conditions Min Typ Max Unit VIDTH Differential Input HIGH Threshold VIDTL Differential Input LOW Threshold VIHHS Input HIGH Voltage (for HS mode) VILHS Input LOW Voltage VTERM-EN Single-ended voltage for HS Termination Enable4 ZID Differential Input Impedance High Speed (Differential) Input AC Specifications ΔVCMRX(HF)1 Common-mode Interference (>450 MHz) ΔVCMRX(LF)2, 3 Common-mode Interference (50 MHz - 450 MHz) CCM Common-mode Termination Low Power (Single-Ended) Input DC Specifications VIH Low Power Mode Input HIGH Voltage VIL Low Power Mode Input LOW Voltage VIL-ULP Ultra Low Power Input LOW Voltage VHYST Low Power Mode Input Hysteresis ℮SPIKE Input Pulse Rejection TMIN-RX Minimum Pulse Width Response VINT Peak Interference Amplitude fINT Interference Frequency Contention Detector (LP-CD) DC Specifications VIHCD Contention Detect HIGH Voltage — 70 — 330 mV — — — — — — 70 — — –40 — 80 — — — — — 100 — -70 460 — 450 125 mV mV mV mV mV Ω — — — — –50 — — 100 50 60 mV mV pF — — — — — — — — 740 — — 25 — 20 — 450 — — — — — — — — — 550 300 — 300 — 200 — mV mV mV mV V∙ps ns mV MHz — 450 — — mV 200 mV VILCD Contention Detect LOW Voltage — — — Notes: 1. This is peak amplitude of sine wave modulated to the receiver inputs. 2. Input common-mode voltage difference compared to average common-mode voltage on the receiver inputs. 3. Exclude any static ground shift of 50 mV. 4. High Speed Differential RTERM is enabled when both DP and DN are below this voltage. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 64 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Table 3.23. Soft D-PHY Output Timing and Levels Symbol Description High Speed (Differential) Output DC Specifications VCMTX Common-mode Voltage in High Speed Mode |ΔVCMTX(1,0)| VCMTX Mismatch Between Differential HIGH and LOW |VOD| Output Differential Voltage VOD Mismatch Between Differential HIGH and LOW VOHHS Single-Ended Output HIGH Voltage ZOS Single Ended Output Impedance ΔZOS ZOS mismatch High Speed (Differential) Output AC Specifications ΔVCMTX(LF) Common-Mode Variation, 50 MHz – 450 MHz ΔVCMTX(HF) Common-Mode Variation, above 450 MHz |ΔVOD| Output 20% - 80% Rise Time Output 80% - 20% Fall Time tR tF Output Data Valid After CLK Output Low Power (Single-Ended) Output DC Specifications VOH Low Power Mode Output HIGH Voltage VOL Low Power Mode Input LOW Voltage ZOLP Output Impedance in Low Power Mode Low Power (Single-Ended) Output AC Specifications tRLP 15% - 85% Rise Time tFLP 85% - 15% Fise Time tREOT HS – LP Mode Rise and Fall Time, 30% - 85% TLP-PULSE-TX Pulse Width of the LP Exclusive-OR Clock TLP-PER-TX CLOAD Period of the LP Exclusive-OR Clock Load Capacitance Conditions Min Typ Max Unit — 150 200 250 mV — — 5 mV 140 200 270 mV — — 10 mV — — — — 360 — — 50 — 20 mV Ω % — — 0.08 Gbps ≤ tR ≤ 1.00 Gbps 1.00 Gbps < tR ≤ 1.50 Gbps 0.08 Gbps ≤ tF ≤ 1.00 Gbps 1.00 Gbps < tF ≤ 1.50 Gbps — — — — 25 15 mVRMS mVRMS — — 0.30 UI — — 0.35 UI — — 0.30 UI — — 0.35 UI 0.08 Gbps – 1.5 Gbps 1.1 1.2 1.3 V — — –50 110 — — 50 — mV Ω — — — — — — 25 25 35 ns ns ns 40 — — ns 20 90 0 — — — — — 70 ns ns pF Min Typ Max Unit — — 12.5 ns — –10% — 10% UI — –5% — 5% UI — |D-PHY-P – D-PHYN| — — — — 1st LP XOR Clock Pulse after STOP State or Last Pulse before STOP State All Other Pulses — — Table 3.24. Soft D-PHY Clock Signal Specification Symbol Description Conditions Clock Signal Specification UI Instantaneous UIINST UI Variation ∆UI — © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 65 CrossLink-NX Family Preliminary Data Sheet Table 3.25. Soft D-PHY Data-Clock Timing Specifications Symbol Description Conditions Min Typ Max Unit 0.08 Gbps ≤ TSKEW[TX] ≤ 1.00 Gbps -0.15 — 0.15 UIINST 1.00 Gbps < TSKEW[TX] ≤ 1.50 Gbps -0.20 — 0.20 UIINST 0.08 Gbps ≤ TSKEW[TLIS] ≤ 1.00 Gbps -0.20 — 0.20 UIINST 1.00 Gbps < TSKEW[TLIS] ≤ 1.50 Gbps -0.10 — 0.10 UIINST 0.08 Gbps ≤ TSETUP[RX] ≤ 1.00 Gbps 0.15 — — UI 1.00 Gbps < TSETUP[RX] ≤ 1.50 Gbps 0.20 — — UI 0.08 Gbps ≤ THOLD[RX] ≤ 1.00 Gbps 0.15 — — UI 1.00 Gbps < THOLD[RX] ≤ 1.50 Gbps 0.20 — — UI Data-Clock Timing Specifications TSKEW[TX] TSKEW[TLIS] TSETUP[RX] THOLD[RX] Data to Clock Skew Data to Clock Skew Input Data Setup Before CLK Input Data Hold After CLK 3.12.7. Differential HSTL15D (Output Only) Differential HSTL outputs are implemented as a pair of complementary single-ended HSTL outputs. 3.12.8. Differential SSTL135D, SSTL15D (Output Only) Differential SSTL is used for differential clock in DDR3/DDR3L memory interface. All differential SSTL outputs are implemented as a pair of complementary single-ended SSTL outputs. All allowable single-ended output classes (class I and class II) are supported. 3.12.9. Differential HSUL12D (Output Only) Differential HSUL is used for differential clock in LPDDR2/LPDDR3 memory interface. All differential HSUL outputs are implemented as a pair of complementary single-ended HSUL12 outputs. All allowable single-ended drive strengths are supported. 3.12.10. Differential LVCMOS25D, LVCMOS33D, LVTTL33D (Output Only) Differential LVCMOS and LVTTL outputs are implemented as a pair of complementary single-ended outputs. All allowable single-ended output drive strengths are supported. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 66 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 3.13. CrossLink-NX Maximum sysI/O Buffer Speed Over recommended operating conditions. Table 3.26. CrossLink-NX Maximum I/O Buffer Speed1, 2, 3, 4, 7 Buffer Description Banks Max Unit Maximum sysI/O Input Frequency Single-Ended LVCMOS33 LVCMOS33, VCCIO = 3.3 V 0, 1, 2, 6, 7 200 MHz LVTTL33 LVTTL33, VCCIO = 3.3 V 0, 1, 2, 6, 7 200 MHz LVCMOS25 LVCMOS25, VCCIO = 2.5 V 0, 1, 2, 6, 7 200 MHz 5 LVCMOS18, VCCIO = 1.8 V 0, 1, 2, 6, 7 200 MHz LVCMOS18H LVCMOS18, VCCIO = 1.8 V 3, 4, 5 200 MHz 5 LVCMOS15, VCCIO = 1.5 V 0, 1, 2, 6, 7 100 MHz LVCMOS15, VCCIO = 1.5 V 3, 4, 5 150 MHz LVCMOS12, VCCIO = 1.2 V 0, 1, 2, 6, 7 50 MHz LVCMOS12, VCCIO = 1.2 V 3, 4, 5 100 MHz LVCMOS18 LVCMOS15 LVCMOS15H 5 LVCMOS12 5 LVCMOS12H 5 LVCMOS10 5 LVCMOS 1.0, VCCIO = 1.2 V 0, 1, 2, 6, 7 50 MHz LVCMOS10H 5 LVCMOS 1.0, VCCIO = 1.0 V 3, 4, 5 50 MHz LVCMOS10R LVCMOS 1.0, VCCIO independent 3, 4, 5 50 MHz SSTL15_I, SSTL15_II SSTL_15, VCCIO = 1.5 V 3, 4, 5 1066 Mbps SSTL135_I, SSTL135_II SSTL_135, VCCIO = 1.35 V 3, 4, 5 1066 Mbps HSUL12 HSUL_12, VCCIO = 1.2 V 3, 4, 5 1066 Mbps HSTL15 HSTL15, VCCIO = 1.5 V 3, 4, 5 250 Mbps MIPI D-PHY (LP Mode) MIPI, Low Power Mode, VCCIO = 1.2 V 3, 4, 5 10 Mbps LVDS, VCCIO independent QFN72, caBGA256, csBGA289, and caBGA400 3, 4, 5 1250 Mbps LVDS, VCCIO independent csfBGA121 3, 4, 5 1500 Mbps subLVDS, VCCIO independent QFN72, caBGA256, csBGA289, and caBGA400 3, 4, 5 1250 Mbps subLVDS, VCCIO independent csfBGA121 3, 4, 5 1500 Mbps SLVS similar to MIPI HS, VCCIO independent QFN72, caBGA256, csBGA289, caBGA400 3, 4, 5 1250 Mbps SLVS similar to MIPI HS, VCCIO independent csfBGA121 3, 4, 5 1500 Mbps MIPI, High Speed Mode, VCCIO = 1.2 V QFN72, caBGA256, csBGA289, caBGA400 3, 4, 5 1250 Mbps MIPI, High Speed Mode, VCCIO = 1.2 V csfBGA121 3, 4, 5 15008 Mbps SSTL15D Differential SSTL15, VCCIO independent 3, 4, 5 1066 Mbps SSTL135D Differential SSTL135, VCCIO independent 3, 4, 5 1066 Mbps HUSL12D Differential HSUL12, VCCIO independent 3, 4, 5 1066 Mbps HSTL15D Differential HSTL15, VCCIO independent 3, 4, 5 250 Mbps Differential LVDS subLVDS SLVS MIPI D-PHY (HS Mode) © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 67 CrossLink-NX Family Preliminary Data Sheet Buffer Description Banks Max Unit Maximum sysI/O Output Frequency Single-Ended LVCMOS33 (all drive strengths) LVCMOS33, VCCIO = 3.3 V 0, 1, 2, 6, 7 200 MHz LVCMOS33 (RS50) LVCMOS33, VCCIO = 3.3 V, RSERIES = 50 Ω 0, 1, 2, 6, 7 200 MHz LVTTL33 (all drive strengths) LVTTL33, VCCIO = 3.3 V 0, 1, 2, 6, 7 200 MHz LVTTL33 (RS50) LVTTL33, VCCIO = 3.3 V, RSERIES = 50 Ω 0, 1, 2, 6, 7 200 MHz LVCMOS25 (all drive strengths) LVCMOS25, VCCIO = 2.5 V 0, 1, 2, 6, 7 200 MHz LVCMOS25 (RS50) LVCMOS25, VCCIO = 2.5 V, RSERIES = 50 Ω 0, 1, 2, 6, 7 200 MHz LVCMOS18 (all drive strengths) LVCMOS18, VCCIO = 1.8 V 0, 1, 2, 6, 7 200 MHz LVCMOS18 (RS50) LVCMOS18, VCCIO = 1.8 V, RSERIES = 50 Ω 0, 1, 2, 6, 7 200 MHz LVCMOS18H (all drive strengths) LVCMOS18, VCCIO = 1.8 V 3, 4, 5 200 MHz LVCMOS18H (RS50) LVCMOS18, VCCIO = 1.8 V, RSERIES = 50 Ω 3, 4, 5 200 MHz LVCMOS15 (all drive strengths) LVCMOS15, VCCIO = 1.5 V 0, 1, 2, 6, 7 100 MHz LVCMOS15H (all drive strengths) LVCMOS15, VCCIO = 1.5 V 3, 4, 5 150 MHz LVCMOS12 (all drive strengths) LVCMOS12, VCCIO = 1.2 V 0, 1, 2, 6, 7 50 MHz LVCMOS12H (all drive strengths) LVCMOS12, VCCIO = 1.2 V 3, 4, 5 100 MHz LVCMOS10H (all drive strengths) LVCMOS12, VCCIO = 1.2 V 3, 4, 5 50 MHz SSTL15_I, SSTL15_II SSTL_15, VCCIO = 1.5 V 3, 4, 5 1066 Mbps SSTL135_I, SSTL135_II SSTL_135, VCCIO = 1.35 V 3, 4, 5 1066 Mbps HSUL12 (all drive strengths) HSUL_12, VCCIO = 1.2 V 3, 4, 5 1066 Mbps HSTL15 HSTL15, VCCIO = 1.5 V 3, 4, 5 250 Mbps MIPI D-PHY (LP Mode) MIPI, Low Power Mode, VCCIO = 1.2 V 3, 4, 5 10 Mbps LVDS, VCCIO = 1.8 V QFN72, caBGA256, csBGA289, and caBGA400 LVDS, VCCIO = 1.8 V csfBGA121 3, 4, 5 1250 Mbps 3, 4, 5 1500 Mbps Differential LVDS LVDS25E6 LVDS25, Emulated, VCCIO = 2.5 V 0, 1, 2, 6, 7 400 Mbps SubLVDSE6 subLVDS, Emulated, VCCIO = 1.8 V 0, 1, 2, 6, 7 400 Mbps SubLVDSEH6 subLVDS, Emulated, VCCIO = 1.8 V 3, 4, 5 800 Mbps SLVS SLVS similar to MIPI, VCCIO = 1.2 V QFN72, caBGA256, csBGA289, caBGA400 3, 4, 5 1250 3, 4, 5 1500 3, 4, 5 1250 MIPI, High Speed Mode, VCCIO = 1.2 V csfBGA121 3, 4, 5 15008 SSTL15D Differential SSTL15, VCCIO = 1.5 V 3, 4, 5 1066 Mbps SSTL135D Differential SSTL135, VCCIO = 1.35 V 3, 4, 5 1066 Mbps HUSL12D Differential HSUL12, VCCIO = 1.2 V 3, 4, 5 1066 Mbps HSTL15D Differential HSTL15, VCCIO = 1.5 V 3, 4, 5 250 Mbps SLVS similar to MIPI, VCCIO = 1.2 V csfBGA121 MIPI D-PHY (HS Mode) MIPI, High Speed Mode, VCCIO = 1.2 V QFN72, caBGA256, csBGA289, caBGA400 Mbps Mbps Mbps Mbps Notes: 1. Maximum I/O speed is the maximum switching rate of the I/O operating within the guidelines of the defining standard. The actual interface speed performance using the I/O also depends on other factors, such as internal and external timing. 2. These numbers are characterized but not test on every device. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 68 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 3. 4. 5. 6. 7. 8. Performance is specified in MHz, as defined in clock rate when the sysI/O is used as pin. For data rate performance, this can be converted to Mbps, which equals to 2 times the clock rate. LVCMOS and LVTTL are measured with load specified in Table 3.46. These LVCMOS inputs can be placed in different VCCIO voltage. Performance may vary. Please refer to Lattice Design Software These emulated outputs performance is based on externally properly terminated as described in LVDS25E (Output Only) and SubLVDSE/SubLVDSEH (Output Only). All speeds are measured with fast slew. Subject to verification when package becomes available. 3.14. Typical Building Block Function Performance These building block functions can be generated using Lattice Design Software Tool. Exact performance may vary with the device and the design software tool version. The design software tool uses internal parameters that have been characterized but are not tested on every device. Table 3.27. Pin-to-Pin Performance Typ. @ VCC = 1.0 V Unit 16-Bit Decoder (I/O configured with LVCMOS18, Left and Right Banks) 7.1 ns 16-Bit Decoder (I/O configured with HSTL15_I, Bottom Banks) 5.2 ns 16:1 Mux (I/O configured with LVCMOS18, Left and Right Banks) 7.9 ns 6 ns Function 16:1 Mux (I/O configured with HSTL15_I, Bottom Banks) Note: These functions are generated using Lattice Radiant Design Software tool. Exact performance may vary with the device and the design software tool version. The design software tool uses internal parameters that have been characterized but are not tested on every device. Table 3.28. Register-to-Register Performance Typ. @ VCC = 1.0 V Unit 16-Bit Adder 5002 MHz 32-Bit Adder 407 MHz 16-Bit Counter 325 MHz 32-Bit Counter 303 MHz 512 x 36 Single Port RAM, with Output Register 5002 MHz 1024 x 18 True-Dual Port RAM using same clock, with EBR Output Registers 5002 MHz 1024 x 18 True-Dual Port RAM using asynchronous clocks, with EBR Output Registers 5002 MHz 32K x 32 Single Port RAM, with Output Register 1472 MHz 32K x 32 Single Port RAM with ECC, with Output Register 1162 MHz 32K x 32 True-Dual Port RAM using same clock, with EBR Output Registers 340 MHz 16 x 4 Single Port RAM (One PFU) 5002 MHz 16 x 2 Pseudo-Dual Port RAM (One PFU) 5002 MHz 16 x 4 Pseudo-Dual Port (Two PFUs) 5002 MHz 9 x 9 Multiplier with Input Output Registers 351 MHz 9 x 9 Multiplier with Input/Pipelined/Output Registers 218 MHz 18 x 18 Multiplier with Input/Output Registers 248 MHz 18 x 18 Multiplier with Input/Pipelined/Output Registers 191 MHz Function Basic Functions Embedded Memory Functions Large Memory Functions Distributed Memory Functions DSP Functions © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 69 CrossLink-NX Family Preliminary Data Sheet Typ. @ VCC = 1.0 V Unit 36 x 36 Multiplier with Input/Output Registers 190 MHz 36 x 36 Multiplier with Input/Pipelined/Output Registers 119 MHz MAC 9 x 9 with Input/Output Registers 206 MHz MAC 9 x 9 with Input/Pipelined/Output Registers 223 MHz Function Notes: 1. The Clock port is configured with LVDS I/O type. Performance Grade: 9_High-Performance_1.0V. 2. Limited by the Minimum Pulse Width of the component 3. These functions are generated using Lattice Radiant Design Software tool. Exact performance may vary with the device and the design software tool version. The design software tool uses internal parameters that have been characterized but are not tested on every device. 4. For the Pipelined designs, the number of pipeline stages used are 2. 3.15. Derating Timing Tables Logic timing provided in the following sections of this data sheet and the Lattice Radiant design tools are worst case numbers in the operating range. Actual delays at nominal temperature and voltage for best case process, can be much better than the values given in the tables. The Lattice Radiant design tool can provide logic timing numbers at a particular temperature and voltage. 3.16. CrossLink-NX External Switching Characteristics Over recommended commercial operating conditions. Table 3.29. CrossLink-NX External Switching Characteristics (VCC = 1.0 V) Parameter Description –9 –8 –7 Unit Min Max Min Max Min Max — 400 — 325.2 — 276 MHz 0.8 — 0.8 — 0.8 — ns — 450 — 554 — 653 ps — 800 — 650.4 — 551.7 MHz 0.588 — 0.723 — 0.852 — ns — 120 — 148 — 174 ps Generic SDR Input General I/O Pin Parameters Using Dedicated Primary Clock Input without PLL Clock to Output - PIO tCO — 5.40 — Output Register Clock to Data Setup - PIO tSU 0 — 0 Input Register 6.64 — 7.83 ns — 0 — ns Clocks Primary Clock fMAX_PRI tW_PRI tSKEW_PRI Edge Clock fMAX_EDGE tW_EDGE tSKEW_EDGE tH tSU_DEL Frequency for Primary Clock Clock Pulse Width for Primary Clock Primary Clock Skew Within a Device Frequency for Edge Clock Tree Clock Pulse Width for Edge Clock Edge Clock Skew Within a Device Clock to Data Hold - PIO Input Register Clock to Data Setup - PIO Input Register with Data Input Delay 2.70 — 3.32 — 3.92 — ns 1.20 — 1.48 — 1.74 — ns © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 70 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Parameter Description –9 Min –8 Max Clock to Data Hold - PIO 0 — Input Register with Data Input Delay General I/O Pin Parameters Using Dedicated Primary Clock Input with PLL tCOPLL Clock to Output - PIO — 3.80 Output Register tH_DEL tSUPLL Clock to Data Setup - PIO 0.85 — Input Register tHPLL Clock to Data Hold - PIO 0.98 — Input Register tSU_DELPLL Clock to Data Setup - PIO 1.95 — Input Register with Data Input Delay tH_DELPLL Clock to Data Hold - PIO 0 — Input Register with Data Input Delay General I/O Pin Parameters Using Dedicated Edge Clock Input without PLL Clock to Output - PIO tCO — Output Register Clock to Data Setup - PIO tSU — Input Register Clock to Data Hold - PIO tHD — Input Register Clock to Data Setup - PIO tSU_DEL Input Register with Data — Input Delay Clock to Data Hold - PIO tH_DEL Input Register with Data 0 — Input Delay –7 Unit Min Max Min Max 0 — 0 — ns — 4.67 — 5.51 ns 1.05 — 1.23 — ns 1.21 — 1.42 — ns 2.40 — 2.83 — ns 0 — 0 — ns — 0 0 — — — ns — — ns — — ns — ns — 0 ns 0 General I/O Pin Parameters Using Dedicated Edge Clock Input with PLL Clock to Output - PIO tCOPLL — — — ns Output Register Clock to Data Setup - PIO tSUPLL — — — ns Input Register Clock to Data Hold - PIO tHPLL — — — ns Input Register Clock to Data Setup - PIO tSU_DELPLL — — — ns Input Register with Data Input Delay Clock to Data Hold - PIO tH_DELPLL 0 — 0 — 0 — ns Input Register with Data Input Delay Generic DDR Input/Output Generic DDRX1 Inputs/Outputs with Clock and Data Centered at Pin (GDDRX1_RX/TX.SCLK.Centered) using PCLK Clock Input Figure 3.7 and Figure 3.9 0.550 — 0.550 — 0.648 — ns tSU_GDDR1 Input Data Setup Before CLK 0.275 — 0.275 — 0.275 — UI tHO_GDDR1 Input Data Hold After CLK 0.550 — 0.550 — 0.648 — ns tDVB_GDDR1 Output Data Valid After CLK Output 0.700 –0.300 — — 0.631 –0.369 — — 0.744 –0.435 — — ns ns + 1/2 UI © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 71 CrossLink-NX Family Preliminary Data Sheet Parameter Description tDQVA_GDDR1 Output Data Valid After CLK Output fDATA_GDDRX1 fMAX_GDDRX1 –9 Min 0.700 –0.300 — — — –8 Max — — 500 250 Min 0.631 –0.369 — — –7 Max — — 500.0 250 Min 0.744 –0.435 — — Max — — 424 212 Unit ns ns + 1/2 UI Mbps MHz Input/Output Data Rate Frequency of PCLK Half of Data Bit Time, or 90 ½ UI — 1.000 — 1.179 — ns degree Output TX to Input RX Margin per Edge 0.150 — 0.081 — 0.095 — ns Generic DDRX1 Inputs/Outputs with Clock and Data Aligned at Pin (GDDRX1_RX/TX.SCLK.Aligned) using PCLK Clock Input Figure 3.8 and Figure 3.10 — -0.550 — –0.550 — -0.648 ns + 1/2 UI tDVA_GDDR1 Input Data Valid After CLK — 0.450 — 0.450 — 0.530 ns — 0.225 — 0.225 — 0.225 UI 0.550 — 0.550 — 0.648 — ns + 1/2 UI tDVE_GDDR1 Input Data Hold After CLK 1.550 — 1.550 — 1.827 — ns 0.775 — 0.775 — 0.775 — UI Output Data Invalid After tDIA_GDDR1 — 0.300 — 0.369 — 0.435 ns CLK Output Output Data Invalid Before tDIB_GDDR1 — 0.300 — 0.369 — 0.435 ns CLK Output fDATA_GDDRX1 Input/Output Data Rate — 500 — 500 — 424 Mbps fMAX_GDDRX1 Frequency for PCLK — 250 — 250 — 212 MHz Half of Data Bit Time, or 90 ½ UI 1.000 — 1.000 — 1.179 — ns degree Output TX to Input RX Margin per Edge 0.150 — 0.081 — 0.095 — ns Generic DDRX2 Inputs/Outputs with Clock and Data Centered at Pin (GDDRX2_RX/TX.ECLK.Centered) using PCLK Clock Input Figure 3.7 and Figure 3.9 0.150 — 0.150 — 0.177 — ns tSU_GDDRX2 Data Setup before CLK Input 0.150 — 0.150 — 0.150 — UI tHO_GDDRX2 Data Hold after CLK Input 0.150 — 0.150 — 0.177 — ns 0.380 — 0.352 — 0.415 — ns Output Data Valid Before tDVB_GDDRX2 CLK Output -0.120 — –0.148 — –0.174 — ns + 1/2 UI 0.380 — 0.352 — 0.415 — ns Output Data Valid After CLK tDQVA_GDDRX2 Output -0.120 — –0.148 — –0.174 — ns + 1/2 UI fDATA_GDDRX2 Input/Output Data Rate — 1000 — 1000 — 848 Mbps fMAX_GDDRX2 Frequency for ECLK — 500 — 500 — 424 MHz Half of Data Bit Time, or 90 ½ UI 0.500 — 0.500 — 0.589 — ns degree fPCLK PCLK frequency — 250.0 — 250.0 — 212.1 MHz Output TX to Input RX Margin per Edge 0.230 — 0.202 — 0.239 — ns Generic DDRX2 Inputs/Outputs with Clock and Data Aligned at Pin (GDDRX2_RX/TX.ECLK.Aligned) using PCLK Clock Input Figure 3.8 and Figure 3.10 — –0.275 — -0.275 — –0.324 ns + 1/2 UI tDVA_GDDRX2 Input Data Valid After CLK — 0.225 — 0.225 — 0.265 ns — 0.225 — 0.225 — 0.225 UI 0.275 — 0.275 — 0.324 — ns + 1/2 UI tDVE_GDDRX2 Input Data Hold After CLK 0.775 — 0.775 — 0.914 — ns 0.775 — 0.775 — 0.775 — UI Output Data Invalid After tDIA_GDDRX2 — 0.120 — 0.148 — 0.174 ns CLK Output © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 72 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Parameter Description tDIB_GDDRX2 Output Data Invalid Before CLK Output –9 –8 –7 Min Max Min Max Min Max — 0.120 — 0.148 — 0.174 Unit ns fDATA_GDDRX2 fMAX_GDDRX2 Input/Output Data Rate — 1000 — 1000 — 848 Mbps Frequency for ECLK — 500 — 500 — 424 MHz Half of Data Bit Time, or 90 ½ UI 0.500 — 0.500 — 0.589 — ns degree fPCLK PCLK frequency — 250.0 — 250.0 — 212.1 MHz Output TX to Input RX Margin per Edge 0.105 — 0.077 — 0.091 — ns Generic DDRX4 Inputs/Outputs with Clock and Data Centered at Pin (GDDRX4_RX/TX.ECLK.Centered) using PCLK Clock Input Figure 3.7 and Figure 3.9 (for csfBGA Package Only) tSU_GDDRX4 Input Data Set-Up Before CLK tHO_GDDRX4 Input Data Hold After CLK tDVB_GDDRX4 Output Data Valid Before CLK Output tDQVA_GDDRX4 Input/Output Data Rate fDATA_GDDRX4 fMAX_GDDRX4 Frequency for ECLK PCLK frequency Half of Data Bit Time, or 90 ½ UI degree Input Data Set-Up Before fPCLK CLK Output TX to Input RX Margin per Edge 0.133 0.200 0.133 0.213 -0.120 0.213 -0.120 — — — — — — — — — 1500 750.0 0.167 0.200 0.167 0.269 –0.148 0.269 –0.148 — — — — — — — — — 1200 600 0.193 0.200 0.193 0.309 –0.174 0.309 –0.174 — — — — — — — — — 1034 517 ns UI ns Mbps MHz 0.333 — 0.417 — 0.483 — ns — 187.5 — 150.0 — 129.3 MHz 0.080 — 0.102 — 0.116 — ns Generic DDRX4 Inputs/Outputs with Clock and Data Aligned at Pin (GDDRX4_RX/TX.ECLK.Aligned) using PCLK Clock Input, Left and Right sides Only - Figure 3.8 and Figure 3.10 (for csfBGA Package Only) — –0.183 — –0.229 — –0.266 ns + 1/2 UI tDVA_GDDRX4 Input Data Valid After CLK — 0.150 — 0.188 — 0.218 ns — 0.225 — 0.225 — 0.225 UI 0.183 — 0.229 — 0.266 — ns + 1/2 UI tDVE_GDDRX4 Input Data Hold After CLK 0.517 — 0.646 — 0.749 — ns 0.775 — 0.775 — 0.775 — UI Output Data Invalid After — — — tDIA_GDDRX4 0.120 0.148 0.17 ns CLK Output Output Data Invalid Before — — — tDIB_GDDRX4 0.120 0.148 0.174 ns CLK Output fDATA_GDDRX4 Input/Output Data Rate — 1500 — 1200 — 1034 Mbps fMAX_GDDRX4 Frequency for ECLK — 750 — 600 — 517 MHz Half of Data Bit Time, or 90 ½ UI 0.333 — 0.417 — 0.483 — ns degree fPCLK PCLK frequency — 187.5 — 150.0 — 129.3 MHz Output TX to Input RX Margin per Edge 0.030 — 0.040 — 0.044 — ns Generic DDRX5 Inputs/Outputs with Clock and Data Centered at Pin (GDDRX5_RX/TX.ECLK.Centered) using PCLK Clock Input Figure 3.7 and Figure 3.9 (for csfBGA Package Only) 0.160 — 0.167 — 0.200 — ns Input Data Set-Up Before tSU_GDDRX5 CLK 0.200 — 0.200 — 0.200 — UI tHO_GDDRX5 tWINDOW_GDDRX5C Input Data Hold After CLK Input Data Valid Window 0.160 0.320 — — 0.167 0.333 — — 0.200 0.400 — — ns ns © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 73 CrossLink-NX Family Preliminary Data Sheet Parameter Description tDVB_GDDRX5 Output Data Valid Before CLK Output tDQVA_GDDRX5 Output Data Valid After CLK Output fDATA_GDDRX5 fMAX_GDDRX5 –9 Min 0.280 –0.120 0.280 –0.120 — — –8 Max — — — — 1250 625 Min 0.269 –0.148 0.269 –0.148 — — –7 Max — — — — 1200 600 Min 0.326 –0.174 0.326 –0.174 — — Max — — — — 1000 500 Unit ns ns+1/2UI ns ns+1/2UI Mbps MHz Input/Output Data Rate Frequency for ECLK Half of Data Bit Time, or 90 ½ UI 0.400 — 0.417 — 0.500 — ns degree fPCLK PCLK frequency — 125.0 — 120.0 — 100.0 MHz Output TX to Input RX Margin per Edge 0.120 — 0.102 — 0.126 — ns Generic DDRX5 Inputs/Outputs with Clock and Data Aligned at Pin (GDDRX5_RX/TX.ECLK.Aligned) using PCLK Clock Input Figure 3.8 and Figure 3.10 (for csfBGA Package Only) — –0.220 — –0.229 — –0.275 ns + 1/2 UI tDVA_GDDRX5 Input Data Valid After CLK — 0.180 — 0.188 — 0.225 ns — 0.225 — 0.225 — 0.225 UI 0.220 — 0.229 — 0.275 — ns + 1/2 UI tDVE_GDDRX5 Input Data Hold After CLK 0.620 — 0.646 — 0.775 — ns 0.775 — 0.775 — 0.775 — UI tWINDOW_GDDRX5A Input Data Valid Window 0.440 — 0.458 — 0.550 — ns Output Data Invalid After tDIA_GDDRX5 — 0.120 — 0.148 — 0.174 ns CLK Output Output Data Invalid Before tDIB_GDDRX5 — 0.120 — 0.148 — 0.174 ns CLK Output fDATA_GDDRX5 Input/Output Data Rate — 1250 — 1200 — 1000 Mbps fMAX_GDDRX5 Frequency for ECLK — 625 — 600 — 500 MHz Half of Data Bit Time, or 90 ½ UI 0.400 — 0.417 — 0.500 — ns degree fPCLK PCLK frequency — 125.0 — 120.0 — 100.0 MHz Output TX to Input RX Margin per Edge 0.060 — 0.040 — 0.051 — ns Soft D-PHY DDRX4 Inputs/Outputs with Clock and Data Centered at Pin, using PCLK Clock Input (for csfBGA Package Only) 0.133 — 0.167 — 0.193 — ns Input Data Set-Up Before tSU_GDDRX4_MP CLK 0.200 — 0.200 — 0.200 — UI tHO_GDDRX4_MP Input Data Hold After CLK 0.133 — 0.167 — 0.193 — ns 0.133 — 0.167 — 0.193 — ns Output Data Valid Before tDVB_GDDRX4_MP 0.200 — 0.200 — 0.200 — UI CLK Output –0.133 — –0.167 — –0.193 — ns + 1/2 UI 0.200 — 0.250 — 0.290 — ns Output Data Valid After CLK tDQVA_GDDRX4_MP Output –0.133 — –0.167 — 0.193 — ns + 1/2 UI Input Data Bit Rate for MIPI fDATA_GDDRX4_MP — 1500 — 1200 — 1034 Mbps PHY Half of Data Bit Time, or 90 ½ UI 0.333 — 0.417 — 0.483 — ns degree fPCLK PCLK frequency — 187.5 — 150.0 — 129.3 MHz Output TX to Input RX Margin per Edge 0.067 0.083 0.097 ns Video DDRX71 Inputs/Outputs with Clock and Data Aligned at Pin (GDDRX71_RX.ECLK) using PLL Clock Input - Figure 3.12 and Figure 3.13 Input Valid Bit "i" switch — 0.300 — 0.300 — 0.300 UI tRPBi_DVA from CLK Rising Edge ("i" = 0 — — — –0.212 –0.212 –0.249 ns+(1/2+i)*UI to 6, 0 aligns with CLK) © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 74 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Parameter Description –9 –8 ns+(1/2+i)*UI 0.159 — 0.187 ns+i*UI -0.159 — -0.187 — ns+(i+ 1)*UI — 1.058 — — 0.150 — 945 473 — 1.247 — — 0.150 — 802 401 UI ns Mbps MHz fCLKIN 7:1 Clock (PCLK) Frequency — 135.0 — 135.0 Output TX to Input RX Margin per Edge 0.159 — 0.159 — Memory Interface DDR3/DDR3L/LPDDR2/LPDDR3 READ (DQ Input Data are Aligned to DQS) - Figure 3.8 tDVBDQ_DDR3 Data Output Valid before tDVBDQ_DDR3L — –0.258 — DQS Input tDVBDQ_LPDDR2 tDVBDQ_LPDDR3 tDVADQ_DDR3 Data Output Valid after DQS tDVADQ_DDR3L 0.131 — — Input tDVADQ_LPDDR2 tDVADQ_LPDDR3 fDATA_DDR3 fDATA_DDR3L DDR Memory Data Rate — 1066 — fDATA_LPDDR2 fDATA_LPDDR3 fMAX_ECLK_DDR3 DDR Memory ECLK fMAX_ECLK_DDR3L — 533 — Frequency fMAX_ECLK_LPDDR2 fMAX_ECLK_LPDDR3 fMAX_SCLK_DDR3 fMAX_SCLK_DDR3L DDR Memory SCLK — 133.3 — Frequency fMAX_SCLK_LPDDR2 fMAX_SCLK_LPDDR3 — 0.187 114.5 — MHz ns tTPBi_DOV tTPBi_DOI tTPBi_skew_UI tB fDATA_TX71 fMAX_TX71 Min 0.700 Min 0.700 0.212 Max — — 0.212 — 0.159 — -0.159 — — 1.058 — — 0.150 — 945 473 Unit 0.249 Input Hold Bit "i" switch from CLK Rising Edge ("i" = 0 to 6, 0 aligns with CLK) Data Output Valid Bit "i" switch from CLK Rising Edge ("i" = 0 to 6, 0 aligns with CLK) Data Output Invalid Bit "i" switch from CLK Rising Edge ("i" = 0 to 6, 0 aligns with CLK) TX skew in UI Serial Data Bit Time, = 1UI DDR71 Serial Data Rate DDR71 ECLK Frequency Max — — –7 Max — — tRPBi_DVE Min 0.700 DDR3/DDR3L/LPDDR2/LPDDR3 WRITE (DQ Output Data are Centered to DQS) - Figure 3.11 tDQVBS_DDR3 Data Output Valid before tDQVBS_DDR3L — –0.235 — DQS Output tDQVBS_LPDDR2 tDQVBS_LPDDR3 tDQVAS_DDR3 tDQVAS_DDR3L Data Output Valid after DQS 0.235 — — Output tDQVAS_LPDDR2 tDQVAS_LPDDR3 fDATA_DDR3 fDATA_DDR3L fDATA_LPDDR2 fDATA_LPDDR3 DDR Memory Data Rate — 1066 — — UI ns + 1/2 UI — ns + 1/2 UI — Mb/s — MHz — MHz — ns + 1/2 UI — — ns + 1/2 UI Mb/s © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 75 CrossLink-NX Family Preliminary Data Sheet Parameter –9 Description Min –8 Max Min –7 Max Min Max Unit fMAX_ECLK_DDR3 DDR Memory ECLK fMAX_ECLK_DDR3L — 533 — — MHz Frequency fMAX_ECLK_LPDDR2 fMAX_ECLK_LPDDR3 fMAX_SCLK_DDR3 DDR Memory SCLK fMAX_SCLK_DDR3L — 133.3 — — MHz Frequency fMAX_SCLK_LPDDR2 fMAX_SCLK_LPDDR3 Notes: 1. Commercial timing numbers are shown. Industrial numbers are typically slower and can be extracted from the Lattice Radiant software. 2. General I/O timing numbers are based on LVCMOS 2.5, 12 mA, Fast Slew Rate, 0 pf load. Generic DDR timing are numbers based on LVDS I/O. DDR3 timing numbers are based on SSTL15. LPDDR2 and LPDDR3 timing numbers are based on HSUL12. 3. Uses LVDS I/O standard for measurements. 4. Maximum clock frequencies are tested under best case conditions. System performance may vary upon the user environment. 5. All numbers are generated with the Lattice Radiant software. Rx CLK (in) Rx DATA (in) tSU/tDVBDQ tSU/tDVBDQ tHD/tDVADQ tHD/tDVADQ Figure 3.7. Receiver RX.CLK.Centered Waveforms 1/2 UI Rx CLK (in) or DQS Input 1/2 UI 1 UI Rx DATA (in) or DQ Input tSU tSU tHD tHD Figure 3.8. Receiver RX.CLK.Aligned and DDR Memory Input Waveforms © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 76 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 1/2 UI 1/2 UI 1/2 UI 1/2 UI Tx CLK (out) or DQS Output Tx DATA (out) or DQ Output tDVB/tDQVBS tDVB/tDQVBS tDVA/tDQVAS tDVA/tDQVA Figure 3.9. Transmit TX.CLK.Centered and DDR Memory Output Waveforms 1 UI Tx CLK (out) Tx DATA (out) tDIB tDIB tDIA tDIA Figure 3.10. Transmit TX.CLK.Aligned Waveforms © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 77 CrossLink-NX Family Preliminary Data Sheet Receiver – Shown for one LVDS Channel # of Bits Data In 756 Mb/s Clock In 108 MHz Bit # 10 – 1 11 – 2 12 – 3 13 – 4 14 – 5 15 – 6 16 – 7 0x 0x For each Channel: 0x 7-bit Output Words 0x to FPGA Fabric 0x 0x 0x Bit # 20 – 8 21 – 9 22 – 10 23 – 11 24 – 12 25 – 13 26 – 14 Bit # 30 – 15 31 – 16 32 – 17 33 – 18 34 – 19 35 – 20 36 – 21 Bit # 40 – 22 41 – 23 42 – 24 43 – 25 44 – 26 45 – 27 46 – 28 Transmitter – Shown for one LVDS Channel # of Bits Data Out 756 Mb/s Clock Out 108 MHz For each Channel: 7-bit Output Words to FPGA Fabric Bit # 00 – 1 00 – 2 00 – 3 00 – 4 00 – 5 00 – 6 00 – 7 Bit # 10 – 8 11 – 9 12 – 10 13 – 11 14 – 12 15 – 13 16 – 14 Bit # 20 – 15 21 – 16 22 – 17 23 – 18 24 – 19 25 – 20 26 – 21 Bit # 30 – 22 31 – 23 32 – 24 33 – 25 34 – 26 35 – 27 36 – 28 Figure 3.11. DDRX71 Video Timing Waveforms Bit 0 1/2 UI CLK (in) Bit i 1/2 UI Bit 1 1 UI DATA (in) tSU_0 tHD_0 tSU_i tHD_i Figure 3.12. Receiver DDRX71_RX Waveforms © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 78 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Bit 0 Bit i Bit 1 1 UI CLK (out) DATA (out) tDIB_0 tDIA_0 tDIB_i tDIA_i Figure 3.13. Transmitter DDRX71_TX Waveforms 3.17. CrossLink-NX sysCLOCK PLL Timing (VCC = 1.0 V) Over recommended operating conditions. Table 3.30. sysCLOCK PLL Timing (VCC = 1.0 V) Parameter Descriptions Conditions Min Typ. Max Units fIN Input Clock Frequency (CLKI, CLKFB) — 10 — 500 MHz fOUT Output Clock Frequency — 6.25 — 800 MHz fVCO PLL VCO Frequency — 800 — 1600 MHz 10 — 500 MHz 10 — 100 MHz — 0.25 — % 45 — 55 % — –5 — 5 % fOUT ≥ 100 MHz — — 100 ps p-p fOUT < 100 MHz — — 0.025 UIPP fOUT ≥ 100 MHz — — 200 ps p-p fOUT < 100 MHz — — 0.05 UIPP fPFD ≥ 100 MHz — — 200 ps p-p fPFD < 100 MHz — — 0.05 UIPP Divider ratio = integer — — 400 ps p-p fPFD ≥ 20 MHz — — MHz fPFD 3 Phase Detector Input Frequency Spread Spectrum Clock Modulation Frequency AC CharacteristicsStep fSSC_MOD_STEP tDT Output Clock Duty Cycle tPH4 Output Phase Accuracy Output Clock Period Jitter tOPJIT1 Output Clock Cycle-to-Cycle Jitter Output Clock Phase Jitter Without SSC or Fractional-N Enabled With SSC or Fractional-N Enabled — tSPO Static Phase Offset fBW PLL Loop Bandwidth fPFD < 20 MHz — — MHz tLOCK2 PLL Lock-in Time — — — 10 ms tUNLOCK PLL Unlock Time (from RESET goes HIGH) — — — 50 ns © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 79 CrossLink-NX Family Preliminary Data Sheet Parameter Descriptions Conditions Min Typ. Max Units tIPJIT Input Clock Period Jitter fPFD ≥ 20 MHz — fPFD < 20 MHz — — 500 ps p-p — 0.01 UIPP tHI tLO Input Clock High Time 90% to 90% Input Clock Low Time 10% to 10% 0.5 — — ns 0.5 — — ns tRST RST/ Pulse Width tRSTREC RST Recovery Time — 1 — — ms — 1 — — ns fSSC_MOD Spread Spectrum Clock Modulation Frequency — 20 — 200 KHz fSSC_MOD_STEP Spread Spectrum Clock Modulation Amplitude Step Size — — 0.25 — % Notes: 1. Jitter sample is taken over 10,000 samples for Period jitter, and 1,000 samples for Cycle-to-Cycle jitter of the primary PLL output with clean reference clock with no additional I/O toggling. 2. Output clock is valid after tLOCK for PLL reset and dynamic delay adjustment. 3. Period jitter and cycle-to-cycle jitter numbers are guaranteed for fPFD > 10 MHz. For fPFD < 10 MHz, the jitter numbers may not be met in certain conditions. 3.18. CrossLink-NX Internal Oscillators Characteristics Table 3.31. Internal Oscillators (VCC = 1.0 V) Symbol Parameter Description Min Typ Max Unit fCLKHF HFOSC CLKK Clock Frequency 405 450 495 MHz fCLKLF LFOSC CLKK Clock Frequency 25.6 32 38.4 kHz DCHCLKHF HFOSC Duty Cycle (Clock High Period) 45 50 55 % DCHCLKLF LFOSC Duty Cycle (Clock High Period) 45 50 55 % 3.19. CrossLink-NX User I2C Characteristics Table 3.32. User I2C Specifications (VCC = 1.0 V) Symbol Parameter Description fscl TDELAY STD Mode FAST Mode Plus2 FAST Mode Units Min Typ Max Min Typ Max Min Typ Max SCL Clock Frequency — — 100 — — 400 — — 1000 kHz Optional delay through delay block — 62 — — 62 — — 62 — ns Notes: 1. Refer to the I2C Specification for timing requirements. User design should set constraints in Lattice Design Software to meet this industrial I2C Specification. 2. Fast Mode Plus maximum speed may be achieved by using external pull up resistor on I2C bus. Internal pull up may not be sufficient to support the maximum speed. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 80 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 3.20. CrossLink-NX Analog-Digital Converter (ADC) Block Characteristics Table 3.33. ADC Specifications Symbol VREFINT_ADC VREFEXT_ADC NRES_ADC ENOBADC Description Condition ADC Internal Reference Voltage ADC External Reference Voltage ADC Resolution Effective Number of Bits — — — — Bipolar Mode, Internal VREF Bipolar Mode, External VREF VSR_ADC VCM_ADC fCLK_ADC DCCLK_ADC fINPUT_ADC FSADC NTRACK_ADC ADC Input Range ADC Input Common Mode Voltage (for fully differential signals) ADC Clock Frequency ADC Clock Duty Cycle ADC Input Frequency ADC Sampling Rate ADC Input Tracking Time Uni-polar Mode, Internal VREF Uni-polar Mode, External VREF Internal VREF Min Typ Max Unit — 1.2 — V 1.0 — 1.8 V — — 12 10.8 — — bits bits VCM_ADC ― VREFINT_ADC/4 VCM_ADC ― VREFEXT_ADC/4 VCM_ADC VREFEXT_ADC VCM_ADC + VREFINT_ADC/4 VCM_ADC + VREFEXT_ADC/4 — VREFINT_ADC V 0 — VREFEXT_ADC V — VREFINT_ADC/2 — V External VREF — VREFEXT_ADC/2 — V — — — — — 1 48 — — 2 25 50 — 1 — 40 52 500 — — MHz % kHz MS/s cycles — 116 — KΩ — 25 — — 6500 — cycles cycles — –0.9 — 0.9 LSB — –1.5 — 1.5 LSB — 74 77 — dBc — — –76 –73 dB — 65.7 67.5 — dB dB 1 MS/s, Sampled @ 2 clock cycles — — — 65 67 — ERRGAIN_ADC ADC Gain Error — — 0.5 1.0 ERROFFSET_ADC ADC Offset Error — — 0.5 1.0 CIN_ADC ADC Input Equivalent Capacitance — — 2 — tCAL_ADC LOUTput_ADC DNLADC INLADC SFDRADC THDADC SNRADC SNDRADC V 0 ADC Input Equivalent Resistance ADC Calibration Time ADC Conversion Time ADC Differential Nonlinearity ADC Integral Nonlinearity ADC Spurious Free Dynamic Range ADC Total Harmonic Distortion ADC Signal to Noise Ratio ADC Signal to Noise Plus Distortion Ratio RIN_ADC V % FSADC % FSADC pF © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 81 CrossLink-NX Family Preliminary Data Sheet 3.21. CrossLink-NX Comparator Block Characteristics Table 3.34. Comparator Specifications Symbol Description Min Typ Max Unit fIN_COMP Comparator Input Frequency — — 10 MHz VIN_COMP Comparator Input Voltage 0 — VCCADC18 V VOFFSET_COMP Comparator Input Offset –10 — 10 mV VHYST_COMP Comparator Input Hysteresis — — 35 mV VLATENCY_COMP Comparator Latency — — 30 ns 3.22. CrossLink-NX Digital Temperature Readout Characteristics Digital temperature Readout (DTR) is implemented in one of the internal Analog-Digital-Converter (ADC) channel. Table 3.35. DTR Specifications Symbol DTRRANGE Description DTR Detect Temperature Range DTRACCURACY DTR Accuracy DTRRESOLUTION DTR Resolution Condition — with external voltage reference with external voltage reference Min –40 Typ — Max 125 –2 — 2 –0.3 — 0.3 Unit °C °C °C 3.23. CrossLink-NX Hardened MIPI D-PHY Characteristics Table 3.36. Hardened D-PHY Input Timing and Levels Symbol Description Conditions Min Typ Max Unit — 70 — 330 mV 0.08 Gbps ≤ VIDTH ≤ 1.5 Gbps 70 — — mV 1.5 Gbps < VIDTH ≤ 2.5 Gbps 40 — — mV 0.08 Gbps ≤ VIDTL ≤ 1.5 Gbps — — –70 mV High Speed (Differential) Input DC Specifications VCMRX(DC) Common-mode Voltage in High Speed Mode VIDTH Differential Input HIGH Threshold VIDTL Differential Input LOW Threshold 1.5 Gbps < VIDTL ≤ 2.5 Gbps — — –40 mV VIHHS Input HIGH Voltage (for HS mode) — — — 460 mV VILHS Input LOW Voltage — –40 — — mV VTERM-EN Single-ended voltage for HS Termination Eanble4 — — — 450 mV ZID Differential Input Impedance — 80 100 125 Ω 0.08 Gbps ≤ ∆VCMRX(HF) ≤ 1.5 Gbps — — 100 mV 1.5 Gbps < ∆VCMRX(HF) ≤ 2.5 Gbps — — 50 mV 0.08 Gbps ≤ ∆VCMRX(LF) ≤ 1.5 Gbps –50 — 50 mV 1.5 Gbps < ∆VCMRX(LF) ≤ 2.5 Gbps –25 — 25 mV 60 pF High Speed (Differential) Input AC Specifications ΔVCMRX(HF)1 ΔVCMRX(LF)2, 3 CCM Common-mode Interference (>450 MHz) Common-mode Interference (50 MHz - 450 MHz) Common-mode Termination — © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 82 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Symbol Description Conditions Min Typ Max Unit Low Power (Single-Ended) Input DC Specifications VIH Low Power Mode Input HIGH Voltage — 740 — — mV VIL Low Power Mode Input LOW Voltage — — — 550 mV VIL-ULP Ultra Low Power Input LOW Voltage — — — 300 mV VHYST Low Power Mode Input Hysteresis — 25 — — mV ℮SPIKE Input Pulse Rejection — — — 300 V∙ps TMIN-RX Minimum Pulse Width Response — 20 — — ns VINT Peak Interference Amplitude — — — 200 mV fINT Interference Frequency — 450 — — MHz Contention Detector (LP-CD) DC Specifications VIHCD Contention Detect HIGH Voltage — 450 — — mV VILCD Contention Detect LOW Voltage — — — 200 mV Notes: 1. This is peak amplitude of sine wave modulated to the receiver inputs. 2. Input common-mode voltage difference compared to average common-mode voltage on the receiver inputs. 3. Exclude any static ground shift of 50 mV. 4. High Speed Differential RTERM is enabled when both DP and DN are below this voltage. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 83 CrossLink-NX Family Preliminary Data Sheet Table 3.37. Hardened D-PHY Output Timing and Levels Symbol Description High Speed (Differential) Output DC Specifications VCMTX Common-mode Voltage in High Speed Mode Conditions Min Typ Max Unit — 150 200 250 mV |ΔVCMTX(1,0)| VCMTX Mismatch Between Differential HIGH and LOW — — — 5 mV |VOD| Output Differential Voltage |D-PHY-P – D-PHYN| 140 200 270 mV — — — 14 mV — — — — 40 — — 50 — 360 62.5 20 mV Ω % — — 0.08 Gbps ≤ tR ≤ 1 Gbps 1 Gbps < tR ≤ 1.5 Gbps tR ≤ 1.5 Gbps 1.5 Gbps < tR ≤ 2.5 Gbps tR > 1.5 Gbps 0.08 Gbps ≤ tF ≤ 1 Gbps — — — — 25 15 mVRMS mVRMS — — 0.30 UI — — 0.35 UI 100 — — ps — — 0.40 UI 50 — — ps — — 0.30 UI — — 0.35 UI 100 — — ps — — 0.40 UI 50 — — ps 1.1 1.2 1.3 V 0.95 –50 110 — — — 1.3 50 — V mV Ω — — — — — — 25 25 35 ns ns ns 40 — — ns VOD Mismatch Between Differential HIGH and LOW VOHHS Single-Ended Output HIGH Voltage ZOS Single Ended Output Impedance ΔZOS ZOS mismatch High Speed (Differential) Output AC Specifications ΔVCMTX(LF) Common-Mode Variation, 50 MHz – 450 MHz ΔVCMTX(HF) Common-Mode Variation, above 450 MHz |ΔVOD| Output 20% - 80% Rise Time Output 80% - 20% Fall Time tR tF Output Data Valid After CLK Output 1 Gbps < tF ≤ 1.5 Gbps tF ≤ 1.5 Gbps 1.5 Gbps < tF ≤ 2.5 Gbps tF > 1.5 Gbps Low Power (Single-Ended) Output DC Specifications VOH Low Power Mode Output HIGH Voltage VOL Low Power Mode Input LOW Voltage ZOLP Output Impedance in Low Power Mode Low Power (Single-Ended) Output AC Specifications tRLP 15% - 85% Rise Time tFLP 85% - 15% Fise Time tREOT HS – LP Mode Rise and Fall Time, 30% - 85% 0.08 Gbps ≤ VOH ≤ 1.50 Gbps VOH > 1.50 Gbps — — — — — 1st LP XOR Clock Pulse after STOP State or Last Pulse before STOP State TLP-PULSE-TX Pulse Width of the LP Exclusive-OR Clock TLP-PER-TX Period of the LP Exclusive-OR Clock All Other Pulses — 20 90 — — — — ns ns δV/δtSR Slew Rate @ CLOAD = 0 pF Slew Rate @ CLOAD = 5 pF Slew Rate @ CLOAD = 20 pF — — — — — — — — — 500 300 250 mV/ns mV/ns mV/ns © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 84 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Symbol Description Slew Rate @ CLOAD = 70 pF Slew Rate @ CLOAD = 0 to 70 pF (Falling Edge Only) Slew Rate @ CLOAD = 0 to 70 pF (Rising Edge Only) Conditions — — — — — Min — 30 25 30 25 30 0.075* (VO,INST 700) 25 0.0625* (VO,INST 550) 0 Typ — — — — — Max 150 — — — — Unit mV/ns mV/ns mV/ns mV/ns mV/ns — — mV/ns — — mV/ns — 70 pF Min Typ Max Unit — — — — — — –50 –50 –100 –50 –5 –0.15 — — — — — — 1350 1150 100 50 5 1.45 mV mV µA mV mV V — — — 20 ns Min Typ Max Unit — — — 12.5 ns — — –10% –5% — — 10% 5% UI UI — Slew Rate @ CLOAD = 0 to 70 pF (Rising Edge Only) — CLOAD Load Capacitance — Table 3.38. Hardened D-PHY Pin Characteristic Specifications Symbol Description Pin Characteristic Specifications VPIN Pin Signal Voltage Range VPIN_LVLP Pin Signal Voltage Range in LVLP Operation ILEAK Pin Leakage Current VGNDSH Ground Shift VPIN(absmax) Transient Pin Voltage Level TVPIN(absmax) Maximum Transient Time above VPIN(max) or below VPIN(min) Conditions Table 3.39. Hardened D-PHY Clock Signal Specification Symbol Description Clock Signal Specification UI UIINST Instantaneous UI Variation ∆UI Conditions © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 85 CrossLink-NX Family Preliminary Data Sheet Table 3.40. Hardened D-PHY Data-Clock Timing Specifications Symbol Description Data-Clock Timing Specifications TSKEW[TX] TSKEW[TLIS] TSETUP[RX] THOLD[RX] FIN_DPHY TSKEW[TX] Static TSKEW[TLIS] Static TSKEW[RX] Static TSKEW[TX] Dynamic ISI TSETUP[RX] + THOLD[RX] Dynamic Conditions 0.08 Gbps ≤ TSKEW[TX] ≤ 1.00 Gbps 1.00 Gbps < TSKEW[TX] ≤ 1.50 Gbps 0.08 Gbps ≤ TSKEW[TLIS] ≤ 1.00 Gbps 1.00 Gbps < TSKEW[TLIS] ≤ 1.50 Gbps Data to Clock Skew Data to Clock Skew Min Typ Max Unit –0.15 — 0.15 UIINST –0.20 — 0.20 UIINST –0.20 — 0.20 UIINST –0.10 — 0.10 UIINST 0.15 — — UI 0.20 — — UI 0.15 — — UI 0.20 — — UI 0.08 Gbps ≤ TSETUP[RX] ≤ 1.00 Gbps 1.00 Gbps < TSETUP[RX] ≤ 1.50 Gbps 0.08 Gbps ≤ THOLD[RX] ≤ 1.00 Gbps 1.00 Gbps < THOLD[RX] ≤ 1.50 Gbps Input Data Setup Before CLK Input Data Hold After CLK Input frequency to Hardened D-PHY PLL Static Data to Clock Skew (Tx) Static Data to Clock Skew (Channel) Static Data to Clock Skew (Rx) > 1.5 Gbps > 1.5 Gbps > 1.5 Gbps 24 –0.20 –0.10 –0.20 — — — 200 0.20 0.10 0.20 MHz UIINST UIINST UIINST Dynamic Data to Clock Skew (Tx) > 1.5 Gbps –0.15 — 0.15 UIINST Channel ISI > 1.5 Gbps — — 0.20 UIINST Dynamic Data to Clock Skew Window Rx Tolerance > 1.5 Gbps 0.50 — — UIINST 3.24. CrossLink-NX Hardened PCIe Characteristics 3.24.1. PCIe (2.5 Gb/s) Over recommended operating conditions. Table 3.41. PCIe (2.5 Gb/s) Symbol Transmitter1 UI BWTX VTX-DIFF-PP VTX-DIFF-PP-LOW VTX-DE-RATIO-3.5dB TTX-RISE-FALL TTX-EYE Description Condition Min. Unit Interval Tx PLL bandwidth Differential p-p Tx voltage swing Low power differential p-p Tx voltage swing Tx de-emphasis level ratio at 3.5dB Transmitter rise and fall time — — 399.88 1.5 400 — 400.12 22 ps MHz — 0.8 — 1.2 Vp-p — 0.4 — 1.2 Vp-p — 3 — 4 dB — 0.125 — — UI — 0.75 — — UI Transmitter Eye, including all jitter sources Typ. Max. Unit © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 86 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Symbol TTX-EYE-MEDIAN-to-MAXJITTER RLTX-DIFF RLTX-CM ZTX-DIFF-DC VTX-CM-AC-P ITX-SHORT VTX-DC-CM VTX-IDLE-DIFF-AC-p VTX-RCV-DETECT TTX-IDLE-MIN TTX-IDLE-SET-TO-IDLE TTX-IDLE-TO-DIFF-DATA Receiver2 UI VRX-DIFF-PP TRX-EYE3 TRX-EYE-MEDIAN-to-MAX3 JITTER RLRX-DIFF RLRX-CM ZRX-DC ZRX-DIFF-DC ZRX-HIGH-IMP-DC VRX-CM-AC-P3 Description Max. time between jitter median and max deviation from the median Condition Tx Differential Return Loss, including pkg and silicon Tx Common Mode Return Loss, including pkg and silicon DC differential Impedance Tx AC peak common mode voltage, RMS Transmitter short-circuit current Transmitter DC common-mode voltage Electrical Idle Output peak voltage — Voltage change allowed during Receiver Detect Min. time in Electrical Idle Max. time from EI Order Set to valid Electrical Idle Max. time from Electrical Idle to valid differential output Unit Interval Differential Rx peak-peak voltage Receiver eye opening time Max time delta between median and deviation from median Receiver differential Return Loss, package plus silicon Receiver common mode Return Loss, package plus silicon Receiver DC single ended impedance Receiver DC differential impedance Receiver DC single ended impedance when powered down Rx AC peak common mode voltage Electrical Idle Detect Threshold — Min. Typ. Max. Unit — — 0.125 UI 10 — — dB 50 MHz < freq < 2.5 GHz 6 — — dB — 80 — 120 — — — 20 Ω mV, RMS — — — 90 mA — 0 — 1.2 V — — — 20 mV — — — 600 mV — 20 — — ns — — — 8 ns — — — 8 ns — 399.88 400 400.12 ps — 0.175 — 1.2 Vp-p — 0.4 — — UI — — — 0.3 UI — 10 — — dB — 6 — — dB — 40 — 60 Ω — 80 — 120 Ω — 200K — — Ω — 150 — mV, peak mVp-p VRX-IDLE-DET-DIFF-PP — 65 — 175 Notes: 1. Refer to PCI Express Base Specification Revision 3.0 Table 4.18 test condition and requirement for respective parameters. 2. Refer to PCI Express Base Specification Revision 3.0 Table 4.24 test condition and requirement for respective parameters. 3. Spec compliant requirement © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 87 CrossLink-NX Family Preliminary Data Sheet 3.24.2. PCIe (5 Gb/s) Over recommended operating conditions. Table 3.42. PCIe (5 Gb/s) Symbol Transmit1 UI Description Test Conditions Unit Interval Tx PLL bandwidth corresponding to PKGTX-PLL1 Tx PLL bandwidth corresponding to PKGTX-PLL2 Tx PLL Peaking corresponding to PKGTX-PLL1 Tx PLL Peaking corresponding to PKGTX-PLL2 Differential p-p Tx voltage swing Low power differential p-p Tx voltage swing Tx de-emphasis level ratio at 3.5dB Tx de-emphasis level ratio at 6dB TMIN-PULSE TTX-RISE-FALL BWTX-PKG-PLL1 BWTX-PKG-PLL2 PKGTX-PLL1 PKGTX-PLL2 VTX-DIFF-PP VTX-DIFF-PP-LOW VTX-DE-RATIO-3.5dB VTX-DE-RATIO-6dB TTX-EYE TTX-DJ Min Typ Max Unit — 199.94 200 200.06 ps — 8 — 16 MHz — 5 — 16 MHz — — — 3 dB — — — 1 dB — 0.8 — 1.2 V, p-p — 0.4 — 1.2 V, p-p — 3 — 4 dB — 5.5 — 6.5 dB Instantaneous lone pulse width — 0.9 — — UI Transmitter rise and fall time — 0.15 — — UI — 0.75 — — UI — — — 0.15 UI Transmitter Eye, including all jitter sources Tx deterministic jitter > 1.5 MHz TTX-RJ Tx RMS jitter < 1.5 MHz — — — 3 ps, RMS TRF-MISMATCH Tx rise/fall time mismatch — — — 0.1 UI RLTX-DIFF Tx Differential Return Loss, including package and silicon 50 MHz < freq < 1.25 GHz 1.25 GHz < freq < 2.5 GHz 10 8 — — — — dB dB RLTX-CM Tx Common Mode Return Loss, including package and silicon 50 MHz < freq < 2.5 GHz 6 — — dB ZTX-DIFF-DC DC differential Impedance — — — 120 Ω VTX-CM-AC-PP Tx AC peak common mode voltage, peak-peak — — — 150 mV, p-p — — — 90 mA — 0 — 1.2 V — 0 — 5 mV — — — 20 mV — — — 600 mV VTX-RCV-DETECT Transmitter short-circuit current Transmitter DC common-mode voltage Electrical Idle Output DC voltage Electrical Idle Differential Output peak voltage Voltage change allowed during Receiver Detect TTX-IDLE-MIN Min. time in Electrical Idle — 20 — — ns TTX-IDLE-SET-TO-IDLE Max. time from EI Order Set to valid Electrical Idle — — — 8 ns ITX-SHORT VTX-DC-CM VTX-IDLE-DIFF-DC VTX-IDLE-DIFF-AC-p © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 88 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Symbol TTX-IDLE-TO-DIFF-DATA Description Max. time from Electrical Idle to valid differential output Test Conditions Min Typ Max Unit — — — 8 ns Unit Interval Differential Rx peak-peak voltage Receiver random jitter tolerance (RMS) Receiver deterministic jitter tolerance — 199.94 200 200.06 ps — 0.343 — 1.2 V, p-p 1.5 MHz – 100 MHz Random noise — — 4.2 ps, RMS — — — 88 ps Receiver differential Return Loss, package plus silicon 50 MHz < freq < 1.25 GHz 1.25 GHz < freq < 2.5 GHz 10 8 — — — — dB dB — 6 — — dB — 40 — 60 Ω — 200K — — Ω — — — 150 Receive2 UI VRX-DIFF-PP TRX-RJ-RMS TRX-DJ RLRX-DIFF Receiver common mode Return Loss, package plus silicon Receiver DC single ended impedance RLRX-CM ZRX-DC Receiver DC single ended impedance when powered down ZRX-HIGH-IMP-DC Rx AC peak common mode voltage Electrical Idle Detect Threshold VRX-CM-AC-P3 mV, peak mv, pp VRX-IDLE-DET-DIFF-PP — 65 — 3403 Notes: 1. Refer to PCI Express Base Specification Revision 3.0 Table 4.18 test condition and requirement for respective parameters. 2. Refer to PCI Express Base Specification Revision 3.0 Table 4.24 test condition and requirement for respective parameters. 3. Spec compliant requirement 3.25. CrossLink-NX Hardened SGMII Receiver Characteristics 3.25.1. SGMII Rx Specifications Over recommended operating conditions. Table 3.43. SGMII Rx Symbol Description Test Conditions fDATA SGMII Data Rate SGMII Reference Clock Frequency (Data Rate / 10) Jitter Tolerance, Deterministic — Jitter Tolerance, Total Data Rate and Reference Clock Accuracy — — fREFCLK JTOL_DET JTOL_TOL Δf/f Min Typ Max Unit — — 1250 — MHz — — 125 — MHz — — UI — — — 300 UI ppm –300 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 89 CrossLink-NX Family Preliminary Data Sheet 3.26. CrossLink-NX sysCONFIG Port Timing Specifications Over recommended operating conditions. Table 3.44. CrossLink-NX sysCONFIG Port Timing Specifications Symbol Parameter Device Min Typ. Max Unit — — — ms — — — µs — — fCLKHF/128 — — — Master SPI POR / REFRESH Timing Time during POR, from VCC, VCCAUX, VCCIO0 or VCCIO1 (whichever is the last) pass POR trip voltage, or REFRESH command executed, to the rising edge of INITN tICFG Time from rising edge of INITN to the valid Master MCLK Default MCLK frequency (Before MCLK fMCLK_DEF frequency selection in bitstream) Slave SPI/I2C/I3C POR / REFRESH Timing tVMC Time during POR, from VCC, VCCAUX, VCCIO0 or VCCIO1 (whichever is the last) pass POR trip tMSPI_INH voltage, or REFRESH command executed, to pull PROGRAMN LOW to prevent entering MSPI mode Minimum time before driving CCLK (SSPI) from tACT_CCLK POR or REFRESH Minimum time before driving SCL (I2C/I3C) tACT_SCL from POR or REFRESH Minimum time driving PROGRAMN HIGH after tACT_PROGRAMN_H last activation clock Minimum time to start driving CCLK (SSPI) after tCONFIG_CCLK PROGRAMN HIGH Minimum time to start driving SCL (I2C/I3C) tCONFIG_CCLK after PROGRAMN HIGH PROGRAMN Configuration Timing — MHz µs — — — µs — — — µs — — — ns — — — ns — — — ns — — ns tPROGRAMN PROGRAMN LOW pulse accepted — tPROGRAMN_RJ PROGRAMN LOW pulse rejected — — — tINIT_LOW PROGRAMN LOW to INITN LOW — — — LIFCL-40 — ns ns — ns — ns tINIT_HIGH PROGRAMN LOW to INITN HIGH LIFCL-17 — tDONE_LOW PROGRAMN LOW to DONE LOW — — tDONE_HIGH PROGRAMN HIGH to DONE HIGH — tIODISS PROGRAMN LOW to I/O Disabled — — — fMCLK* Max selected MCLK output frequency — — — 165 MHz tMCLKH MCLK output clock pulse width HIGH — 2.5 — — ns tCCLKL MCLK output clock pulse width LOW — 2.5 — — ns tSU_MSI MSI to MCLK setup time — 3 — — ns tHD_MSI MSI to MCLK hold time — 0 — — ns tCO_MSO MCLK to MSO delay — fCCLK CCLK input clock frequency — — — 135 MHz tCCLKH CCLK input clock pulse width HIGH — 3.5 — — ns tCCLKL CCLK input clock pulse width LOW — 3.5 — — ns tSU_SSI SSI to CCLK setup time — 4.3 — — ns tHD_SSI SSI to CCLK hold time — 0.8 — — ns ns — — — ns ns Master SPI 0 ns Slave SPI © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 90 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Symbol Parameter Device Min Typ. Max Unit tCO_SSO tEN_SSO CCLK falling edge to valid SSO output — — — 16 ns CCLK falling edge to SSO output enabled — — — 16 ns tDIS_SSO CCLK falling edge to SSO output disabled — — — 16 ns tHIGH_SCSN SCSN HIGH time — 74 — — ns tSU_SCSN SCSN to CCLK setup time — 3.5 — — ns tHD_SCSN SCSN to CCLK hold time — 1.6 — — ns fSCL_I2C SCL input clock frequency for I2C — — — 4 MHz fSCL_I3C SCL input clock frequency for I3C — — — 12 MHz tSCLH SCL input clock pulse width HIGH — — — ns tSCLL SCL input clock pulse width LOW — — — ns tSU_SDA SDA to SCL setup time — — — ns tHD_SDA SDA to SCL hold time — — — ns tCO_SDA SCL falling edge to valid SDA output — — — ns tEN_SDA SCL falling edge to SDA output enabled — — — ns tDIS_SDA SCL falling edge to SDA output disabled — — — ns fDONE_HIGH Last configuration clock cycle to DONE going HIGH — — — MHz tFIO_EN User I/O enabled in Fast I/O Mode LIFCL-40 — LIFCL-17 — tIOEN Config clock to user I/O enabled — — tMWC Additional master MCLK after DONE HIGH — — ns Master MCLK to Hi-Z — — ns I2C/I3C Wake-Up Timing tMCLKZ *Note: — cycles cycles — ns fMCLK has a dependency on HFOSC and is 1/3 of fCLKHF. PROGRAMN Figure 3.14. Master SPI POR/REFRESH Timing © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 91 CrossLink-NX Family Preliminary Data Sheet PROGRAMN Figure 3.15. Slave SPI/I2C/I3C POR/REFRESH Timing Figure 3.16. Master SPI PROGRAMN Timing © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 92 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Figure 3.17. Slave SPI/I2C/I3C PROGRAMN Timing Figure 3.18. Master SPI Configuration Timing © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 93 CrossLink-NX Family Preliminary Data Sheet Figure 3.19. Slave SPI Configuration Timing Figure 3.20. I2C /I3C Configuration Timing © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 94 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Figure 3.21. Master SPI Wake-Up Timing Figure 3.22. Slave SPI/I2C/I3C Wake-Up Timing © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 95 CrossLink-NX Family Preliminary Data Sheet 3.27. JTAG Port Timing Specifications Over recommended operating conditions. Table 3.45. JTAG Port Timing Specifications Symbol fMAX tBTCPH tBTCPL tBTS tBTH tBTRF tBTCO tBTCODIS tBTCOEN tBTCRS tBTCRH tBUTCO tBTUODIS tBTUPOEN Parameter TCK clock frequency TCK [BSCAN] clock pulse width high TCK [BSCAN] clock pulse width low TCK [BSCAN] setup time TCK [BSCAN] hold time TCK [BSCAN] rise/fall time TAP controller falling edge of clock to valid output TAP controller falling edge of clock to valid disable TAP controller falling edge of clock to valid enable BSCAN test capture register setup time BSCAN test capture register hold time BSCAN test update register, falling edge of clock to valid output BSCAN test update register, falling edge of clock to valid disable BSCAN test update register, falling edge of clock to valid enable Min — 20 20 12 6 — — — — — — Typ. — — — — — — — — — — — — — — Max 25 — — — — — — — Units MHz ns ns ns ns mV/ns ns ns ns ns ns ns ns ns TMS TDI tBTS tBTCPH tBTH tBTCP tBTCPL TCK tBTCO tBTCOEN TDO V a lid D a ta tBTCRS Data to be Captured from I/O V a lid D a ta tBTCRH Data Captured tBTUPOEN Data to be driven out to I/O tBTCODIS tBUTCO V a lid D a ta tBTUODIS V a lid D a ta Figure 3.23. JTAG Port Timing Waveforms © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 96 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 3.28. Switching Test Conditions Figure 3.24 shows the output test load that is used for AC testing. The specific values for resistance, capacitance, voltage, and other test conditions are listed in Table 3.46. VT R1 Test Point DUT R2 CL* *CL Includes Test Fixture and Probe Capacitance Figure 3.24. Output Test Load, LVTTL and LVCMOS Standards Table 3.46. Test Fixture Required Components, Non-Terminated Interfaces Test Condition LVTTL and other LVCMOS settings (L ≥ H, H ≥ L) LVCMOS 2.5 I/O (Z ≥ H) R1 R2   CL 0 pF  1 MΩ 1 MΩ 0 pF Timing Ref. LVCMOS 3.3 = 1.5 V LVCMOS 2.5 = VCCIO/2 LVCMOS 1.8 = VCCIO/2 LVCMOS 1.5 = VCCIO/2 VT — — — — LVCMOS 1.2 = VCCIO/2 VCCIO/2 — — 0 pF  100 0 pF  LVCMOS 2.5 I/O (L ≥ Z) 100 0 pF  Note: Output test conditions for all other interfaces are determined by the respective standards. LVCMOS 2.5 I/O (Z ≥ L) LVCMOS 2.5 I/O (H ≥ Z) VCCIO/2 VOH – 0.10 VCCIO — VOL + 0.10 VCCIO © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 97 CrossLink-NX Family Preliminary Data Sheet 4. Pinout Information 4.1. Signal Descriptions* Signal Name Power and GND Vss VSSA_D-PHY VSSSD VCC Bank Type Description — — — — GND GND GND Power VCCAUXA — Power VCCAUX — Power VCCAUXHx — Power Ground for internal FPGA logic and I/O Analog Ground for D-PHY blocks Ground for SERDES blocks Power supply pins for core logic. VCC is connected to 1.0 V (nom.) supply voltage. Power On Reset (POR) monitors this supply voltage. Auxiliary power supply pin for internal analog circuitry. This supply is connected to 1.8 V (nom.) supply voltage. POR monitors this supply voltage. Auxiliary power supply pin for I/O Bank 0, Bank 1, Bank 2, Bank 6, and Bank 7. This supply is connected to 1.8 V (nom.) supply voltage, and is used for generating stable drive current for the I/O. Auxiliary power supply pin for I/O Bank 3, Bank 4, and Bank 5. This supply is connected to 1.8 V (nom.) supply voltage, and is used for generating stable current for the differential input comparators. VCCIOx 0-7 Power VCC_D-PHYx — Power VCCA_D-PHYx — Power VCCPLL_D-PHYx — Power VCCADC18 VCCSD0 VCCPLLSD0 VCCAUXSD Dedicated Pins Dedicated Configuration I/O Pin JTAG_EN — — — — Power Power Power Power 1 Input Power supply pins for I/O bank x. For x = 0, 1, 2, 6, and 7, VCCIO can be connected to (nom.) 1.2 V, 1.5 V, 1.8 V, 2.5 V, or 3.3 V. For x = 3, 4, and 5, VCCIO can be connected to (nom.) 1.0 V, 1.2 V, 1.35 V, 1.5 V, or 1.8 V. There are dedicated and shared configuration pins in banks 0 and 1. POR monitors these banks supply voltages. 1.0 V (nom.) digital power supply for the hardened D-PHY blocks. X = 0, 1 1.8 V (nom.) analog power supply for the hardened D-PHY blocks. X = 0, 1 1.0 V (nom.) power supply for the hardened D-PHY blocks. X = 0, 1 1.8 V (nom.) power supply for the ADC block. 1.0 V (nom.) power supply for the SERDES block. 1.8 V (nom.) power supply for the PLL in the SERDES block. 1.8 V (nom.) auxiliary power supply for the SERDES block. LVCMOS input pin. This input selects the JTAG shared GPIO to be used for JTAG 0 = GPIO 1 = JTAG © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 98 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Dedicated ADC I/O Pins ADC_REF[0, 1] — Input ADC reference voltage, for each of the 2 ADC converters ADC_DP/N[0, 1] — Input Dedicated ADC input pairs, for each of the 2 ADC converters SD0_RXDP/N — Input High Speed Data Differential Input Pairs SD0_TXDP/N — Output SD0_REFCLKP/N — Input High Speed Reference Clock Differential Input Pairs SD0_REXT — Input High Speed External Reference Resistor Input. Resistor connects between to this pin and SD0_REFRET pin. This is used to adjust the onchip differential termination impedance, based on the external resistance value: REXT = 909 Ω, RDIFF = 80 Ω REXT = 976 Ω, RDIFF = 85 Ω REXT = 1.02 kΩ, RDIFF = 90 Ω REXT = 1.15 kΩ, RDIFF = 100 Ω SD0_REFRET — Input High Speed Reference Return Input. These pins should be AC coupled to the VCCPLLSD0 supply D-PHY[0-1]_DP/N[0-3] — Input, Output D-PHY[0-1]_CKP/N — Input Dedicated High Speed I/O Pins High Speed Data Differential Output Pairs Dedicated D-PHY I/O Pins Misc Pins Hardened D-PHY Data Input/Output Pairs, for each of the 4 High Speed lanes in the 2 Hardened D-PHY Blocks Hardened D-PHY Clock Input Pairs, for each of the 2 Hardened D-PHY Blocks NC — No connect. RESERVED — This pin is reserved and should not be connected to anything on the board. General Purpose I/O Pins P[T/B/L/R] [Number]_[A/B] T=0 R = 1, 2 B = 3, 4, 5 L = 6. 7 Input, Output, Bi-Dir Programmable User I/O: [T/B/L/R] indicates the package pin/ball is in T (Top), B (Bottom), L (Left), or R (Right) edge of the device. [Number] identifies the PIO [A/B] pair. [A/B] shows the package pin/ball is A or B signal in the pair. PIO A and PIO B are grouped as a pair. Each A/B pair in the bottom banks supports true differential input and output buffers. When configured as differential input, differential termination of 100 Ω can be selected. Each A/B pair in the top, left and right banks does not support true differential input or output buffer. It supports all single-ended inputs and outputs, and can be used for emulated differential output buffer. Some of these user-programmable I/O are used during configuration, depending on the configuration mode. You need to make appropriate connection on the board to isolate the 2 different functions before/after configuration. Some of these user-programmable I/O are shared with special function pins. These pins, when not used as special purpose pins, can be programmed as I/O for user logic. During configuration the user-programmable I/O are tristated with an internal weak pull-down resistor enabled. If any pin is not used (or not bonded to a package pin), it is tristated and default to have weak pulldown enabled after configuration. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 99 CrossLink-NX Family Preliminary Data Sheet Shared Configuration Pins1, 2 1. These pins can be used for configuration during configuration mode. When configuration is completed, these pins can be used as GPIO, or shared function in GPIO. When these pins are used in dual function, you need to isolate the signal paths for the dual functions on the board. 2. The pins used are defined by the configuration modes detected. Slave SPI or I2C/I3C modes are detected during slave activation. Pins that are not used in the configuration mode selected are tristated during configuration, and can connect directly as GPIO in user’s function. PRxxx /SDA/USER_SDA 1 Input, Output, Bi-Dir Configuration: I2C/I3C Mode: SDA signal User Mode: PRxxx: GPIO User_SDA: SDA signal for I2C/I3C interface PRxxx /SCL/USER_SCL 1 Input, Output, Bi-Dir Configuration: I2C/I3C Mode: SCL signal User Mode: PRxxx: GPIO User_SDA: SCL signal for I2C/I3C interface PRxxx/TDO/SSO 1 Input, Output, Bi-Dir Configuration: Slave SPI Mode: Slave Serial Output User Mode: PRxxx: GPIO TDO: When JTAG_EN = 1, used as TDO signal for JTAG PRxxx/TDI/SSI 1 Input, Output, Bi-Dir Configuration: Slave SPI Mode: Slave Serial Input User Mode: PRxxx: GPIO TDI: When JTAG_EN = 1, used as TDI signal for JTAG PRxxx/TMS/SCSN 1 Input, Output, Bi-Dir PRxxx/TCK/SCLK 1 Input, Output, Bi-Dir PTxxx/MCSNO 0 Input, Output, Bi-Dir Configuration: Slave SPI Mode: Slave Chip Select User Mode: PRxxx: GPIO TMS: When JTAG_EN = 1, used as TMS signal for JTAG Configuration: Slave SPI Mode: Slave Clock Input User Mode: PRxxx: GPIO TCK: When JTAG_EN = 1, used as TCK signal for JTAG Configuration: Master SPI Mode: Chip Select Output User Mode: PTxxx: GPIO PTxxx/MD3 0 Input, Output, Bi-Dir Configuration: Master Quad SPI Mode: I/O3 User Mode: PTxxx: GPIO PTxxx/MD2 0 Input, Output, Bi-Dir Configuration: Master Quad SPI Mode: I/O2 User Mode: PTxxx: GPIO © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 100 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet PTxxx/MSI/MD1 0 Input, Output, Bi-Dir Configuration: Master SPI Mode: Master Serial Input Master Quad SPI Mode: I/O1 User Mode: PTxxx: GPIO PTxxx/MSO/MD0 0 Input, Output, Bi-Dir Configuration: Master SPI Mode: Master Serial Output Master Quad SPI Mode: I/O0 User Mode: PTxxx: GPIO PTxxx/MCSN/PCLKT0_1 0 Input, Output, Bi-Dir Configuration: Master SPI Mode: Master Chip Select Output User Mode: PTxxx: GPIO PCLKT0_0: Top PCLK Input PTxxx/MCLK/PCLKT0_0 0 Input, Output, Bi-Dir Configuration: Master SPI Mode: Master Clock Output User Mode: PTxxx: GPIO PCLKT0_1: Top PCLK Input PTxxx/PROGRAMN 0 Input, Output, Bi-Dir Configuration: PROGRAMN: Initiate configuration sequence when asserted LOW. User Mode: PTxxx: GPIO PTxxx/INITN 0 Input, Output, Bi-Dir Configuration: INITN: Open Drain I/O pin. This signal is driven to LOW when configuration sequence is started, to indicate the device is in initialization state. This signal is released after initialization is completed, and the configuration download can start. You can keep drive this signal LOW to delay configuration download to start. User Mode: PTxxx: GPIO PTxxx/DONE 0 Input, Output, Bi-Dir Configuration: DONE: Open Drain I/O pin. This signal is driven to LOW during configuration time. It is released to indicate the device has completed configuration. You can keep drive this signal LOW to delay the device to wake up from configuration. User Mode: PTxxx: GPIO Shared User GPIO Pins1, 2, 3, 4 1. Shared User GPIO pins are pins that can be used as GPIO, or functional pins that connect directly to specific functional blocks, when device enters into User Mode. 2. Declaring on assigning the pin as GPIO or specific functional pin is done by configuration bitstream, except JTAG pins. 3. JTAG pins are controlled by JTAG_EN signal. When JTAG_EN = 1, the pins are used for JTAG interface. When JTAG = 0, the pins are used as GPIO or specific functional pin defined by configuration bitstream. 4. Refer to package pin file. Shared JTAG Pins PRxxx/TDO/ yyyy 1 Input, Output, Bi-Dir User Mode: PRxxx: GPIO TDO: When JTAG_EN = 1, used as TDO signal for JTAG yyyy: Other possible selectable specific functional © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 101 CrossLink-NX Family Preliminary Data Sheet PRxxx/TDI/yyyy 1 Input, Output, Bi-Dir User Mode: PRxxx: GPIO TDI: When JTAG_EN = 1, used as TDI signal for JTAG yyyy: Other possible selectable specific functional PRxxx/TMS/ yyyy 1 Input, Output, Bi-Dir User Mode: PRxxx: GPIO TMS: When JTAG_EN = 1, used as TMS signal for JTAG yyyy: Other possible selectable specific functional PRxxx/TCK/ yyyy 1 Input, Output, Bi-Dir User Mode: PRxxx: GPIO TCK: When JTAG_EN = 1, used as TCK signal for JTAG Yyyy: Other possible selectable specific functional Shared CLOCK Pins 1 1. Some PCLK pins can also be used as GPLL reference clock input pin. Refer to CrossLink-NX sysCLOCK PLL/DLL Design and Usage Guide (FPGA-TN-02095). PBxxx/PCLK[T,C][3,4,5]_[03]/yyyy 3, 4, 5 Input, Output, Bi-Dir User Mode: PBxxx: GPIO PCLK: Primary Clock or GPLL Refclk signal [T,C] = True/Complement when using differential signaling [3,4,5] = Bank [0-3] Up to 4 signals in the bank yyyy: Other possible selectable specific functional User Mode: PTxxx: GPIO PCLKT: Primary Clock or GPLL Refclk signal (Only Single Ended) [0-1] Up to 2 signals in the bank yyyy: Other possible selectable specific functional PTxxx/PCLKT0_[0-1]/yyyy 0 Input, Output, Bi-Dir PRxxx/PCLKT[1,2]_[0-2]/yyyy 1, 2 Input, Output, Bi-Dir User Mode: PRxxx: GPIO PCLKT: Primary Clock or GPLL Refclk signal (Only Single Ended) [0-2] Up to 3 signals in the bank yyyy: Other possible selectable specific functional PLxxx/PCLKT[6,7]_[0-2]/yyyy 6, 7 Input, Output, Bi-Dir User Mode: PLxxx: GPIO PCLKT: Primary Clock or GPLL Refclk signal (Only Single Ended) [0-2] Up to 3 signals in the bank yyyy: Other possible selectable specific functional PBxxx/LRC_GPLL[T,C]_IN/yyyy 3 Input, Output, Bi-Dir User Mode: PBxxx: GPIO LRC_GPLL: Lower Right GPLL Refclk signal [T,C] = True/Complement when using differential signaling yyyy: Other possible selectable specific functional PBxxx/LLC_GPLL[T,C]_IN/yyyy 5 Input, Output, Bi-Dir User Mode: PBxxx: GPIO LLC_GPLL: Lower Left GPLL Refclk signal [T,C] = True/Complement when using differential signaling yyyy: Other possible selectable specific functional PLxxx/ULC_GPLLT_IN/yyyy 7 Input, Output, Bi-Dir User Mode: PLxxx: GPIO ULC_GPLL: Upper Left GPLL Refclk signal (Only Single Ended) yyyy: Other possible selectable specific functional © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 102 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet PRxxx/URC_GPLLT_IN/yyyy 1 Input, Output, Bi-Dir User Mode: PRxxx: GPIO URC_GPLL: Upper Right GPLL Refclk signal (Only Single Ended) yyyy: Other possible selectable specific functional Shared VREF Pins PBxxx/VREF[3,4,5]_[1-2]/yyyy 3, 4, 5 Input, Output, Bi-Dir User Mode: PBxxx: GPIO VREF: Reference Voltage for DDR memory function [3,4,5] = Bank [1-2] Up to VREFs for each bank yyyy: Other possible selectable specific functional Shared ADC Pins PBxxx/ADC_C[P,N]nn/yyyy 3, 4, 5 Input, Output, Bi-Dir User Mode: PBxxx: GPIO ADC_C: ADC Channel Inputs [P,N] = Positive or Negative Input nn = ADC Channel number (0 – 15) yyyy: Other possible selectable specific functional 3, 5 Input, Output, Bi-Dir User Mode: PBxxx: GPIO COMP: Differential Comparator Input [P,N] = Positive or Negative Input [1-3] = Input to Comparators 1-3 yyyy: Other possible selectable specific functional 3, 5 Input, Output, Bi-Dir User Mode: PBxxx: GPIO SGMII_RX: Differential SGMII RX Inputs [P,N] = Positive or Negative Input [0-1] = Input to SGMII RX0 or RX1 yyyy: Other possible selectable specific functional Shared Comparator Pins PBxxx/COMP[1-3][P,N]/yyyy Shared SGMII Pins PBxxx/SGMII_RX[P,N][01]/yyyy *Note: Not all signals are available as external pins in all packages. Refer to the Pinout List file for various package details. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 103 CrossLink-NX Family Preliminary Data Sheet 4.2. Pin Information Summary 4.2.1. CrossLink-NX Family LIFCL-17 Pin Information Summary 72wlcsp LIFCL-40 72 QFN 121csfBGA 256caBGA 121csfBGA 72 QFN 289csBGA 256caBGA 400caBGA User I/O Pins Bank 0 Bank 1 Bank 2 General Bank 3 Purpose Inputs/Outputs Bank 4 per Bank Bank 5 Bank 6 Bank 7 Total Single-Ended User I/O Bank 0 Bank 1 Bank 2 Differential Bank 3 Input / Output Bank 4 Pairs Bank 5 Bank 6 Bank 7 Total Differential I/O — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 12 21 28 32 32 10 28 22 185 0 0 0 — — — 0 0 — 0 0 0 — — — 0 0 — 0 0 0 — — — 0 0 — 0 0 0 — — — 0 0 — 0 0 0 — — — 0 0 — 0 0 0 — — — 0 0 — 0 0 0 — — — 0 0 — 0 0 0 — — — 0 0 — 0 0 0 32 32 10 0 0 74 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — VCC_D-PHYx VCCA_D-PHYx VCCPLL_D-PHYx VCCSD0 VCCPLLSD0 VCCADC18 — — — — — — — — — — — — — — — — — — — — — — — — — 8 1 3 3 1 1 2 2 2 2 1 2 2 2 2 2 2 1 1 Total Power Pins — — — — — — — — 40 Power Pins VCC, VCCECLK VCCAUXA VCCAUX VCCAUXHx VCCAUXSD VCCIO Bank 0 Bank 1 Bank 2 Bank 3 Bank 4 Bank 5 Bank 6 Bank 7 — — — — — — — — — © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 104 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Pin Information Summary 72wlcsp GND Pins Vss VSSADC VSSSD VSSA_D-PHY Total GND Pins Dedicated Pins Dedicated ADC Channels (pairs) Dedicated ADC Reference Voltage Pins Dedicated D-PHY Data Channels (pairs) Dedicated D-PHY Clock (pairs) Dedicated Misc Pins JTAGEN NC RESERVED Total Dedicated Pins Shared Pins Bank 0 Bank 1 Bank 2 Shared Bank 3 Configuration Bank 4 Pins Bank 5 Bank 6 Bank 7 Bank 0 Bank 1 Bank 2 Bank 3 Shared JTAG Pins Bank 4 Bank 5 Bank 6 Bank 7 Bank 0 Bank 1 Bank 2 Bank 3 Shared PCLK Pins Bank 4 Bank 5 Bank 6 Bank 7 LIFCL-17 LIFCL-40 72 QFN 121csfBGA 256caBGA 121csfBGA 72 QFN 289csBGA 256caBGA 400caBGA — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 37 1 12 7 57 — — — — — — — — 0 — — — — — — — — 0 — — — — — — — — 8 — — — — — — — — 2 1 — — — 1 — — — 1 — — — 1 — — — 1 — — — 1 — — — 1 — — — 1 — — — 1 11 — — 0 — — 0 — — 0 — — 0 — — 0 — — 0 — — 0 — — 0 10 6 0 0 0 0 0 0 0 4 0 0 0 0 0 0 — — — — — — — 0 0 0 0 0 0 4 0 0 0 0 0 0 — — — — — — — 0 0 0 0 0 0 4 0 0 0 0 0 0 — — — — — — — 0 0 0 0 0 0 4 0 0 0 0 0 0 — — — — — — — 0 0 0 0 0 0 4 0 0 0 0 0 0 — — — — — — — 0 0 0 0 0 0 4 0 0 0 0 0 0 — — — — — — — 0 0 0 0 0 0 4 0 0 0 0 0 0 — — — — — — — 0 0 0 0 0 0 4 0 0 0 0 0 0 — — — — — — — 0 0 0 0 0 0 4 0 0 0 0 0 0 2 3 3 8 8 8 3 — — — — — — — — 3 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 105 CrossLink-NX Family Preliminary Data Sheet Pin Information Summary Shared GPLL Pins Shared VREF Pins Shared ADC Channels (pairs) Shared Comparator Channels (pairs) Shared SGMII Channels (pairs) 72wlcsp Bank 0 0 Bank 1 — LIFCL-17 LIFCL-40 72 QFN 121csfBGA 256caBGA 121csfBGA 72 QFN 289csBGA 256caBGA 400caBGA 0 0 0 0 0 0 0 0 — — — — — — — 0 Bank 2 0 0 0 0 0 0 0 0 0 Bank 3 — — — — — — — — 2 Bank 4 — — — — — — — — 0 Bank 5 — — — — — — — — 2 Bank 6 0 0 0 0 0 0 0 0 0 Bank 7 — — — — — — — — 2 Bank 0 0 0 0 0 0 0 0 0 0 Bank 1 0 0 0 0 0 0 0 0 0 Bank 2 0 0 0 0 0 0 0 0 0 Bank 3 — — — — — — — — 2 Bank 4 — — — — — — — — 2 Bank 5 — — — — — — — — 2 Bank 6 0 0 0 0 0 0 0 0 0 Bank 7 0 0 0 0 0 0 0 0 0 Bank 0 0 0 0 0 0 0 0 0 0 Bank 1 0 0 0 0 0 0 0 0 0 Bank 2 0 0 0 0 0 0 0 0 0 Bank 3 — — — — — — — — 12 Bank 4 — — — — — — — — 0 Bank 5 — — — — — — — — 4 Bank 6 0 0 0 0 0 0 0 0 0 Bank 7 0 0 0 0 0 0 0 0 0 Bank 0 0 0 0 0 0 0 0 0 0 Bank 1 0 0 0 0 0 0 0 0 0 Bank 2 0 0 0 0 0 0 0 0 0 Bank 3 — — — — — — — — 3 Bank 4 — — — — — — — — 0 Bank 5 — — — — — — — — 3 Bank 6 0 0 0 0 0 0 0 0 0 Bank 7 0 0 0 0 0 0 0 0 0 Bank 0 0 0 0 0 0 0 0 0 0 Bank 1 0 0 0 0 0 0 0 0 0 Bank 2 0 0 0 0 0 0 0 0 0 Bank 3 — — — — — — — — 0 Bank 4 0 0 0 0 0 0 0 0 0 Bank 5 — — — — — — — — 2 Bank 6 0 0 0 0 0 0 0 0 0 Bank 7 0 0 0 0 0 0 0 0 0 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 106 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet 5. Ordering Information 5.1. CrossLink-NX Part Number Description LIFCL - 40 - X XXXX X Device Family CrossLink-NX FPGA Grade C = Commercial I = Industrial Logic Capacity 40 = 39K Logic Cells Package SG72 = 72-pin QFN MG121 = 121-ball csfBGA BG256 = 256-ball caBGA MG289 = 289-ball csBGA BG400 = 400-ball caBGA Speed (same number for HP and LP) 7 = Slowest 8 9 = Fastest LIFCL - 17 - X XXXX X Device Family CrossLink-NX FPGA Grade C = Commercial I = Industrial Logic Capacity 17 = 17K Logic Cells Package UWG72 = 72-ball WLCSP SG72 = 72-pin QFN MG121 = 121-ball csfBGA BG256 = 256-ball caBGA Speed (same number for HP and LP) 7 = Slowest 8 9 = Fastest © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 107 CrossLink-NX Family Preliminary Data Sheet 5.2. Ordering Part Numbers 5.2.1. Commercial Part Number Speed Package Pins Temp. Logic Cells (K) –7 –8 –9 –7 –8 –9 –7 –8 –9 –7 –8 –9 –7 –8 –9 –7 –8 –9 –7 –8 –9 –7 –8 –9 –7 –8 –9 Lead free WLCSP Lead free WLCSP Lead free WLCSP Lead free QFN Lead free QFN Lead free QFN Lead free csfBGA Lead free csfBGA Lead free csfBGA Lead free caBGA Lead free caBGA Lead free caBGA Lead free QFN Lead free QFN Lead free QFN Lead free csfBGA Lead free csfBGA Lead free csfBGA Lead free csBGA Lead free csBGA Lead free csBGA Lead free caBGA Lead free caBGA Lead free caBGA Lead free caBGA Lead free caBGA Lead free caBGA 72 72 72 72 72 72 121 121 121 256 256 256 72 72 72 121 121 121 289 289 289 256 256 256 400 400 400 Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial Commercial 17 17 17 17 17 17 17 17 17 17 17 17 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 Part Number LIFCL-17-7UWG72I LIFCL-17-8UWG72I LIFCL-17-9UWG72I LIFCL-17-7SG72I LIFCL-17-8SG72I LIFCL-17-9SG72I LIFCL-17-7MG121I LIFCL-17-8MG121I LIFCL-17-9MG121I LIFCL-17-7BG256I Speed –7 –8 –9 –7 –8 –9 –7 –8 –9 –7 Package Lead free WLCSP Lead free WLCSP Lead free WLCSP Lead free QFN Lead free QFN Lead free QFN Lead free csfBGA Lead free csfBGA Lead free csfBGA Lead free caBGA Pins 72 72 72 72 72 72 121 121 121 256 Temp. Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Logic Cells (K) 17 17 17 17 17 17 17 17 17 17 LIFCL-17-8BG256I LIFCL-17-9BG256I LIFCL-40-7SG72I LIFCL-40-8SG72I –8 –9 –7 –8 Lead free caBGA Lead free caBGA Lead free QFN Lead free QFN 256 256 72 72 Industrial Industrial Industrial Industrial 17 17 39 39 LIFCL-17-7UWG72C LIFCL-17-8UWG72C LIFCL-17-9UWG72C LIFCL-17-7SG72C LIFCL-17-8SG72C LIFCL-17-9SG72C LIFCL-17-7MG121C LIFCL-17-8MG121C LIFCL-17-9MG121C LIFCL-17-7BG256C LIFCL-17-8BG256C LIFCL-17-9BG256C LIFCL-40-7SG72C LIFCL-40-8SG72C LIFCL-40-9SG72C LIFCL-40-7MG121C LIFCL-40-8MG121C LIFCL-40-9MG121C LIFCL-40-7MG289C LIFCL-40-8MG289C LIFCL-40-9MG289C LIFCL-40-7BG256C LIFCL-40-8BG256C LIFCL-40-9BG256C LIFCL-40-7BG400C LIFCL-40-8BG400C LIFCL-40-9BG400C 5.2.2. Industrial © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 108 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Part Number LIFCL-40-9SG72I LIFCL-40-7MG121I LIFCL-40-8MG121I LIFCL-40-9MG121I LIFCL-40-7MG289I LIFCL-40-8MG289I LIFCL-40-9MG289I LIFCL-40-7BG256I LIFCL-40-8BG256I LIFCL-40-9BG256I LIFCL-40-7BG400I LIFCL-40-8BG400I LIFCL-40-9BG400I Speed –9 –7 –8 –9 –7 –8 –9 –7 –8 –9 –7 –8 –9 Package Lead free QFN Lead free csfBGA Lead free csfBGA Lead free csfBGA Lead free csBGA Lead free csBGA Lead free csBGA Lead free caBGA Lead free caBGA Lead free caBGA Lead free caBGA Lead free caBGA Lead free caBGA Pins 72 121 121 121 289 289 289 256 256 256 400 400 400 Temp. Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Industrial Logic Cells (K) 39 39 39 39 39 39 39 39 39 39 39 39 39 © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 109 CrossLink-NX Family Preliminary Data Sheet Supplemental Information For Further Information A variety of technical notes for the CrossLink-NX family are available. For further information on interface standards refer to the following websites:  JEDEC Standards (LVTTL, LVCMOS, SSTL) – www.jedec.org  PCI – www.pcisig.com © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. 110 FPGA-DS-02049-0.84 CrossLink-NX Family Preliminary Data Sheet Revision History Revision 0.84, December 2020 Section Change Summary General Description DC and Switching Characteristics Updated Table 1.1.   Added note 3 in Table 3.5. Updated Table 3.26. Revision 0.83, November 2020 Section All General Description Architecture Change Summary Removed ALUREG/ALU and TransFR references across the document. Updated Table 1.1.    DC and Switching Characteristics Pinout Information Updated Figure 2.1 and Figure 2.2. Update sysI/O Banking Scheme section content to correct the bank information for 40K and 17K device. Removed VCCIO supplies should be powered-up before or together with the VCC and VCCAUX supplies information in Typical sysI/O I/O Behavior During Power-up section.   Updated symbol and condition values in Table 3.1 and Table 3.9. Updated notes in Table 3.2. Removed note 2: All VCCIO supplies with same voltage should be connected together.  Updated Table 3.26 to correct the package values for LVDS and subLVDS. Updated table in Signal Descriptions* and Pin Information Summary. Revision 0.82, August 2020 Section Introduction Cryptographic Engine Change Summary Added Cryptographic Engine information in Features section. Added this section. Revision 0.81.01, May 2020 Section Architecture DC and Switching Characteristics Change Summary      Updated Table 3.2 and added footnote 5. Updated content of Large RAM section. Updated Primary Clocks and Dynamic Clock Control to add domain. Updated Device Configuration section to add the following statements: The test access port is supported for VCCIO1 = 1.8 V - 3.3 V.  JTAG, SSPI, MSPI, I2C and I3C are supported for VCCIO = 1.8 V - 3.3 V.  Updated MIPI D-PHY Blocks section.  Updated content and figures of Peripheral Component Interconnect Express (PCIe) section. Updated the following tables:  Table 3.10  Table 3.11  Table 3.26  Table 3.44. © 2020 Lattice Semiconductor Corp. All Lattice trademarks, registered trademarks, patents, and disclaimers are as listed at www.latticesemi.com/legal. All other brand or product names are trademarks or registered trademarks of their respective holders. The specifications and information herein are subject to change without notice. FPGA-DS-02049-0.84 111 www.latticesemi.com
LIFCL-17-8MG121I
1. 物料型号:文档中没有明确列出特定的物料型号,但从上下文推测,文档描述的可能是Lattice Semiconductor的CrossLink-NX系列FPGA。

2. 器件简介:CrossLink-NX系列FPGA是高性能的可编程逻辑设备,支持多种高速接口和加密功能,适用于多种应用场景。

3. 引脚分配:文档提供了详细的引脚分配信息,包括电源引脚、地引脚、专用引脚和共享引脚。例如,VCC是核心逻辑和I/O的电源供电引脚,VCCAUX是用于内部模拟电路的辅助电源引脚。

4. 参数特性:文档列出了FPGA的多种电气特性,包括绝对最大额定值、推荐操作条件、电源上升率、上电序列、片上可编程终止以及热插拔规格等。

5. 功能详解:文档详细介绍了FPGA的多个功能块,包括MIPI D-PHY、PCIe接口、加密引擎等。例如,MIPI D-PHY支持高速和低功耗模式,PCIe接口支持Gen 1和Gen 2速度。

6. 应用信息:虽然文档没有直接提供应用案例,但从FPGA的特性可以推断,它适用于需要高速数据传输和安全特性的应用,如通信、工业控制、汽车电子等。

7. 封装信息:文档提到了多种封装类型,包括72引脚的WLCSP、QFN,以及更大引脚数的BGA封装。
LIFCL-17-8MG121I 价格&库存

很抱歉,暂时无法提供与“LIFCL-17-8MG121I”相匹配的价格&库存,您可以联系我们找货

免费人工找货
LIFCL-17-8MG121I
    •  国内价格
    • 1+142.01042
    • 5+140.29945
    • 50+139.44397
    • 100+133.45558

    库存:475