0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CV3-1000

CV3-1000

  • 厂商:

    LEM(莱姆)

  • 封装:

  • 描述:

    CV3-1000 - Voltage Transducer - LEM

  • 数据手册
  • 价格&库存
CV3-1000 数据手册
Voltage Transducer CV 3-1000 For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). VPN = 700 V Electrical data VPN VP VS KN RL CL VC IC Primary nominal r.m.s. voltage Primary voltage, measuring range Secondary Analog voltage @ VP max Conversion ratio Load resistance Capacitive loading Supply voltage (± 5 %) Current consumption 700 0 .. ± 1000 10 1000 V / 10 V ≥1 ≤5 ± 15 32 + VS / R L V V V kΩ nF V mA Features • Closed loop (compensated) voltage transducer • Insulated plastic case recognized according to UL 94-V0 • Patent pending. Advantages Accuracy - Dynamic performance data Max ± 0.2 ± 0.6 ±5 ± 13 0.3 800 DC .. 500 XG VO Overall accuracy @ VP max Offset voltage @ VP = 0 TA = 25°C - 40°C .. + 85°C TA = 25°C - 40°C .. + 85°C % % mV mV µs V/µs kHz • • • • • • tr Response time 1) @ 90 % of VPN dv/dt dv/dt accurately followed f Frequency bandwidth (- 1 dB) @ 50 % of VPN Excellent accuracy Very good linearity Low thermal drift Low response time High bandwidth High immunity to external interference • Low disturbance in common mode. Applications • • • • • Single or three phases inverter Propulsion and braking chopper Propulsion converter Auxiliary converter Battery charger. General data TA TS P R1 m Ambient operating temperature Ambient storage temperature Total primary power loss Primary resistance Mass Standards - 40 .. + 85 °C - 45 .. + 90 °C 3.1 W 160 kΩ 560 g EN 50155 : 1995 Application Domain • Traction. Note : 1) With a dv/dt of 800 V/µs 050805/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 1/3 LEM Components w w w .lem.com Voltage transducer CV 3-1000 Isolation characteristics Vd Ve dCp dCl CTI R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn R.m.s. voltage for partial discharge extinction @ 10pC Creepage distance Clearance distance Comparative Tracking Index (Group I ) 6 2 Min 83.80 76.40 600 kV kV mm mm Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. 050805/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 2/3 LEM Components w w w .lem.com Dimensions CV 3-1000 Front view (in mm. 1 mm = 0.0394 inch) Left view Connection Rep. A-B Clearance 76.40 mm Creepage 83.80 mm Top view Mechanical characteristics • General tolerance • Transducer fastening Recommended fastening torque • Connection of primary • Connection of secondary • Recommended fastening torque ± 0.3 mm 3 holes ∅ 5.5 mm 3 M5 steel screws 3.8 Nm or 2.80 Lb. -Ft. 2 M5 threaded studs 4 M5 threaded studs 2.2 Nm or 1.62 Lb. -Ft. Remarks • VS is positive when VP is applied on terminal +HT. • CEM tested with a shielded secondary cable, shield connected to 0 V at both ends, or disconnected. • This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. 050805/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 3/3 LEM Components w w w .lem.com
CV3-1000 价格&库存

很抱歉,暂时无法提供与“CV3-1000”相匹配的价格&库存,您可以联系我们找货

免费人工找货