Current Transducer FA-050 .. 100PV
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 50 .. 100 A
Electrical data
Primary nominal DC current Primary current measuring range Type
IPN (A)
50 100
IP (A)
0 .. ± 70 0 .. ± 130 FA - 050PV FA - 050PV FA - 100PV FA - 100PV
VOUT IC VC Vd
Output voltage @ ± IPN , RL = 10 kΩ , T A = 25°C ± 4 Current consumpution 16 + IPN /1000
Features
V mA V kV
±4 16+ IPN /2000 ± 15 2.5
Supply voltage (± 5 %) R.m.s. voltage for AC isolation test, AC50/60Hz, 1 min
• Hall effect measuring principle • PC Board Mount Type • Low power consumption • Extended measuring range (3 x IPN ) • Galvanic isolation between Primary • Isolation voltage 2000V
and Secondary circuit
A ccuracy-Dynamic performance data
ε
X
L
VOE VOH VOT TCε G tr f
Accuracy @ T A = 25°C, @ ± 15V (± 5%) Linearity (0 .. ± IPN ) Electrical offset voltage, T A = 25°C Hysteresis offset voltage @ IP = 0, after an excursion of 1 x IPN Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of IP Frequency bandwidth (- 1 dB)
< ± 1.5 @IPN < ± 0.25 ± 0.016 < ± 0.012 < ± 0.04 < ± 0.1