Current Transducers HAC 100..800-S
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 100 .. 800 A
Electrical data
Primary nominal current rms IPN (A) 100 200 300 400 500 600 800 Primary current measuring range IPM (A) ± ± ± ± ± ± ± 300 600 900 1200 1500 1800 1800 Type RoHS since date code 46256 46220 planned 46242 planned 46186 46219
Features
• Hall effect measuring principle • Galvanic isolation between primary • Isolation voltage 2500 V • Low power consumption • Extended measuring range (3 x IPN)
and secondary circuit
HAC HAC HAC HAC HAC HAC HAC
100-S 200-S 300-S 400-S 500-S 600-S 800-S
VC IC RIS VOUT ROUT RL
Supply voltage (± 5 %) Current consumption HAC 100..300-S
± 15 < ± 18 HAC 400..800-S < ± 25 Isolation resistance @ 500 VDC > 1000 Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C ± 4 Output internal resistance 100 Load resistance > 10
V mA mA MΩ V Ω kΩ
Advantages
• Easy mounting • Small size and space saving • Only one design for wide current • High immunity to external
interference. ratings range
Accuracy - Dynamic performance data
ε
X
L
VOE VOH TCVOE TCVOUT tr BW
Accuracy @ IPN, TA = 25°C (excluding offset) Linearity error (0 .. ± IPN) Electrical offset voltage, TA = 25°C Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN Temperature coefficient of VOE Temperature coefficient of VOUT (% of reading) Response time to 90% of IPN step Frequency bandwidth (- 3 dB)1)
< ± 1 % of IPN < ± 1 % of IPN < ± 30 mV < ± 35 mV 5.5 > 220 kV mm mm
Application examples
According to EN 50178 and CEI 61010-1 standards and following conditions :
· Over voltage category · Pollution degree PD2 · Non-uniform field
OV 3
EN 50178 dCp, dCI, V W Single isolation Reinforced isolation Rated isolation voltage 2.200 V 5 kVac 1.250 V 1 kVac
CEI 61010-1 Nominal voltage Cat III1000 V rrms Cat II 500 V ms
Cat III 250 V rms Cat II 600 rms
Note : 2) Between primary and secondary
Page 2/3
0 61114/7
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HAC 100..800-S (in mm. 1 mm = 0.0394 inch)
Top View
20
Molex 5045-04AG
d 4.5
4321
10
7.5
42
Left View
Front View
24
18 21 58
23
9
1
4.5
20
d 2.5
Terminal Identification 1.....+Vcc 2.....-Vcc 3.....Output 4.....0V
Mechanical characteristics
TOLERANCE : +/-0.5 mm UNLESS OTHERWISE SPECIFIED • General tolerance ± 0.5 mm
Safety
UNIT : mm SCALE : 1/1
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions.
Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected.
Page 3/3
0 61114/7
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.