Current Transducer HAL 100-S
For the electronic measurement of DC, AC and pulsed currents, with a galvanic isolation between the primary (high power) circuit and the secondary (electronic) circuit.
IPN = 100 A
Electrical data
IPN IP ÎP VOUT RL VC IC Vb Vd Ris Primary nominal DC or rms current Primary current, measuring range Overload capacity (Ampere Turns) Analogue output voltage @ ± IPN Load resistance TA = 0 .. + 70°C TA = - 25 .. + 85°C Supply voltage (± 5 %) Current consumption (max) Rms rated voltage1) Rms voltage for AC isolation test, 50 Hz, 1 mn Isolation resistance @ 500 VDC 100 0 .. ± 300 30000 ±4 >1 >3 ± 15 25 500 3 > 500 A A A V kΩ kΩ V mA V kV MΩ
Features
• Open loop transducer using Hall
Effect
• Panel mounting - Horizontal or
Vertical
• Insulated plastic case to UL 94-V0.
Advantages
• • • • • •
Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference • Current overload capability • Low power consumption • Wide dynamic range, 50 to 600 A in one package.
Accuracy - Dynamic performance data
ε
X
L
Accuracy 2) @ IPN, TA = 25°C, @ ± 15 V Linearity 2) Electrical offset voltage @ IP = 0, TA = 25°C Residual offset voltage @ IP = 0 after an overload of 3 x IPN Thermal drift of offset voltage TA = - 25 .. + 85°C Thermal drift of gain TA = - 25 .. + 85°C Response time @ 90 % of IP di/dt accurately followed Frequency bandwidth (- 3 dB) 3)
VOE VOM VOT TCε G tr di/dt f
±1 ± 0.5 Max ± 10 ± 10 ±1 ± 0.05 50 DC .. 50
% % mV mV mV/°K %/°K µs A/µs kHz
Applications
• AC variable speed drives and servo
motor drives
General data
TA TS m Ambient operating temperature Ambient storage temperature Mass Standards Safety EMC Deviation in output when tested to EN 61000-4-6 Deviation in output when tested to EN 61000-4-4 - 25 .. + 85 °C - 25 .. + 85 °C 75 g EN50178 (1994) EN50082-2 (1992) EN50081-1 (1992) < 10 % of IPN < 10 % of IPN
• Static converters for DC motor drives • Battery supplied applications • Uninterruptable Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Notes :
1) 2) 3)
Reinforced insulation, Overvoltage Category II, Pollution Degree 2 Excludes the electrical offset Refer to derating curves in the technical file to avoid excessive core heating at high frequency 001114/2
LEM Components
www.lem.com
Dimensions HAL 100-S (in mm. 1 mm = 0.0394 inch)
Bottom view Left view
Secondary terminals
Terminal Terminal Terminal Terminal 1 2 3 4 : supply voltage + 15 V : supply voltage - 15 V : output : 0V
Front view Mechanical characteristics
• General tolerance • Primary through-hole • Connection of secondary
± 0.5 mm 20 mm x 15 mm Molex 5045-04-A
Remarks
• VOUT is positive when IP flows in the direction of the arrow. • Temperature of the primary conductor should not exceed
90°C.
• This is a standard model. For different versions (supply
voltages, secondary connections, unidirectional measurements, operating temperatures, etc.) please contact us.
L EM have a policy of continual product improvement and the company reserves the right to revise the above specification without prior notice.
很抱歉,暂时无法提供与“HAL100-S”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+211.77720
- 10+204.93000