Current Transducers HAS 50..600-P
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
= 50..600 A
VOUT = ± 4 V
Electrical data
Primary nominal current rms IPN (A) 50 100 200 300 400 500 600 Primary current, measuring range IPM (A) ± ± ± ± ± ± ± 150 300 600 900 900 900 900 Type RoHS since date code 46065 46062 planned planned 46131 46216 planned
HAS HAS HAS HAS HAS HAS HAS
50-P 100-P 200-P 300-P 400-P 500-P 600-P
Features
• Hall effect measuring principle • Galvanic isolation between primary • Isolation voltage 3000 V~ • Low power consumption • Extended measuring range (3 x IPN) • Insulated plastic case made of
polycarbonate PBT recognized according to UL 94-V0 • Right angle pins for direct PCB mounting and secondary circuit
VC IC ÎP Vd Vb RIS VOUT ROUT RL
Supply voltage (± 5 %) Current consumption Overload capability Rms voltage for AC isolation test, 50 Hz, 1 min Rated isolation voltage rms, safe separation Isolation resistance @ 500 VDC Output voltage (Analog)@ ± IPN, RL = 10 kΩ, TA = 25°C Output internal resistance approx. Load resistance 6)
± 15 V ± 15 mA 30,000 At 3 kV 5001) V > 1000 MΩ ± 4 V ± 40 mV 100 Ω >1 kΩ
Accuracy - Dynamic performance data