Current Transducer HAT 200..1500-S
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 200..1500 A VOUT = ± 4 V
Electrical data
Primary nominal r.m.s. current IPN (A) 200 400 500 600 750 800 1000 1200 1500 Primary current measuring range 4) IP (A) ± ± ± ± ± ± ± ± ± 600 1200 1500 1800 2250 2400 3000 3000 3000 Type
HAT HAT HAT HAT HAT HAT HAT HAT HAT
200-S 400-S 500-S 600-S 750-S 800-S 1000-S 1200-S 1500-S
Features
• Hall effect measuring principle • Galvanic isolation between primary • • • •
and secondary circuit Isolation voltage 3000 V Low power consumption Extended measuring range(3 x IPN) Insulated plastic case recognized according to UL 94-V0
VC IC R IS VOUT ROUT RL
Supply voltage (± 5 %) 4) Current consumption Isolation resistance @ 500 VDC Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C Output internal resistance Load resistance
± 15 ± 15 > 1000 ±4 100 > 10
V mA MΩ V Ω kΩ
Advantages
• Easy mounting • Small size and space saving • Only one design for wide current
ratings range
Accuracy-Dynamic performance data
ε
X
L
VOE VOH VOT TCε G tr f
Accuracy @ IPN, TA = 25°C (without offset) Linearity error 1) (0 .. ± IPN) Electrical offset voltage, TA = 25°C Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of IP Frequency bandwidth 2) (- 3 dB)
< ± 1 % of IPN < ± 1 % of IPN < ± 20 mV < ± 10 mV 11 275
kV mm mm
051011/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 2/3
LEM Industrial
www.lem.com
Dimensions HAT 200..1500-S (in mm. 1 mm = 0.0394 inch) Top view
H AT-S SERIES
12 = = 12 = =
(unit = mm)
H AT 500-S to 1 500-S
Positive curren flow current t
70
10
12
5
30.5 30.5 x 40.5
1
15.5
4
Molex 5045-04A 6
78
4
10
30
65
46 Max.
24
29
38
1
Front view
H AT 200-S
4
90
1 (+)
All holes O 4.5mm
Pins arrangement 2 3 (-) Output
4 0V
Fixation by base-plate or on bus bar
Mechanical characteristics
• General tolerance • Transducer fastening
30.5 x 40.5
Safety
with M screws 4
• Connection of secondary
± 1 mm By base-plate 1or on 432 bus bar Molex 5045-04A with M4 screws. All slots ∅ 4.5 mm Molex 5045-04A
Pins arrangement: 1 (+) 2 (-) 3 Output 4 0V
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements 99/05 in accordance with the following manufacturer's operating instructions.
Caution, risk of electrical shock
Remarks
• IS is positive when IP flows in the direction of the arrow. • Temperature of the primary conductor should not exceed
100°C.
When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. 0 51011/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 3/3
LEM Industrial
www.lem.com