Current Transducers HAZ 4000..20000-SRU
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 4000..20000 A VOUT = 0-10 V (T-RMS DC)
Electrical data
Primary nominal r.m.s. current IPN (A) 4000 6000 10000 12000 14000 20000 Primary current measuring range IP (A) ± ± ± ± ± ± 4000 6000 10000 12000 14000 20000 Type
HAZ 4000-SRU HAZ 6000-SRU HAZ 10000-SRU HAZ 12000-SRU HAZ 14000-SRU HAZ 20000-SRU
Features
• Hall effect measuring principle • Galvanic isolation between primary
± 15 ± 30 30,000 > 1000 0-10 100 > 10 V mA A MΩ V DC Ω kΩ
VC IC IOC RIS VOUT ROUT RL
Supply voltage (± 5 %) Current consumption Overload capacity Isolation resistance @ 500 VDC Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C Output internal resistance approx. Load resistance
• True-rms, 0-10V DC voltage output • Isolation voltage 12kV Rms/ 50 Hz • Low power consumption • Package in PBT meeting UL 94-V0
/ 1 min
and secondary circuit
Advantages
• Easy mounting • Small size and space savings • Only one design for wide current • High immunity against external
interference ratings range
Accuracy - Dynamic performance data
X
ε
L
VOE VOH VOT TCε G tr f
Accuracy @ IPN, TA = 25°C (without offset) Linearity error 1) (0 .. ± IPN) Electrical offset voltage, TA = 25°C, @ IP = 0 Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of IPN Frequency range, ±3 dB, small signal 2)
45 > 45 220
kV kV kV mm mm V
0 60428/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 2/3
LEM
www.lem.com
Dimensions HAZ 4000..20000-SRU (in mm. 1 mm = 0.0394 inch)
FUJICON F2023A 6
1
Connection Circuit
HAZxxx-SRU
1 +Vc -Vc 0V OUTPUT GND T.P. (Internal test point used during factory calibrations) RL=10K ohm
6
5
4
3
2
1
+Vc
50
48
T.P.
GND OUTPUT 0V -Vc
HAZ 10000-SRU
250 +/-1.5 235
2 3
4-D6
4 5
160 +/-1.5 65 125
6
442 ±+/-1 1.5 ± 2 .5 42 1
161 +/-1 16 ± 1 162 2 ± 2
75
Operation Principle
7.5
+Vc
200 M5
Terminal 1...+Vc 2...-Vc 3...0V 4...OUTPUT 5...GND 6...T.P. General tolerance +/-0.5
Output 0V Ip -Vc
Mechanical characteristics
• General tolerance • Aperture for primary conductor
± 0.5 mm 162 mm x 42 mm (± 2 mm) • Transducer fastening 4 x M5 (not supplied) • Recommended fastening torque < 5 Nm • Connection of secondary Fujicon F2023A (6 terminals)
50 48 35
Safety
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions.
Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. 0 60428/2
Remarks
• Temperature of the primary conductor should not exceed
120°C.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 3/3
LEM
www.lem.com
很抱歉,暂时无法提供与“HAZ14000-SRU”相匹配的价格&库存,您可以联系我们找货
免费人工找货