Current Transducer HXS 20-NP/SP2
IPN = 5 - 10 - 20 A
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
All Data are given with a R L = 10 kΩ
Features
Electrical data
IPN
IPM
VOUT
VREF
RL
ROUT
CL
VC
IC
Primary nominal current rms
Primary current, measuring range
Output voltage (Analog) @ IP
IP = 0
Reference voltage 1) - Output voltage
VREF Output impedance
VREF Load impedance
Load resistance
Output internal resistance
Capacitive loading
Supply voltage (± 5 %)
Current consumption @ VC = 5 V
± 20
A
± 60
A
VREF ± (0.625·IP/IPN) V
VREF ± 0.0125
V
2.5 ± 0.025
V
typ. 200
Ω
≥ 200
kΩ
≥2
kΩ
< 10
Ω
5.5
> 600
kV
mm
mm
Page 2/3
061018/11
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HXS 20-NP/SP2 (in mm. 1 mm = 0.0394 inch)
18.7
3.5
3.5
1
10.7
16.7
12
0.6
14
6.1
Required
connection
circuitcircuit
Recommended
connection
5V
8 7
HXS 20-NP
/SP2
P=2.54
P=2.54
Ref
Out
GND
Vc
47nF
0V
4.7nF
2 1
Output
47nF
8-1.3d
V Ref.
IN/OUT
4-0.5*0.25
7.7
Operation Principle
Number of
primary turns
Primary current
Primary
nominal maximum
I PN [A]
IP
[A]
resistance
R P [m ohm]
Primary insertion
inductance
[uF]
[µH]
LP
Recommended
PCB connections
IN
1
20
60
0.05
IN
2
10
30
0.2
5
15
1
3 5
7
2
4
6
8
1
3 5
7
2
4
6
8
1
3 5
7
2
4
8
OUT
OUT
Vout
Vref.(IN/OUT)
0V
0.4
6
OUT
Safety
Mechanical characteristics
• General tolerance
• Fastening & connection of primary jumper
Recommended PCB hole
• Fastening & connection of secondary
Recommended PCB hole
+Vc
0.1
IN
4
1
0.025
± 0.2 mm
8 pins Ø 1.3 mm
Ø 1.5 mm
4 pins 0.5 x 0.25
Ø 0.7 mm
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Remarks
• VOUT is positive when IP flows from terminals 1, 3, 5, 7 (IN) to
terminals 2, 4, 6, 8 (OUT).
• Temperature of the primary conductors should not exceed
120°C.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 3/3
061018/11
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
很抱歉,暂时无法提供与“HXS20-NP/SP2”相匹配的价格&库存,您可以联系我们找货