Current Transducer LA 100-P
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
100 A
16019
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance @ with ± 12 V with ± 15 V ISN KN VC IC Vd @ ± 100 A max @ ± 120 A max @ ± 100 A max @ ± 150 A max 100 0 .. ± 150 TA = 70°C TA = 85°C RM min RM max RM min RM max 0 0 0 0 50 22 110 33 0 0 20 20 42 14 102 25 A A
Features
• Closed loop (compensated) current
transducer using the Hall effect
Ω Ω Ω Ω
• Printed circuit board mounting • Insulated plastic case recognized
according to UL 94-V0.
Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
50 mA 1 : 2000 ± 12 .. 15 V 10 (@ ± 15 V) + IS mA 2.5 kV
Advantages
• • • • • • •
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability.
Accuracy - Dynamic performance data
X Accuracy @ IPN , TA = 25°C
L
ε
@ ± 15 V (± 5 %) @ ± 12 .. 15 V (± 5 %)
Linearity
± 0.45 ± 0.70 < 0.15 Max ± 0.10 ± 0.15 ± 0.25 ± 0.50
% % % mA mA mA mA ns µs A/µs kHz
IO I OM IOT tra tr di/dt f
Typ Offset current @ IP = 0, TA = 25°C Residual current 1) @ IP = 0, after an overload of 3 x IPN Thermal drift of IO - 25°C .. + 85°C ± 0.05 - 40°C .. - 25°C ± 0.10 Reaction time @ 10 % of IPN Response time 2) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB)
Applications
• AC variable speed drives and servo
motor drives
< 500 200 DC .. 200
• Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ Mass Standards - 40 .. + 85 - 50 .. + 95 120 128 18 EN 50178 : 1997 °C °C Ω Ω g
• Power supplies for welding
applications.
TA = 70°C TA = 85°C
3)
Notes :
1) 2) 3)
The result of the coercive field of the magnetic circuit With a di/dt of 100 A/µs A list of corresponding tests is available.
060201/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. page 1/2
LEM
w w w .lem.com
Dimensions LA 100-P
Bottom view
(in mm. 1 mm = 0.0394 inch)
Left view
Secondary terminals swiss made
Terminal + : supply voltage + 12 .. 15 V Terminal - : supply voltage - 12 .. 15 V Terminal M : measure
Connection
Standard 00 or N ° S P ..
Year
Week
Front view Mechanical characteristics
• General tolerance • Primary through-hole • Fastening & connection of secondary
Recommended PCB hole ± 0.2 mm 12.7 x 7 mm 3 pins 0.63 x 0.56 mm 0.9 mm
Remarks
• IS is positive when IP flows in the direction of the arrow. • Temperature of the primary conductor should not exceed
100°C.
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
• In order to achieve the best magnetic coupling, the primary
windings have to be wound over the top edge of the device.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...), please contact us.
060201/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. page 2/2
LEM
w w w .lem.com