Current Transducer LA 100-S/SP1
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
100 A
0629
Electrical data
I PN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with ± 15 V ISN KN VC IC Vd @ ± 100 A max @ ± 200 A max 100 0 .. ± 200 RM min RM max 0 0 50 1 : 2000 ± 15 22 + IS 3 180 50 A A Ω Ω mA V mA kV
Features
• Closed loop (compensated) current • Insulated plastic case recognized
according to UL 94-V0. transducer using the Hall effect
Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 min
Special features
• I P = 0 .. ± 200 A • K N = 1 : 2000
Accuracy - Dynamic performance data
XG
Advantages
± 0.5 < 0.1 Typ Max ± 0.1 ± 0.4 % % mA mA µs A/µs kHz
ε
L
Overall accuracy @ IPN, T A = 25°C Linearity error Offset current @ IP = 0, T A = 25°C Thermal drift of IO - 10 °C .. + 70°C Response time 1) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB)
IO IOT tr di/dt f
± 0.2
50 DC .. 150
• • • • • • •
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability.
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ T A = 70°C Mass Standards 2) - 10 .. + 70 - 25 .. + 85 85 65 EN 50178 °C °C Ω g
Applications
• AC variable speed drives and servo • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies • Switched Mode Power Supplies • Power supplies for welding
applications. (SMPS) (UPS) motor drives
Notes :
1) 2)
With a di/dt of 50 A/µs A list of corresponding tests is available.
0 60901/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. page 1/2
LEM
www.lem.com
Dimensions LA 100-S/SP1
Front view
(in mm. 1 mm = 0.0394 inch)
Left view
Secondary terminals
Terminal Terminal Terminal Terminal + M 0 : : : : supply voltage + 15 V supply voltage - 15 V measure NC
Connection
Top view Mechanical characteristics
• • • •
General tolerance Fastening Primary through-hole Connection of secondary ± 0.3 mm 2 holes ∅ 3.2 mm 16 x 10 mm Molex 5045-04/AG
Remarks
• IS is positive when IP flows in the direction of the arrow. • Temperature of the primary conductor should not exceed • Dynamic performances (di/dt and response time) are best • In order to achieve the best magnetic coupling, the primary • To measure nominal currents of less than 100 A, the optimum accuracy is obtained by having several primary turns (nominal current x number of turns < 100 At). windings have to be wound over the top edge of the device. with a single bar completely filling the primary hole. 100°C.
060901/6
L EM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 2/2
LEM
www.lem.com