LA150-TP

LA150-TP

  • 厂商:

    LEM(莱姆)

  • 封装:

    -

  • 描述:

    SENSORCURRENTHALL150AAC/DC

  • 数据手册
  • 价格&库存
LA150-TP 数据手册
Current Transducer LA 150-TP For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. Features Electrical data IPN Primary nominal current rms IPM Primary current, measuring range RM Measuring resistance @ 85°C with ± 12 V @ ± 150 A max @ ± 212 A max with ± 15 V @ ± 150 A max @ ± 212 A max ISN Secondary nominal current rms K N Conversion ratio VC Supply voltage (± 5 %) IC Current consumption 150 A 0 .. ± 212 A RM min RM max 0 40 Ω 0 3 Ω 0 78 Ω 0 30 Ω 75 mA 1 : 2000 ± 12 .. 15 V 10 (@ ± 15 V) + Is mA Accuracy - Dynamic performance data X ε L IOE IOM IOT tra tr di/dt BW Accuracy @ IPN, TA = 25°C < 0.5 % Linearity error < 0.1 % Typ Max Electrical offset current @ IP = 0, TA = 25°C ± 0.10 mA Magnetic offset current @ IP = 0 and specified RM, after an overload of 3 x IPN ± 0.25 mA Temperature variation of IO - 40°C .. + 85°C ± 0.15 ± 0.30 mA Reaction time to 10 % of IPN step < 300 ns Response time 1) to 90 % of IPN step < 500 ns di/dt accurately followed > 100 A/µs Frequency bandwidth (- 1 dB) DC .. 150 kHz General data TA TS RS m IPN = 150 A Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 25°C Mass Standard - 40 .. + 85 °C - 40 .. + 90 °C 64 ± 2 Ω < 35 g EN 50178: 1997 ●● Closed loop (compensated) current transducer using the Hall effect ●● Isolated plastic case recognized according to UL 94-V0. Advantages ●● ●● ●● ●● ●● ●● ●● Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference ●● Current overload capability. Applications ●● AC variable speed drives and servo motor drives ●● Static converters for DC motor drives ●● Battery supplied applications ●● Uninterruptible Power Supplies (UPS) ●● Switched Mode Power Supplies (SMPS) ●● Power supplies for welding applications. Application domain ●● Industrial. Note: 1) With a di/dt of 100 A/µs. Page 1/3 14December2012/version 3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com Current Transducer LA 150-TP Isolation characteristics Vd Vw Ve dCp dCI CTI Rms voltage for AC insulation test, 50 Hz, 1 min Impulse withstand voltage 1.2/50 µs Partial discharge extinction voltage rms @ 10 pC Creepage distance Clearance Comparative Tracking Index (group I) 4.3 8 1.3 Min 8 8 600 kV kV kV mm mm Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ●● Over voltage category OV 3 ●● Pollution degree PD2 ●● Non-uniform field EN 50178 IEC 61010-1 Rated insulation voltage Nominal voltage Basic insulation 1000 V 1000 V Reinforced insulation 600 V 400 V dCp, dCI, Vw Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 14December2012/version 3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com Dimensions LA 150-TP (in mm) Connection Mechanical characteristics ●● General tolerance ●● Fastening & connection of primary Recommended PCB hole ●● Fastening & connection of secondary Recommended PCB hole Remarks ± 0.5 mm 2 pins 3×1.6 mm Ø 3.6 mm 3 pins 0.6×0.6 mm Ø 1.1 mm ●● IS is positive when IP flows in the direction of the arrow. ●● Temperature of the primary conductor should not exceed 100°C. ●● Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole. ●● This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 14December2012/version 3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
LA150-TP 价格&库存

很抱歉,暂时无法提供与“LA150-TP”相匹配的价格&库存,您可以联系我们找货

免费人工找货