Current Transducer LA 150-TP
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit and the secondary
circuit.
Features
Electrical data
IPN
Primary nominal current rms
IPM
Primary current, measuring range
RM
Measuring resistance @ 85°C
with ± 12 V
@ ± 150 A max
@ ± 212 A max
with ± 15 V
@ ± 150 A max
@ ± 212 A max
ISN
Secondary nominal current rms
K N
Conversion ratio
VC
Supply voltage (± 5 %)
IC
Current consumption
150
A
0 .. ± 212
A
RM min RM max
0 40
Ω
0 3
Ω
0 78
Ω
0 30
Ω
75
mA
1 : 2000
± 12 .. 15
V
10 (@ ± 15 V) + Is mA
Accuracy - Dynamic performance data
X
ε
L
IOE
IOM
IOT
tra
tr
di/dt
BW
Accuracy @ IPN, TA = 25°C
< 0.5
%
Linearity error
< 0.1
%
Typ Max
Electrical offset current @ IP = 0, TA = 25°C
± 0.10 mA
Magnetic offset current @ IP = 0 and specified RM,
after an overload of 3 x IPN
± 0.25 mA
Temperature variation of IO
- 40°C .. + 85°C ± 0.15 ± 0.30 mA
Reaction time to 10 % of IPN step
< 300
ns
Response time 1) to 90 % of IPN step
< 500
ns
di/dt accurately followed
> 100
A/µs
Frequency bandwidth (- 1 dB)
DC .. 150
kHz
General data
TA
TS
RS
m
IPN = 150 A
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ TA = 25°C
Mass
Standard
- 40 .. + 85
°C
- 40 .. + 90
°C
64 ± 2
Ω
< 35
g
EN 50178: 1997
●● Closed loop (compensated)
current transducer using the Hall
effect
●● Isolated plastic case recognized
according to UL 94-V0.
Advantages
●●
●●
●●
●●
●●
●●
●●
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
●● Current overload capability.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Industrial.
Note: 1) With a di/dt of 100 A/µs.
Page 1/3
14December2012/version 3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Current Transducer LA 150-TP
Isolation characteristics
Vd
Vw
Ve
dCp
dCI
CTI
Rms voltage for AC insulation test, 50 Hz, 1 min
Impulse withstand voltage 1.2/50 µs
Partial discharge extinction voltage rms @ 10 pC
Creepage distance
Clearance
Comparative Tracking Index (group I)
4.3
8
1.3
Min
8
8
600
kV
kV
kV
mm
mm
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
●● Over voltage category OV 3
●● Pollution degree PD2
●● Non-uniform field
EN 50178
IEC 61010-1
Rated insulation voltage
Nominal voltage
Basic insulation
1000 V
1000 V
Reinforced insulation
600 V
400 V
dCp, dCI, Vw
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
14December2012/version 3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Dimensions LA 150-TP (in mm)
Connection
Mechanical characteristics
●● General tolerance
●● Fastening & connection of primary
Recommended PCB hole
●● Fastening & connection of secondary
Recommended PCB hole
Remarks
± 0.5 mm
2 pins 3×1.6 mm
Ø 3.6 mm
3 pins 0.6×0.6 mm
Ø 1.1 mm
●● IS is positive when IP flows in the direction of the arrow.
●● Temperature of the primary conductor should not exceed
100°C.
●● Dynamic performances (di/dt and response time) are
best with a single bar completely filling the primary hole.
●● This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
Page 3/3
14December2012/version 3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
很抱歉,暂时无法提供与“LA150-TP”相匹配的价格&库存,您可以联系我们找货
免费人工找货