Current Transducer LA 25-P
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic separation between the primary circuit and the secondary
circuit.
IPN = 25 A
Electrical data
IPN
Primary nominal rms current
25
A
IPM
Primary current, measuring range
0 .. ± 55
A
R M
Measuring resistance
TA = 70 °C TA = 85 °C
RM min RM max RM min RM max
with ± 12 V
@ ± 25 A max
10 280 60 275
Ω
@ ± 55 A max
10 80 60 75
Ω
with ± 15 V
@ ± 25 A max
50 400 135 395
Ω
@ ± 55 A max
50 140 135 135
Ω
ISN
Secondary nominal rms current
25
mA
K N
Conversion ratio
1 : 1000
U C
Supply voltage (± 5 %)
± 12 .. 15
V
IC
Current consumption
10 (@ ± 15 V) + IS mA
Accuracy - Dynamic performance data
X
Accuracy @ IPN, TA = 25 °C
@ ± 15 V (± 5 %)
± 0.95
@ ± 12 .. 15 V (± 5 %)
± 1.25
εL
Linearity error
< 0.15
Typ Max
IO
Offset current @ IP = 0, TA = 25 °C
± 0.2
IOM
Magnetic offset current 1) @ IP = 0 and specified RM,
after an overload of 3 × IPN
± 0.3
IOT
Temperature variation of IO
0 °C .. + 70 °C
± 0.1 ± 0.5
- 25 °C .. + 85 °C
± 0.1 ± 0.6
tra
Reaction time
< 500
tr
Step response time to 90 % of IPN
< 1
di/dt di/dt accurately followed
> 200
BW
Frequency bandwidth (- 1 dB)
DC .. 200
%
%
%
mA
mA
mA
mA
ns
µs
A/µs
kHz
General data
TA
TS
RS
m
Ambient operating temperature
Ambient storage temperature
Resistance of secondary winding @ TA = 70 °C
@ TA = 85 °C
Mass
Standard
- 25 .. + 85
°C
- 40 .. + 90
°C
80
Ω
85
Ω
24
g
EN 50178: 1997
Features
●● Closed loop (compensated)
current transducer using the Hall
effect
●● Insulating plastic case recognized
according to UL 94-V0.
Advantages
●●
●●
●●
●●
●●
●●
●●
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
●● Current overload capability.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Industrial.
Note: 1) Result of the coercive field of the magnetic circuit.
N° 97.13.19.000.0
13November2014/version 3
Page 1/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Current Transducer LA 25-P
Insulation coordination
U d
ÛW
dCp
dCI
CTI
Rms voltage for AC insulation test, 50 Hz, 1 min
3
Impulse withstand voltage 1.2/50 µs
5.7
Min
Creepage distance
5
Clearance
5
Comparative tracking index (group I)
600
kV
kV
mm
mm
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
●● Over voltage category OV 3
●● Pollution degree PD2
●● Non-uniform field
dCp, dCI, ÛW
EN 50178
IEC 61010-1
Rated insulation voltage
Nominal voltage
Basic insulation
500 V
500 V
Reinforced insulation
250 V
250 V
Safety
This transducer must be used in limited-energy secondary circuits according to
IEC 61010-1.
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer’s
operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
13November2014/version 3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Dimensions LA 25-P (in mm)
dCl
dCp
Connection
IP
IS
RM
UC
UC
dCl
IP
dCl
Mechanical characteristics
●● General tolerance
●● Primary through-hole
●● Fastening & connection of secondary
●● Recommended PCB hole
Remarks
± 0.2 mm
12.7 × 7 mm
3 pins
0.6 × 0.7 mm
⌀ 1.2 mm
dCp
IP
IS
RM
●● IS is positive when IP flows in the direction of the arrow.
UC
●● Temperature of the primary conductor should not exceed
90 °C.
U
C
●● Installation of the transducer must be done unless
otherwise specified on the datasheet, according to LEM
Transducer Generic Mounting Rules. Please refer to
LEM document N°ANE120504 available on our Web site:
Products/Product Documentation.
●● Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
●● In order to achieve the best magnetic coupling, the
primary windings have to be wound over the top edge of
the device.
●● This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
Page 3/3
13November2014/version 3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com