Current Transducer LA 25-NP/SP14
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
0.25 A
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with ± 15 V ISN KN VC IC Vd Vb @ ± 0.25 A max @ ± 0.36 A max 0.25 0 .. ± 0.36 R M min R M max 100 100 320 190 A A Ω Ω mA V mA kV V V
Features
•Closed loop (compensated) multiturns current transducer using the Hall effect •Insulated plastic case recognized according to UL 94-V0.
Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn R.m.s. rated voltage 1), safe separation basic isolation
25 100 : 1000 ± 15 10 + IS 2.5 600 1700
Special features
•IPN •IP •K N •TA
= = = = 0.25 A 0 .. ± 0.36 A 100 : 1000 - 10°C .. + 70°C.
Accuracy - Dynamic performance data
X
Advantages
± 0.5 < 0.2 % % mA mA mA µs kHz
ε
L
Typical accuracy @ IPN , TA = 25°C Linearity
IO IOM IOT tr f
Typ Max Offset current 2) @ IP = 0, TA = 25°C ± 0.05 ± 0.15 Residual current 3) @ IP = 0, after an overload of 3 x IPN ± 0.05 ± 0.15 Thermal drift of IO - 10°C .. + 70°C ± 0.10 ± 0.35 Response time 4) @ 90 % of IP max Frequency bandwidth (- 1 dB) 1500 22 EN 50178 °C °C mΩ Ω µH MΩ g
Applications
•AC variable speed drives and servo
motor drives
•Static converters for DC motor drives •Battery supplied applications •Uninterruptible Power Supplies
(UPS)
•Switched Mode Power Supplies
(SMPS)
•Power supplies for welding
Notes :
1) 2) 3) 4) 5)
Pollution class 2 Measurement carried out after 15 mn functionning The result of the coercive field of the magnetic circuit With a di/dt of 100 A/µs A list of corresponding tests is available
applications.
990126/2
LEM Components
w w w .lem.com
Dimensions LA 25-NP/SP14
Bottom view
(in mm. 1 mm = 0.0394 inch)
Right view
Top view
swiss made
Standard 00 or N° SP..
Year
Week
Secondary terminals
Terminal + : supply voltage + 15 V Terminal M : measure Terminal - : supply voltage - 15 V
Connection
in out
Back view Mechanical characteristics
•General tolerance •Fastening & connection of primary
± 0.2 mm 2 pins 0.635 x 0.635 mm •Fastening & connection of secondary 3 pins ∅ 1 mm •Recommended PCB hole 1.2 mm
Remark
•IS is positive when IP flows from terminal + to terminal -.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.