Current Transducer LAH 100-P
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic separation between the primary circuit and the secondary
circuit.
Electrical data
IP N =
100 A
Features
IP N Primary nominal RMS current
100
A
IP M Primary current, measuring range 1)
0 ... ±160
A
RM Measuring resistance @
TA = 70 °C TA = 85 °C
RM minRM max RM minRM max
with ±12 V
@ IP N [±A DC]
0 63
0 57 Ω
@ IP N [A RMS] 2)
0 11
0 5
Ω
with ±15 V
@ IP N [±A DC]
20 120
45 114 Ω
@ IP N [A RMS] 2)
20 51
45 45 Ω
@ IP < IP N 3)
IS N Secondary nominal RMS current
50
mA
NP/NS Turns ratio
1 : 2000
UC Supply voltage (±5 %)
±12 ... 15
V
IC
Current consumption
10 (@ ± 15 V) + IS mA
Accuracy - Dynamic performance data
εtot Total error 4) @ IP N, TA = 25 °C
±0.25
%
εL
Linearity error
< 0.15
%
Typ
Max
IO Offset current referred to primary @ TA = 25 °C
±300
mA
IO Offset current referred to secondary @ TA = 25 °C ±0.15 mA
IO M Magnetic offset current @ IP = 0, referred to secondary
and specified RM, after an overload of 5 × IP N ±0.10 ±0.15 mA
IO T Temperature variation of IO, referred to secondary
0 °C ... +70 °C ±0.10 ±0.40
mA
‒25 °C ... +85 °C ±0.10 ±0.50
mA
tD 10 Delay time to 10 % of the final output value for IP N step 5) < 200
ns
tD 90 Delay time to 90 % of the final output value for IP N step 5) < 500
ns
BW Frequency bandwidth (‒1 dB)
DC ... 200
kHz
General data
TA Ambient operating temperature
TA st Ambient storage temperature
RS Resistance of secondary winding @ TA = 70 °C
@ TA = 85 °C
m
Mass
Standards
Notes: 1) For 10 s, with RM ≤ 25 Ω (UC = ±15 V)
2)
50 Hz Sinusoidal
3)
The measuring resistance RM min may be lower
(see “LAH Technical Information” leaflet)
4)
Without IO & IO M
5)
For a di/dt = 200 A/µs.
‒25 ... +85
°C
‒40 ... +90
°C
115
Ω
121
Ω
24
g
EN 50178: 1997
● Closed loop (compensated)
current transducer using the Hall
effect
● Printed circuit board mounting
● Insulating plastic case recognized
according to UL 94-V0.
Advantages
●
●
●
●
●
●
●
Excellent accuracy
Very good linearity
Low temperature drift
Optimized delay time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
● Current overload capability.
Applications
● AC variable speed drives and
servo motor drives
● Static converters for DC motor
drives
● Battery supplied applications
● Uninterruptible Power Supplies
(UPS)
● Switched Mode Power Supplies
(SMPS)
● Power supplies for welding
applications.
Application domain
● Industrial.
N° 97.34.34.000.0
7June2021/version 14
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
Current Transducer LAH 100-P
Isolation characteristics
Ud RMS voltage for AC insulation test, 50/60 Hz, 1 min
UNi Impulse withstand voltage 1.2/50 µs
Ue Partial discharge extinction RMS voltage @ 10 pC
dCp Creepage distance 1)
dCI Clearance 1)
CTI Comparative tracking index (group IIIa)
5
12
> 2
Min
11.75
11.75
175
kV
kV
kV
mm
mm
Note: 1) On PCB with soldering pattern UTEC93-703.
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
● Over voltage category OV 3
● Pollution degree PD2
● Non-uniform field
EN 50178
IEC 61010-1
Rated insulation voltage
Nominal voltage
Basic insulation
1000 V
1000 V
Reinforced insulation
500 V
500 V
dCp, dCI, UNi
Safety
This transducer must be used in limited-energy secondary circuits according to
IEC 61010-1.
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer’s
operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury
and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation. A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
7June2021/version 14
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
Dimensions LAH 100-P (in mm)
Connection
IP
IS
RM
0V
+UC
-UC
dCI
11.75
Number
of primary
turns
1
Primary current
IP N [ A ]
nominal
maximum
IP [ A ]
100
160
7June2021/version 14
11.75
Nominal
output currrent
Turns
ratio
Primary
resistance
Primary insertion
inductance
IS N [ mA ]
NP/NS
RP [ mΩ ]
LP [ µH ]
50
1 : 2000
0.08
0.007
Mechanical characteristics
● General tolerance
● Fastening & connection of primary
Recommended PCB hole
● Fastening & connection of secondary
Recommended PCB hole
dCp
Remarks
±0.2 mm
6 pins 1.4 x 1 mm
2 mm
3 pins 0.7 x 0.6 mm
1.2 mm
● IS is positive when IP flows from terminals “IN” to
terminals “OUT”.
● The jumper temperature and PCB should not exceed
100°C.
● This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers,
in order to improve them, without prior notice
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com