0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LAH100-P

LAH100-P

  • 厂商:

    LEM(莱姆)

  • 封装:

    插件

  • 描述:

    霍尔电流传感器 -12V~15V 100A 插件

  • 数据手册
  • 价格&库存
LAH100-P 数据手册
Current Transducer LAH 100-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Electrical data IP N = 100 A Features IP N Primary nominal RMS current 100 A IP M Primary current, measuring range 1) 0 ... ±160 A RM Measuring resistance @ TA = 70 °C TA = 85 °C RM minRM max RM minRM max with ±12 V @ IP N [±A DC] 0 63 0 57 Ω @ IP N [A RMS] 2) 0 11 0 5 Ω with ±15 V @ IP N [±A DC] 20 120 45 114 Ω @ IP N [A RMS] 2) 20 51 45 45 Ω @ IP < IP N 3) IS N Secondary nominal RMS current 50 mA NP/NS Turns ratio 1 : 2000 UC Supply voltage (±5 %) ±12 ... 15 V IC Current consumption 10 (@ ± 15 V) + IS mA Accuracy - Dynamic performance data εtot Total error 4) @ IP N, TA = 25 °C ±0.25 % εL Linearity error < 0.15 % Typ Max IO Offset current referred to primary @ TA = 25 °C ±300 mA IO Offset current referred to secondary @ TA = 25 °C ±0.15 mA IO M Magnetic offset current @ IP = 0, referred to secondary and specified RM, after an overload of 5 × IP N ±0.10 ±0.15 mA IO T Temperature variation of IO, referred to secondary 0 °C ... +70 °C ±0.10 ±0.40 mA ‒25 °C ... +85 °C ±0.10 ±0.50 mA tD 10 Delay time to 10 % of the final output value for IP N step 5) < 200 ns tD 90 Delay time to 90 % of the final output value for IP N step 5) < 500 ns BW Frequency bandwidth (‒1 dB) DC ... 200 kHz General data TA Ambient operating temperature TA st Ambient storage temperature RS Resistance of secondary winding @ TA = 70 °C @ TA = 85 °C m Mass Standards Notes: 1) For 10 s, with RM ≤ 25 Ω (UC = ±15 V) 2) 50 Hz Sinusoidal 3) The measuring resistance RM min may be lower (see “LAH Technical Information” leaflet) 4) Without IO & IO M 5) For a di/dt = 200 A/µs. ‒25 ... +85 °C ‒40 ... +90 °C 115 Ω 121 Ω 24 g EN 50178: 1997 ● Closed loop (compensated) current transducer using the Hall effect ● Printed circuit board mounting ● Insulating plastic case recognized according to UL 94-V0. Advantages ● ● ● ● ● ● ● Excellent accuracy Very good linearity Low temperature drift Optimized delay time Wide frequency bandwidth No insertion losses High immunity to external interference ● Current overload capability. Applications ● AC variable speed drives and servo motor drives ● Static converters for DC motor drives ● Battery supplied applications ● Uninterruptible Power Supplies (UPS) ● Switched Mode Power Supplies (SMPS) ● Power supplies for welding applications. Application domain ● Industrial. N° 97.34.34.000.0 7June2021/version 14 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com Current Transducer LAH 100-P Isolation characteristics Ud RMS voltage for AC insulation test, 50/60 Hz, 1 min UNi Impulse withstand voltage 1.2/50 µs Ue Partial discharge extinction RMS voltage @ 10 pC dCp Creepage distance 1) dCI Clearance 1) CTI Comparative tracking index (group IIIa) 5 12 > 2 Min 11.75 11.75 175 kV kV kV mm mm Note: 1) On PCB with soldering pattern UTEC93-703. Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ● Over voltage category OV 3 ● Pollution degree PD2 ● Non-uniform field EN 50178 IEC 61010-1 Rated insulation voltage Nominal voltage Basic insulation 1000 V 1000 V Reinforced insulation 500 V 500 V dCp, dCI, UNi Safety This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. 7June2021/version 14 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com Dimensions LAH 100-P (in mm) Connection IP IS RM 0V +UC -UC dCI 11.75 Number of primary turns 1 Primary current IP N [ A ] nominal maximum IP [ A ] 100 160 7June2021/version 14 11.75 Nominal output currrent Turns ratio Primary resistance Primary insertion inductance IS N [ mA ] NP/NS RP [ mΩ ] LP [ µH ] 50 1 : 2000 0.08 0.007 Mechanical characteristics ● General tolerance ● Fastening & connection of primary Recommended PCB hole ● Fastening & connection of secondary Recommended PCB hole dCp Remarks ±0.2 mm 6 pins 1.4 x 1 mm 2 mm 3 pins 0.7 x 0.6 mm 1.2 mm ● IS is positive when IP flows from terminals “IN” to terminals “OUT”. ● The jumper temperature and PCB should not exceed 100°C. ● This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice LEM International SA Chemin des Aulx 8 1228 PLAN-LES-OUATES Switzerland www.lem.com
LAH100-P 价格&库存

很抱歉,暂时无法提供与“LAH100-P”相匹配的价格&库存,您可以联系我们找货

免费人工找货
LAH100-P
    •  国内价格
    • 1+87.83640
    • 10+84.16440
    • 30+77.80320

    库存:6